Easy Altivar ATV310 complete parameters list ENGLISH

EAV9613608
Reference mode F005 Invalid industrialization zone 203 Logic inputs type 216.1 AO1 type 405 Stop key priority
Reference menu

402 External reference value F006 Current measurement circuit [00]* Positive [10U] Voltage: 0-10 Vdc [00] No: Stop inactive

I/O menu (cont.)


403 Integrated display jog dial reference F007 Internal thermal sensor fault [01] Negative internal supply [0A]* Current: 0-20 mA [01]* Yes: Stop active
801 Speed reference F008 Internal CPU [02] Negative external supply [4A] Current: 4-20 mA 406 Channel configuration
F009 Overbraking 204- AI1 CONFIGURATION MENU 217 Speed Template [01]* Combined mode
59.11 Internal PID reference [02] Separate mode
806 PID reference value F010 Overcurrent 204.0 AI1 type [BSD]* Standards
F011 Drive overheat [5U]* Voltage: 0-5Vdc [BLS] Pedestral 407 Command channel 1
Monitoring mode [01]* Terminals

Control menu (cont.)


F012 Process overload [10U] Voltage: 0-10Vdc [BNS] Deadband
402 External reference value F013 Motor overload [BNS0] Deadband at 0% [02] Local
[0A] Current: x-y mA [03] Remote display
403 Integrated display jog dial reference F014 1 Output phase loss [LIU] Logic inputs 300- MOTOR CONTROL MENU
Monitoring parameter

801 Speed reference F015 3 Output phases loss [10] Modbus


204.1 AI1 current scaling parameter of 0% 301 Standard motor frequency 408 Forced local assignment

Detected fault codes


802 Output frequency F016 Main overvoltage 0-20mA (4mA*) [00]* 50Hz [00]* No: Function inactive
803 Motor current F017 Input phase loss 204.2 AI1 current scaling parameter of 100% [01] 60Hz [L1H] LI1 active High
804 PID error F018 Motor short-circuit 0-20mA (20mA*) 302 Rated motor power [L2H] LI2 active High
805 PID Feedback F019 Ground short-circuit 204.3 AI1 filter time Drive power (-5 to +2) depending on drive rating [L3H] LI3 active High
806 PID reference F020 IGBT short circuit 0 s to 10 s (0 s*) 303 Rated motor cos phi [L4H] LI4 active High
807 Main voltage F021 Load short circuit 205 R1 assignment 0.5 to 1 (depending on drive rating) [LUH] LIU active High
808 Motor thermal state F022 Modbus interruption [00] Not assigned 304 Rated motor voltage 409 Forced local reference
809 Drive thermal state F024 HMI communication [01]* No error detected 360 to 460V (380V*) [00]* Not assigned
810 Output power F025 Overspeed [02] Drive run 305 Rated motor current [01] Terminal
811 Product status F026 PI feedback fault [04] Frequency threshold reached 0.25 to 1.5In (depending on drive rating) [163] Remote display

1 3
[-00] Drive ready F027 IGBT overheat [05] HSP reached 306 Rated motor frequency [183] Integrated jog dial
[-01] Drive running F028 Autotuning fault [06] I threshold reached 10 to 400Hz (50Hz*) 500- FUNCTION MENU
[-02] Acceleration F029 Process underload fault [07] Frequency reference reached 307 Rated motor speed 501- RAMP MENU
[-03] Deceleration F030 Undervoltage [08] Motor thermal reached 0 to 24000rpM (depending on drive rating) 501.0 Acceleration
[-04] DC injection braking in progress F031 Incorrect configuration [21] Process underload fault 308 Maximum frequency 0.0 to 999.9s (3.0s*)
[-05] Current limitaion state F032 Invalid configuration [22] Process overload fault 10 to 400Hz (60Hz*) 501.1 Deceleration
Drive status

[-06] Freewheel stop control or freewheel state F033 AI1 current loss [123] Loss of 4-20mA signal 309 Motor control type 0.0 to 999.9s (3.0s*)
[-07] Auto-adatated deceleration F034 Download invalid configuration 206- LO1 CONFIGURATION MENU [00] Performance: Vector control 501.2 Ramp shape assignment
[-08] Controlled stop on mains phase loss F035 Pre-charge resistor protection fault 206.0 LO1 Assignment [03]* Standard: U/F 2 points [00]* Linear
[-09] Auto-tuning in progress Configuration mode [00]* Not assigned [06] Pump: U²/F [01] S shape
[-10] Fast stop state 301 Standard motor frequency [01] No error detected 310 IR compensation [02] U shape
[-11] No line power state [00] 50Hz IEC [02] Drive run 25 to 200% (100%*) 501.3 Ramp switching commutation
[-12] Drive in back state [01] 60Hz NEMA [04] Frequency threshold reached 311 Slip compensation [00]* Not assigned

Motor control menu

Function / Ramp menu


I/O menu (cont.)
[-13] Remote control mode 401 Reference channel 1 [05] HSP reached 0 to 150% (100%*) [L1H] LI1 active High
[-14] Local control mode [01] Terminal [06] I threshold reached 312 Frequency loop stability [L2H] LI2 active High
900- MAINTENANCE MENU [07] Frequency reference reached 0 to 100% (20%*) [L3H] LI3 active High
[163] Remote display [L4H] LI4 active High
901 State of logic inputs LI1 to LI4 [164] Modbus [08] Motor thermal reached 313 Frequency loop gain
902 State of the logic output LO1 and relay R1 [21] Process underload fault 0 to 100% (20%*) [LUH] LIU active High
[183] Integrated display with Jog dial [L1L] LI1 active low
903 Display of high speed value 501.0 Acceleration [22] Process overload fault 314 Flux Profil
904 Drive Power rating 0 to 100% (20%*) [L2L] LI2 active low
0.0 s to 999.9s (3.0s*) [123] AI1 alarm 4-20mA [L3L] LI3 active low
037 501.1 Deceleration [126] Auxiliary pump active 315 Switching frequency
075 2 to 12kHz (4kHz*) [L4L] LI4 active low
0.0 s to 999.9s (3.0s*) 206.1 LO1 status (output active level) [LUL] LIU active low
U15 512.0 Low speed [00]* Positive : hight activation level 317 Motor noise reduction 501.4 Acceleration 2
U22 0.0Hz to High speed (0Hz*) [01] Negative : low activation level [00]* No 0.0 to 999.9s (5.0s*)
U30 207 Process overload time delay [01] Yes 501.5 Deceleration 2
512.2 High speed
Short menu

U40 0 to 100 s (0 s*) 318 Auto-tuning 0.0 to 999.9s (5.0s*)


U55 Low speed to Max frequency (50 or 60Hz
determined by 301 parameter value ) 208 Process overload threshold [00]* No: Use factory paramameters of stan- 501.6 Decel Ramp Adaptation assignment
U75 70 to 150% of nominal motor current (90%*) dard motors [00] Function deactivated
D11 302 Rated Motor Power
NCV -5 to NCV +2 (according to drive rating*) 209 Process overload fault duration [01] Yes: Request auto-tuning [01]* Function activated
D15 [02] Done: Auto-tuning has already been [02] Motor brake
D18 305 Rated motor current 0 to 6 min (0 min*)

2 4
performed
Maintenance menu

D22 (0.25-1.5In) (depending on drive rating) 210 Process underload time delay 502- STOP CONFIGURATION MENU
204.0 AI1 type 0 to 100 s (0 s*) 319 Motor parameter choice 502.0 Type of stop
905 Drive voltage rating [00]* Nominal motor power [00]* Ramp stop
N4 [5U]* 0-5V 211 Process underload threshold
20 to 100% of nominal motor current (60%*) [01] Nominal motor cos phi [03] DC injection stop
906 Specific Product Number [10U] 0-10V [08] Fast stop
[0A] x-y mA 212 Process underload fault duration 320 Vector control 2 points
907 Card 1 Software Version [00]* No [13] Free wheel stop
908 Card 2 Software Version [LIU] Logic inputs 0 to 6min (0min*)
213 Motor frequency threshold [01] Yes 502.1 Freewheel stop assignment
909 Run elapsed time display 101 Store customer parameter set [00]* Not assigned
910 Power On time display [00]* Disabled 0 to 400Hz (50Hz* or 60Hz) 321 Max voltage of constant power
[L1L] LI1 active Low to stop

Function / Stop configuration menu


911 Fan time display [01] Stores current configuration 214 Motor current threshold 360 to 460V (380V*)
322 Max frequency of constant power [L2L] LI2 active Low to stop
912 Process Elapsed time 102 Factory / recall customer parameter set 0 to 1.5In (In*) [L3L] LI3 active Low to stop
913 Modbus communication status [00]* Disabled 50 to 400Hz (50Hz*) [L4L] LI4 active Low to stop
215 Motor thermal state threshold 323 Dual Rating
914 Last fault 1 [02] Customer configuration 0 to 118% (100%*) [LUL] LIU active Low to stop
915 State of drive at fault 1 [64] Factory set configuration [00] Normal duty 502.2 Fast stop assignment
216.0 AOI assignment [01]* Heavy duty [00]* Not assigned
916 Last fault 2 COMPLETE MENU
917 State of drive at fault 2 [00]* Not assigned 400- CONTROL MENU [L1L] LI1 active Low to stop
100 Macro-configuration [129] Motor current 401 Reference channel 1
Macro

918 Last fault 3 [00] Start/stop [L2L] LI2 active Low to stop
919 State of drive at fault 3 [130] Output frequency [01] Terminal [L3L] LI3 active Low to stop
[04] PID regulation [131] Ramp output [163] Remote display
920 Last fault 4 [09] Speed [L4L] LI4 active Low to stop
[164] Modbus

Control menu
921 State of drive at fault 4 [135] PID reference [LUL] LIU active Low to stop
200- I/O MENU [136] PID feedback [183] Integrated display with Jog dial
999 HMI Password 201 Type of control 402 External reference value 502.3 Ramp divider
F000 Fault list [137] PID error 1 to 10 (4*)
[00]* 2-wire control [139] Output power -400 to 400Hz
I/O menu

F001 Precharge [01] 3-wire control 403 Integrated display jog dial reference 502.4 DC injection assignment
F002 Unknown drive rating [140] Motor thermal state [00]* Not assigned
202 2-wire type control [141] Drive thermal state 0 to 100%
F003 Unknown or incompatible power board [00] Level 404 Reverse inhibition [L1H] to [L4H] LI1 to LI4 active High
F004 Internal serial link [01]* Transition [00]* No [LUH] LIU active High
[02] Forward priority [01] Yes
The (*) indicates a parameter factory setting.

www.se.com 1/2
Easy Altivar ATV310 complete parameters list
502.5 DC injection level 512.3 2 High speed assignment 609 4-20mA loss Behaviour

Modbus Det. fault 4-20 mA


0.1 to 1.41In (0.64 In*) 507.7 Preset speed 6 59.21 Sleep offset threshold [00]* Not assigned [00]* Detected fault ignored

Speed limitation function (cont.)

loss
502.6 IDC injection time for DCLI 0 to 400Hz (30Hz*) 0 to High speed (0Hz*) [L1H] to [L4H] LI1 to LI4 active High [01] Freewheel stop

PID Control function (cont.)


0.1 to 30 s (0.5 s*) 507.8 Preset speed 7 59.22 PID feedback supervision threshold [LUH] LIU active High [08] DC injection stop
502.7 DC injection level 2 0 to 400Hz (35Hz*) 0 to 100% (0%*) 512.4 4 High speed assignment 610 Detected fault inhibition assignment
0.1 to 1.41In (0.5 In*) 507.9 Preset speed 8 59.23 PID supervision function time delay [00]* Not assigned [00]* Function inactive

frequency

interrup. inhibit.
0 to 400Hz (40Hz*)

Jump
502.8 Injection standstill braking time 0 to 600s (0s*) [L1H] to [L4H] LI1 to LI4 active High [L1H] to [L4H] LI1 to LI4 active High
0.1 to 30 s (0.5 s*) 508 Skip frequency 59.24 Maximum frequency detection Hysteresis [LUH] LIU active High [LUH] LIU active High
503 Reverse direction 0 to 400Hz (0Hz*) 0 to 50Hz (0Hz*) 512.5 High speed 2 611 Modbus detected fault management
reverse direction

[00]* Not assigned 59- PID MENU 59.25 PID feedback supervision Low speed to Max frequency (50 or 60Hz*) [00]* Detected fault ignored
59.00 PID feedback assignment
Function

[L1H] LI1 active High [00]* Not assigned 512.6 High speed 3 [01] Freewheel stop
[L2H] LI2 active High [00]* Not assigned [01] Free wheel Low speed to Max frequency (50 or 60Hz*) [08] DC injection stop
[L3H] LI3 active High [01] Terminal [04] Fallback speed 512.7 High speed 4 612 Degraded line supply operation
59.01 PID proportional gain [00]* No

Degr.
[L4H] LI4 active High 59.26 Fallback speed Low speed to Max frequency (50 or 60Hz*)

line
[LUH] LIU active High 0.01 to 100 (1*) 0 to High speed (0Hz*) 513 Cooling fan control [01] Yes
504- AUTO DC INJECTION MENU 59.02 PID integral gain 510- PUMP SUB-MENU [00] Fan runs when drive runs 613 Reset power run

Fan
DC injection function

504.0 Automatic DC injection 0.01 to 100 (1*) 207 Process overload time delay [01]* Thermal control [00]* No
59.03 PID derivative gain [03] Reset drive running time

Reset power run


[00] Function inactive, no DC injected current. 0 to 100 s (0 s*) 600- FAULT DETECTION MANAGEMENT MENU

Detected fault reset


[01]* Time limited DC injection 0.00 to 100.0 (0*) 208 Process overload threshold 601 Detected fault reset assignment [04] Reset power-on time
[02] Continuous DC injection 59.04 PID feedback scale factor 70 to 150% of nominal motor current (90%*) [00]* Not assigned [07] Reset fan operation time
504.1 Automatic DC injection current 0.1 to 100.0 (1.0*) 614 Reset all previous detected faults via Run key

7
209 Process overload fault duration [L1H] LI1 active High

5
0 to 120% of nominal motor current (70%*) 59.05 Activation internal PID reference 0 to 6 min (0 min*) [L2H] LI2 active High of HMI
504.2 Automatic DC injection time [00]* No 210 Process underload time delay [L3H] LI3 active High [00]* Deactivated
0.1 to 30s (0.5s*) [01] Yes 0 to 100 s (0 s*) [L4H] LI4 active High [01] Active
505.0 Jog assignment 59.06 2 preset PID assignment 211 Process underload threshold [LUH] LIU active High 700- COMMUNICATION MENU
[00]* Not assigned [00]* Not assigned 20 to 120% of nominal motor current (60%*) 602- AUTOMATIC RESTART MENU 701 Modbus address
Jog function

[L1H] LI1 active High [L1H] LI1 active High Off to 247 (off*)

PID / Pump mangement function


212 Process underload fault duration 602.0 Automatic restart
[L2H] LI2 active High [L2H] LI2 active High 0 to 6min (0min*) [00]* No 702 Modbus baud rate

after a etected fault


[L3H] LI3 active High [L3H] LI3 active High [24] 4.8 kbps

Automatic restart
510.0 Selecting operating mode [01] Yes
[L4H] LI4 active High [L4H] LI4 active High [00]* Single frequency conversion mode 602.1 Max. automatic restart [28] 9.6 kbps
[LUH] LIU active High [LUH] LIU active High [01] Single frequency conversion combined [00]* 5 min [32]* 19.2 kbps
505.1 Jog frequency 59.07 4 preset PID assignment with auxiliary pump mode [01] 10 min [36] 38.4 kbps
0 to10Hz (*5Hz) [00]* Not assigned 510.1 Starting frequency of the auxiliary pump [02] 30 min 703 Modbus format
506- Speed up and down [L1H] LI1 active High 0 to 60Hz (50Hz*) [03] 1 hour [02] 8o1
506.0 Up speed command [L2H] LI2 active High 510.2 Time delay before starting auxiliary pump [04] 2 hours [03]* 8E1
[00]* Not assigned [L3H] LI3 active High 0 to 999.9s (2s*) [05] 3 hours [04] 8n1
[L1H] to [L4H] LI1 to LI4 active High [L4H] LI4 active High 510.3 Auxiliary pump ramp reaching [06] Infinite [05] 8n2
[LUH] LIU active High [LUH] LIU active High 704 Modbus time out
Motor potentiometer function

0 to 999.9s (2s*) 603 Catch on the fly

on
506.1 Down speed command 59.08 2 preset PID reference 0.1 to 30s (10s*)

the fly
510.4 Auxiliary pump stop frequency [00]* Function inactive

Motor thermal protection Catch


PID Control function

[00]* Not assigned 0 to 100% (25%*) 0 to 60Hz (0Hz*) [01] Function active 705- INPUT SCANNER MENU
[L1H] to [L4H] LI1 to LI4 active High 59.09 3 preset PID reference 510.5 Auxiliary pump stop time delay 604- MOTOR THERMAL PROTECTION MENU 705.0 Com scanner read adress parameter 1
[LUH] LIU active High 0 to 100% (50%*) 0 to 999.9s (2s*) 604.0 Motor thermal current 0C81*
506.2 Store 59.10 4 preset PID reference 510.6 Auxiliary pump stop ramp 0.2-1.5In (According to drive rating*) 705.1 Com scanner read adress parameter 2
[00]* No 0 to 100% (75%*) 0 to 999.9s (2s*) 604.1 Motor protection type 219C*
[01] RAM 59.11 Internal PID reference 510.7 Zero flow detection period [01]* Self-ventilated 705.2 Com scanner read adress parameter 3
[02] ROM 0 to 100% (0%*) 0 to 20min (0min*) [02] Motor-ventilated 0000
506.3 Clear the function 59.12 PID reference ramp 510.8 Zero flow detection activation threshold 604.2 Overload fault management 705.3 Com scanner read adress parameter 4

Communication menu
[00]* Not assigned 0 to 99.9s (0s*) 0 to 400Hz (0Hz*) [00] Detected fault ignored 0000
[L1H] to [L4H] LI1 to LI4 active High 59.13 PID min value reference 510.9 Zero flow detection offset [01]* Free wheel stop
0 to 100% (0%*) [08] DC injection stop 706- OUTPUT SCANNER MENU
[LUH] LIU active High 0 to 400Hz (0Hz*) 706.0 Com scanner write adress parameter 1
59.14 PID max value reference 604.3 Motor thermal state memo

8
[159] Acceleration and decele-

6
0 to 100% (100%*) 511- CURRENT LIMITATION MENU [00]* thermal state not stored at power off 2135*
ration with command 511.0 2nd current limitation commutation 706.1 Com scanner write adress parameter 2
active high 59.15 PID predictive speed [01] thermal state is stored at power off
0.1 to 400Hz (0.0*) [00]* Not activated 605 Output Phase loss 219A*
506.4 Reactivity of +/- speed [L1H] LI1 active High 706.2 Com scanner write adress parameter 3
[00] Deactivated
Current limiration function

around ref. 501.4 Acceleration 2


[L2H] LI2 active High [01]* Tripping then freewheel stop 0000

Phase loss
0 to 100% (0%*) 0.0 to 999.9s (5s*)
59.16 PID correction reverse [L3H] LI3 active High 606 Input Phase loss 706.3 Com scanner write adress parameter 4
507- PRESET SPEED MENU [L4H] LI4 active High [00] Detected fault ignored 0000
507.0 2 Preset speeds [00]* No, no negative speed
[01] Yes, no negative speed [LUH] LIU active High [01]* Detected fault with freewheel stop 707- INPUT SCANNER ACCESS MENU
[00]* Not assigned [L1L] LI1 active Low [08] DC injection stop 707.0 Com scanner read adress value 1
[L1H] LI1 active High [02] No, allow negative speed
[03] Yes, allow negative speed [L2L] LI2 active Low 607- UNDERVOLTAGE MENU 0C81*
[L2H] LI2 active High [L3L] LI3 active Low 607.0 Undervoltage detected fault management 707.1 Com scanner read adress value 2
Preset speed function

[L3H] LI3 active High 59.17 PID auto/manual assignment


[00]* Not assigned [L4L] LI4 active Low [00]* Detected fault and R1 relay set 0 219C*

Undervoltage
[L4H] LI4 active High [LUL] LIU active Low [01] Detected fault and R1 relay set 1 707.2 Com scanner read adress value 3
[LUH] LIU active High [L1H] to [L4H] LI1 to LI4 active High
[LUH] LIU active High 511.1 Current limitation 607.1 Undervoltage prevention 8000
507.1 4 Preset speeds 0.25 to 1.5In (1.5In*) [00]* No action (freewheel) 707.3 Com scanner read adress value 4
same as 2 Preset speeds 59.18 PID manual reference
[00]* No 511.2 Current limitation 2 [02] Stop following an adjustable ramp 8000
507.2 8 Preset speeds 0.25 to 1.5In (1.5In*) 607.2 Undervoltage ramp deceleration time 708- OUTPUT SCANNER ACCESS MENU
same as 2 Preset speeds [01] Terminal 0.0 to 10.0s (1.0s*)
[183] Integrated jog dial 512- SPEED LIMIT MENU 708.0 Com scanner write adress value 1
507.3 Preset speed 2 512.0 Low speed 607.3 Precharge resistor protection level
0 to 400Hz (10Hz*) 512.1 Low speed operating time CMD value*
Speed limitation

0Hz to high speed (0Hz*) 430 to 560 VDC (0 V* with protection removed) 708.1 Com scanner write adress value 2
507.4 Preset speed 3 0.1 to 999.9s (0s*) 608 IGBT test
512.1 Low speed operating time
function

0 to 400Hz (15Hz*) 59.19 PID: wake up level [00]* No test LFRD value*
507.5 Preset speed 4 0 to 100% (0%*) 0.1 to 999.9s (0s*) 708.2 Com scanner write adress value 3
512.2 High speed
IGBT [01] Starting test
0 to 400Hz (20Hz*) 59.20 PID: Wake up threshold 8000
507.6 Preset speed 5 0 to 100% (0%*) Low speed to Max frequency (50 or 60Hz deter- 708.3 Com scanner write adress value 4
0 to 400Hz (25Hz*) mined by 301 parameter value) 8000

The (*) indicates a parameter factory setting.