TECHNICAL TRAINING MANUAL


MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME)
HYDRAULIC POWER
This document must be used for training purposes only

Under no circumstances should this document be used as a reference

It will not be updated.

All rights reserved


No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of AIRBUS S.A.S.
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER
Hydraulic System Users (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Hydraulic Power Level 2 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Circuit Identification and Routing (2) . . . . . . . . . . . . . . . . . . . . . . . . 32
Hydraulic System Warnings (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Green Hydraulic System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Blue Hydraulic System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Yellow Hydraulic System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Leak Measurement System Presentation (3) . . . . . . . . . . . . . . . . . . . 72
Hydraulic Reservoir Pressurizing SYS D/O (3) . . . . . . . . . . . . . . . . . 74
Hydraulic Reservoir Filling Presentation (2) . . . . . . . . . . . . . . . . . . . 78
Seal Drain System Presentation (2) . . . . . . . . . . . . . . . . . . . . . . . . . . 80
MAINTENANCE PRACTICE
Reservoir Depressurization (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Reservoir Filling (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
RAT Stowage and Servicing (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
RAT Test (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Hydraulic Leakage (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
U3T06191 - U1QT0M0

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) TABLE OF CONTENTS May 11, 2006


29 - HYDRAULIC POWER Page 1
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC SYSTEM USERS (1)


GREEN, BLUE, YELLOW USERS
The three independent hydraulic systems respectively supply the users
indicated on the diagram. Between these systems, the users are shared in
order to ensure the aircraft control, even if only one hydraulic system is
inoperative. On the blue hydraulic system, the Constant Speed
Motor/Generator (CSM/G) is used to provide aircraft electrical power in
case of emergency.

PRIORITY VALVES
In the event of low hydraulic pressure, the priority valves maintain the
operation of essential systems by cutting off hydraulic power to heavy
load users.
U3T06191 - U1QT0M0 - UM29P1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC SYSTEM USERS (1) May 10, 2006
29 - HYDRAULIC POWER Page 2
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29P1000000001

GREEN, BLUE, YELLOW USERS & PRIORITY VALVES

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC SYSTEM USERS (1) May 10, 2006
29 - HYDRAULIC POWER Page 3
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


It can be deployed automatically or manually depending on the failure
SYSTEM OVERVIEW conditions.
The RAT is locked when extended.
On the green system the normal source of pressure is the Engine Driven
An index lock mechanism will only permit RAT stowage if the blades
Pump (EDP) and as auxiliary source the Power Transfer Unit (PTU).
are properly aligned.
On the blue system the normal source of pressure is the electrical pump
It also prevents rotation when stowed. The index lock will release at
(E-Pump) and as auxiliary source the Ram Air Turbine (RAT).
approximately 5 degrees from the full extension position.
NOTE: The blue electric pump can be used as an auxiliary power source Extension is by spring force. Retraction (stowage) is by blue hydraulic
for maintenance purposes on ground. pressure.
On the yellow system the normal source of pressure is the Engine Driven Up lock release is by solenoid operation.
Pump (EDP) and as auxiliary sources the Power Transfer Unit (PTU) Down lock release is by hydraulic pressure.
and the electric pump (E- Pump).

NOTE: The yellow system also has a hand pump dedicated to cargo
door operation.
PTU
The Power Transfer Unit (PTU) is an auxiliary pressure supply for
either the green or yellow systems without transfer of fluid between
the two systems.
It operates automatically if there is a delta pressure of 500psi between
the green / yellow or yellow / green hydraulic systems.
U3T06191 - U1QT0M0 - UM29BA000000001

The side operating as a pump will take fluid from its associated
reservoir and provide an output through the PTU manifold to the HP
manifold.
The motor side is supplied from the HP manifold through the PTU
manifold, and is connected to the return system.
Each section of the PTU has a case drain connection to the return
system.
RAT
The Ram Air Turbine (RAT) is an auxiliary pressure supply for the
blue system, and for the emergency electrical power CSM / G.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 4
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SYSTEM OVERVIEW - PTU & RAT

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 5
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


SERVICING
RESERVOIR AIR PRESSURIZATION
All three reservoirs are pressurized to 50 psi to prevent pump
cavitations.
The non-return valves in each reservoir supply manifold, make sure
that the pressure will be maintained for up to 12 hours after engine
shutdown on ground, and for up to 3 hours following a failure of the
air supply in flight.
Each reservoir has a depressurization valve on its associated service
panel. For long time depressurization, a depressurization tool may be
installed on the depressurization valve.
A 77 psi pressure relief valve is installed onto the supply manifold at
each reservoir.
All tree reservoirs are pressurized from Engine 1 for normal supply
and the bleed air system for alternate supply at 43 psi.
The air pressurization manifold has a ground supply connection.
It is put into the blue hydraulic bay and regulates normal or ground
supply to 50 psi.
Cleanable filters have clogging indicators.
There are two water drains, one is automatic after engines and APU
shut down, and the other is manually operated.
U3T06191 - U1QT0M0 - UM29BA000000001

After maintenance on the hydraulic system, the reservoir pressurization


can be done via a pneumatic ground cart connected to the reservoir
pressure unit, the APU, or the pneumatic system ground connection.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 6
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - RESERVOIR AIR PRESSURIZATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 7
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


SERVICING (continued)
FLUID LEVEL CHECK
The following Aircraft Configuration is needed for a correct fluid
level check and servicing:
- the speed brakes and spoilers must be retracted,
- the thrust reversers stowed,
- the cargo doors closed,
- all system accumulators empty of fluid,
- the accumulators pre-charge pressure must be checked,
- the reservoirs pressurized with air,
- the landing gear must be in down position with the landing gear
doors closed (one door may be open),
- and the brake accumulator may be pressurized with fluid.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 8
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - FLUID LEVEL CHECK

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 9
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


SERVICING (continued)
RESERVOIR FILLING
Switch on the yellow electric pump to make sure that the brake
accumulator is pressurized, then switch the pump off.
Connect the selected servicing source to the green servicing panel.
When the panel hand pump is used, connect the hose to the hand pump
and insert it into the fluid container, and then install the pump handle.
The handle is stowed at the yellow servicing panel.
When the external pump is used, connect the lower filling port and
set the minimum flow, do not exceed 435 psi.
Then select the reservoir to be filled, confirming associated light is
ON, and fill with fluid to the upper end of the scale.

NOTE: Over filling the reservoir will result in an inadequate


pressurization.
The reservoir level is also affected by large changes in ambient
temperature. For every 10 °C change, the green volume changes by
0.85 Lt, the blue volume changes by 0.51 Lt, and the yellow volume
changes by 0.64 Lt.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 10
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - RESERVOIR FILLING

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 11
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


SERVICING (continued)
BLEEDING
If you have filled the reservoir after:
- maintenance,
- or removal/installation of large hydraulic components,
- or hydraulic fluid low level (loss of the hydraulic system),
- or high loss of hydraulic fluid,
Do the related bleeding procedure to make sure that the quantity of
hydraulic fluid in the system is correct.
After maintenance of the hydraulic system upstream of the EDP,
loosen the nut of the case drain hose so that the air (or hydraulic fluid
mixed with air bubbles) comes out of the connection. Check:
- make sure that the air pressure in the reservoir of the associated
hydraulic system is not less than 50 psi (if necessary, pressurize the
reservoir),
- read the gauge of the associated reservoir and make a note of the
fluid level,
- depressurize the reservoir of the associated hydraulic system,
- after 5 minutes, read the gauge again and make a note of the level,
- compare both levels,
- if the difference between both levels is more than 2 liters, do the
U3T06191 - U1QT0M0 - UM29BA000000001

bleeding procedures again until the result is satisfactory.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 12
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - BLEEDING

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 13
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


SERVICING (continued)
HIGH PRESSURE (HP), CASE DRAIN, AND LOW
PRESSURE (LP) FILTERS
The three Hydraulic Systems have:
- a HP filter in the pressure line, in the reservoir filling system, and
the normal braking system,
- an LP filter in the return line,
- a case drain filter in the case drain line of the EDP's.
The HP and the case drain filters have a red clogging indicator, which
pops out when the filter is clogged (dirty).
The LP filters have a replaceable filter elements and a by-pass system.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 14
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - HIGH PRESSURE (HP), CASE DRAIN, AND LOW PRESSURE (LP) FILTERS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 15
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - HIGH PRESSURE (HP), CASE DRAIN, AND LOW PRESSURE (LP) FILTERS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 16
SINGLE AISLE TECHNICAL TRAINING MANUAL

This Page Intentionally Left Blank


U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 17
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


SERVICING (continued)
ACCUMULATORS
Each system has an accumulator, located in their associated hydraulic
bays.
The yellow brake system has an accumulator for emergency braking
and parking brake.
The nitrogen pre-charge is adjusted at the accumulator in accordance
to the ambient temperature.
On system pressurization the accumulators will each take
approximately 1 Lt. of fluid.
Each accumulator has a nitrogen pressure indicator.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 18
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - ACCUMULATORS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 19
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


SERVICING (continued)
EXTERNAL LEAK TEST OF COMPONENTS
A leak is the quantity of fluid that comes out of a component and that
is sufficient to become a drop or drops, or will possibly become a
drop of approximately 20 drops =1 cc, and 75600 drops =1 gallon.
A leakage is a quantity of fluid on the surface of a component that is
not sufficient to become a drop.
A stain is an area on the surface of a component that has a different
color. It is usually caused when fluid leakage becomes dry on the
component surface after a high temperature operation.
For a correct analysis of component leak rates, you must obey the
subsequent steps:
- the seal obtained at hydraulic tube connections is obtained on
metal-to-metal surfaces. If a leak cannot be stopped by tightening the
nut to the specified torque, the joint is probably defective and should
be repaired.
- when possible, activate components for some cycles before carrying
out the external leakage check.
- dynamic seals are easy to examine for leakage while in the static
condition because pistons, slide valves and swivel joints move only
during a short time interval. Many components cannot be obviously
U3T06191 - U1QT0M0 - UM29BA000000001

monitored during operation.


- by following the AMM procedure operate the related component,
- after operation, inspect the component. If there is a sign of any
external leakage, compare the quantity of leakage with the values
given in the AMM table for specified limits.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 20
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

SERVICING - EXTERNAL LEAK TEST OF COMPONENTS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 21
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


DAILY CHECKS
During the daily check the reservoirs quantity indication on the ECAM
display unit have to be checked.
In case of incorrect findings during this check, the related AMM tasks
have to be done to restore the system to normal status or to readjust
quantities and pressures to nominal values.
In case of hydraulic fluid level find below normal, the system needs to
be refilled using the Hand Pump or a Hydraulic Service Cart.
In case of hydraulic fluid level find above normal, the system needs to
be drained.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 22
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

DAILY CHECKS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 23
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


MEL/DEACTIVATION
The fluid quantity have to be checked on the reservoir direct reading gage
prior to each flight.
The LO LVL Warning has to be checked operative before the first flight.
The air pressure have to be checked on the reservoir direct reading gage
prior to each flight.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 24
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

MEL/DEACTIVATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 25
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


MAINTENANCE TIPS
PTU
PTU inhibition is achieved by closing the solenoid valves (they are
fail safe open) at the PTU manifolds, and for maintenance actions by
also disconnecting the coupling on the yellow (right) side of the unit.
The PTU operation is inhibited at first engine start and during cargo
door operation.

NOTE: At the second engine start, the inhibition is removed when


the second engine master switch is set to ON then the PTU
will operate momentarily for self test purpose.
RAT
The RAT can be tested on ground by using the Ground Check Module.
A RAT retraction module controls the RAT stowage procedure, it is
located on the blue servicing panel.

NOTE: To avoid any extension during maintenance work a RAT


safety tool must be installed.
SAFETY PRECAUTIONS
U3T06191 - U1QT0M0 - UM29BA000000001

To prevent an unwanted operation of the PTU, the isolation coupling


must be disconnected.
Keep the RAT extension area clear of ground equipment and
personnel. Install the RAT safety device before to work in the RAT
area.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 26
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE TIPS - PTU ... SAFETY PRECAUTIONS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 27
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


MAINTENANCE TIPS (continued)
TIGHTENING TORQUES
Before you torque a component or connection, obey the precautions
and procedures given in the tightening practices for hydraulic
connection procedure in the AMM Chapter 20.
The tightening torques are given in the AMM tables chapter 20.
When you use an adapter, the values shown on the dial of the torque
wrench is not the applied value .To get the correct value, the formula
given on the next picture must be applied.
The drawing shows as an example the tightening torque for
HARRISSON and PERMASWAGE sleeve nuts and in-line-check
valves and how to use a torque wrench and adapter.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 28
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE TIPS - TIGHTENING TORQUES

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 29
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC POWER LEVEL 2 (2)


'A' CHECK ITEMS
During the 'A' check:
- the fluid level on the main hydraulic reservoir indicators have to be
checked,
- the air pressure of main hydraulic power reservoir have to be checked
using the reading gage,
- the clogging indicators on Engine Driven Pump (EDP) case drain filter
(pop out not protruding) have to be checked,
- the nitrogen charge pressure on hydraulic power Accumulators have to
be checked using the direct reading gage.
In case or incorrect findings during these checks, the related AMM tasks
have to be done to restore the system to normal status or to readjust
quantities and pressures to nominal values.
U3T06191 - U1QT0M0 - UM29BA000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 30
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29BA000000001

'A' CHECK ITEMS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC POWER LEVEL 2 (2) May 10, 2006
29 - HYDRAULIC POWER Page 31
SINGLE AISLE TECHNICAL TRAINING MANUAL

CIRCUIT IDENTIFICATION AND ROUTING (2)


PIPE ROUTING
The A/C has three hydraulically independent systems: blue, green, yellow.
There are no hydraulic pipes in the passenger cabin or flight compartment.
U3T06191 - U1QT0M0 - UM29D1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 32
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D1000000001

PIPE ROUTING

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 33
SINGLE AISLE TECHNICAL TRAINING MANUAL

CIRCUIT IDENTIFICATION AND ROUTING (2)


PIPE IDENTIFICATION
Each pipe is identified by a self-adhesive label, which indicates:
- the part number of the pipe,
- the identification of the pipe as a hydraulic pipe, its function with black
dots and the direction of the fluid flow with yellow and blue fields,
- an identification of the system comprising a color code and a number
1, 2 or 3 respectively indicating the Green, Blue, or Yellow system.
U3T06191 - U1QT0M0 - UM29D1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 34
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D1000000001

PIPE IDENTIFICATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 35
SINGLE AISLE TECHNICAL TRAINING MANUAL

CIRCUIT IDENTIFICATION AND ROUTING (2)


COMPONENT IDENTIFICATION
Each hydraulic component is identified by a placard affixed on the
structure near to it, which gives its Functional Item Number (FIN) and
its designation.
U3T06191 - U1QT0M0 - UM29D1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 36
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D1000000001

COMPONENT IDENTIFICATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 37
SINGLE AISLE TECHNICAL TRAINING MANUAL

CIRCUIT IDENTIFICATION AND ROUTING (2)


CONNECTIONS
The most common connections in the hydraulic system are shown below.
There are two types of connections:
- permanent connections or permaswage,
- removable connections or standard straight or special fittings.
The manifolds have bobbin type connections for some components. The
bobbins are equipped with a square seal on the component side and an
O-ring on the manifold side.
U3T06191 - U1QT0M0 - UM29D1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 38
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D1000000001

CONNECTIONS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) CIRCUIT IDENTIFICATION AND ROUTING (2) May 10, 2006
29 - HYDRAULIC POWER Page 39
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC SYSTEM WARNINGS (3)


the PTU FAULT lights are in amber. The failure is shown amber on the
G+Y SYS LO PR EWD associated to indications on the ECAM HYDraulic page.
In case of dual pump failure on ground with engines running, the aural Y ELEC PUMP OVHT
warning sounds, the MASTER WARNing and the ENG 1&2 PUMP
FAULT lights come on. The failure is shown red on the EWD associated In case of yellow electric pump overheat the aural warning sounds, the
to indications on the ECAM HYDraulic page. MASTER CAUT comes on and the ELEC PUMP FAULT light is amber.
The failure is shown amber on the EWD associated to indications on the
Y ELEC PUMP LO PR ECAM HYDraulic page.
In case of reservoir LP the aural warning sounds, the MASTER CAUT PTU FAULT
and the ELECT PUMP FAULT light come on. The failure is shown
amber on the EWD associated to indications on the ECAM HYDraulic In case of PTU fault the aural warning sounds and the MASTER CAUT
page. There is Yellow system LP if pressure is lower than 1450 psi (100 comes on. The failure is shown amber on the EWD associated to
bar). Reset if pressure is greater than 1750 psi (120 bar) with: indications on the ECAM HYDraulic page. The PTU is not running in
- Y ELEC PUMP P/B at ON, case of GREEN or YELLOW system LO PR, when at least one engine
- Y ENG PUMP and PTU not available. is running.

B RSVR LO LVL RAT FAULT


In case of reservoir low level the aural warning sounds, the MASTER In case of Ram Air Turbine (RAT) fault the aural warning sounds and
CAUTion and the ELEC PUMP FAULT lights come on. The failure is the MASTER CAUT and PTU FAULT lights come on. The failure is
shown amber on the EWD associated to indications on the ECAM shown amber on the EWD associated to indications on the ECAM
HYDraulic page. HYDraulic page. A RAT fault occurs in case of:
U3T06191 - U1QT0M0 - UM29W1000000001

- pressure present in the RAT stowing actuator,


G RSVR LO AIR PR - RAT pump LP.
In case of reservoir low air pressure the aural warning sounds, the G ENG 1 PUMP LO PR
MASTER CAUT, the ENG 1 PUMP and the Power Transfer Unit (PTU)
FAULT lights come on. The failure is shown amber on the EWD In case of green engine1 pump LP fault the aural warning sounds, the
associated to indications on the ECAM HYDraulic page. MASTER CAUT comes on and the ENG 1 PUMP light is amber. The
green hydraulic pressure decreases below a given differential pressure
Y RSVR OVHT between the green and yellow systems. If the green/yellow differential
pressure exceeds 500 psi (35 bar), the PTU runs. Flight phases 1 and 10
In case of reservoir overheat air pressure the aural warning sounds, the
are inhibited because the A/C is on the ground with no engines running.
MASTER CAUT comes on and the ENG PUMP, the ELEC PUMP and
The related engine shutdown also inhibits flight phases 2 and 9.
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC SYSTEM WARNINGS (3) May 10, 2006
29 - HYDRAULIC POWER Page 40
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29W1000000001

G+Y SYS LO PR ... G ENG 1 PUMP LO PR

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC SYSTEM WARNINGS (3) May 10, 2006
29 - HYDRAULIC POWER Page 41
SINGLE AISLE TECHNICAL TRAINING MANUAL

GREEN HYDRAULIC SYSTEM D/O (3)


mode. Case drain filter clogging indication: P = 87 ± 8.7 psi (6 ± 0.6
GENERAL bar).
Most of the system components are installed in the MLG compartment. GROUND COUPLINGS
RESERVOIR The ground service panel has two connectors used to pressurize the green
hydraulic system from a ground cart, a selector valve, two connectors
The reservoir has a direct reading gauge, a quantity indicator and a low
and a hand pump used for hydraulic reservoir refilling.
level switch for ECAM indicating and warning.
There are three levels:
- normal fill level: 14 l. (3.7 US gal),
- maximum gaugeable level: 18 l. (4.76 US gal),
- low level warning: 3.0 ± 0.4 l. (0.79 ± 0.1 US gal).

RESERVOIR PRESSURIZATION
The reservoir is normally pressurized with air to prevent cavitation of
the pumps. The reservoir is pressurized to 50 psi (3.45 bar) and is sealed
to hold the pressure when there is no air supply. The threshold of the LP
switch is 22 psi (1.52 bar). The threshold of the pressure relief valve is
77 psi (5.3 bar).

FIRE VALVE
The green system fire valve installed in the LH wing, inboard of the
U3T06191 - U1QT0M0 - UM29D2000000001

pylon, is controlled by ENG 1 FIRE P/B. When the valve closes, it stops
the supply of fluid to the Engine Driven Pump (EDP).

EDP
The EDP is attached to the accessory gearbox. A solenoid valve controlled
by the ENG 1 PUMP P/B selects the pressurized or depressurized mode.
The EDP cooling and lubricating flow goes through the case drain filter
installed in the return circuit. Pump outlet pressure is 3000 psi (206 bar)
at zero flow. The EDP includes a blocking valve which isolates the pump
from the hydraulic system when the pump operates in depressurized

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 42
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D2000000001

GENERAL ... GROUND COUPLINGS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 43
SINGLE AISLE TECHNICAL TRAINING MANUAL

GREEN HYDRAULIC SYSTEM D/O (3)


PTU
The Power Transfer Unit (PTU) will run automatically when the
differential pressure between the green and yellow circuits is greater than
500 psi (34.5 bar). The PTU is inhibited on ground, for cargo door
operation and during the first engine start, if parking brake is set on or
nose wheel steering is disconnected for towing.
U3T06191 - U1QT0M0 - UM29D2000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 44
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D2000000001

PTU

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 45
SINGLE AISLE TECHNICAL TRAINING MANUAL

GREEN HYDRAULIC SYSTEM D/O (3)


PRESSURE SWITCH ACCUMULATOR
The accumulator acts as a damper for small changes. It also makes a
The EDP pressure switch monitors the EDP outlet pressure for ECAM supply of fluid available in case of any demand. The accumulator is
indications. The threshold of the pressure switch is 1740 psi (120 bar). precharged with nitrogen to 1885 psi (130 bar) at 20°C. It holds 1.1l
(0.29 US gal) of total volume of fluid when it is full.
NOTE: A check valve downstream of the pump stops the fluid flow to
the pump if the system is pressurized by the PTU. SAMPLING VALVE
A sampling valve is provided on the HP manifold.
HP MANIFOLD
PRESSURE RELIEF VALVE
The High Pressure (HP) manifold supplies the PTU manifold and the
The system relief valve connects the HP circuit to the return circuit
leak measurement manifold.
in case of overpressure. The relief valve opens at 3436 psi (237 bar)
PRESSURE SWITCHES and closes at 3190 psi (220 bar).
The signals from both pressure switches at the HP manifold are sent
to the Flight Control Computers (FCCs), to the Braking/Steering
Control Unit (BSCU), the ECAM will receive information from one
of the two switches for LP indication, and to the Flight Augmentation
Computer (FAC). The threshold of the pressure switches is 1450 psi
(99.5 bar).
PRESSURE TRANSDUCER
The pressure transducer provides data for pressure indication on the
U3T06191 - U1QT0M0 - UM29D2000000001

ECAM and sends information to Elevator Aileron Computers (ELACs)


1 and 2.
LEAK MEASUREMENT VALVE
The leak measurement valve isolates the primary flight controls when
the guarded LEAK MEASUREMENT VALVES P/B on the
maintenance panel is set to OFF.
HP FILTER
The HP filter has a clogging indicator. The clogging indicator operates
when the differential pressure is higher than 87 ± 8.7 psi (6 ± 0.6 bar).

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 46
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D2000000001

PRESSURE SWITCH & HP MANIFOLD

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 47
SINGLE AISLE TECHNICAL TRAINING MANUAL

GREEN HYDRAULIC SYSTEM D/O (3)


LEAK MEASUREMENT MANIFOLD
The leak measurement manifold supplies the flight controls of the RH
wing, LH wing and tail section via three outputs. After closing the related
leak measurement valve, operating manually a spool valve allows the
associated section to be supplied for leak measurement testing.

PTU MANIFOLD
The PTU manifold is composed of three different valves:
- the normal braking selector valve which cuts the hydraulic supply to
the normal brakes,
- the solenoid valve installed in the PTU supply line which stops the PTU
operation,
- the priority valve which makes sure that all available hydraulic pressure
is sent to the primary flight controls if pressure in the system is reduced.

RETURN MANIFOLD
The return manifold comprises:
- one return filter with a clogging indicator,
- one temperature transmitter which has one temperature switch and two
temperature transducers.
U3T06191 - U1QT0M0 - UM29D2000000001

The bypass operates when the differential pressure across the filter is
more than 29 ± 2.35 psi (2 ± 0.16 bar). The temperature switch and
temperature transducers send data to the ECAM for warnings.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 48
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D2000000001

LEAK MEASUREMENT MANIFOLD ... RETURN MANIFOLD

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) GREEN HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 49
SINGLE AISLE TECHNICAL TRAINING MANUAL

BLUE HYDRAULIC SYSTEM D/O (3)


RESERVOIR
The reservoir has a direct reading gauge, a quantity indicator and a low
level switch for ECAM indicating and warning. Normal fill level: 6 l
(1.58 US gal). Maximum gaugeable level: 8 l (2.11 US gal). Low level
warning: between 2.0 and 2.3 l (0.52 and 0.6 US gal).

RESERVOIR PRESSURIZATION
The reservoir is normally pressurized with air to prevent pump cavitation.
The reservoir is pressurized to 50 psi (3.43 bar) and is sealed to hold the
pressure when there is no air supply. The threshold of the air pressure
switch is 22 psi (1.52 bar). The threshold of the air pressure relief valve
is 77 psi (5.3 bar).

ELECTRIC PUMP
With the ELECtric (ELEC) PUMP P/B set to AUTO, the blue electric
pump will run, if one engine is running, or the BLUE PUMP OverRiDe
(OVRD) P/B is set to ON, or NLG is not compressed and AC power is
available from the APU. With the last condition, at touchdown a time
delay relay maintains the pump operation for two minutes after NLG
compression. The pump outlet pressure is 3000 psi (206 bar) at zero flow.
U3T06191 - U1QT0M0 - UM29D3000000001

A temperature switch sends a signal to the ECAM if the pump body


temperature exceeds 165°C. The electric pump cooling and lubricating
flow goes through the case drain filter installed in the return circuit.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 50
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D3000000001

RESERVOIR ... ELECTRIC PUMP

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 51
SINGLE AISLE TECHNICAL TRAINING MANUAL

BLUE HYDRAULIC SYSTEM D/O (3)


CURRENT TRANSFORMER AND PHASE UNBALANCE
DETECTOR
The system has a current transformer and a phase unbalance detector
which protect the electric circuit from the electric pump. When there is
a fault, the detector gets a signal from the current transformer. It uses this
signal to stop the supply of power to relay and thus stop the motor. When
the unit has operated, it stays in that condition until it is set again. This
happens automatically when the supply of power to the unit is stopped
(through operation of P/BSW HYD/BLUE/ELEC PUMP) and then started
again (and there is no fault signal from the current transformer).
U3T06191 - U1QT0M0 - UM29D3000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 52
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D3000000001

CURRENT TRANSFORMER AND PHASE UNBALANCE DETECTOR

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 53
SINGLE AISLE TECHNICAL TRAINING MANUAL

BLUE HYDRAULIC SYSTEM D/O (3)


RAM AIR TURBINE LEAK MEASUREMENT
The leak measurement valve isolates the flight controls when the
The Ram Air Turbine (RAT) is deployed automatically if all AC electrical guarded LEAK MEASUREMENT VALVES P/B on the maintenance
power sources are lost at speeds greater than 100 kts, or manually by panel is set to OFF.
using either one of the guarded P/Bs.
HP FILTER
PRESSURE SWITCH The HP filter has a clogging indicator. The clogging indicator operates
The pressure switch monitors the electric pump pressure for ECAM when the differential pressure is higher than 87 ± 8.7 psi (6 ± 0.6 bar).
indications. The threshold of the pressure switch is 1450 psi (99.5 bar). PRIORITY VALVE
A check valve stops the flow of fluid to the electric pump if the system The priority valve makes sure that all available hydraulic pressure is
is pressurized by the RAT. sent to the primary flight controls if pressure in the system is reduced.
HIGH PRESSURE MANIFOLD The threshold of the priority valve is 1842 psi (127 bar).
PRESSURE RELIEF VALVE
The High Pressure (HP) manifold is composed of:
- two pressure switches, The pressure relief valve connects the HP circuit to the return circuit
- a pressure transducer, in case of over pressure. The relief valve opens at 3436 psi (237 bar)
- a leak measurement valve, and closes at 3190 psi (220 bar).
- a HP filter, SAMPLING VALVE
- a priority valve,
A sampling valve is installed on the HP manifold.
- a pressure relief valve,
- a sampling valve. ACCUMULATOR
U3T06191 - U1QT0M0 - UM29D3000000001

PRESSURE SWITCHES The accumulator acts as a damper for small changes. It also makes a
The signals from both HP manifold pressure switches are sent to the supply of fluid available in case of demand. The accumulator is
ECAM system and to the Flight Control Computers (FCCs). The precharged with nitrogen to 1885 psi (130 bar) at 20°C. It holds 1.1 l
threshold of the pressure switches is 1450 psi (99.5 bar). (0.29 US gal) of total volume of fluid when it is full.
PRESSURE TRANSDUCER
The pressure transducer gives data for pressure indication on the
ECAM and sends information to ELevator Aileron Computers
(ELACs) 1 and 2.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 54
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D3000000001

RAM AIR TURBINE ... ACCUMULATOR

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 55
SINGLE AISLE TECHNICAL TRAINING MANUAL

BLUE HYDRAULIC SYSTEM D/O (3)


LEAK MEASUREMENT MANIFOLD
The leak measurement valve block supplies the flight controls of the RH
wing, the LH wing and tail section via three outputs. After closing the
related leak measurement valve, operating manually a spool valve lets
the associated section of the flight controls be supplied for leak
measurement test.

RETURN MANIFOLD
The return manifold comprises:
- one return filter with a clogging indicator,
- one temperature transmitter which has one temperature switch and two
temperature transducers.
The bypass operates when the differential pressure across the filter is
more than 29 ± 2.35 psi (2 ± 0.16 bar). The temperature switch and probes
send data to the ECAM for indication and warnings.

GROUND COUPLINGS
On ground it is possible to pressurize the blue hydraulic system from a
ground power unit.
U3T06191 - U1QT0M0 - UM29D3000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 56
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D3000000001

LEAK MEASUREMENT MANIFOLD ... GROUND COUPLINGS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) BLUE HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 57
SINGLE AISLE TECHNICAL TRAINING MANUAL

YELLOW HYDRAULIC SYSTEM D/O (3)


mode. Case drain filter clogging indication: P = 87 ± 8.7 psi (6 ± 0.6
GENERAL bar).
Most of the system components are installed in the yellow hydraulic GROUND COUPLINGS
compartment, set in the RH belly fairing, FWD of the MLG compartment.
On the ground it is possible to pressurize the yellow hydraulic system
RESERVOIR from a ground power unit.
The reservoir has a direct reading gauge, a quantity indicator and a low
level switch for ECAM indications and warnings.
There are three levels:
- normal fill level: 12 l. (3.17 US gal),
- maximum gaugeable level: 18 l. (4.76 US gal),
- low level warning: 3.0 ± 0.4 l. (0.79 ± 0.1 US gal).

RESERVOIR PRESSURIZATION
The reservoir is normally pressurized with air to prevent cavitation of
the pumps. The reservoir is pressurized to 50 psi (3.45 bar) and is sealed
to hold the pressure when there is no air supply. The threshold of the LP
switch is 22 psi (1.52bar).

FIRE VALVE
The yellow system fire valve installed in the RH wing, inboard of the
U3T06191 - U1QT0M0 - UM29D4000000001

pylon, is controlled by ENG 2 FIRE P/B. When the valve closes, it stops
the supply of fluid from the reservoir to the Engine Driven Pump (EDP).

EDP
The EDP is attached to the accessory gearbox. A solenoid valve controlled
by the ENG 2 PUMP P/B selects the pressurized or depressurized mode.
The EDP cooling and lubricating flow goes through the case drain filter
installed in the return circuit. Pump outlet pressure is 3000 psi (206 bar)
at zero flow. The EDP includes a blocking valve which isolates the pump
from the hydraulic system when the pump operates in depressurized

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 58
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D4000000001

GENERAL ... GROUND COUPLINGS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 59
SINGLE AISLE TECHNICAL TRAINING MANUAL

YELLOW HYDRAULIC SYSTEM D/O (3)


PTU
The Power Transfer Unit (PTU) will run automatically when the
differential pressure between the green and yellow circuits is greater than
500 psi (34.5 bar). The PTU is inhibited on ground, for cargo door
operation. And during the first engine, if parking brake is set on or nose
wheel steering is disconnected for towing.
U3T06191 - U1QT0M0 - UM29D4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 60
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D4000000001

PTU

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 61
SINGLE AISLE TECHNICAL TRAINING MANUAL

YELLOW HYDRAULIC SYSTEM D/O (3)


PRESSURE SWITCH
A pressure switch monitors the EDP outlet pressure for ECAM
indications. The threshold of the pressure switch is 1740 psi (120 bar).

NOTE: A check valve downstream of the pump stops the fluid flow to
the pump if the system is pressurized by the PTU or by the
yellow electric pump and the pressure supplied by the EDP is
lower.

ELECTRIC PUMP
The yellow electric pump runs if the ELEC PUMP P/B is set to ON, or
if a cargo door selector is operated. The electric pump cooling and
lubricating flow goes through the return filter. In case of cargo door
operation, the PTU is inhibited, the yellow leak measurement valve is
closed and a signal is sent to the Slat Flap Control Computer (SFCC) 2
to prevent flaps movement. A check valve downstream of the pump stops
the fluid flow to the pump if the system is pressurized from the EDP or
the PTU.
U3T06191 - U1QT0M0 - UM29D4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 62
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D4000000001

PRESSURE SWITCH & ELECTRIC PUMP

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 63
SINGLE AISLE TECHNICAL TRAINING MANUAL

YELLOW HYDRAULIC SYSTEM D/O (3)


ELECTRIC PUMP (continued)
CURRENT TRANSFORMER AND PHASE UNBALANCE
DETECTOR
The system has a current transformer and a phase unbalance detector
which protect the electric circuit of the electric pump. When there is
a fault, the detector gets a signal from the current transformer. It uses
this signal to stop the supply of power to relay and thus stop the motor.
When the unit has operated, it stays in that condition until it is set
again. This happens automatically when the supply of power to the
unit is stopped (through operation of P/BSW HYD/YELLOW/ELEC
PUMP) and then started again (and there is no fault signal from the
current transformer).
U3T06191 - U1QT0M0 - UM29D4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 64
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D4000000001

ELECTRIC PUMP - CURRENT TRANSFORMER AND PHASE UNBALANCE DETECTOR

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 65
SINGLE AISLE TECHNICAL TRAINING MANUAL

YELLOW HYDRAULIC SYSTEM D/O (3)


HAND PUMP
The hand pump is installed on the ground service panel of the yellow
system and is used for manual cargo door operation only. On ground,
when no electrical power is available, the hand pump can be used to open
or close the cargo doors.
U3T06191 - U1QT0M0 - UM29D4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 66
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D4000000001

HAND PUMP

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 67
SINGLE AISLE TECHNICAL TRAINING MANUAL

YELLOW HYDRAULIC SYSTEM D/O (3)


HP MANIFOLD PRESSURE RELIEF VALVE
The system relief valve connects the HP circuit to the return circuit
The HP manifold supplies the PTU manifold and the leak measurement in case of overpressure. The relief valve opens at 3436 psi (237 bar)
manifold. and closes at 3190 psi (220 bar).
PRESSURE SWITCHES
ACCUMULATOR
The signals from both HP manifold pressure switches are sent to the
ECAM system, to the Flight Control Computers (FCCs) and to the The accumulator acts as a damper for small changes. It also acts as a
Flight Augmentation Computer (FAC) 2. The threshold of the pressure supply of fluid available in case of request. The accumulator is precharged
switches is 1450 psi (99.5 bar). with nitrogen to 1885 psi (130 bar) at 20°C. It holds 1.1l (0.29 US gal)
of total volume of fluid when it is full.
PRESSURE TRANSDUCER
The pressure transducer gives data for pressure indication on the
ECAM and sends information to ELevator Aileron Computers
(ELACs) 1 and 2.
LEAK MEASUREMENT VALVE
The leak measurement valve isolates the primary flight controls when
the guarded LEAK MEASUREMENT VALVES P/B on the
maintenance panel is set to OFF. The solenoid valve is automatically
closed if the yellow electric pump is energized by using cargo door
selectors. This is to prevent any movement of the flight controls.
U3T06191 - U1QT0M0 - UM29D4000000001

HP FILTER
The High Pressure (HP) filter has a clogging indicator. The clogging
indicator operates when the differential pressure is higher than 87 ±
8.7 psi (6 ± 0.6 bar).
SAMPLING VALVE
A sampling valve is installed on the HP manifold.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 68
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D4000000001

HP MANIFOLD & ACCUMULATOR

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 69
SINGLE AISLE TECHNICAL TRAINING MANUAL

YELLOW HYDRAULIC SYSTEM D/O (3)


LEAK MEASUREMENT MANIFOLD
The leak measurement manifold supplies the flight controls of the RH
wing, LH wing and tail section via three outputs. Operating manually a
spool valve lets the associated section of the flight controls be supplied
for leak measurement testing.

PTU MANIFOLD
The PTU manifold is composed of one disconnection and two different
valves.
QUICK DISCONNECT
The quick disconnect is used for maintenance operations to prevent
PTU operation.
SOLENOID VALVE
The solenoid valve installed in the PTU supply line, stops the PTU
operation.
PRIORITY VALVE
The priority valve makes sure that all available hydraulic pressure is
sent to the primary flight controls if pressure in the system is reduced.
U3T06191 - U1QT0M0 - UM29D4000000001

RETURN MANIFOLD
The return manifold comprises:
- one return filter with a clogging indicator,
- one temperature switch and two temperature transducers.
The bypass operates when the differential pressure across the filter is
more than 29 ± 2.35 psi (2 ± 0.16 bar). The temperature switch and probes
send data to the ECAM for indication and warnings.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 70
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D4000000001

LEAK MEASUREMENT MANIFOLD ... RETURN MANIFOLD

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) YELLOW HYDRAULIC SYSTEM D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 71
SINGLE AISLE TECHNICAL TRAINING MANUAL

LEAK MEASUREMENT SYSTEM PRESENTATION (3)


GENERAL FULL SYSTEM CHECK
The return flow of a hydraulic system is equal to the user's demand flow Once the hydraulic system is pressurized from the ground cart, make sure
plus the permanent internal leakage. The flight controls users are that the ELevator Aileron Computers (ELACs), Spoiler Elevator
permanently supplied through leak measurement valves. These valves Computers (SECs) and Flight Augmentation Computer (FAC) 2 are set
are electrically powered to the closed position for leak measurement test. to ON to supply the hydraulic users. The flight controls surfaces must be
The full system is checked during the internal leakage. Internal leakages kept in the neutral position. The full system check is carried out by
are measured for each group of users through manually operated shut-off successively checking the four sections of the hydraulic system with the
valves. related leakage measurement valve in the closed position. The flow
indicated must be compared to the theoretical one and if the flow is over
NOTE: Note: Even with users at neutral, there is a permanent flow. If the limit the failed component belongs to this group of users.
the permanent flow is too high the related system operation
will be affected. NOTE: Note: The internal leakage check has to be done with the
hydraulic fluid at its normal working temperature.
HYDRAULIC SYSTEM TEST
COMPONENT CHECK
To test a complete hydraulic system, a hydraulic ground cart with a flow
meter has to be used to pressurize the circuit. The internal leakage flow Each type of hydraulic component has a maximum internal leakage limit
rate is indicated by the flow meter. If the flow rate is too high, a full permitted. If the internal leakage is too high, the faulty component must
system check has to be carried out to find out the faulty group of hydraulic be identified and replaced. High leakage rate causes an increase of
users. The hydraulic users are RH wing, LH wing, tail section and central component temperature. If a servo control is faulty, it must be
section. disconnected and the related hydraulic section rechecked. If the internal
leakage rate is now within the limits, the servo control is confirmed as
U3T06191 - U1QT0M0 - UM29P2000000001

WARNING: BEFORE STARTING THE TEST, MAKE SURE THAT defective.


ALL SERVO CONTROLS ARE IN THEIR NEUTRAL
POSITION AND THAT THE SPOILERS ARE NOTE: Note: The total leakage of the components within a section
RETRACTED. DO NOT FORGET TO DISCONNECT must be less than the maximum permitted for that section. The
THE ISOLATION COUPLING OF THE POWER total of sections leakages must not be more than the leakage
TRANSFER UNIT (PTU) TO PREVENT INADVERTENT permitted for the complete system.
PRESSURIZATION OF THE GREEN SYSTEM BY THE
PTU.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) LEAK MEASUREMENT SYSTEM PRESENTATION (3) May 10, 2006
29 - HYDRAULIC POWER Page 72
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29P2000000001

GENERAL ... COMPONENT CHECK

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) LEAK MEASUREMENT SYSTEM PRESENTATION (3) May 10, 2006
29 - HYDRAULIC POWER Page 73
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC RESERVOIR PRESSURIZING SYS D/O (3)


GENERAL GROUND CONNECTOR
An air pressure system is provided to pressurize each hydraulic reservoir Pressurized air from a ground supply cart goes directly to the reservoir
in order to ensure adequate fluid supply to the pumps. Each reservoir is pressurization unit through a ground connector.
pressurized by air at 50 psi (3.5 bar). The system also remains airtight in
the event of pressurization system failure or after engine shutdown. FILTER

SOURCES A filter fitted with a clogging indicator is installed in the reservoir


pressurization unit to filter the air from the different supply sources.
The pressure sources are engine 1, via a restrictor or both engines and
the APU, via the pneumatic manifold. The pressure sources are: WATER SEPARATOR
- the engine 1 High Pressure (HP) compressor for usual operation,
A water separator is installed on the reservoir pressurization unit. It makes
- the pneumatic system in case of loss of engine 1,
sure that the air delivered to the reservoirs is clear of any fluid. There are
- the ground supply.
two drain valves that prevent freezing of the water in the reservoir
RESTRICTOR pressurization unit. One is an automatic drain valve that is opened after
each engine or APU shutdown; the other one is a manual self-sealing
A restrictor limits the airflow and reduces the temperature of the HP air drain valve.
to a satisfactory level. The restrictor also prevents too much bleed air
leakage in case of a leak downstream of the restrictor. RESERVOIR CHECK VALVE

RESERVOIR PRESSURIZATION UNIT Downstream of the reservoir pressurization unit, the air supply is divided
into three flows to supply the reservoirs through their related check valve.
The reservoir pressurization unit controls the pressure of the air supplied The green and yellow check valves are installed between the floor beams
U3T06191 - U1QT0M0 - UM29D5000000001

to the reservoirs. above the hydraulic bay and the blue one is installed in the aft cargo
compartment.
PRESSURE REDUCING VALVE
PRESSURE GAGE
A pressure reducing valve is fitted to the reservoir pressurization unit. In
normal operation, the delivery pressure of engine 1 has priority over the An air pressure gage is installed on each hydraulic reservoir to indicate
pressure supply from the pneumatic manifold. The pressure reducing the actual pressure. The pressure switch generates LOW AIR PRESS
valve outlet pressure is 50 psi (3.5bar). Two check valves prevent any warning if the pressure is less than 22 psi (1.52 bar).
reverse flow.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC RESERVOIR PRESSURIZING SYS D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 74
SINGLE AISLE TECHNICAL TRAINING MANUAL

PRESSURE RELIEF VALVE


A pressure relief valve, installed on each reservoir, relieves pressure to
the atmosphere in the event of a system overpressure. The threshold of
the pressure relief valve is 77 psi (5.3 bar).

MANUAL DEPRESSURIZATION VALVE


A manual depressurization valve is fitted on each ground service panel
to depressurize each reservoir.

WARNING: WHEN USING THE MANUAL DEPRESSURIZATION


VALVE, PUT ON EYE PROTECTION AND KEEP
AWAY FROM THE OUTLET OF THE VALVE. THE AIR
CAN BE HOT AND CONTAIN PARTICLES OF DUST
AND/OR HYDRAULIC FLUID.
U3T06191 - U1QT0M0 - UM29D5000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC RESERVOIR PRESSURIZING SYS D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 75
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29D5000000001

GENERAL ... MANUAL DEPRESSURIZATION VALVE

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC RESERVOIR PRESSURIZING SYS D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 76
SINGLE AISLE TECHNICAL TRAINING MANUAL

This Page Intentionally Left Blank


U3T06191 - U1QT0M0 - UM29D5000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC RESERVOIR PRESSURIZING SYS D/O (3) May 10, 2006
29 - HYDRAULIC POWER Page 77
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC RESERVOIR FILLING PRESENTATION (2)


the three colored lights. The direct reading gages are used if no electrical
COUPLING SOCKET power supply is available.
The coupling socket is used to fill the reservoir from a pressurized ground CHECK VALVE
hydraulic supply. The coupling socket includes a check valve.
The hydraulic fluid is sent to the reservoirs via a check valve and the
RESTRICTOR filter of the low-pressure return circuit. The check valves isolate the main
hydraulic systems from the reservoir filling system when it is not in use.
A restrictor located between the coupling socket and the reservoir filling
selector valve protects the system against over pressure.

HAND PUMP
The hand pump is used to refill the reservoirs if no ground cart is
available. The hand pump lever is on the yellow ground service panel.
A specific filling valve including a filter and a check valve is installed
on the hand pump.

FILTER
The filter of the reservoir filling system is equipped with a clogging
indicator.

NOTE: Note: No bypass possibility on this filter.


U3T06191 - U1QT0M0 - UM29P3000000001

RESERVOIR FILLING SELECTOR VALVE


The reservoir filling selector valve directs the hydraulic fluid from the
supply source to the reservoir of the selected system. Do not depressurize
the hydraulic reservoir to refill it. In the NEUTRAL position, an internal
thermal relief valve protects the selector valve from thermal expansion
of the fluid.

RESERVOIR QUANTITY INDICATOR


A reservoir quantity indicator allows refilling monitoring. It shows the
contents of the selected hydraulic reservoir that is indicated by one of
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC RESERVOIR FILLING PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 78
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29P3000000001

COUPLING SOCKET ... CHECK VALVE

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC RESERVOIR FILLING PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 79
SINGLE AISLE TECHNICAL TRAINING MANUAL

SEAL DRAIN SYSTEM PRESENTATION (2)


GENERAL
The seal drain system collects hydraulic fluid from the seal drains of
some hydraulic components. The hydraulic fluid that may escape from
some hydraulic components in the form of leak or abnormal condition,
such as hydraulic reservoir overfilling or internal overpressure, is drained
into collector tanks.

FWD SYSTEM
The FWD system consists of flexible hoses and rigid pipes connected to
a collector tank. The FWD collector tank is attached between frames 40
and 41 in the yellow hydraulic compartment. The components which are
drained into the FWD collector tank located in the yellow hydraulic
compartment are:
- blue electric pump,
- yellow electric pump,
- slats Power Control Unit (PCU),
- green hydraulic reservoir,
- yellow hydraulic reservoir.
U3T06191 - U1QT0M0 - UM29P4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) SEAL DRAIN SYSTEM PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 80
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29P4000000001

GENERAL & FWD SYSTEM

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) SEAL DRAIN SYSTEM PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 81
SINGLE AISLE TECHNICAL TRAINING MANUAL

SEAL DRAIN SYSTEM PRESENTATION (2)


AFT SYSTEM
The AFT system consists of flexible hoses and rigid pipes connected to
a collector tank. The AFT collector tank is attached to the right side of
the keel beam in the main hydraulic compartment. The components which
are drained into the aft collector located in the main landing gear
compartment are:
- flaps PCU,
- Power Transfer Unit (PTU),
- Constant Speed Motor/Generator (CSM/G),
- blue hydraulic reservoir.
U3T06191 - U1QT0M0 - UM29P4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) SEAL DRAIN SYSTEM PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 82
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29P4000000001

AFT SYSTEM

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) SEAL DRAIN SYSTEM PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 83
SINGLE AISLE TECHNICAL TRAINING MANUAL

SEAL DRAIN SYSTEM PRESENTATION (2)


TANK DRAINAGE
The system is designed so that the hydraulic fluid drains into the collector
tanks by gravity. The collector tanks attached to the aircraft structure by
means of quick release clamps must be removed for drainage. Each
collector tank, which has a capacity of 0.75 liters (0.19 US Gal), must
be emptied and cleaned at regular intervals.
U3T06191 - U1QT0M0 - UM29P4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) SEAL DRAIN SYSTEM PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 84
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29P4000000001

TANK DRAINAGE

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) SEAL DRAIN SYSTEM PRESENTATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 85
SINGLE AISLE TECHNICAL TRAINING MANUAL

RESERVOIR DEPRESSURIZATION (2)


WARNING

WARNING: PAY ATTENTION TO PROTECT YOUR HANDS AND


YOUR FACE FROM THE AIR WHICH COMES OUT
WHEN YOU OPEN RESERVOIR MANUAL
DEPRESSURIZATION VALVES. THE AIR MAY BE
HOT AND CONTAIN HYDRAULIC FLUID. USE
APPROPRIATE SAFETY WEAR.
U3T06191 - U1QT0M0 - UM29Y1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR DEPRESSURIZATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 86
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y1000000001

WARNING

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR DEPRESSURIZATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 87
SINGLE AISLE TECHNICAL TRAINING MANUAL

RESERVOIR DEPRESSURIZATION (2)


DEPRESSURIZATION OPERATION
You can depressurize each hydraulic reservoir independently. Lets take
the blue hydraulic system. Here is the blue reservoir access door. Open
the blue ground service panel. Do not forget to open, safety and tag the
C/Bs. To depressurize the hydraulic reservoir, we can use the ground
equipment or not. If not, on the ground service panel, turn the cap
assembly of the reservoir depressurization valve clockwise through 90
degrees. Pay attention to protect your hands and your face from the air,
which comes out when you open the manual depressurization valves of
the reservoirs. The air can be hot and contain hydraulic fluid. Listen if
all of the air has been released. The pressure drops down as you can see
on the air pressure gauge of the reservoir. Keep the depressurization valve
open, if it is necessary to depressurize a reservoir during a maintenance
operation. This prevents accidental pressurization of a reservoir. The
depressurization valve is closed when the maintenance operation is
completed.
U3T06191 - U1QT0M0 - UM29Y1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR DEPRESSURIZATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 88
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y1000000001

DEPRESSURIZATION OPERATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR DEPRESSURIZATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 89
SINGLE AISLE TECHNICAL TRAINING MANUAL

RESERVOIR DEPRESSURIZATION (2)


PRESSURIZATION OPERATION
To pressurize the reservoir, make sure that the depressurization valve is
closed.

NOTE: Note that the three hydraulic reservoirs are pressurized through
the air pressure manifold, thus they are pressurized at the same
time.
Open the blue hydraulic compartment door to gain access to the air
pressure manifold. Install the Ram Air Turbine (RAT) safety device to
prevent accidental deployment. Remove the cap from the ground
connector. Connect the pressurizing tool to the ground connector. Turn
the nut to open the ground connector valve. Fill the reservoir with air
until 50 psi is shown on the reservoir pressure gauge. Turn the nut to
close the ground connector valve. Remove the pressurizing tool. Install
the cap on the ground connector. Remove the RAT safety device when
the maintenance operation is completed. Close the C/Bs. Make sure that
the work area is clean and clear of tools and other items and all access
panels are closed.
U3T06191 - U1QT0M0 - UM29Y1000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR DEPRESSURIZATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 90
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y1000000001

PRESSURIZATION OPERATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR DEPRESSURIZATION (2) May 10, 2006
29 - HYDRAULIC POWER Page 91
SINGLE AISLE TECHNICAL TRAINING MANUAL

RESERVOIR FILLING (2)


But do not depressurize the system reservoir.
WARNING So, stop any supply of hydraulic power to the green or yellow systems
to the ground connectors.
WARNING: IF YOU GET THE FLUID ON YOUR SKIN OR IN YOUR The MLG doors have been opened. Put warning notices in position to
EYES: tell people not pressurization the hydraulic systems.
- FLUSH IT AWAY WITH CLEAN WATER, Electrical power being available.
- GET MEDICAL AID. On the ECAM check the green hydraulic system shows zero. If not,
MAKE SURE THAT THE TRAVEL RANGES OF THE operate the rudder to reduce the pressure to zero.
FLIGHT CONTROL SURFACES ARE CLEAR BEFORE Safety and tag the appropriate C/Bs. In the MLG bay, check that the green
YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC reservoir pressure and the green accumulator pressure are normal.
SYSTEM.
FOLLOW THE HYDRAULIC SAFETY PROCEDURES.
PRECAUTIONS HAVE TO BE TAKEN BEFORE
STARTING HYDRAULIC RESERVOIR FILLING
OPERATION. MAKE SURE THAT:
- THE SPEED BRAKES AND SPOILERS ARE
RETRACTED,
- THE THRUST REVERSERS ARE STOWED (CFM-56
ENGINE ONLY),
- THE L/G IS EXTENDED AND THE DOORS ARE
CLOSED,
- THE FWD AND AFT CARGO COMPARTMENT
DOORS ARE CLOSED.
U3T06191 - U1QT0M0 - UM29Y2000000001

PRECAUTION
Servicing passenger to fill up the green hydraulic reservoir.
Some precautions have to be taken.
Make sure that the speed brakes and spoilers are retracted, the first
reversers are staled, the L/G is extended and the door closed and the FWD
and the AFT cargo doors are closed.
All the other hydraulic services must be in normal position.
To depressurize the green hydraulic system.
Make sure the travel ranges and the fly control surfaces are clear.
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 92
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y2000000001

WARNING & PRECAUTION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 93
SINGLE AISLE TECHNICAL TRAINING MANUAL

RESERVOIR FILLING (2)


INSTALLATION
Now let's flow the green system.
Go to the ground service panel of the yellow system, to remove hand
pump handle.
On the over side, open green ground service panel.
Notice, that is possible to fill any of three hydraulic reservoirs from one
place.
It is also possible to fill the reservoir with the hydraulic service card,
connected hear.
So, the hand pump is connected to the shaft of the pump.
Above the panel you find the filling hose, removed cap.
Remove the blanking cap of the pump connect the filling hose to the
filling valve.
Put it over end in hydraulic container.
U3T06191 - U1QT0M0 - UM29Y2000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 94
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y2000000001

INSTALLATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 95
SINGLE AISLE TECHNICAL TRAINING MANUAL

RESERVOIR FILLING (2)


PROCEDURE
Turn the selector to the green system position.
Make sure that on the quantity indicator the green light comes on.
Operate the pump.
Monitor the increase of the fluid level on the quantity indicator.
If there is no electrical power available, the fluid level can be checked
on the reservoir itself.
Stop the flow when the pointer is at the end of the green line.
Turn the selector back to the NEUTRAL position.
On the quantity indicator, the green light goes out.
If a reservoir is overfilled, you cannot pressurized correctly and you must
drain it.
U3T06191 - U1QT0M0 - UM29Y2000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 96
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y2000000001

PROCEDURE

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 97
SINGLE AISLE TECHNICAL TRAINING MANUAL

RESERVOIR FILLING (2)


CLOSE-UP
Remove the filling hose and re-install the blanking caps.
Put the filling hose back in its cap position.
Remove the handle from the hand pump and put it in its cap position of
the yellow service panel.
Close the ground service panels.
C/Bs closed, L/G doors closed.
The working area is clear.
U3T06191 - U1QT0M0 - UM29Y2000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 98
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y2000000001

CLOSE-UP

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RESERVOIR FILLING (2) May 11, 2006
29 - HYDRAULIC POWER Page 99
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT STOWAGE AND SERVICING (2)


EXTENSION PROCEDURE

WARNING: PUT THE SAFETY DEVICES AND THE WARNING


NOTICES IN POSITION BEFORE YOU START A TASK
ON OR NEAR:
- THE FLIGHT CONTROLS,
- THE FLIGHT CONTROL SURFACES,
- THE L/G AND THE RELATED DOORS,
- COMPONENTS THAT MOVE.
MAKE SURE THAT THE TRAVEL RANGES OF THE
FLIGHT CONTROL SURFACES ARE CLEAR BEFORE
YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC
SYSTEM.
MAKE SURE THAT THE RAM AIR TURBINE (RAT)
TRAVEL RANGE IS CLEAR BEFORE YOU EXTEND
THE RAT.
PLACE SAFETY BARRIERS IN POSITION AND FIT
THE RAT PROTECTIVE EQUIPMENT AS PER AMM
PROCEDURE.
DO NOT STAND IN FRONT OF OR BESIDE THE RAT
PROPELLER ASSEMBLY DURING THE FUNCTIONAL
TEST.
U3T06191 - U1QT0M0 - UM29Y3000000001

NOTE: Note: do not operate the RAT deployment solenoids for more
than 60 sec. You can operate them more than once, but you
must then let them cool down for 30 min.
JOB SET-UP
Put the warning notices in the position to tell persons not to stand
directly behind or in the extension area of the RAT.
Put the safety barriers in position.
Energize the A/C electrical circuit.
Make sure that these C/Bs are closed: 106VU.
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 100
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y3000000001

EXTENSION PROCEDURE - JOB SET-UP

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 101
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT STOWAGE AND SERVICING (2)


EXTENSION PROCEDURE (continued)
PROCEDURE
On the hydraulic panel, open the protective cover and push the
MANual ON/AUTO switch in the EMERgency ELECtrical PoWeR
panel.
Make sure that the RAT extend.
Install the protective covers on the turbine blades.

NOTE: Note: make sure that a second person is on the ground near
the RAT to observe the extension of the RAT.
Note: do not operate the RAT deployment solenoids for
more than 60 seconds. You can operate them more than
once. When the operation time (solenoids energized) is max.
60 seconds, you must let solenoids cool for 30 minutes.
U3T06191 - U1QT0M0 - UM29Y3000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 102
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y3000000001

EXTENSION PROCEDURE - PROCEDURE

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 103
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT STOWAGE AND SERVICING (2)


RETRACTION PROCEDURE

WARNING: PUT THE SAFETY DEVICES AND THE WARNING


NOTICES IN POSITION BEFORE YOU START A TASK
ON OR NEAR:
- THE FLIGHT CONTROLS,
- THE FLIGHT CONTROL SURFACES,
- THE L/G AND THE RELATED DOORS,
- COMPONENTS THAT MOVE.
MAKE SURE THAT THE TRAVEL RANGES OF THE
FLIGHT CONTROL SURFACES ARE CLEAR BEFORE
YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC
SYSTEM.
MAKE SURE THAT THE GROUND SAFETY-LOCKS
ARE IN POSITION ON THE L/G.

CAUTION: make sure that the RAT is retracted completely before you
release the "RAT stow" switch. If the retraction sequence
stops just before the rat enters the bay in the fairing this will
cause damage to RAT actuator.
JOB SET-UP
U3T06191 - U1QT0M0 - UM29Y3000000001

Make sure that the warning notices are in position.


Make sure that the safety barriers are in position.
Energized the A/C electrical circuits.
Pressurize the blue hydraulic system.
Make sure that this C/B is closed: 49VU.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 104
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y3000000001

RETRACTION PROCEDURE - JOB SET-UP

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 105
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT STOWAGE AND SERVICING (2)


RETRACTION PROCEDURE (continued)
PROCEDURE
Open the door of the RAT ground control panel.
Remove the protective cover from the turbine blades.
Turn the turbine blades with your hands until the arrows on the turbine
hub and the gearbox align.
On the RAT ground control panel set the ARM switch to the on
position.
Move the STOW/RESET switch to the STOW position and hold it
there until:
- the RAT STOWED indicator light comes on,
- the ACTUATOR PRESSURE light comes on.
Make sure that the RAT retracts.
Release the STOW/RESET switch: the ACTUATOR PRESSURE
light goes off.
Set the switch 28V DC to the OFF position: the RAT STOWED light
goes off.
U3T06191 - U1QT0M0 - UM29Y3000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 106
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y3000000001

RETRACTION PROCEDURE - PROCEDURE

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 107
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT STOWAGE AND SERVICING (2)


RETRACTION PROCEDURE (continued)
CLOSE-UP
Put the A/C back to the serviceable condition:
- depressurize the blue hydraulic system,
- de-energized the A/C electrical circuits,
- if you have completed all work in the deploy area to the RAT, remove
the SAFETY DEVICE-RAT.
Close access:
- close the door of the RAT ground control panel,
- close the access doors,
- remove the warning notices,
- remove the safety barriers.
U3T06191 - U1QT0M0 - UM29Y3000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 108
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y3000000001

RETRACTION PROCEDURE - CLOSE-UP

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT STOWAGE AND SERVICING (2) May 10, 2006
29 - HYDRAULIC POWER Page 109
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT TEST (3)


A cable provides electrical connection between the RAT control panel
PRECAUTIONS and the connector on the ground checkout unit.

WARNING: PUT THE SAFETY DEVICES AND THE WARNING


NOTICES IN POSITION BEFORE YOU START A TASK
ON OR NEAR:
- THE FLIGHT CONTROLS,
- THE FLIGHT CONTROL SURFACES,
- THE L/G AND THE RELATED DOORS,
- COMPONENTS THAT MOVE.
MAKE SURE THAT THE TRAVEL RANGES OF THE
FLIGHT CONTROL SURFACES ARE CLEAR BEFORE
YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC
SYSTEM.
MAKE SURE THAT THE SAFETY LOCKS ARE IN
POSITION ON THE L/G.
MAKE SURE THAT THE RAM AIR TURBINE (RAT)
TRAVEL RANGE IS CLEAR BEFORE YOU EXTEND
THE RAT.
PLACE SAFETY BARRIERS IN POSITION AND FIT
THE RAT PROTECTIVE EQUIPMENT AS PER AMM
PROCEDURE.
DO NOT STAND IN FRONT OF OR BESIDE THE RAT
U3T06191 - U1QT0M0 - UM29Y4000000001

PROPELLER ASSEMBLY DURING THE FUNCTIONAL


TEST.

NOTE: Note: do not operate the RAT deployment solenoids for more
than 60 sec. You can operate them more than once, but you
must then let them cool down for 30 min.

GROUND CHECKOUT UNIT PRESENTATION


The ground checkout unit provides a visual indication of the RAT rpm
and the blue system pressure delivered by the RAT during a ground check.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 110
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y4000000001

PRECAUTIONS & GROUND CHECKOUT UNIT PRESENTATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 111
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT TEST (3)


RAT GROUND TEST MOTOR PRESENTATION
To test the RAT performance on ground, a ground test motor must be
connected to the RAT gearbox. The RAT ground test motor is driven by
a hydraulic ground cart.
U3T06191 - U1QT0M0 - UM29Y4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 112
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y4000000001

RAT GROUND TEST MOTOR PRESENTATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 113
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT TEST (3)


FLOW CONTROL TEST KIT PRESENTATION
To simulate A/C hydraulic consumers during RAT ground check, a flow
control test kit must be connected to the blue hydraulic service panel.
The flow control test kit provides visual indication of blue system flow
delivered by the RAT by means of a flow meter. The flow is controlled
by means of a manual adjustable flow valve.
U3T06191 - U1QT0M0 - UM29Y4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 114
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y4000000001

FLOW CONTROL TEST KIT PRESENTATION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 115
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT TEST (3)


MAIN STEPS OF THE TEST OPERATION
PREPARATION OF RAT TEST
To functionally check the RAT on ground it is necessary to:
- manually deploy the RAT from the cockpit,
- connect the ground test motor to the RAT gearbox,
- connect the ground checkout unit to the RAT control panel,
- connect the RAT flow control test kit to the blue ground service
panel.
U3T06191 - U1QT0M0 - UM29Y4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 116
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y4000000001

MAIN STEPS OF THE TEST OPERATION - PREPARATION OF RAT TEST

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 117
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT TEST (3)


MAIN STEPS OF THE TEST OPERATION (continued)
RAT EXTENTION
When the RAT is extended on the ejection spring jack, the RAT leg
drops, opening mechanically the doors.
U3T06191 - U1QT0M0 - UM29Y4000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 118
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y4000000001

MAIN STEPS OF THE TEST OPERATION - RAT EXTENTION

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 119
SINGLE AISLE TECHNICAL TRAINING MANUAL

RAT TEST (3)


MAIN STEPS OF THE TEST OPERATION (continued)
RAT TEST
Shown is the ground control unit box, which contains the control unit
and the electrical cable. The identification label is located outside the
box on the top cover. When the box is opened, in the top cover is still
electrical cable, which must be connected to the control unit and to
the RAT control panel test plug. On the ground control unit is fitted
two digital indicators. The left inside indicator is to monitor the speed
of the RAT. The RH side is to monitor the pressure delivered by RAT
pump. On the RH side lower part is located the power switch with its
red indicator light and on the LH side the electrical fuse. Here is the
hydraulic motor, which has to be installed on the gearbox after removal
of the back cover plate. The motor is fitted with the three screws. The
supplant shaft drives the hydraulic pump shaft through the turbine
pump shaft. Its hydraulic supply is a hydraulic ground cart via two
self-sealing couplings. This unit is used to create a flow in blue
hydraulic circuit, to check the flow and pressure regulation of the
RAT pump. Here is the valve to control the bypass flow.
On the opposite side is located the monitoring indicators:
- a digital flow meter indicator, a pressure indicator, a temperature
indicator and on/off switch.
U3T06191 - U1QT0M0 - UM29Y4000000001

- this tool is connected to the blue servicing panel self sealing


couplings.

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 120
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y4000000001

MAIN STEPS OF THE TEST OPERATION - RAT TEST

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) RAT TEST (3) May 10, 2006
29 - HYDRAULIC POWER Page 121
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC LEAKAGE (3)


WARNING

WARNING: PROTECT YOUR HANDS AND FACE FROM THE


HYDRAULIC FLUID WHICH COMES OUT WHEN YOU
UNSCREW HYDRAULIC LINES AND COMPONENTS.
HYDRAULIC FLUID ITSELF IS A CONTAMINANT.
USE APPROPRIATE SAFETY WEAR.
U3T06191 - U1QT0M0 - UM29Y5000000001

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC LEAKAGE (3) May 10, 2006
29 - HYDRAULIC POWER Page 122
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y5000000001

WARNING

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC LEAKAGE (3) May 10, 2006
29 - HYDRAULIC POWER Page 123
SINGLE AISLE TECHNICAL TRAINING MANUAL

HYDRAULIC LEAKAGE (3)


long before it happens. If clamps or line blocks are removed so a tube or
PREVENTING HYDRAULIC LEAKS component can be replaced, be sure that they are reinstalled again. Tubes
that are not properly supported will vibrate. Vibration is the greatest
These simple plumbing problems can also be real hard to fix if you don't
enemy of a hydraulic system. It causes tubes to crack, and connections
know the basic hydraulic plumbing rules. If you don't work carefully and
at fittings to loosen up and leak. When repairs are finished, always bleed
follow these rules, your work may be the cause of the next hydraulic leak
the system, and leak check your work. We, the mechanics, have control
that delays or cancels a flight. Let's look at these basic hydraulic plumbing
of torquing. The lack of proper torquing is the single greatest cause of
rules: contamination that gets into a system or collects on sealing surfaces
leaks. Those calibrated elbows are notorious for being out of calibration.
can cause leaks internal and external. Hydraulic fluid itself is a
Use a torque wrench.
contaminant. It can eat paint and decals. When hydraulic fluid is allowed
to penetrate a composite structure, it will attack the core material and
reduce it to mush. Once a composite assembly has been attacked, its
structural integrity will be lost. To avoid damage caused by twisting,
tearing, and chipping, always lubricate O-rings, packing seals, back-up
rings, and fitting threads with hydraulic fluid before assembly. When
assembling hydraulic system fittings, be sure that seals and back-up rings
are properly positioned before torquing the connection. When installing
an elbow fitting into a component, be sure that all the threads are
completely screwed into the boss. This is to make sure that the O-ring
packing rides in the undercut, and not on the threads. To prevent an elbow
fitting from turning while its lock-nut is being torqued, hold it with a
second wrench.
To make a stress-free installation, be sure that all elbow-to-pipe
U3T06191 - U1QT0M0 - UM29Y5000000001

connections are correctly aligned before torquing the B-nuts. Do not use
pointed, sharp-edged, or steel tools to remove or install O-ring packing,
back-up rings, and seals. Damage may occur. Never reinstall used O-ring
packing or seals. Once they have been compressed, they will never regain
their original shape again. Before torquing a B-nut, be sure that the tube
fits squarely into the fitting. Never force or bend a tube to make it fit.
Metal tubes don't stretch. If the piece seems shorter upon reinstallation
or after a component change, something is wrong. Stop! Think! And
investigate the problem before you proceed. Make sure that tubes are not
forced into clamps or line blocks. A stressed installation will lead to a
cracked tube at the nearest fitting or B-nut. And, you can bet it won't be
MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC LEAKAGE (3) May 10, 2006
29 - HYDRAULIC POWER Page 124
SINGLE AISLE TECHNICAL TRAINING MANUAL
U3T06191 - U1QT0M0 - UM29Y5000000001

PREVENTING HYDRAULIC LEAKS

MAINTENANCE COURSE - T1 & T2 (CFM56-5B/ME) HYDRAULIC LEAKAGE (3) May 10, 2006
29 - HYDRAULIC POWER Page 125
AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE
STM
REFERENCE U3T06191
MAY 2006
PRINTED IN FRANCE
AIRBUS S.A.S. 2006
ALL RIGHTS RESERVED

AN EADS JOINT COMPANY


WITH BAE SYSTEMS