Therma V Split Dec 2012
Therma V Split Dec 2012
(50Hz/R410A)
5BPU0-03C(Replace:5BPU0-03B)
CONTENTS
1. Features
2. Nomenclature
3. Specification
4. Drawing
5. Wiring Diagram
6. Piping Diagram
7. Operation Range
8. Pump Hydraulic Performance
1. Features
• Providing eco-friendly heating
• High energy efficiency
• Easy installation
• Space heating, cooling, and sanitary water heating
Indoor Unit
H N 09 1 4
Heater Capacity (kW)
Ex) 04 : 4kW Class 06 : 6kW Class 09 : 9kW Class
Electrical Ratings
1 : 1 Phase 220-240V 50Hz
2 : 3 Phase 220V 50Hz
3 : 3 Phase 380-415V 50Hz
Classification
09 (Combined with 09kW of Outdoor Unit)
16 (Combined with 12/14/16kW of Outdoor Unit)
N : Hydro kit (Indoor Unit)
Indoor Unit
Material - Stainless Steel Stainless Steel Stainless Steel
Water Circuit Safety Valve bar 3 3 3
Entering Side Diameter inch Male PT 1 Male PT 1 Male PT 1
Leaving Side Diameter inch Male PT 1 Male PT 1 Male PT 1
Manometer - O O O
Drain Valve / Fill Valve - O O O
Shut Off Valve - O O O
Air Vent - O O O
Refrigerant Circuit Gas Side Diameter mm(inch) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Liquid Side Diameter mm(inch) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
Dimensions Unit(H x W x D) mm 850 x 490 x 315 850 x 490 x 315 850 x 490 x 315
Packed Unit(H x W x D) mm 1080 x 563 x 375 1080 x 563 x 375 1080 x 563 x 375
Weight Unit kg 54.5 54.5 54.5
(Without water) Packed Unit kg 61.5 61.5 61.5
Sanitary Water Tank Type - Indirect heating(+ Electric heater)
Heater Capacity kW Max. 3
Power Supply Ø / V / Hz 1 / 230 / 50
Power Supply Type - Separated power source
Thermal Protector Range °C Max. 90
Magnet switch - Needed
MCCB A 40
Sensor Adaptor Diameter mm(inch) 12.7 (1/2)
Accessory Kit - LG Supply (model : PHLTA) LG Supply (model : PHLTC) LG Supply (model : PHLTC)
Note :
1. The specification may be subject to change without prior notice for purpose of improvement.
No Name Remarks
1 Refrigerant Pipe Ø15.88mm
2 Refrigerant Pipe Ø9.52mm
3 Entering Water Pipe Male PT 1 inch
4 Leaving Water Pipe Male PT 1 inch
5 Control Panel Built-in Remote Controller
6 Water Pump Max Head 7.5 / 6.5 meter
7 Safety Valve Open at water pressure 3 bar
8 Thermal switch Cut-off power input to electric heater at 90 centigrade (manual return at 55 centigrade)
Cut-off power input to electric heater at 90(primary) and 200(secondary) centigrade (auto
8' Thermal switch
return at 70 centigrade for first thermal switch)
848
9 Control Box PCB and terminal blocks
10 Flow Switch Minimum operation range at 12 LPM
11 Plate Heat Exchanger Heat exchange between refrigerant and water
12 Pressure Gage Indicates circulating water pressure
13 Expansion Tank Absorbing Volume change of heated water
14 Air Vent Air purging when Charging water
15 Electric Heater Additional heating source
16 Strainer Filtering and stacking particles inside circulating water
17 Shut-off valve When connecting water pipes,drain water or block the flow from indoor unit
18 Carrying handle To carry the product
Notice : Item 8 and Item 8’ will be applied exclusively
Note
1. Unit should be installed in compliance with the installation manual in
the product box.
2. Unit should be grounded in accordance with the local regulations or
applicable national codes.
3. All electrical components and materials to be supplied on the site
must comply with the local regulations or international codes.
4. Electrical characteristics chapter should be considered for electrical
work and design. Especially the capacity of power cable and circuit
breaker for outdoor unit should be more than that of electrical
characteristics chapter.
[Unit:mm]
Hydro kit
AWHP
AHNW09***A1 (HN09** NK1)
AHNW16***A1 (HN16** NK1)
4.2 External
4. Drawing
No Name Remarks
1 Door Control panel is shown after this door is opened.
Note
1. Unit should be installed in compliance with the installation manual in
the product box.
2. Unit should be grounded in accordance with the local regulations or
applicable national codes.
3. All electrical components and materials to be supplied on the site
must comply with the local regulations or international codes.
4. Electrical characteristics chapter should be considered for electrical
work and design. Especially the capacity of power cable and circuit
breaker for outdoor unit should be more than that of electrical
characteristics chapter.
[Unit:mm]
Hydro kit
AWHP
AHNW09***A1 (HN09** NK1)
Mounting to Wall AHNW16***A1 (HN16** NK1)
Step 1. After releasing eight screws, detach front cover from the indoor unit. While detaching the Step 3. Detach the Installation sheet. Screw bolts with supporting plate at the hole
4. Drawing
front cover, grab the carrying handles at left and right sides of the front cover. Then pull marks on the wall. When screwing bolts, use M8 ~ M11 anchor bolts to
into upward direction. When assemble the front cover, remove detached side brackets of secure hanging the indoor unit.
the front cover and ONLY tighten two screws of bottom.
4.3 For Installation
(Ha
ll m
ark
s)
Bottom
screws
Remove
Step 2. Attach "Installation Sheet" to the wall and mark the location of bolts. This sheet helps to Step 4. Hang the indoor unit at the supporting plate. Also, catch the carrying han-
find correct location to the bolts. dles at left and right sides of the indoor unit.
Hydro kit
AWHP
AHNW09***A1 (HN09** NK1)
AHNW16***A1 (HN16** NK1)
4. Drawing
248
200
384
500
1300
350
[Unit:mm]
Hydro kit
5. Wiring Diagram
AHNW**6**A1 (HN**1* NK1)
Indoor Unit
Indoor Unit
MCCB
M/C
220V
50Hz
3~
MCCB
3
M/C
M/C
230V
50Hz
1~
Solar
6. Piping Diagram
Thermal
Componets
Fan
Coil
Unit
Underfloor
Heating
Radiator
Sanitary water tan Solar thermal syst
k is installed em is connected
(Sanitary water tan (Solar thermal kit i
Basic installation k kit is necessary) s necessary)
(IDU + ODU)
- Model : PQRSTA0
CTR/PNL Control Panel (or ‘Remote Controller’) CN_REMO - Pre built-in at indoor unit
- 3rd party accessory and Field installation
(sold separately)
2WAY V/V_1 To control water flow for Fan Coil Unit CN_2WAY(A) - 2wire NO or NC type 2way valve is
supported.
- 3rd party accessory and Field installation
W/TANK (sold separately)
Sanitary Water Tank (no connector)
- Generating and storing sanitary hot water by
AWHP or built-in electric heater-
- 3rd party accessory and Field installation
B/HT Electric Heater CN_B/HEAT(A) (usually built-in at W/TANK)
- Supplying additional water heating capacity.
Water
- Flow control for water which is leaving from
Heating - 3rd party accessory and Field installation
indoor unit. CN_3WAY(A)
3WAY V/V_1 (sold separately)
- Flow direction switching between under-
floor and water tank - SPDT type 3way valve is supported.
Water to be heated by Indoor unit and B/HT (no connector)
CITY WATER - Field installation
of W/TANK
SHOWER Water supplied to end-user (no connector) - Field installation
- TH6 and TH7 are connected at 4 pin type
TH6 W/TANK water temperature sensor connector CN_TH4.
- TH6 is a part of sanitary water tank kit.
CN_TH4 (model: PHLTA)
TH7 Solar-heated water temperature sensor - TH7 is a part of solar thermal kit
(model: PHLLA)
- Flow control for water which is heated and
- 3rd party accessory and Field installation
3WAY V/V_2 circulated by SOLAR THERMAL SYSTEM. CN_3WAY(B) (sold separately)
- Flow direction switching between SOLAR
THERMAL SYSTEM and W/TANK - SPDT type 3way valve is supported.
48 48
43 43
)
)
Outdoor Temperature(
Outdoor Temperature(
Indoor Unit
10 10
5 5
6 16 25 30 16 25 30
Leaving Water Temperature( ) Leaving Water Temperature( )
Continuous Operation
Operative
30 30
)
)
24 24
Outdoor Temperature(
Outdoor Temperature(
Indoor Unit
-15 -15
-20 -20
15 20 50 55 15 20 50 55
Leaving Water Temperature( ) Leaving Water Temperature( )
Continuous Operation
Operative
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
Med.
1.5
Indoor Unit
Max.
1.0
12.0
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100 110
Water Flowrate(l/min)
5.0
4.5
Max.
4.0
3.5
Med.
3.0
2.5
2.0
1.5
15.0
1.0
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100 110
Water Flowrate(l/min)
Warning : Selecting a water flowrate outside the curves can cause damage to or malfunction of the unit.
: Operation cutoff range
1. Features
2. Nomenclature
3. Specification
4. Drawing
5. Wiring Diagram
6. Piping Diagram
7. Performance Data
8. Noise Criteria
1. Features
• Providing eco-friendly heating
• High energy efficiency
• Easy installation
• Space heating, cooling, and sanitary water heating
Outdoor Unit
U : Outdoor Unit
Outdoor Unit
Connection Outer Diameter mm(inch) 15.88(5/8) 15.88(5/8)
Piping Length Minimum m 3 3
(Outdoor Unit ~ Standard m 7.5 7.5
Indoor Unit) Maximum m 50 50
Height Difference
Maximum m 30 30
(Outdoor Unit ~ Indoor Unit)
Additional Refrigerant Charge g/m 30 60
Dimensions Unit(W x H x D) mm 950 x 834 x 330 950 Χ 1,380 Χ 330
Packed Unit(W x H x D) mm 1,140 x 900 x 461 1,140 Χ 1,462 Χ 461
Weight Unit kg 64 105
Packed Unit kg 69 116
Note :
1. Capacities and power inputs are based on the following conditions:
* : Cooling conditions - Indoor Water Temperature 23°C/18°C; Outdoor Air Temperature 35°CDB/24°CWB
Heating conditions - Indoor Water Temperature 30°C/35°C; Outdoor Air Temperature 7°CDB/6°CWB
Standard piping length 7.5m
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Note :
1. Capacities and power inputs are based on the following conditions:
* : Cooling conditions - Indoor Water Temperature 23°C/18°C; Outdoor Air Temperature 35°CDB/24°CWB
Heating conditions - Indoor Water Temperature 30°C/35°C; Outdoor Air Temperature 7°CDB/6°CWB
Standard piping length 7.5m
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Outdoor Unit
Connection Outer Diameter mm(inch) 15.88(5/8) 15.88(5/8)
Piping Length Minimum m 3 3
(Outdoor Unit ~ Standard m 7.5 7.5
Indoor Unit) Maximum m 50 50
Height Difference
Maximum m 30 30
(Outdoor Unit ~ Indoor Unit)
Additional Refrigerant Charge g/m 50 50
Dimensions Unit(W x H x D) mm 950 x 1,380 x 330 950 x 1,380 x 330
Packed Unit(W x H x D) mm 1,140 x 1,462 x 461 1,140 x 1,462 x 461
Weight Unit kg 105 105
Packed Unit kg 116 116
Note :
1. Capacities and power inputs are based on the following conditions:
* : Cooling conditions - Indoor Water Temperature 23°C/18°C; Outdoor Air Temperature 35°CDB/24°CWB
Heating conditions - Indoor Water Temperature 30°C/35°C; Outdoor Air Temperature 7°CDB/6°CWB
Standard piping length 7.5m
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Note
1. Unit should be installed in compliance with the installation manual in
the product box.
2. Unit should be grounded in accordance with the local regulations or
applicable national codes.
3. All electrical components and materials to be supplied on the site
must comply with the local regulations or international codes.
4. Electrical characteristics chapter should be considered for electrical
work and design. Especially the capacity of power cable and circuit
breaker for outdoor unit should be more than that of electrical
characteristics chapter.
[Unit:mm]
U4
AHUW126A1 (HU121 U31)
AHUW146A1 (HU141 U31)
AHUW166A1 (HU161 U31)
4. Drawing
Note
1. Unit should be installed in compliance with the installation manual in
the product box.
2. Unit should be grounded in accordance with the local regulations or
applicable national codes.
3. All electrical components and materials to be supplied on the site
must comply with the local regulations or international codes.
4. Electrical characteristics chapter should be considered for electrical
work and design. Especially the capacity of power cable and circuit
breaker for outdoor unit should be more than that of electrical
characteristics chapter.
[Unit:mm]
Outdoor Unit
EEV
LIQUID SIDE
3-Way
Service Valve Th6
Th2
Th7
Th8
Indoor Unit Outdoor Unit
Plate Heat Heat Exchanger
Exchanger
Low Pressure
Switch
Th3
Description
PCB Connector
Outdoor Unit
Category Symbol Meaning AHUW126A1 AHUW128A1 Remarks
AHUW096A1 AHUW146A1 AHUW148A1
AHUW166A1 AHUW168A1
- Optional accessory (being sold sepa-
Th1 Remote air temperature sensor CN_ROOM CN_ROOM CN_ROOM rately)
- Not shown in diagram
Indoor Unit
Th2 Inlet evaporator temperature sensor CN_PIPE/IN CN_PIPE/IN CN_PIPE/IN - Meaning is expressed based on Cool-
Th3 Outlet evaporator temperature sensor CN_PIPE/OUT CN_PIPE/OUT CN_PIPE/OUT ing mode.
Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20°C 6.58 1.54 7.39 1.57 8.21 1.60 8.55 1.61 9.05 1.63 9.29 1.64
30°C 6.47 2.17 7.10 2.20 7.73 2.23 8.15 2.25 8.78 2.28 9.20 2.30
AHUW096A1 35°C 6.21 2.41 6.91 2.44 7.51 2.47 8.04 2.52 9.00 2.65 9.02 2.71 9.33 2.74
(HU091 U41) 40°C 5.79 2.86 6.38 2.89 6.97 2.93 7.37 2.96 7.96 3.00 8.32 3.03 8.68 3.06
45°C 5.15 3.03 5.75 3.09 6.35 3.15 6.75 3.20 7.35 3.26 7.27 3.06 7.18 2.87
Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20°C 9.54 2.00 11.04 2.34 12.55 2.68 14.06 3.03 15.56 3.37 17.07 3.72
30°C 12.82 4.19 13.15 4.25 14.07 4.40 15.45 4.44 15.38 4.21 16.02 3.98
AHUW126A1 35°C 11.65 4.48 12.53 4.65 13.40 4.75 14.44 4.77 14.50 4.00 14.97 4.28 15.57 4.53
(HU121 U31) 40°C 11.17 4.89 11.61 5.02 12.68 5.18 13.43 5.25 13.31 4.39 13.77 4.49 14.29 4.59
45°C 9.37 5.24 10.39 5.37 11.41 5.51 12.43 5.64 13.46 5.77 14.16 5.83 14.87 5.89
Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20°C 10.63 2.51 12.16 2.83 13.69 3.15 15.22 3.47 16.75 3.79 18.28 4.11
30°C 13.36 4.58 13.83 4.65 14.91 4.81 16.42 4.85 16.50 4.76 17.19 4.67
AHUW146A1 35°C 12.15 4.90 13.17 5.08 14.20 5.20 15.35 5.22 15.50 4.69 16.06 5.02 16.71 5.32
(HU141 U31) 40°C 11.65 5.34 12.21 5.49 13.43 5.66 14.28 5.74 14.28 5.15 14.78 5.26 15.34 5.38
45°C 9.35 5.73 10.56 5.87 11.78 6.01 13.00 6.14 14.22 6.28 14.72 6.21 15.23 6.15
Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C
Outdoor Unit
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20°C 13.64 4.17 14.84 4.26 16.03 4.36 17.23 4.45 18.43 4.55 19.62 4.64
30°C 13.72 4.84 14.36 4.91 15.63 5.08 17.30 5.12 17.58 5.18 18.31 5.23
AHUW166A1 35°C 12.48 5.18 13.68 5.37 14.88 5.49 16.17 5.51 16.10 5.07 17.11 5.63 17.80 5.73
(HU161 U31) 40°C 11.96 5.64 12.68 5.80 14.08 5.98 15.03 6.06 15.21 5.54 15.74 5.67 16.34 5.80
45°C 10.17 6.11 11.06 6.10 11.96 6.10 12.86 6.09 13.75 6.09 14.43 6.13 15.10 6.17
Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20°C 12.80 3.49 13.98 3.55 15.16 3.62 15.95 3.66 17.13 3.73 17.92 3.77
30°C 12.33 4.00 13.39 4.06 14.45 4.15 15.16 4.20 16.18 4.28 16.86 4.33
AHUW128A1 35°C 11.94 4.46 13.02 4.56 14.10 4.66 14.33 4.56 14.60 4.02 15.83 4.66 16.43 4.69
(HU123 U31) 40°C 11.45 4.72 12.07 4.91 13.34 5.06 13.70 5.04 14.00 5.10 14.47 5.16 14.93 5.23
45°C 8.59 4.55 9.92 4.65 10.24 4.18 10.46 3.87 11.20 3.90 12.15 3.93 12.82 3.95
Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20°C 13.40 3.97 14.64 4.04 15.88 4.12 16.70 4.17 17.94 4.24 18.76 4.29
30°C 12.70 4.44 13.80 4.51 14.89 4.60 15.62 4.67 16.67 4.75 17.37 4.81
AHUW148A1 35°C 12.30 4.95 13.23 5.00 14.15 5.05 14.77 5.06 15.50 4.65 16.31 5.17 16.93 5.21
(HU143 U31) 40°C 11.79 5.24 12.26 5.39 13.39 5.49 13.71 5.54 14.42 5.66 14.90 5.73 15.38 5.81
45°C 8.59 4.55 9.92 4.65 10.24 4.18 10.46 3.87 11.20 3.90 12.15 3.93 12.82 3.95
Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI TC PI
20°C 11.23 2.92 13.43 3.57 15.56 4.22 16.98 4.65 18.66 4.85 19.78 4.98
30°C 13.75 4.83 14.94 4.91 16.12 5.01 16.92 5.08 18.05 5.17 18.81 5.23
AHUW168A1 35°C 12.50 5.17 14.26 5.36 15.35 5.48 16.20 5.50 16.80 5.09 17.72 5.62 18.33 5.67
(HU163 U31) 40°C 11.99 5.64 13.22 5.77 14.52 5.95 15.04 6.02 15.53 5.57 16.18 5.64 16.83 5.71
45°C 8.59 4.55 9.92 4.65 10.24 4.18 10.46 3.87 11.20 3.90 12.15 3.93 12.82 3.95
Outdoor Unit
Notice : Measuring procedure follows EN-14511
Notice : Above table values may not be matched according to installation condition
AHUW096A1 2 7.13 1.95 6.87 2.07 6.48 2.30 6.35 2.31 6.29 2.57 6.08 2.60
(HU091 U41) 7 9.29 1.98 9.00 2.20 8.43 2.42 8.25 2.44 7.69 2.62 7.37 2.70
10 9.81 2.06 9.71 2.20 9.27 2.35 9.12 2.49 8.11 2.58 7.47 2.61
15 10.34 1.82 10.17 1.82 9.71 2.09 9.44 2.31 8.67 2.59 7.00 2.33
18 10.64 1.85 10.49 1.92 10.03 2.16 9.63 2.35 9.00 2.66 6.71 2.16
Outdoor LWT 30°C LWT 35°C LWT 40°C LWT 45°C LWT 50°C LWT 55°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI
-15 10.13 4.22 9.40 4.10 8.31 4.36 7.95 4.24 7.60 4.75
-7 12.26 4.19 11.48 4.16 10.61 4.53 10.4 4.79 9.48 4.60 7.74 4.21
-2 8.93 2.53 8.65 2.85 8.24 3.05 8.10 3.09 7.94 3.30 7.27 3.54
AHUW126A1 2 9.81 2.69 9.40 2.80 8.79 3.06 8.59 3.06 8.50 3.41 8.17 3.46
(HU121 U31) 7 12.48 2.66 12.00 2.67 11.28 3.20 11.00 3.18 10.3 3.41 9.85 3.58
10 13.49 2.81 13.32 2.99 12.62 3.12 12.4 3.37 11.19 3.69 10.1 3.50
15 14.20 2.50 14.06 2.53 13.34 2.87 12.8 3.16 11.64 3.50 9.40 3.13
18 14.61 2.68 14.51 2.65 13.77 2.94 13.00 3.22 11.92 3.55 8.98 2.90
Outdoor LWT 30°C LWT 35°C LWT 40°C LWT 45°C LWT 50°C LWT 55°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI
Outdoor Unit
-15 11.75 4.97 10.86 4.90 9.54 5.08 9.10 4.97 8.81 5.34
-7 14.03 4.49 13.11 4.85 11.89 5.15 11.40 5.17 10.71 5.24 8.88 4.87
-2 10.62 3.01 10.19 3.30 9.54 3.61 9.32 3.63 9.14 3.95 8.42 4.13
AHUW146A1 2 11.09 3.04 10.69 3.22 10.09 3.58 9.88 3.59 9.78 4.00 9.46 4.04
(HU141 U31) 7 14.46 3.08 14.00 3.15 13.12 3.77 12.80 3.80 11.97 4.08 11.50 4.20
10 15.11 3.17 14.94 3.39 14.27 3.63 14.10 3.83 12.49 3.97 11.60 4.06
15 15.93 2.81 15.65 2.81 14.96 3.21 14.50 3.56 13.35 4.00 10.90 3.62
18 16.38 2.85 16.15 2.95 15.44 3.31 14.80 3.63 13.87 4.10 10.40 3.35
AHUW166A1 2 12.28 3.37 11.90 3.62 11.33 4.00 11.10 4.13 11.03 4.60 10.70 4.62
(HU161 U31) 7 16.40 3.49 16.00 3.81 14.95 4.29 14.60 4.45 13.62 4.77 13.10 4.82
10 17.08 3.62 16.93 3.87 16.29 4.25 16.10 4.38 14.07 4.31 13.10 4.62
15 18.03 3.18 17.59 3.16 16.94 3.64 16.70 4.05 15.44 4.60 12.40 4.11
18 18.55 3.40 18.15 3.32 17.49 3.77 17.00 4.14 16.27 4.77 11.90 3.80
Outdoor LWT 30°C LWT 35°C LWT 40°C LWT 45°C LWT 50°C LWT 55°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI
-15 10.33 4.34 9.56 4.27 8.42 4.44 8.04 4.36 7.66 4.68
-7 12.42 4.32 11.66 4.31 10.49 4.54 10.02 4.61 9.37 4.58 7.73 4.23
-2 9.22 2.64 8.87 2.90 8.32 3.12 8.14 3.16 7.99 3.40 7.31 3.58
AHUW128A1 2 9.74 2.70 9.46 2.83 8.81 3.11 8.63 3.13 8.55 3.49 8.21 3.50
(HU123 U31) 7 12.54 2.71 12.00 2.72 11.49 3.27 11.28 3.31 10.50 3.54 9.94 3.64
10 13.40 2.83 13.25 3.02 12.63 3.22 12.43 3.41 11.20 3.61 10.10 3.53
15 14.04 2.48 13.82 2.49 13.18 2.84 12.77 3.14 11.70 3.51 9.45 3.15
18 14.44 2.62 14.26 2.61 13.61 2.92 13.02 3.20 12.10 3.59 9.05 2.91
Outdoor LWT 30°C LWT 35°C LWT 40°C LWT 45°C LWT 50°C LWT 55°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI
-15 12.04 5.09 11.11 5.07 9.74 5.17 9.29 5.12 8.82 5.26
-7 14.10 4.96 12.72 4.98 11.57 5.09 11.00 5.06 10.60 5.20 8.81 4.86
-2 10.88 3.14 10.38 3.36 9.60 3.64 9.34 3.69 9.18 4.00 8.40 4.14
AHUW148A1 2 11.06 3.09 10.89 3.28 10.10 3.60 9.90 3.66 9.83 4.07 9.43 4.05
Outdoor Unit
(HU143 U31) 7 14.40 3.16 14.00 3.24 13.37 3.82 13.16 3.92 12.30 4.20 11.46 4.22
10 15.21 3.26 15.06 3.49 14.46 3.79 14.26 3.95 12.90 4.04 11.55 4.06
15 15.86 2.80 15.53 2.80 14.89 3.21 14.56 3.56 13.40 4.02 10.85 3.62
18 16.32 2.92 16.02 2.94 15.38 3.31 14.87 3.64 14.10 4.14 10.43 3.35
Outdoor LWT 30°C LWT 35°C LWT 40°C LWT 45°C LWT 50°C LWT 55°C
Model
Temperature TC PI TC PI TC PI TC PI TC PI TC PI
-15 14.09 5.96 12.98 5.98 11.37 6.01 10.83 6.02 10.10 5.92
-7 15.93 6.09 14.92 5.95 12.86 5.74 12.17 5.67 12.00 5.91 9.99 5.54
-2 12.72 3.74 12.08 3.92 11.04 4.20 10.69 4.29 10.50 4.63 9.57 4.74
AHUW168A1 2 12.61 3.60 12.22 3.82 11.55 4.15 11.33 4.26 11.30 4.73 10.75 4.64
(HU163 U31) 7 16.40 3.71 16.00 3.81 15.56 4.42 15.41 4.62 14.40 4.95 13.09 4.84
10 17.49 3.83 17.34 4.10 16.73 4.51 16.53 4.65 15.20 4.69 13.11 4.64
15 18.05 3.19 17.61 3.18 16.95 3.66 16.68 4.07 15.50 4.62 12.36 4.13
18 18.57 3.42 18.17 3.34 17.50 3.79 17.04 4.16 16.30 4.79 11.91 3.82
(dB(A)±3) (dB(A)±3)
1Φ, 220-240V, 50Hz 3Φ, 380-415V, 50Hz
Model Cooling Heating Model Cooling Heating
AHUW096A1 (HU091 U41) 52 52 AHUW128A1 (HU123 U31) 54 53
AHUW126A1(HU121 U31) 54 53 AHUW148A1 (HU143 U31) 54 53
AHUW146A1(HU141 U31) 54 53 AHUW168A1 (HU163 U31) 54 53
AHUW166A1(HU161 U31) 54 53
70 70 70
Octave Band Sound Pressure Level (dB re 20Pa )
40 40 40
AHUW166A1(HU161 U31)
80
70
Octave Band Sound Pressure Level (dB re 20Pa )
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
20 NC-25
Approximate
NC-20
Hearing
Threshold
NC-15
10
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
70 70 70
Octave Band Sound Pressure Level (dB re 20Pa )
80
AHUW166A1(HU161 U31)
70
Octave Band Sound Pressure Level (dB re 20µPa )
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
Outdoor Unit
20 NC-25
Approximate
NC-20
Hearing
Threshold
NC-15
10
63 125 250 500 1000 2000 4000 8000
70 70 70
n Heating(3Ø)
AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31)
80 80 80
70 70 70
Octave Band Sound Pressure Level (dB re 20Pa )
NC-35 NC-35
Outdoor Unit
NC-35
30 30 30
NC-30 NC-30 NC-30
Itʼs a small PCB that either can be fit inside the control box of Indoor unit or can be outside the unit in a plastic case if there
is no sufficient space inside the Indoor unit.
Apart from simple installation, it can also be linked to Central Controller via Indoor unit PI485 pcb. For this, all connecting
wires & an additional small pcb for looping is also provided along with Dry Contact.
So in both of above conditions, system canʼt be operated without signal from external source which prevents unnecessary
use of system & facilitates its operation only when its required.
These settings can be selected from the remote controller whose details have been explained in the later part of this manual
So depending upon the requirement, Dry Contact offers a variety of applications to suit the customerʼs requirement in the
best possible way.
Power
Connector
Indoor PCB
Connector
Accessories
3 4 5 6
1.2.1 Accessory
Cable 1EA
(for Central controller)
Connecting PCB
(6871A30056A)
*for Central Controller
Dry contact
(For installation, 4EA)
Cable 3EA
(for connecting with indoor unit)
Dry contact - 4EA
(For assembly the case)
User/Installation
Accessories
Manual
NOTE
• These cable using for connection between Dry contact and Indoor unit.
• So before using these things Please check the connector type first and use cables on proper indoor unit.
DRY CONTACT
Indoor PCB
PCB 4 4
3 3
CN-CC CN-CC 2 2
1 1
2 1
2 1 AC 220V
- Connection of Dry contact & LG Central Controller in case of single constant models.
Connection PCB
(6871A30056A)
DRY CONTACT
Indoor PCB
PCB 4 4
3 3
CN-CC CN-CC 2 2
1 1
2 1
2 1 AC 220V
BR1
C01A
OSC01B
IC01A
S1
SWITCH
Central Control
(Ex : PHNFP14A0 or PSNFP14A0...)
L1 2 3 4
LED01G
LED02G
LED03G
LED1
ON
U03Y U04Y U02Y
TANS01Y
CN_COMM
C04Y
ZNR01Y
C03Y
* Single Only
- When you install single product this PCB have to add.
Accessories
DRY CONTACT
PCB
4 4 Operation Display
CN-CC 3 3 Error Check Display
RY2 2 2
RY1 1 1 Dry contact
CN_DRY Controller
N L
2 1
2 1
INPUT
AC 220V
LG does not
supply this section
DRY CONTACT
PCB
4 4 Operation Display
CN-CC 3 3 Error Check Display
RY2 2 2
RY1 1 1 Dry contact
CN_DRY Controller
N L
2 1
2 1
INPUT
AC 220V
LG does not
supply this section
Accessories
70mm
Remote Sensor
120mm
Connection Wire
2.1.2 Parts
2. Insert the connector of the connection wire into the space for the
connector in place of the room temperature sensor. (CN_ROOM)
3. Separately, set the option code of the attached controller on the indoor unit.
In detail, refer to "installer setting mode" in the owner's manual.
2.2.2 How to connect the remote temperature sensor and the connection wire
The Connection wire does not matter if you change the color of the wire because of non-polar
Fixing the
Remote Sensor
Accessories
CAUTION
1. Choose the place where the average temperature can be measured for the place the indoor unit operates.
2. Avoid direct sunlight.
3. Choose the place where the cooling/heating devices do not affect the remote sensor.
4. Choose the place where the outlet of the cooling fan do not affect the remote sensor.
5. Choose the place where the remote sensor isnʼt affected when door is open.
2
3
4
ON KSDO4H
5
L1 2 3 4
6
7
8
9
10
11
PI485 GATEWAY(M)
NOTE
Multi-V
ON KSDO4H
L1 2 3 4
PI485 : PMNFP14A0(1EA)
or PMNFP14A1(1EA) BRACKET (1EA) SCREW (4EA)
or PGNFP14A0(1EA)
CAUTION
Accessories
1 2 3 4
5 6 7
5.1 Model
- PHLLA : Sensorʼs limit temperature 100℃
1 2 3
Accessories
Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com