S19091-DIB-NASJV-PK1-MOS-IFC-A-AAR-0001-02
LEGEND
REMARKS:
o FGL = 100.000 (FIXED GROUND LEVEL)
ROOFING SYSTEM ROOFING SYSTEM o FFL = FINISHED FLOOR LEVEL
(AS PER APPROVED MATERIAL) (AS PER APPROVED MATERIAL) o TOC = TOP OF CONCRETE
o FPL = FINISHED PAVEMENT LEVEL
11 Feb 2023 o FRL = FINISHED ROAD LEVEL
RC SLAB 220MM THK o FCL = FINISHED CEILING LEVEL ( FROM FFL)
RC SLAB 220MM THK o TOS = TOP OF STEEL
SHUT NAIL CONNECTION WITH o TOPR = TOP OF PARAPET
CONCRETE SLAB SHUT NAIL CONNECTION WITH
CONCRETE SLAB NOTES:
PRECAST WORK
· ALL DIMENSIONS ARE IN MILLIMETERS, ALL DIMENSIONS SHOULD BE VERIFIED
ON SITE AND APPROVED BY THE ENGINEER.
· ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, ROADS,
12 GA MIN. GALVANIZED INFRASTRUCTURE AND SPECIAL SYSTEMS DRAWINGS AND ALL ELECTRICAL
RC BEAM 200X600 MM 12 GA MIN. GALVANIZED 12 GA MIN. GALVANIZED
WIRE HANGER (TYP.) DRAWINGS AND ALL RELEVANT SECTIONS OF THE SPECIFICATIONS.
WIRE HANGER (TYP.) WIRE HANGER (TYP.)
· FOR SYMBOLS AND ABBREVIATIONS REFER TO
ADJUSTABLE SPRING CLIP DRAWING No. S19091-DIB-NASJV-PK1-BLD-SD-A-AAR-00-GL-000001-00
ADJUSTABLE SPRING CLIP
· FOR THE STRUCTURAL ELEMENTS, REFER TO STRUCTURAL DRAWINGS.
· FOR EXTERNAL LEVELS, SLOPES, FINISHES, DIMENSIONS, ETC...., REFER TO
CHANNEL SUPPORT BRACKET
CHANNEL SUPPORT BRACKET LANDSCAPE & ROADS DRAWINGS.
· FOR FIRE RATED WALLS, REFER TO LIFE SAFETY DRAWINGS.
FURRING CHANNEL · FOR INTERNAL FINISHES, REFER TO FINISHING SCHEDULES.
FURRING CHANNEL PREFORMED WIRE CLIP
· FOR DOORS ROUGH OPENING DIMENSIONS, REFER TO DOORS SCHEDULE.
· FOR WINDOW ROUGH OPENINGS REFER TO WINDOW SCHEDULE.
INTERMEDIATE CHANNEL INTERMEDIATE CHANNEL INTERMEDIATE CHANNEL · ALL WALLS AT BACK OF MILLWORKS/VANITIES TO BE SOLID MASONRY
AT TOILET AND KITHCHEN/PANTRIES.
5 S19091-DIB-NASJV-PK1-MOS-DD-M-MHV-02-GF-00-0001-00
SHADOWLINE BEAD
CONCRETE BLOCK WITH CEMENT
6 S19091-DIB-NASJV-PK1-MOS-DD-M-MFF-02-GF-00-0001-00
PLASTER OR CONCRETE COLUMN
CONCRETE BLOCK WITH CEMENT PLASTER OR 7 S19091-DIB-NASJV-PK1-MOS-DD-A-AAR-11-GL-00-0000-02
CONCRETE COLUMN
8 S19091-DIB-NASJV-PK1-MOS-DD-A-AAR-01-RF-00-0000-02
RC BEAM 300X700MM
12 GA MIN. GALVANIZED
WIRE HANGER (TYP.)
GALVANISED STEEL STUD
ALUMINUM CANOPY
CHANNEL SUPPORT BRACKET
12 GA MIN. GALVANIZED
(FINAL DRAWING AND DETAIL SHALL BE AS PER APPROVED VENDOR)
WIRE HANGER (TYP.)
INTERMEDIATE CHANNEL
ADJUSTABLE SPRING CLIP
FURRING CHANNEL
04-GF-01
CONCRETE BLOCK WITH CEMENT EL 105.800 PREFORMED WIRE CLIP
50
ROOFING SYSTEM
(AS PER APPROVED MATERIAL)
CONCRETE SLAB
3) ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CLIENT AND MUST NOT BE DUPLICATED WITHOUT THE WRITTEN PERMISSION OF THE CLIENT.
ROOF TOC
CHANDELIER LIGHT FIXING DETAIL CHANNEL SUPPORT BRACKET
48mm GALV STUD RIVETED
TO 48mm GALV STUD
SPANDREL PANEL
EL. +104.250
INTERMEDIATE CHANNEL
GLASS REINFORCED 25X25MM PERIMETER
CONCRETE (GRC) CORNICE ANGLE TRIM CLIENT CONSULTANT
PREFORMED WIRE CLIP
(AS PER APPROVED MATERIAL)
FURRING CHANNEL
500
SHUT NAIL CONNECTED SHUT NAIL CONNECTED 2 ACRYLIC PAINT ON MOISTURE RESISTANT
12.5MM THK GYPSUM BOARD
WITH CONCRETE SLAB WITH CONCRETE SLAB 305
04-GF-01 CONTRACTOR
200
ACRYLIC PAINT ON MOISTURE RESISTANT
NAS JV
12 GA MIN. GALVANIZED 12 GA MIN. GALVANIZED 12.5MM THK GYPSUM BOARD
EL 105.800
43 P.O. Box 4339, Riyadh 11491-Saudi Arabia
50
WIRE HANGER (TYP.) WIRE HANGER (TYP.) TOPR 1 Tel.: +)966-11 (408 51 00
1850
Fax.: +)966-11 (405 78 28
GRC CORNICE
92
DESIGN CONSULTANT
ADJUSTABLE SPRING CLIP ADJUSTABLE SPRING CLIP
SOFFIT WALL
1) DRAWINGS ARE NOT TO BE SCALED, DIMENSIONS ARE GIVEN.
75MM METAL STUD 75MM METAL STUD NACO, NETHERLANDS AIRPORT CONSULTANTS
105
CHANNEL SUPPORT BRACKET CHANNEL SUPPORT BRACKET 12.5MM THK GYPSUM BOARD
CONTRACT: S19091
43
EL 103.150
FCL STATUS: ISSUED FOR CONSTRUCTION
PERFORMED WIRE CLIP 75MM METAL RUNNER 75MM METAL RUNNER PERFORMED WIRE CLIP EL 105.800 DRAWING TITLE:
CEILING DETAIL
FURRING CHANNEL FURRING CHANNEL TOPR 1
61 70 78 2719
16MM THK FIRE RATED GYPSUM 16MM THK FIRE RATED GYPSUM SHEET S19091 DIB NASJV PK1 MOS IFC A AAR 04 GF 00 0001 02
255 NUMBER: PRJ
BOARD PANEL PAINTED BOARD PANEL PAINTED AREA COM PAC BLD DRW DISC SUB DIS EL FL PN SEQ REV.
SECTION - TYPICAL DETAIL 04 GRC CORNICE DETAIL - The contractor is to revise the ceiling design according to the approved final IA submittal. DESIGNED: - CALCULATION: -
D 1 : 10
2 1:5 CHECKED BY: S.T DRAWN: S.Y
APPROVED: S.R DATE: 31-JAN-2023
Do not scale.