EXPERT IN SAFETY AND CONTENTS

SECURITY TECHNOLOGY Conventional Fire Alarm System


Conventional Photoelectric Smoke Sensor HD101 4
Conventional Fixed & Rate of Rise Heat Sensor HD102 4
Conventional Multi Photoelectric Smoke and Heat Sensor HD103 4
Conventional Ultra Violate Flame Detector HD104-U 5
Conventional Natural Gas Sensor HD105 5
Conventional Manual Call Point HC102 5
Remote Indication LED HS104 6
4 Zones Conventional Fire Alarm Panel HP101-4 6
8 Zones Conventional Fire Alarm Panel HP101-8 6
12 Zones Conventional Fire Alarm Panel HP101-12 7
16 Zones Conventional Fire Alarm Panel HP101-16 7
16 Zones Conventional Fire Alarm Repeater Panel HP103-16 7
Conventional Fire Alarm Panel 4 Zones HP101U-4 8
Conventional Fire Alarm Panel 8 Zones HP101U-8 8
Conventional Fire Alarm Panel 16 Zones HP101U-16 8
Conventional 6"/8"/10" Bell HB101/HB102/HB103 9
Conventional Sound Strobe HS101 9
Conventional Light Strop HS103 9

Fire Fighting Panel & Ex-Proof Detector


Conventional Fire Fighting and Alarm Panel 4 Zones HP102-4 10
Ex-Proof IR/UV Flame Detector with Relay Output HD124-IR/UV-Ex 10
Ex-Proof Gas Detector with Relay Output HD125-Gas-Ex 10

Mini Fire Alarm System


Mini Conventional Fire Alarm Panel 2/4 Zones HP101-2/4 11
Mini 4-Wire Photoelectric Smoke Detector with Relay Output HD101-Mini 11
Mini 4-Wire Photoelectric Smoke & Heat Detector with Relay Output HD103-Mini 11

Fire Alarm System


Product Range Guide Intelligent Addressable Fire Alarm System
Intelligent Addressable Photoelectric Smoke Sensor HD201 12
Intelligent Addressable Fixed Rate of Rise Heat Detector HD202 12
Intelligent Multi Photoelectric Smoke and Heat Sensor HD203 12
Intelligent UV Flame Sensor HD204 13
Intelligent Natural Gas Sensor HD205 13
Intelligent Addressable Manual Call Point HC202 13
Intelligent Addressable Panel 1 to 4 Loop HP201 14
Intelligent Addressable Short Circuit Isolator Module HM201-sc 14
Intelligent Addressable Sounder HS201-R 14
Intelligent Addressable Relay Module HM201-R 15
Intelligent Addressable Switch Monitor HM201-SW 15
Intelligent Addressable Sounder Module HM201-S 15

2
Conventional Fire Alarm System

INTRODUCTION Conventional Photoelectric Smoke Detector


Model: HD101
Over the past twenty years, We have always been dedicated to serving the diverse This Conventional Photo Electric smoke detector use an intelligent optical
sensing chamber.
needs of our customers. Although we started out as a tiny engineering and
This detector is designed to provide open area protection and to be used
manufacturing company in China and have grown into a global player in the with most conventional fire alarm control panels where it can work from
international safety market, We continues to work hard to earn your trust and retain 9Volts to 32V D.C.
your confidence in our product line. It has Two LEDS on each detector to provide a local 360° viewing alarm
Our manufactures thousands of uniquely made smoke, heat and gas detectors indication.
annually, fulfilling a special role or function for each of our customers. We can It flashes every five seconds, indicating that power is applied and the
detector is working properly.
custom-design detectors specifically for your applications. From product design to
final manufacturing, we offer one-stop shopping for your residential and commercial The LEDS latch on in alarm. The LEDS will be off when a trouble
condition occurs, indicating that the detector sensitivity is outside the
detector needs. Any one of our existing product designs can also be modified to listed limit. The alarm can be reset only by a momentary power
meet your specific requirements. In a "one-size-fits-all" world, we works harder to interruption.
tailor our solutions to meet your needs. This detector supports External Remote indication LED.
We are an ISO 9001:2000 certified manufacturer with an extended network of
manufacturing subcontractors and suppliers located nearby. Our company currently Conventional Fixed & Rate-of-Rise Heat Detector
owns a number of testing facilities, such as a UL-standard fire testing lab, a UL test
Model: HD102
box, a dust test chamber, an EN-54 testing tunnel, a buzzer sound-level trial station
This Conventional Fixed & Rate-of-Rise Heat Sensor uses a thermal
and a fluorescent-light interference testing site as well as EMC test equipment. We sensing Element for detection
are also planning to expand our manufacturing and testing facilities in China to This detector is designed to provide open area protection and to be used
ensure that our products and manufacturing practices continue to meet the highest with most conventional fire alarm control panels where it can work from
standards. 9Volts to 32V D.C.
It has Two LEDS on each detector to provide a local 360° viewing alarm
Smoke, heat, and gas detector manufacturing isn’t an easy business to be in. Faced
indication.
with the stiff competition from cheaply made, low-quality detectors, we remain
It flashes every five seconds, indicating that power is applied and the
committed to our customers with high quality products at the most reasonable prices. detector is working properly.
Our focus is to deliver meaningful value to clients that choose our brand over the The LEDS latch on in alarm. The LEDS will be off when a trouble
competition through our commitment to quality. This year we are preparing to condition occurs indicating that the detector sensitivity is outside the listed
introduce our new line of advanced, feature-rich conventional and addressable limit. The alarm can be reset only by a momentary power interruption.
detectors and panels at a competitive price. This detector supports External Remote indication LED.

Conventional Fire Alarm


We invite you to get to know us better. Experience the very best in smoke detector
technology. We are convinced that you will find us superior to any other detector.
You'll see it in our facilities, in our people, and in the products that we makes. It's our
Conventional Multi Photoelectric Smoke & Heat Detector
uncommon commitment to excellence and quality, and to the automation and Model: HD103
This Conventional Multi-detector uses an intelligent optical sensing
productivity of our customers. chamber and a thermal sensor at the same time to detect smoke and
heat.
This detector is designed to provide open area protection and to be used
with most conventional fire alarm control panels where it can work from
9Volts to 32V D.C.
Introduction

It has two LEDS on each detector to provide a local 360° viewing alarm
indication.
It flashes every five seconds, indicating that power is applied and the
detector is working properly.
The LEDS latch on in alarm. LEDS will be off when a trouble condition
occurs indicating that the detector sensitivity is outside the listed limit. The
alarm can be reset only by a momentary power interruption.
This detector supports External Remote indication LED.

3 4
Conventional Fire Alarm System Conventional Fire Alarm System
Conventional Ultra Violate Flame Detector Remote Indication LED
Model: HD104 Model: HS104
This detector uses a very High Sensitivity UV Filter to Detect fast flame The HS104 is a Conventional Remote Indication LED which connects to a
fires. detector to show the alarm conditions on a bright Red Colour LED
Highly reliable, long life UV receptor tube. Optional white or red color cover
Low power consumption. Supports European and USA standards at the same time
HD104 can be intermixed with other types of detection on the panel's Modern style
detection circuitry.
Easily maintained: cleaning can be accomplished without disassembling
the detector.
This detector is designed to be used with most conventional fire alarm
control panels where it can work from 9Volts to 32V D.C.
It has two Led’s on each detector to provide local 360° viewing alarm
indication.

Conventional Natual Gas Detector 4-Zones Conventional Fire Alarm Panel


Model: HD105 Model: HP101-4 HP101-4 is a conventional fire detection control panel and indication
The Gas Detector is designed for single station use. It is small and
compact, small commercial properties and features, It is intended to detect control panel, designed to meet all the requirements of EN54-2&4
leakage of natural gas (methane gas), town gas, and bottled gas (propane Microprocessor-based conventional fire alarm control panel
gas). One man test
4 Detection Zones Panel, 20 to 32 Detectors per Zone
The detector is designed for 9 to 32 Volts D.C., to be installed in major fire 2 Relay outputs for fire condition
alarm panels. The gas Detector can be set high (for methane gas) or low Zones Fault LEDs indication, Zones Isolation LEDs indication
(for propane (LPG) gas). Fault Relay Output, Auxiliary Output for 28Volts
It detects all sorts of combustible gases, natural gas (methane), bottled RS485 Port for repeater up to 1.2Km
gas (propane), LPG (Liquefied petroleum Gas), LNG (Liquefied natural Up to 8 repeaters can be connected to one panel
gas), coal gas, including town gas. 2 sound Outputs
Switched mode power supply 24V,3A with 2 battery chargers 12V
Easy to install, mounting base included. End Of Line Status Detection, Short circuit /open circuit detection
High quality durable sensor. Ideal for all kitchens. Open collector fault output
28V 50mA fused supply output on Fire
Self diagnostic function by MCU intelligent software. Switched mode power supply 3A output
Excellent reliability & high stability.
Conventional Fire Alarm
Conventional Manual Call Point Conventional Fire Alarm 8-Zones Conventional Fire Alarm Panel
Model: HC102 Model: HP101-8
HP101-8 is a conventional fire detection control panel and indication
The HC102 is a conventional call-point based upon our industry standard control panel designed to meet all the requirements of EN54-2&4
series housing, and features easy to install, push-fit wiring terminals. Microprocessor-based conventional fire alarm control panel
One man test
The unit can support either a 'Frangible Glass' element or a 'Non 8 Detection Zones Panel, 32 Detectors per Zone
Frangible Plastic' element. 2 Relay outputs for fire condition
Smoke Alarm

Push in and Pull Down Call Point Zones Fault LEDs indication, Zones Isolation LEDs indication
Fault Relay Output, Auxiliary Output for 28Volts
Can be reset by key RS485 Port for repeaters up to 1.2Km
Red colour Up to 8 repeaters can be connected to one panel
2 sound outputs
Fire proof materials Switched mode power supply 24V,3A with 2 battery chargers 12V
470 Ohm Resistance End of Line Status Detection, Short circuit /open circuit detection
Open collector fault output
Modern style Call Point 28V 50mA fused supply output on Fire
Switched mode power supply 3A output

5 6
Conventional Fire Alarm System Conventional Fire Alarm System
12-Zones Conventional Fire Alarm Panel Conventional Fire Alarm Panel 4 Zones
Model: HP101-12 Model: HP101U-4
HP101-12 is a conventional fire detection control panel and indication General:
control panel designed to meet all the requirements of EN54-2&4
Microprocessor-based conventional fire alarm control panel The HP101U Series Conventional Fire Alarm Control Panel is a 24 volt,
One man test four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel.
12 Detection Zones Panel, 32 Detectors per Zone Designed exclusively to meet the latest market requirements and future
2 Relay outputs for fire condition ULC codes, the highly cost-effective IDC1000 Series can be used in a
Zones Fault LEDs indication, Zones Isolation LEDs indication
Fault Relay Output, Auxiliary Output for 28Volts variety of low- to medium-sized applications.
RS485 Port for repeater up to 1.2Km Specifications:
Up to 8 repeaters can be connected to one panel
2 sound outputs AC POWER : 90 to 270 VAC, 50 Hz, 3.0 amps.
Switched mode power supply 24V,3A with 2 battery chargers 12V Wire size: minimum 14 AWG (2.0 mm²) with 600-volt insulation.
End of Line Status Detection, Short circuit /open circuit detection
Open collector fault output BATTERY: Sealed lead-acid batteries only. Maximum charging circuit:
28V 50mA fused supply output on Fire 27.6VDC @ 0.8 Amp
Switched mode power supply 3A output Features:
Four to Sixteen Zone, Style B (Class B) Initiating Device Circuits (IDCs).
All zones accept two-wire smoke detectors and any normally-open
16-Zones Conventional Fire Alarm Panel Conventional Fire Alarm Panel 8 Zones contact devices.
Model: HP101-16 Model: HP101U-8 Zones 1 - 4/8/16 configured as general alarm zones.
HP101-16 is a conventional fire detection control panel and indication
control panel designed to meet all the requirements of EN54-2&4 All circuits are power-limited and supervised, meeting the latest ULC
Microprocessor-based conventional fire alarm control panel requirements using fuse-less technology.
One man test
One to Four built-in, Style Y (Class B) Notification Appliance (Signal)
16 Detection Zones Panel, 32 Detectors per Zone
2 Relay outputs for fire condition Circuits (NACs).
Zones Fault LEDs indication, Zones Isolation LEDs indication NACs may be programmed: Silence-able. Non-Silence-able. Auto-Silence
Fault Relay Output, Auxiliary Output for 28Volts
(5 to 20 Minutes).
RS485 Port for repeater up to 1.2Km
Up to 8 repeaters can be connected to one panel 1.25 amps of NAC power & 3.0 amps of total system power.
2 sound outputs
Alarm, Trouble and Supervisory, Form-C relays standard. & 24-volt
Switched mode power supply 24V,3A with 2 battery chargers 12V
End of Line Status Detection, Short circuit /open circuit detection operation.
Open collector fault output Resettable four-wire smoke detector power @ 500 mA. Non-resettable
28V 50mA fused supply output on Fire power @ 500 mA.
Switched mode power supply 3A output
Integral battery charger capable of charging up to 18 AH batteries
Conventional Fire Alarm

Conventional Fire Alarm


(batteries over 4 AH require use of the external battery back box, or ULC
listed equivalent).
16 Zones Conventional Fire Alarm Repeater Panel Conventional Fire Alarm Panel 16 Zones
One-man walk-test programmable for silent or audible test.
Model: HP103-16 Model: HP101U-16
Disable/Enable control per IDC.
HP103-16 is a conventional fire alarm repeater panel and indication control Reverse polarity protection.
panel designed to meet all the requirements of EN54-2&4
Microprocessor-based conventional fire alarm repeater panel Control buttons: Mode - Test - ACK (Acknowledge) Alarm Silence - Reset
16 Detection Zones Repeater Panel LED indicators: AC Power (green & yellow LED)- Fire Alarm (red LED) -
Relay output for fire condition
Trouble (yellow LED)
Smoke Alarm

Zones Fault LEDs indication, Zones Fire LEDs indication


RS485 Port for panel connection up to 1.2Km Supervisory (yellow LED) - Signal Silence (yellow LED) - Battery Power
Up to 8 repeaters can be connected to one panel (green & yellow LED)
Sound outputs
24 Volts needed from panel Zone Disable (yellow LED) - NAC Fault (yellow LED) - NAC Disable
4 wire connections to main panel: 2 for power , 2 for RS485 (yellow LED)
This repeater can be connected to any HST type from 4 Zone to 16 Zone Zone Alarm (one for each zone) (red LED) - Zone Trouble (one for each
Panels
zone) (yellow LED)
Earth Fault (on circuit board) - Battery Fault (on circuit board) - Charger
Fault (on circuit board)

7 8
Conventional Fire Alarm System Fire Fighting System & EX-Proof Detector
Conventional 6"/8"/10' Bell Conventional Fire Fighting & 4 Zones Alarm Panel
Model: HB101/HB102/HB103 Model: HP102-4
This conventional Bell has a very low power consumption. HP102-4 is a conventional fire Fighting and detection control panell
designed to meet all the requirements of EN54-2&4
Voice volume: 96dB/(mA)
Microprocessor-based conventional fire fighting & alarm control panel
Rated current: 10 to 18 mA 4 Detection Zones Panel, 1 Fire Fighting Area, 20 to 32 Detectors per
Size: 6"/8"/10" of DC 24V Zone
Temperature: -10 ~ 60° Relay output for fire condition, Relay output for double knock condition
Zones Fault LEDs indication, Status for all steps of fire fighting
Humidity: at or below 93%
Fault Relay Output, Auxiliary Output for 28 Volts
Material : steel Sound output for Alarm & firefighting Condition
Water Proof Up to 8 repeaters can be connected to one panel
Switched mode power supply 24 V,3A with 2 battery chargers 12V
End of Line Status Detection, Short circuit /open circuit detection
Release switch for gas release, Manual automatic switch control
Hold Switch, Enable / Disable key switch

Conventional Sound Strobe Ex-Proof IR/UV Flame Detector with Relay Output
Model: HS101 Model: HD124 - IR/UV-Ex
This Conventional Siren has a very low power consumption. Compatible with all the fire alarm and gas detection system
Rated Voltage: 24 Volts Response to a flame more than 25m away
Rated current: 50mA Unaffected by convention currents, draughts or wind and solar-blind
Sound: 89dB/3m(A) Tolerant of fumes, vapours, dust and mist
Light Output: ≥ 1.2WS Alarm Relay Output(NO/NC can be adjustable)
Flash Rate: ≤ 2 seconds Unpolarized wire input
Wide range of operating voltages(9V~28VDC)
Material: Fire Proof Plastic
Quick Detection of IR/UV Flame from Distance
Temperature:-10 to 60° Built in microprocessor intelligent software
Humidity:≤93%

Fire Fighting & Ex-Proof


Conventional Fire Alarm

Conventional Light Strob Ex-Proof Gas Detector with Relay Output


Model: HS103 Model: HD125-Gas-Ex:
Operating Temperature: -10°C to 50°C
Compatible with all the fire alarm and gas detection system
Operating Humidity: 0 to 95 RH, No condensation or icing Unaffected by convention currents, draughts or wind
Operating Voltage: 22 VDC to 30 VDC Tolerant of fumes, vapours, dust and mist
Smoke Alarm

Average Current 70 mA Alarm Relay Output(NO/NC can be adjustable)


Light Output: ≥ 1.2WS Unpolarized wire input
Flash Rate: ≤ 2 seconds Wide range of operating voltages(9V~28VDC)
Quick Detection of gas from Distance
Sound Level: ≥ 100 dB
Built in microprocessor intelligent software
Light Life: ≥ 30000 flashes

9 10
Mini Fire Alarm System Intelligent Addressable Fire Alarm System
Mini Conventional Fire Alarm Panel 2/4 Zones Intelligent Addressable Photoelectric Smoke Detector
Model: HP101-2/4 Model: HD201
HP101-2/4 is a conventional fire detection control panel and indication This Intelligent Addressable Photo-Electric Smoke Detector uses an
control panel designed to meet all the requirements of EN54-2&4
intelligent optical sensing chamber.
Microprocessor-based conventional fire alarm control panel.
This detector is designed to provide open area protection and to be used
2/4 Detection Zone Panels, 20 to 32 Detectors per Zone
with our HST Protocol panels.
2 Relay outputs for fire condition
It has two LEDs on each detector to provide a local 360° viewing alarm
Zones Fault LEDs indication, Fault Relay Output
indication.
2 sound outputs
It flashes every five seconds, indicating that power is applied and the
Switched mode power supply 24V,3A with 1 battery charger 12v
detector is working properly.
End of Line Status Detection, Short circuit /open circuit detection
The LEDs latch on in alarm. The LEDs will be off when a trouble condition
Open collector fault output
occurs, indicating that the detector sensitivity is outside the listed limit.
28V 50mA fused supply output on fire
The alarm can be reset only by a momentary power interruption.
Switched mode power supply 3A output
This detector supports External Remote indication LED.
Simple Double Knock fire fighting fucntion

4-Wire Photoelectric Smoke Detector with Relay Output Intelligent Addressable Fixed & Rate-of-Rise Heat Detector
Model: HD101-Mini Model: HD202
This Intelligent Addressable Fixed & Rate-of-Rise Heat Sensor uses a
This Mini Detector uses an intelligent optical sensing chamber. thermal sensing element for detection
Compatible with all the security and fire alarm system This detector is designed to provide open area protection and to be used
Mini Size suitable for all installed inside cabinet with our HST Protocol panels.
It has two LEDs on each detector to provide a local 360° viewing alarm
Alarm Relay Output(NO/NC can be adjustable)
indication.
Unpolarized wire input
It flashes every five seconds, indicating that power is applied and the
Wide range of operating voltages(9V~28VDC)
detector is working properly.
Unique optical sensing chamber
The LEDs latch on in alarm. The LED’s will be off when a trouble
Two LEDs blink standby, provide 360° visibility
condition occurs, indicating that the detector sensitivity is outside the
Insect-resistant screening
listed limit. The alarm can be reset only by a momentary power
Drift compensation and smoothing algorithms
interruption.
Mini Fire Alarm System This detector supports External Remote indication LED.

4-Wire Photoelectric Smoke & Heat Detector with Relay Output Addressable Fire Alarm Intelligent Addressable Multi Photoelectric Smoke & Heat Detector
Model: HD103-Mini Model: HD203
This Intelligent Addressable Multi-Detector uses an intelligent optical
This Mini Multi-Detector uses an intelligent optical sensing chamber and a sensing chamber and a thermal sensor at the same time to detect smoke
thermal sensor at the same time to detect smoke and heat. and heat.
Compatible with all the security and fire alarm system This detector is designed to provide open-area protection and to be used
Mini Size suitable for all installed inside cabinet
Smoke Alarm

with our HST Protocol panels.


Alarm Relay Output(NO/NC can be adjustable) It has two LEDs on each detector to provide a local 360° viewing alarm
Unpolarized wire input indication.
Wide range of operating voltages(9V~28VDC) It flashes every five seconds, indicating that power is applied and the
Unique optical sensing chamber detector is working properly.
Two LEDs blink standby, provide 360° visibility The LEDs latch on in alarm. The LEDs will be off when a trouble condition
Insect-resistant screening occurs indicating that the detector sensitivity is outside the listed limit. The
Drift compensation and smoothing algorithms alarm can be reset only by a momentary power interruption.
This detector supports External Remote indication LED.

11 12
Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System
Intelligent Addressable Ultra Violate Flame Detector Intelligent Addressable Fire Alarm Panel 1-4 Loops
Model: HD204 Model: HP201
HP201 (IRIS) is an addressable fire detection and indication control panel
This detector uses a very High Sensitivity UV Filter to detect fast flame designed to meet all the requirements of EN54. Certificate EN541-2/4
fires. Modular type panel, 1 to 4 Loop Panel
Highly reliable, long life UV receptor tube 318 addresses per loop (159 detectors / 159 modules )
Low power consumption 1272 Device maximum per panel
96 programming zones for each programming zone delay
HD204 can be intermixed with other types of detection on the panel's 128 programmable input output
detection circuitry. 8 Cause-and-Effect scan be programmed
Easily maintained: cleaning can be accomplished without disassembling Color Graphics LCD 320X240 displaying fire fault and messages
the detector. Touch screen display to operate the panel easily
This detector is designed to be used with most HST Addressable TCP/IP port for programming and networking, up to 32 panels or
repeaters in one network, also used for software monitoring function
Protocols. USB Port for programming and firmware upgrade
It has two LEDs on each detector to provide a local 360° viewing alarm Day/Night setting for detectors , 10000 Event Log Memory
indication. 4 Programmable Relay output, 4 Programmable sound outputs
This detector supports External Remote indication LED. Switched mode power supply 12V,4A with battery charger 12v,18AH
Supports HST or SYSTEM SENSOR protocol

Intelligent Addressable Natural Gas Detector Intelligent Addressable Short Circuit Isolator Module
Model: HD205 Model: HM201-SC
The Gas Detector is designed for single station use. It is small and Model HM201-SC is a negative-switching Loop Isolator, which is
compact, small commercial properties and features. It is intended to fully compatible with HST intelligent addressable protocol.
detect leakage of natural gas (methane gas), town gas, and bottled gas The module incorporates an amber LED to show when it is isolating
(propane gas). a section of the loop, and when used under each addressable
The detector is designed to use HST Addressable Protocol panels. The sensor. If a single short circuit was to occur on the loop, then no
gas Detector can be set high (for methane gas) or low (for propane (LPG) Sensors would be lost.
gas). The HM201-SC does not use an address, and has the same wiring
It detects all sorts of combustible gases, natural gas (methane), bottled configuration as the HD200 Base, making it very simple to install.
gas (propane), LPG (Liquefied petroleum Gas), LNG (Liquefied natural Detects short circuits on loop
gas), coal gas, including town gas. Status LED
Easy to install, mounting bracket included. Allows connection of sensors from the HST Range
High quality durable sensor. Bayonet slot, low insertion force for detectors
Self-diagnostic function by MCU intelligent software. Quick connection via square cable clamps
Excellent reliability & high stability, Ideal for all kitchens.

Addressable Fire Alarm


Addressable Fire Alarm
Intelligent Addressable Manual Call Point Intelligent Addressable Sounder
Model: HC202 Model: HS201-R Model HS201-R is an addressable loop powered addressable sounder
The HC202 is an intelligent Addressable Call-Point based upon our innovatively designed to provide a range of tones and volumes with a
industry standard series housing and features easy to install, push-fit maximum output of up to 85dB(A) (±2dB(A)) with low current
wiring terminals. consumption.
The unit is designed to fit into the Standard Base (HD200)(RED). It also
Push in and Pull Down Call-Point
incorporates an auto shutdown mode* which allows the user to set a fixed
Smoke Alarm

Can be reset by key time within which the sounder will operate, before automatically silencing
Red colour itself, ideal for minimising noise pollution.
Fire proof materials Loop Powered
Single Loop Address - addressed via the Hand Held Programmer
HST Addressable Protocol
Variable Sound Output 70 ~ 85dB(A) (±2dB(A)) output at 1 metre
Modern style Call-Point Fits HST Standard or HD200 Base
Weatherproof Kit available
51 User-Selectable Tones (all tones EN54-3 compatible)
Also available in white

13 14
Intelligent Addressable Fire Alarm System
Intelligent Addressable Relay Module
Model: HM201-R
Model HM201-R is a single Relay Controller designed to provide one
general-purpose relay output; this output can be driven separately for
control of such devices as dampers or for control of plant and equipment
shutdown.
Loop Powered
Single Address
One Relay Controlled by loop
Relays Contact Rated at 30Vdc at 1 amp

Intelligent Addressable Switch Monitor


Model: HM201-SW
Model HM201-SW is a single Switch Monitor designed to interface in a
variety of inputs such as door contacts, sprinkler flow/door switches and
plant equipment to the HST Addressable system.
Single Loop Address
Loop Powered
One Inputs for Monitoring of Volt Free Contacts
This Input can be Configured to Monitor either Normally Open or Normally
Closed contacts

Addressable Fire Alarm


Intelligent Addressable Sound Module EXPERT IN SAFETY AND
Model: HM201-S
Single Loop Address SECURITY TECHNOLOGY
Each alarm circuit fused at 1 amp
One Sounder Circuit
Each circuit fully monitored for open and short circuit faults
Smoke Alarm

Outputs can be driven Continuously or Synchronized Pulsed Sounder


Drive
Model HM201-S is an intelligent sounder module which has been
designed to provide one sounder output (that can be driven by Bell or HST-HLogic Security Technology
Siren) with full fault monitoring. The monitored input can be used for local http://www.hstfire.com(International)
power supply fault monitoring or as a general-purpose input. http://www.hstfire.us(U.S.A)
The HM201-S utilises simple DIP switches for reliable addressing. http://www.hstfire.co.uk(U.K)
http://www.hstfire.cn(China Factory)