2 Legal notice
The copyright of this document is owned by Raisecom. No part of this publication
may be excerpted, reproduced, translated or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without written
consent from Raisecom Technology Co., Ltd.
When a user finishes installing the device and starts using it, it implies that
the user has completely understood safety statements of this device. The
user is liable for any losses or damage caused by violation of safety
statements.
The information in this document is subject to change without notice. Every
effort has been made in the preparation of this document to ensure accuracy
of the contents, but all statements, information, and recommendations in this
document do not constitute the warranty of any kind, express or implied.
Raisecom is not liable for any losses or damage caused by natural disasters
beyond Raisecom's responsibilities, such as earthquake and flood.
3 Device specifications
3.1 Technical specifications
Table 3-1 lists technical specifications of the ISCOM HT803G-1GE.
4
Table 3-2 lists technical specifications of the PON interface on the ISCOM
HT803G-1GE.
5
4 LEDs
6
5 Connection and usage
5.1 Interfaces and buttons
7
-
----------------------------------------------------------
Warranty Record
Address: East-11, Raisecom Building, 10 Xi Bei Wang East Road, Haidian District, Beijing, China
Post Code: 10085
Tel: +86-10-82883305
www.raisecom.com
8
-------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------------------------------------------------
-------- ---------------------------------------------------
Product Warranty Sheet
Customer Name:_ _ _ _ _ _ _ _ _ _ _ Phone Number:_ _ _ _ _ _ _ _ _ _ _ _ _ _
Address:_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Thank you very much for purchasing Raisecom products. For the sake of being
responsible for you, and guaranteeing premium after-sale service, please carefully
read and fill up this sheet.
Warranty Policy:
1. Our products carry a type warranty period of 1 year after warranty sheet has
been provided to you. In this period, any problem that caused by the product
itself and confirmed by our technical engineers will be fixed free of charge.
2. Please present the warranty sheet and the receipt when requesting services.
9
5.2 Installation modes
The ISCOM HT803G-1GE can be installed on a stable workbench or a wall.
Step 1 Choose a proper height of installation position so that you can easily
observe LEDs and connect the power supply.
Step 2 Knock two cement nails, with spacing of 63 mm (distance between two
wall-mount holes), into the wall. The diameter of a cement nail should
be smaller than that of the wall-mount hole (5 mm).
Step 3 Align wall-mount holes with knocked cement nails, and hang the device
on nails. The device is hung by the nails on the wall.
Step 4 Check by slightly shaking the device whether it is firmly installed on the
wall.
10
5.3 Connecting power supply
The ISCOM HT803G-1GE adopts an external power adapter to supply power:
Input of the power adapter: 100–240 VAC (50/60 Hz)
Output of the power adapter: 12 VDC and 0.5 A
Step 1 Insert the 12 VDC power adapter plug into the power interface on the
ISCOM HT803G-1GE.
Step 2 Insert the 100–240 VAC power adapter plug into the AC power socket.
Step 2 Press the power button. If the Power LED is green, it indicates that the
ISCOM HT803G-1GE is powered on properly.
Step 2 Press the POWER button. If the Power LED is green, it indicates that
the ISCOM HT803G-1GE is powered on properly.
11
Step 3 Configure the IP address of the PC. For example, configure the IP
address to 192.168.1.X (X is any number between 2 and 254), subnet
mask to 255.255.255.0.
Step 4 Open a browser. Type "http://192.168.1.1", and press Enter. The Web
login interface appears.
Step 5 Enter the correct user name (telecomadmin) and password (q!w@e#) to
access the ISCOM HT803G-1GE.
12
6 FAQ
Why is Power LED off?
Please check whether the POWER button is pressed.
Please check whether the power adapter is the standard one equipped for the
ISCOM HT803G-1GE.
Please ensure that the power adapter and the power interface/power outlet
are connected firmly. Alternatively, try to remove the power adapter plug,
and then re-insert it. If necessary, please use the voltmeter to check whether
the output voltage of the power adapter is 12 V.
13
Please check whether the NIC is properly working. In a Windows operating
system (taking Windows XP for example), right-click the My Computer
icon, and then choose Manage. Click Device Manager on the left tree
topology to check whether a device with "?" or "!" symbol is displayed
under the Network adapters option. If yes, uninstall the device driver and re-
install the driver. Or you can insert the NIC into another slot. If the problem
is not solved, replace the NIC.
RoHS specifies maximum levels for cadmium (Cd), mercury (Hg), Hexavalent Chromium
(Cr VI), Polybrominated Biphenyls (PBBs), and Polybrominated Diphenyl Ethers (PBDEs)
on each homogeneous material in the product.
15
Raisecom Technology Co., Ltd. provides customers with comprehensive technical
support and services. For any assistance, please contact our local office or
company headquarters.
Website: http://www.raisecom.com
Tel: 8610-82883305
Fax: 8610-82883056
Email: export@raisecom.com
Address: Raisecom Building, No. 11, East Area, No. 10 Block, East Xibeiwang
Road, Haidian District, Beijing, P.R.China