MEIKO ECOSTAR & UPSTER Troubleshooting

Info & ERR.


Description Possible cause Action
- No.
INFORMATION MESSAGES

Emergency programme • No boiler/tank heating • Continued work possible at limited capacity


120
active • No fresh water supply • Call a service technician!

• Door/hood open
• I/O circuit board is de-fective • Close door/hood
121 Door/hood not closed
• Microswitch defective • Call a service technician!
• Microswitch not cor-rectly set

Incorrect password/no
122 • Code incorrectly en-tered • Enter code again
authorization

• No intervention by the operator is necessary


123 Factory setting parame-ter list • Switch supply voltage on/off
• Message disappears after 5 min.

• The set operating hours (P 122) or batch num-ber (P 123) has • Continued work possible
126 Maintenance required
been reached • Call a service technician!

Lack of rinse aid (with


420 integrated fill-level de-
• Replace empty storage tank
tection) • Storage tank empty
• Check suction lance
Lack of detergent (with • Suction lance not cor-rectly introduced
• Possibly Bleed pipes
520 integrated fill-level de-
tection)

• Let regeneration programme run to completion


720 Regeneration is run-ning • Regeneration pro-gramme has been started and is running • Regeneration programme cannot be interrupted
• Continued work possible

721 Regeneration not pos-sible • Salt container empty Fill salt container

• No salt present Fill salt container


722 Salt container empty
• No water in the salt container • Possibly Fill water in the salt container

ERROR MESSAGES
• EEPROM
– Not present/defective • Not possible to continue working
001 EEPROM plug-in fault.
– Installed incorrectly • Call a service technician!
– Incorrect data/empty
• Not possible to continue working
111 Floor pan leakage • There is a leak
• Call a service technician!

Signal of the two door • Malfunction/defect door contact • Not possible to continue working
118
contact switches unequal switch • Call a service technician!

Boiler level not reached


during first filling (with
201
integrated pressure booster • Fresh water inlet insufficient (water tap closed)
• Check water supply
pump) • Feed hose kinked/disconnected/leaks
• Check feed hose
• Inlet filter soiled
• Check pre-filter/sieve and clean, if necessary
Boiler level not reached on • Solenoid valve defective
• Where appropriate, call a service technician!
time during filling (with • Boiler switch defective
202
integrated pressure booster
pump)

No change detected by the


boiler level switch when
203 • Pressure booster pump defective
emptying (with integrated
pressure booster pump) • Plug connections disconnected (e.g. pressure booster pump)
• Start capacitor defective
• Not possible to continue working
• Boiler level switch defective
• Call a service technician!
No change yet detected at • No signal to or from pressure booster pump and I/O circuit
the boiler level switch (with board
204 integrated pressure booster • No signal boiler full - from I/O circuit board
pump installed) after the
rinse time expired

• Boiler heating defective/melting beads, heating element


Boiler temperature not
• Temperature sensor defective, incorrect installation position • Not possible to continue working
205 reached after max. heat time
• Boiler protection defective, output switch triggered • Call a service technician!
(P310)
• No signal from I/O circuit board

• Boiler not ready for final rinse on time (temperature or level not
reached) • Acknowledge message, continued work possible
• Boiler heating defective (melting beads) • Let programme run without intervention by the
206 Wash time increase
• Temperature sensor defective operator
• Boiler protection defective, output switch triggered • If it occurs frequently, call a service technician!
• No signal from I/O circuit board

Page 1 of 2
MEIKO ECOSTAR & UPSTER Troubleshooting

Info & ERR.


Description Possible cause Action
- No.
INFORMATION MESSAGES
Boiler temperature sensor
210
shortcircuit • Sensor defective
• Not possible to continue working
• Sensor position not correct
Boiler temperature sensor • Call a service technician!
211 • Plug contact not connected properly
interruption

“Actual” boiler temperature • Contactor sticking • Not possible to continue working


212
too high (>95°C) • Incorrect sensor/defective sensor • Call a service technician!

• Feeding water pressure too low


• Check water supply
Number of circulatory • Inlet filter soiled
• Clean rinse nozzles
pumping cycles for tank • Rinse nozzles dirty •
301 • Call a service technician!
filling exceeded Air trap dirty
• Check feed hose
Tank level analysis disrupted • Condensate in level pipe
• Clean inlet filter
• Feed hose kinked/disconnected/leaks

While drain pumping during


the wash programme, tank
302 level 1 is not fallen below on
• Drain pump output too low
time (with integrated
• Drain pump dirty/defective
drain pump) • Impeller loose
• Drain pump plug connection open • Not possible to continue working
• Start capacitor defective • Call a service technician!
While drain pumping during • Tank level analysis disrupted
the wash programme, tank • Aquastop does not close correctly
303 level 3 is not fallen below on • No signal from I/O circuit board
time (with integrated drain
pump)

• Tank heating defective/melting


beads, heating element
Tank temperature not
• Temperature sensor defective, incorrect • Not possible to continue working
304 reached after max. heat time
installation position • Call a service technician!
(P314)
• Tank protection defective, output
switch triggered

• Feeding water pressure too low


• Inlet filter soiled
• Check water supply
• Rinse nozzles dirty
Number of boiler fills • Check feed hose
• Air trap dirty
305 insufficient for rinsing. Tank • Clean inlet filter
• Condensate in level pipe
level 2 not reached • Clean rinse nozzles
• Feed hose kinked/disconnected/leaks
• Call a service technician!
• Level sensor defective
• Plug contact not connected properly

• Air trap dirty


Max. tank level exceeded
• Condensate in level pipe • Empty dishwashing machine and refill
306 Tank level analysis
• Level sensor defective • Call a service technician!
disrupted.
• Plug contact not connected properly

• Air trap dirty


• Condensate in level pipe • Empty dishwashing machine and refill
307 Tank level sensor defective
• Level sensor defective • Call a service technician!
• Plug contact not connected properly

Temperature sensor short- • Connection plug loosened


310 • Call a service technician!
circuit • Sensor or I/O circuit board defective

• Sensor defective
Temperature sensor • Not possible to continue working
311 • Sensor position not correct
interruption • Call a service technician!
• Plug contact not connected properly

Actual tank temperature too • Contactor sticking • Not possible to continue working
312
high (>85°C) • Incorrect sensor/defective sensor • Call a service technician!

Page 2 of 2