Asco 8316G064V

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

PRODUCT IDENTIFICATION

Catalogue number identification system


Products in this catalogue are identified by an alphanumerical or numerical identification system
ALPHANUMERICAL CATALOGUE NUMBERS
E 290A385 The catalogue number appears on the product label:
SC B 262C220
SC X(1) S 272A017
WP E 030B013 E MBMO
TPL 20655 A
prefix
pipe thread
series no.
basic number
suffix
TPL no.

(1) The prefix X is always associated with the TPL (temporary parts list) number
PREFIX - Electrical characteristics, connectors etc.
prefix SUFFIX - Seal materials, manual operator etc.
description (under the “options” column in the SPECIFICATIONS table)
1 2 3 4 5 6 7
C F S C Solenoid with connector DIN 43650, 9,4 mm, pilot 302 suffix
description
C F V T Solenoid with connector M12, LED and protection, pilot 302 1 2 3 4 5 6 7
E F Explosionproof - NEMA 3, 4, 6, 7, 9 C O Epoxy coating on all external surfaces
E V Explosionproof - NEMA 3, 4, 6, 7, 9 - 316 SS E EPDM (ethylene-propylene)
W B L P Increased safety / encapsulation - moulded enclosure ATEX-IECEx N Oxygen service (CR (chloroprene)
E M Encapsulated ATEX-IECEx N V FPM (fluoroelastomer) parts cleaned for oxygen service
E T Threaded conduit / ext. thread (M20 x 1.5) H W Diaphragm for hot water service
H T Class H - high temperature , +80°C ambient temp. J CR (chloroprene / neoprene)
L T Low temperature
L P K F Flameproof - Alum. ATEX-IECEx
M B Mounting bracket
N F Flameproof - Alum. ATEX-IECEx
M O Impulse or maintained manual operator
P V Encapsulated ATEX-IECEx M S Maintained manual operator
S C Solenoid with spade plug connector P Dry gas, non-lubricated air construction
T Threaded conduit / ext. thread (1/2" NPT) Q Long life construction
W P Waterproof IP67 - metal enclosure S L Certifiied IEC 61508 Functional Safety data
L I Intrinsically safe - Alum. enclosure ATEX-IECEx T PTFE (polytetrafluoroethylene)
N F I S I.S. with Aluminium IP67 enclosure ATEX-IECEx V FPM (fluoroelastomer)
W S Waterproof IP67 - 316 SS enclosure V M Primary vacuum
W S E M Encapsulated ATEX-IECEx, 316 SS enclosure V H Secondary vacuum
W S L I Intrinsically safe - 316L enclosure ATEX-IECEx
TPL (temporary parts list) number - always associated with the prefix X
W S L P K F Flameproof - 316L SS ATEX-IECEx
(under “options” in the catalogue)
W S N F Flameproof - 316L SS ATEX-IECEx
TPL description
W S N F I S I.S. with 316 SS IP67 enclosure ATEX-IECEx
S G Dust applications - coils and connectors - II 3 D, Ex tc IIIC 20547 Version for external pilot air supply (series 551-553)
X Other special constructions * 20655 Manual operator with pushbutton (series 272-374)
20674 LED and protection (prefix CFSC)
* If prefix X is used, always specify Temporary Parts List (TPL) number
23012 2 Mounting holes øM4, 7 mm depth (stainless steel body, series 370)

NUMERICAL CATALOGUE NUMBERS


165 0 0088 210555
The catalogue number appears on the product label:
Availability, design and specifications are subject to change without notice. All rights reserved.

109 0 0040 970517

series no.
type of standard material
10900040
serial number
option code

OPTION CODES (under “options” in the catalogue)


option description
210555 Protective cover mounted on valves 1/2-3/4-DN15-20 (series 165-166)
210556 Protective cover mounted on valves 1-1 1/4-DN25-32 (series 165-166)
210557 Protective cover mounted on valves 1 1/2-2-DN40-50 (series 165-166)
210558 Protective cover mounted on valves DN65-80 (series 165)
260657 2 explosionproof switches, 1 contact, -20°..+80°C, DN15..32 (series 165-166)
260658 2 explosionproof switches, 1 contact, -20°..+80°C, DN40..80 (series 165-166)
260660 2 explosionproof switches, 2 contacts, -20°..+80°C, DN15..32 (series 165-166)
260661 2 explosionproof switches, 2 contacts, -20°..+80°C, DN40..80 (series 165-166)
260663 2 explosionproof switches, 1 contact, -55°..+82°C, DN15..32 (series 165-166)
00003GB-2016/R01

260664 2 explosionproof switches, 1 contact, -55°..+82°C, DN40..80 (series 165-166)


970509 Oxygen service (series 165 except for DN65 to 80, series 166)
970517 Oxygen service (series 108-109)
970523 Valve body degreased during assembly (series 165-166)

All leaflets are available on: www.asco.com


V003-1
3/2
4
Pilot Operated
Air and Water Solenoid Valves SERIES
Brass Body • 3/8" to 1" NPT 8316

Features

3-WAY
• Diaphragm poppet valves suitable for controlling % )
air, inert gas, and liquids
• Internal piloting controls large orifices to provide
high flows
• Can be used to pilot large actuators to provide quick
closing of large control valves
• Resilient seating for tight shutoff
• Mountable in any position

Construction
Valve Parts in Contact with Fluids
Body Brass
Seals and Disc NBR
Diaphragm Assembly NBR
A
Core Tube 305 Stainless Steel NC
E P
Core and Plugnut 430F Stainless Steel
Core Springs 302 Stainless Steel and 17-7PH Stainless Steel NO

Shading Coil Copper


Pilot Seat Cartridge
CA
and Disc-Holder

Electrical
Watt Rating and Power
Standard Consumption Spare Coil Part Number
Coil and
General Purpose Explosionproof
Class of DC AC VA VA
Insulation Watts Watts Holding Inrush AC DC AC DC
F 10.6 6.1 16 30 238210 238310 238214 238314
F 22.6 17.1 40 70 238610 238710 238614 238714
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).
6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages
available when required.
Approvals
CSA certified. Meets applicable CE directives.
Solenoid Enclosures Refer to Engineering Section for details.
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X. ATEX/IECEx certified with prefix “EV” as listed.
Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9. Refer to Optional Features Electrical Section for details.
(To order, add prefix “EF” to catalog number.)
See Optional Features Section for other available options. Important
A minimum operating pressure differential must be
Nominal Ambient Temp. Ranges maintained between the pressure and exhaust ports.
AC: 32˚F to 125˚F (0˚C to 52˚C) Supply and exhaust piping must be full area, unrestricted.
DC: 32˚F to 104˚F (0˚C to 40˚C) ASCO flow controls and other similar components
Refer to Engineering Section for details. must be installed in the cylinder lines only.

55
3/2
SERIES
8316 4
Specifications (English units)
3-WAY

Operating Pressure Watt Rating/


Differential (psi) Max. Fluid Brass Body Class of Coil
Max. AC Max. DC Temp. ˚F Insulation ≠
Pipe Orifice Cv
Size Size Flow Air-Inert Water Air-Inert Water Const.
(in) (in) Factor Min. ¨ Gas ¬ Gas ¬ AC DC Catalog Number Ref. AC DC
NORMALLY CLOSED (Closed when de-energized)
3/8 5/8 2.5 10 150 125 125 125 180 120 8316G054 1 6.1/F 10.6/F
3/8 5/8 2.5 10 250 250 250 250 180 120 8316G014 √ 2 17.1/F 22.6/F
1/2 5/8 3.2 10 150 125 125 125 180 120 8316G064 1 6.1/F 10.6/F
1/2 5/8 3.2 10 250 250 250 250 180 120 8316G024 2 17.1/F 22.6/F
3/4 11/16 4.8 10 150 125 125 125 180 120 8316G074 3 6.1/F 10.6/F
3/4 11/16 4.8 10 250 250 250 250 180 120 8316G044 4 17.1/F 22.6/F
1 1 12.5 10 150 125 125 125 180 120 8316G034 5 6.1/F 10.6/F
NORMALLY OPEN (Open when de-energized)
3/8 5/8 2.5 10 150 125 125 125 180 120 8316G056 1 6.1/F 10.6/F
3/8 5/8 2.5 10 250 250 250 250 180 120 8316G016 2 17.1/F 22.6/F
1/2 5/8 3.2 10 150 125 125 125 180 120 8316G066 1 6.1/F 10.6/F
1/2 5/8 3.2 10 250 250 250 250 180 120 8316G026 2 17.1/F 22.6/F
3/4 11/16 4.8 10 150 125 125 125 180 120 8316G076 3 6.1/F 10.6/F
3/4 11/16 4.8 10 250 250 250 250 180 120 8316G046 4 17.1/F 22.6/F
1 1 12.5 10 150 125 125 125 180 120 8316G036 5 6.1/F 10.6/F
¨ 10 psi Minimum Operating Pressure Differential required. Valve vents to "zero" psi. ≠ On 50 hertz service, the watt rating for 6.1/F solenoid is 8.1 watts.
¬ Water rating, CSA certified up to 232 psi. √ ATEX/IECEx certified with prefix “EV”.

Specifications (Metric units)


Operating Pressure Watt Rating/
Differential (bar) Max. Fluid Brass Body Class of Coil
Max. AC Max. DC Temp. ˚C Insulation ≠
Pipe Orifice Kv Flow
Size Size Factor Air-Inert Water Air-Inert Water Const.
(in) (mm) (m3/h) Min. ¨ Gas ¬ Gas ¬ AC DC Catalog Number Ref. AC DC
NORMALLY CLOSED (Closed when de-energized)
3/8 16 2.1 0.7 10 9 9 9 82 49 8316G054 1 6.1/F 10.6/F
3/8 16 2.1 0.7 17 17 17 17 82 49 8316G014 √ 2 17.1/F 22.6/F
1/2 16 2.7 0.7 10 9 9 9 82 49 8316G064 1 6.1/F 10.6/F
1/2 16 2.7 0.7 17 17 17 17 82 49 8316G024 2 17.1/F 22.6/F
3/4 17 4.1 0.7 10 9 9 9 82 49 8316G074 3 6.1/F 10.6/F
3/4 17 4.1 0.7 17 17 17 17 82 49 8316G044 4 17.1/F 22.6/F
1 25 11 0.7 10 9 9 9 82 49 8316G034 5 6.1/F 10.6/F
NORMALLY OPEN (Open when de-energized)
3/8 16 2.1 0.7 10 9 9 9 82 49 8316G056 1 6.1/F 10.6/F
3/8 16 2.1 0.7 17 17 17 17 82 49 8316G016 2 17.1/F 22.6/F
1/2 16 2.7 0.7 10 9 9 9 82 49 8316G066 1 6.1/F 10.6/F
1/2 16 2.7 0.7 17 17 17 17 82 49 8316G026 2 17.1/F 22.6/F
3/4 17 4.1 0.7 10 9 9 9 82 49 8316G076 3 6.1/F 10.6/F
3/4 17 4.1 0.7 17 17 17 17 82 49 8316G046 4 17.1/F 22.6/F
1 25 11 0.7 10 9 9 9 82 49 8316G036 5 6.1/F 10.6/F
¨ 1 bar Minimum Operating Pressure Differential required. Valve vents to "zero" bar. ≠ On 50 hertz service, the watt rating for 6.1/F solenoid is 8.1 watts.
¬ Water rating, CSA certified up to 16 bar. √ ATEX/IECEx certified with prefix “EV”.

56
3/2
4 SERIES
8316

Dimensions: inches (mm)

3-WAY
Const.
Ref. H K L P
in 5.08 3.08 2.76 3.94
1
mm 129 78 70 100 Const. Ref. 1, 2
in 5.26 3.15 2.76 4.12
2
mm 134 80 70 105

57
3/2
SERIES
8316 4
Dimensions: inches (mm)
3-WAY

Const.
Ref. A B C H K L M N P R W
in 1.61 1.41 1.66 6.01 3.46 3.38 2.16 .53 4.32 .50 3.31
3
mm 41 36 42 153 88 86 55 13 110 13 84
in 1.61 1.41 1.66 6.19 3.53 3.38 2.16 .53 4.50 .50 3.31
4
mm 41 36 42 157 90 86 55 13 114 13 84
in - 1.80 - 6.63 3.71 4.44 2.81 .88 4.57 1.74 5.32
5
mm - 46 - 168 94 113 71 22 116 44 135

Const. Ref. 3, 4, 5

FLOW DIAGRAMS

Normally Closed Normally Open


De-Energized Energized De-Energized Energized

58

You might also like