Professional Documents
Culture Documents
final TL lab book (معمل النظم)
final TL lab book (معمل النظم)
Table 2.1. Calculated and measured values for line length 150 km.
Table 2.2. Calculated and measured values for line length 300 km.
2.3 Questions.
• Explain why the receiving end voltage is greater than the sending end
voltage?
• Calculate the shunt branches currents for line length 150 km.
• Repeat the calculations for line length 150 km using short model
equations, comment.
Vsph=(380/ 3 ) v , f=50 Hz
XL=2πfL=0.242 Ω/km
Z=(R+jXL) x 150 =3.6+j 36.3 Ω , Y=j2πf CT.L x 150 =j 6.16x10-4 S
A=D=1+(YZ/2)=0.989+j 1.1x10-3 , B=Z=3.6+j 36.3 Ω
C=Y(1+(YZ/4))=-3.414x10 +j 6.125x10-4 S
-7
Vr
Ir= Ir = 0.475- j0.038 A |Ir|= 0.477 A
Zload
Is=CVr+DIr Is = 0.48 + j0.096 A |Is|=0.49 A
3.2.2 Calculation procedure for line length 150 km and Rload=350 ohm.
3.2.3 Calculation procedure for line length 150 km and Rload=300 ohm.
3.3 Questions.
• Calculate the shunt branches currents for line length 150 km.
• Repeat the calculations for line length 150 km using short model
equations, comment.
• Explain the effect of the variation of resistive load on your results,
support your answer with graphs.
Table 6. Calculated and measured values for Cload=2 µf and Rload=350 ohm.
Table 7: Calculated and measured values for Lload=3.2H and Rload=350 ohm.
7.3 Questions.
8.2 Calculation procedure with Lload=3.2H, Rload=350 ohm and Cload=2 µf.
Table 8: Calculated and measured values for Lload=3.2H, Rload=350 ohm and Cload=2 µf.
8.3 Questions.