Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

ECO1

ECO5

ECO2

ECO3EXPERT
WWW.CHISON.COM
ECO6
More More More
Capability Performance Application
Outlook

• 12 inch LED
Rotatable • Dedicated trolley
• All in one

2 probe ports
• Various Outputs
 CW,TDI
 2D Steer
 Trapezoid imaging
 CPA, DPD
 Super needle
 B/BC
 Auto IMT
More  Triplex
Capability  Auto trace in PW
 Full screen
CW
• Required for cardiac exam to detect the high velocity
• Regurgitation(mitral valve , aorta valve)
• Available for phased array probe , micro convex probe
TDI(tissue doppler imaging)
• Evaluate myocardium motion accurately
• Doppler imaging quantifies low-velocity myocardium
motion
2D Steer
•Steer the Scan line of B mode
-Receive more reflected echo
-More accurate Needle surface and
tiny tissue
-two kinds of linear probe

L7M-A 40mm L7S-A 30mm


CPA , DPD
• High sensitivity
• Better for tiny vessel
Super needle
• Enhance the needle displaying in image ,
without distortion of the needle, increase
successful rate

Without With
B/BC Mode
• Both B and color mode in real time
• Provide the vessel flow, show the details inside of the
vessel at the same time
Auto IMT
• Trace intima automatically
• Provide three results at the same time
• Greatly simplify the work flow and improve efficiency
• Early detection of atherosclerosis
Triplex Mode
•B,C, D are all in real time
•Easy to get the spectrum ,
•Save time, make the diagnose efficiently
Auto Trace in PW mode
•One key to trace the spectrum automatically;
•Obtain the measurement automatically;
Full Screen Display
• One key to enlarge the image to full screen
• Easy to view from distance
• Compound imaging
• SRA(Speckle Reduction )
• AIO(automatic image optimization)
• THI
• Latest image optimization Algorithm
More
Performance
Compounding Imaging
• Multiple scan-angles to form a single image
• Enhance contrast resolution
• Reduce shadow, less angle dependence
SRA(Speckle Reduction )
• The technique to reduce the noise
• Suppress speckle
• Smooth the tissue images
• Make the faint edge more appearing
• Versatile probes
• Rich applications
More
Application
Abdomen, pediatric-
Small parts, vascular , MSK-

Transducers OB/GYN, urology -


Cardiac , emergency -
…….-
Efficient
Workflow
 Complete DICOM function
 Hot key for quick reaction
 User define function
 Multiple languages
Accessories
Anti-water keyboard
cover

Battery :BT-2500

Carrying case: BG-100


Trolley : TR 9000 Vehicle Power Charger
Thank you!

We reserve the rights to make changes


to this presentation without prior notice.

You might also like