Sive Sive Mas Pevecent ∑retaind% passing%
no size retaind of mass
retaind
4 4.75 20.7 20.7 5.17 94.83
10 2.000 41.8 62.5 15.62 84.38
20 0.850 75.2 137.7 34.42 65.58
40 0.425 129.5 267.2 66.8 33.2
60 0.250 100.3 367.5 91.87 8.13
100 0.15 20.5 388 97 3
200 0.075 8.4 396.4 99.1 0.9
pan 3.6 400 100 0
∑400

Because we look at the sieve 200 and the amount of pass and
the amount of the remaining if the amount of pass is greater
than 50% then the soil is soft and if it is less than 50% then the
soil is coarse
In this test, the amount of turbo passing through a sieve of 200
hues (0.9) is less than 50% if the soil is coarse.

Liquid Limit and Plastic Limit


P.L=25.47%
L.L=39.5%
Find the Plastic Index
P.I=L.L-P.L
P.I=14.03%
( )