Kode Trouble Konica Minolta

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 17

Konica-Minolta bizhub 364e

Code trouble
 Code: C0002
 Description:Paper feed communication error
When the printer control board (PRCB) is receiving data, a communication error is
detected.
 Remedy:1 Turn OFF the main power switch, disconnect and then connect the power
cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main
power switch. 2 Rewrite the firmware. 3 Replace PRCB.

 Code: C0106
 Description:Tray 3/LCT paper feed motor turning at abnormal timing
• The motor lock signal remains HIGH for a predetermined continuous period of time
while the motor remains stationary. • The motor lock signal remains LOW for a
predetermined continuous period of time while the motor remains stationary.
 Remedy:When PC-110 or PC-210 is installed: 1 Check the connector between M111-
PCCB CN5 for proper connection and correct as necessary. 2 Check the connector of
M111 for proper drive coupling and correct as necessary. 3 M111 operation check
PCCB CN5-5 (CW/CCW) PC-110/PC-210 4-C. 4 Replace M111. 5 Replace PCCB.
When PC-410 is installed: 1 Check the connector between M131-PCCB CN5 for proper
connection and correct as necessary. 2 Check the connector of M131 for proper drive
coupling and correct as necessary. 3 M131 operation check PCCB CN5-5 (CW/CCW)
PC-410 5-J 4 Replace M131. 5 Replace PCCB.

 Code: C0107
 Description:Tray 3/LCT vertical transport motor turning at abnormal timing
• The motor lock signal remains HIGH for a predetermined continuous period of time
while the motor remains stationary. • The motor lock signal remains LOW for a
predetermined continuous period of time while the motor remains stationary.
 Remedy:When PC-110 or PC-210 is installed: 1 Check the connector between M112-
PCCB CN5 for proper connection and correct as necessary. 2 Check the connector of
M112 for proper drive coupling and correct as necessary. 3 M112 operation check
PCCB CN5-13 (CW/CCW) PC-110/PC-210 3 to 4-C. 4 Replace M112. 5 Replace
PCCB.
When PC-410 is installed: 1 Check the connector between M132-PCCB CN5 for proper
connection and correct as necessary. 2 Check the connector of M132 for proper drive
coupling and correct as necessary. 3 M132 operation check PCCB CN5-13 (CW/CCW)
PC-410 4-J. 4 Replace M132. 5 Replace PCCB.

 Code: C0108
 Description:Tray 4 paper feed motor turning at abnormal timing
<When PC-210 is installed> • The motor lock signal remains HIGH for a predetermined
continuous period of time while the motor remains stationary. • The motor lock signal
remains LOW for a predetermined continuous period of time while the motor remains
stationary.
 Remedy:1 Check the connector between M121-PCCB CN9 for proper connection and
correct as necessary. 2 Check the connector of M121 for proper drive coupling and
correct as necessary. 3 M121 operation check PCCB CN9-5 (CW/CCW) PC-210 6-K. 4
Replace M121. 5 Replace PCCB

 Code: C0109
 Description:Tray 4 vertical transport motor turning at abnormal timing
<When PC-210 is installed> • The motor lock signal remains HIGH for a predetermined
continuous period of time while the motor remains stationary. • The motor lock signal
remains LOW for a predetermined continuous period of time while the motor remains
stationary.
 Remedy:1 Check the connector between M122-PCCB CN9 for proper connection and
correct as necessary. 2 Check the connector of M122 for proper drive coupling and
correct as necessary. 3 M122 operation check PCCB CN9-13 (CW/CCW) PC-210 6-K.
4 Replace M122. 5 Replace PCCB.

 Code: C0202
 Description:Tray 1 feeder up/down abnormality
The tray 1 upper limit sensor (PS22) is not blocked even after the lapse of a given
period of time after the lifting motion has been started.
 Remedy:1 Check the connector between M12-PRCB CN25 for proper connection and
correct as necessary. 2 Check the connector of M12 for proper drive coupling and
correct as necessary. 3 Check the connector between PS25-relay CN30- PRCB CN26
for proper connection and correct as necessary. 4 PS25 I/O check, sensor check PRCB
CN26-3 (ON). 5 M12 operation check PRCB CN25-5 (REM). 6 Replace M12. 7 PRCB
ICP5 conduction check. 8 Replace PRCB.

 Code: C0204
 Description:Tray 2 feeder up/down abnormality
The tray 2 upper limit sensor (PS22) is not blocked even after the lapse of a given
period of time after the lifting motion has been started.
 Remedy:1 Check the connector between M13-PRCB CN20 for proper connection and
correct as necessary. 2 Check the connector of M13 for proper drive coupling and
correct as necessary. 3 Check the connector between PS22-relay CN40- PRCB CN19
for proper connection and correct as necessary. 4 PS22 I/O check, sensor check PRCB
CN19-9 (ON). 5 M13 operation check PRCB CN20-5 (REM). 6 Replace M13. 7 PRCB
ICP4 conduction check. 8 Replace PRCB.
 Code: C0206
 Description:Tray 3 lift-up failure
The tray 3 upper limit sensor (PS116) is not blocked even after the set period of time
has elapsed after the paper lift-up operation for the drawer began.
 Remedy:1 Check the connector between M113-PCCB CN6 for proper connection and
correct as necessary. 2 Check the connector of M113 for proper drive coupling and
correct as necessary. 3 Check the connector between PS116-relay CN24- PCCB CN4
for proper connection and correct as necessary. 4 PS116 I/O check, sensor check PCCB
CN4-3 (ON). 5 M113 operation check PCCB CN6-8 to 9. 6 Replace M113. 7 Replace
PCCB. 8 Replace MFPB.

 Code: C0208
 Description:Tray 4 lift-up failure
The tray 4 upper limit sensor (PS126) is not blocked even after the set period of time
has elapsed after the paper lift-up operation for the drawer began.
 Remedy:1 Check the connector between M123-PCCB CN8 for proper connection and
correct as necessary. 2 Check the connector of M123 for proper drive coupling and
correct as necessary. 3 Check the connector between PS126-relay CN47- PCCB CN7
for proper connection and correct as necessary. 4 PS126 I/O check, sensor check PCCB
CN7-3. 5 M123 operation check PCCB CN8-8 to 9. 6 Replace M123. 7 Replace PCCB.
8 Replace MFPB.

 Code: C0210
 Description:LCT lift failure
• The main tray upper limit sensor (PS136) is not blocked even after the set period of
time has elapsed after the paper lift-up operation for the drawer began. • The shifter stop
/ lower limit position sensor (PS138) is not unblocked even after the set period of time
has elapsed after the paper lift-up operation for the drawer began. • The main tray upper
limit sensor (PS136) is not blocked even after the set period of time has elapsed after
the paper lift-up operating. • The main tray upper limit sensor (PS136) is not unblocked
even after the set period of time has elapsed after the paper lift-down operation began. •
The shifter stop / lower limit position sensor (PS138) is not blocked even after the set
period of time has elapsed after the paper lift-down operation began.
 Remedy:1 Check the connector between M134-PCCB CN10 for proper connection and
correct as necessary. 2 Check the connector of M134 for proper drive coupling and
correct as necessary. 3 Check the connector between PS136-relay CN1- PCCB CN4 for
proper connection and correct as necessary. 4 Check the connector between PS138-
relay CN16- PCCB CN14 for proper connection and correct as necessary. 5 PS136 I/O
check, sensor check PCCB CN4-3 (ON) PC-410 8-J. 6 PS138 I/O check, sensor check
PCCB CN14-6 (ON) PC-410 4-J. 7 M134 operation check PCCB CN10-1 to 2 PC-410
6-J. 8 Replace M134. 9 PCCB IC2 conduction check. 10 Replace PCCB.
 Code: C0211
 Description:Manual feed up/down abnormality
• Paper does not unblock the bypass lift-up position sensor (PS26) even after the
transport motor (M1) rotates for a given period of time after the position is switched
from stand by position at lift-up plate to the feed position. • The bypass lift-up position
sensor (PS26) is not blocked even after the transport motor (M1) rotates for a given
period of time after the position is switched from stand by position at lift-up plate to the
feed position.
 Remedy:1 Check the connector between M1-PRCB CN31 for proper connection and
correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct
as necessary. 3 Check the connector between PS26-relay CN19- PRCB CN27 for
proper connection and correct as necessary. 4 Check the connector between SD1-relay
CN21-relay CN19-PRCB CN27 for proper connection and correct as necessary. 5 PS26
I/O check, sensor check PRCB CN27-13 (ON) 4-C. 6 SD1 operation check PRCB
CN27-10 (ON) 4-C 7. M1 operation check PRCB CN31-2 (REM) PRCB CN31-5
(LOCK). 8 Replace M1. 9 PRCB ICP5 conduction check. 10 Replace PRCB.
 Code: C0214
 Description:LCT shift failure
• The shifter stop / lower limit position sensor (PS138) is not blocked even after the set
period of time has elapsed after the shift operation began (shift to the right). • The
shifter home sensor (PS139) is not unblocked even after the set period of time has
elapsed after the shift operation began (shift to the right). • The shifter stop / lower limit
position sensor (PS138) is not unblocked even after the set period of time has elapsed
after the return operation began (shift to the left). • The shifter home sensor (PS139) is
not blocked even after the set period of time has elapsed after the return operation began
(shift to the left).
 Remedy:1 Check the connector between M133-PCCB CN10 for proper connection and
correct as necessary. 2 Check the connector of M133 for proper drive coupling and
correct as necessary. 3 Check the connector between PS138-relay CN16- PCCB CN14
for proper connection and correct as necessary. 4 Check the connector between PS139-
relay CN16- PCCB CN14for proper connection and correct as necessary. 5 PS138 I/O
check, sensor check PCCB CN14-6 (ON) PC-410 4-J. 6 PS139 I/O check, sensor check
PCCB CN14-3 (ON) PC-410 4-J. 7 M133 operation check PCCB CN10-3 to 4 PC-410
6-J. 8 Replace M133. 9 PCCB IC2 conduction check. 10 Replace PCCB.

 Code: C1004
 Description:FNS communication error
<When FS-533 or FS-534 is installed> When the FS control board (FSCB) is receiving
data, a communication error is detected.
<When JS-506 is installed> When the JS control board (JSCB) is receiving data, a
communication error is detectedce M121.
 Remedy:1 Turn OFF the main power switch, disconnect and then connect the power
cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main
power switch. 2 Rewrite the firmware. 3 Replace FSCB (FS-533/FS-534) When JS-506
is installed Step Action Control signal Location of electrical components 1 Turn OFF
the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or
more after connect the power cord, and turn ON the main power switch. 2 Rewrite the
firmware. 3 Replace JSCB.

 Code: C1081
 Description:SD communication error
<When FS-534+SD-511 is installed> When a communication error is detected between
the FS control board (FSCB) and the SD control board (SDDB).
 Remedy:1 Turn OFF the main power switch, disconnect and then connect the power
cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main
power switch. 2 Rewrite the firmware. 3 Replace SDDB. 4 Replace FSCB.

 Code: C1102
 Description:Main tray up/down motor’s drive malfunction
<When FS-533 is installed> • While the exit tray is being lifted, the stapler movement
motor (M107) is not unblocked after the set period of time has elapsed after the tray lift
up motor (M109) is turned ON. • While the exit tray is being lowered, the stapler
movement motor (M107) is not blocked after the set period of time has elapsed after the
tray lift up motor (M109) is turned ON
<When FS-534 is installed> • While the exit tray is being lifted, the main tray upper
position sensor (PS26/PS27) is not blocked and the main tray upper position detect
switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by
the set number of times. • While the exit tray is being lowered, the main tray full
detection sensor (PS29) is not blocked after the set period of time has elapsed after the
main tray up/down motor (M11) is turned ON.c
 Remedy:When FS-533 is installed: 1 Check the connector between M109-FSCB
CN108 for proper connection and correct as necessary. 2 Check the connector of M109
for proper drive coupling and correct as necessary. 3 Check the connector between
PS107-FSCB CN110 for proper connection and correct as necessary. 4 PS107 I/O
check, sensor check FSCB CN110 FS-533 7-D to E 5 M109 operation check FSCB
CN108 FS-533 10-E. 6 Replace M109. 7 FSCB CP109 conduction check. 8 Replace
FSCB.
When FS-534 is installed: 1 Check the motor and sensor connectors for proper
connection, and correct as necessary. 2 Check the connector of M11 for proper drive
coupling, and correct as necessary. 3 PS26 I/O check, sensor check FSCB J14<A>-5
(ON) FS-534 2-C. 4 PS27 I/O check, sensor check FSCB J14<B>-8 (ON) FS-534 3-C.
5 PS29 I/O check, sensor check FSCB J14<A>-8 (ON) FS-534 4-C. 6 SW2 operation
check. 7 M11 operation check FSCB J9<A>-9 to 10 FS-534 10-C to D. 8 Replace M11.
9 Replace FSCB.

 Code: C1103
 Description:Alignment plate motor/Fr’s malfunction
<When FS-533 is installed> • The alignment plate home sensor/F (PS108) is not
unblocked after the set period of time has elapsed after the plate drive starts from the
home position. • The alignment plate home sensor/F (PS108) is not blocked after the set
period of time has elapsed after the alignment motor/F (M105) is turned ON to return
the plate to the home position.
<When FS-534 is installed> • The alignment plate/F home sensor (PS12) is not
unblocked after the set period of time has elapsed after the plate drive starts from the
home position. • The alignment plate/F home sensor (PS12) is not blocked after the set
period of time has elapsed after the alignment motor/front (M7) is turned ON to return
the plate to the home position. • The alignment plate/F does not reach the specified
position within the set period of time
 Remedy:When FS-533 is installed: 1 Check the connector between M105-FSCB
CN102 for proper connection and correct as necessary. 2 Check the connector of M105
for proper drive coupling and correct as necessary. 3 Check the connector between
PS108-FSCB CN102 for proper connection and correct as necessary. 4 PS108 I/O
check, sensor check FSCB CN102 FS-533 7-J. 5 M105 operation check FSCB CN102
FS-533 7-J. 6 Replace M105. 7 FSCB CP105 conduction check. 8 Replace FSCB.
When FS-534 is installed: 1 Check the connector between M7-FSCB J4 for proper
connection and correct as necessary. 2 Check the connector of M7 for proper drive
coupling, and correct as necessary. 3 Check the connector between PS12-FSCB J4 for
proper connection and correct as necessary. 4 PS12 I/O check, sensor check FSCB
J4<B>-4 (ON) FS-534 13-C. 5 M7 operation check FSCB J4<A>-5 to 8 FS-534 11-C to
D. 6 Replace M7. 7 Replace FSCB.

 Code: C1105
 Description:Bundle eject motor’s drive malfunction
<When FS-534 is installed> • The gripper home position sensor (PS18) does not block
even after the set period of time has elapsed after the gripper position detection sensor
(PS19) unblocked. • The gripper position detection sensor (PS19) does not block even
after the set period of time has elapsed after it unblock • The gripper position detection
sensor (PS19) does not block even after the set period of time has elapsed after the
gripper home position sensor (PS18) unblocked. • The gripper home position sensor
(PS18) does not block even after the set period of time has elapsed after the bundle eject
motor (M10) unblocked. • The gripper home position sensor (PS18) and the gripper
position detection sensor (PS19) are blocked at the same time.
 Remedy:1 Check the motor and sensor connectors for proper connection, and correct as
necessary. 2 Check the connector of M10 for proper drive coupling, and correct as
necessary. 3 PS18 I/O check, sensor check FSCB J13-13 (ON) FS-534 7-C. 4 PS19 I/O
check, sensor check FSCB J12-3 (ON) FS-534 7-C. 5 M10 operation check FSCB J13-1
to 2 FS-534 8-C to D. 6 Replace M10. 7 Replace FSCB.
 Code: C1106
 Description:Stapler movement motor’s malfunction
<When FS-533 is installed> • The stapler home sensor (PS110) is not unblocked after
the laps of given time after it started operating from the home position. • The stapler
home sensor (PS110) is not unblocked after the laps of give time after the stapler
movement motor (M107) turned ON when it returned to the home position.
<When FS-534 is installed> • The stapler home position sensor (Rear) (PS23) is not
blocked or unblocked even after the set period of time has elapsed after the side stapler
movement motor (M13) turned ON. • The stapler does not reach the specified position
within the set period of time. J
 Remedy:When FS-533 is installed: 1 Check the connector between M107-STREYB
CN123 for proper connection, and correct as necessary. 2 Check the connector of M107
for proper drive coupling, and correct as necessary. 3 Check the connector between
PS110-FSCB CN110 for proper connection, and correct as necessary. 4 PS110 I/O
check, sensor check FSCB CN110 FS-533 8-D to E. 5 M107 operation check STREYB
CN123-5 to 8 FS-533 5-L. 6 Replace M107. 7 Replace STREYB. 8 FSCB CP107
conduction check. 9 Replace FSCB.
When FS-534 is installed: 1 Check the connector between M13-relay CN3-FSCB J11
for proper connection, and correct as necessary. 2 Check the connector of M13 for
proper drive coupling, and correct as necessary. 3 Check the connector between PS23-
relay CN3-FSCB J11 for proper connection, and correct as necessary. 4 PS23 I/O
check, sensor check FSCB J11<B>-3 (ON) FS-534 4-C. 5 M13 operation check FSCB
J11<A>-1 to 4 FS-534 4-C to D. 6 Replace M13. 7 Replace FSCB.

 Code: C1109
 Description:Stapler motor’s drive malfunction
<When FS-533 is installed> The stapler home sensor (PS110) is not blocked even after
the set period of time has elapsed after the stapler motor turned ON.
<When FS-534 is installed> • The stapler home position sensor (Rear) (PS23) is not
blocked or unblocked even after the set period of time has elapsed after the stapler
motor (M14) turned ON. • The stapler position sensor (Center) (PS24) is blocked, when
the stapler motor (M14) is running.
 Remedy:When FS-533 is installed: 1 Check the connector between the stapler unit-
STREYB CN122 and CN123 for proper connection and correct as necessary. 2 Check
the connector of the stapler unit for proper drive coupling and correct as necessary. 3
Check the connector between PS110-FSCB CN110 for proper connection and correct as
necessary. 4 PS110 I/O check, sensor check FSCB CN110 FS-533 8-D to E. 5 Replace
the stapler unit. 6 Replace STREYB. 7 Replace FSCB.
When FS-534 is installed: 1 Check the connector between the stapler unit-relay CN4-
FSCB J11 for proper connection and correct as necessary. 2 Check the connector of the
stapler unit for proper drive coupling, and correct as necessary. 3 Check the connector
between PS23-relay CN3-FSCB J11 for proper connection and correct as necessary. 4
Check the connector between PS24-relay CN3-FSCB J11 for proper connection and
correct as necessary. 5 PS23 I/O check, sensor check FSCB J11<B>-3 (ON) FS-534 4-
C. 6 PS24 I/O check, sensor check FSCB J11<B>-6 (ON) FS-534 4 to 5-C. 7 Replace
the stapler unit. 8 Replace FSCB.

 Code: C1112
 Description:Stapler motor’s malfunction
<When FS-534+SD-511 is installed> • The stapler home sensor is not turned ON even
after the set period of time has elapsed while the stapler motor is energized. • The
stapler home sensor is not turned OFF even after the set period of time has elapsed after
the stapler home sensor is turned ON.
 Remedy:1 Check the connector between the staple unit-SDDB J4 for proper connection
and correct as necessary. 2 Check the connector of the staple unit for proper drive
coupling and correct as necessary. 3 Replace the staple unit. 4 Replace SDDB. 5
Replace FSCB.

 Code: C1113
 Description:Center-staple lead edge stopper motor malfunction
<When FS-534+SD-511 is installed> The stopper home sensor (PS6) is not blocked or
unblocked even after the set period of time has elapsed after the stopper drive motor
(M4) is turned ON.
 Remedy:1 Check the connector between M4-SDDB J10 for proper connection and
correct as necessary. 2 Check the connector of M4 for proper drive coupling, and
correct as necessary. 3 Check the connector between PS6-SDDB J10 for proper
connection, and correct as necessary. 4 PS6 I/O check, sensor check SDDB J10-5 (ON)
SD-511 2-G. 5 M4 operation check SDDB J10-6 to 9 SD-511 1 to 2-F to G. 6 Replace
M4. 7 Replace SDDB. 8 Replace FSCB.
 Code: C1114
 Description:Center-staple front adjust drive motor malfunction
<When FS-534+SD-511 is installed> The alignment home sensor (PS4) is not blocked
or unblocked even after the set period of time has elapsed after the alignment motor
(M3) is turned ON.
 Remedy:1 Check the connector between M3-relay CN10-SDDB J7 for proper
connection and correct as necessary. 2 Check the connector of M3 for proper drive
coupling, and correct as necessary. 3 Check the connector between PS4-relay CN10-
SDDB J7 for proper connection, and correct as necessary. 4 PS4 I/O check, sensor
check SDDB J7-6 (ON) SD-511 6-F. 5 M3 operation check SDDB J7 7 to 10 SD-511 5-
F to G. 6 Replace M3. 7 Replace SDDB. 8 Replace FSCB.

 Code: C1115
 Description:Center-staple knife drive motor malfunction
<When FS-534+SD-511 is installed> The center fold knife home sensor (PS8) is not
blocked or unblocked even after the set period of time has elapsed after the center fold
knife motor (M9) is turned ON.
 Remedy:1 Check the connector between M9-SDDB J11 for proper connection and
correct as necessary. 2 Check the connector of M9 for proper drive coupling, and
correct as necessary. 3 Check the connector between PS8-relay CN10-SDDB J7 for
proper connection, and correct as necessary. 4 PS8 I/O check, sensor check SDDB J7-3
(ON) SD-511 6-G. 5 M9 operation check SDDB J11 11 to 20 SD-511 1 to 2-B. 6
Replace M9. 7 Replace SDDB. 8 Replace FSCB.

 Code: C1132
 Description:Punch drive motor’s malfunction
<When FS-533+PK-519 is installed> • The puncher drive cam sensor (PS203) or
puncher home sensor (PS204) is not blocked or unblocked even after the set period of
time has elapsed while the punch motor (M201) is energized. • The punch motor sensor
(PS202) does not turn ON after the punch motor (M201) stopped. • The holes with other
marketing area is set in [Service Mode] - [Finisher] - [Punch Option Setting]
<When FS-534+PK-520 is installed> The punch home sensor (PS1) is not blocked or
unblocked even after the set period of time has elapsed while the punch drive motor
(M1) is energized.
 Remedy:When FS-533+PK-519 is installed: 1 Check the number of the holes in
[Service Mode] - [Finisher] - [Punch Option Setting]. 2 Check the connector between
M201-PKCB CN203 for proper connection, and correct as necessary. 3 Check the
connector of M201 for proper drive coupling, and correct as necessary. 4 Check the
connector between PS202-PKCB CN204 for proper connection, and correct as
necessary. 5 Check the connector between PS203-PKCB CN204. for proper connection,
and correct as necessary. 6 Check the connector between PS204-PKCB CN204 for
proper connection, and correct as necessary. 7 PS202 I/O check, sensor check PKCB
CN204 FS-533 (PK-519) 5-C. 8 PS203 I/O check, sensor check PKCB CN204 FS-533
(PK-519) 6-C. 9 PS204 I/O check, sensor check PKCB CN204 FS-533 (PK-519) 6-C.
10 M201 operation check PKCB CN203-1 to 2 FS-533 (PK-519) 4-C. 11 Replace
M201. 12 PKCB F201 conduction check. 13 Replace PKCB. 14 Replace FSCB.
When FS-534+PK-520 is installed: 1 Check the connector between M1-relay CN351-
FSCB J7 for proper connection, and correct as necessary. 2 Check the connector of M1
for proper drive coupling, and correct as necessary. 3 Check the connector between
PS1-FSCB J7 for proper connection, and correct as necessary. 4 PS1 I/O check, sensor
check FSCB J7-5 (ON) FS-534 (PK-520) 7-K. 5 M1 operation check FSCB J7 7 to 8
FS-534 (PK-520) 7-K 6 Replace M1. 7 Replace FSCB.

 Code: C1140
 Description:Alignment plate motor/Rr’s malfunction
<When FS-533 is installed> • The alignment plate home sensor/R (PS109) is not
unblocked after the set period of time has elapsed after the plate drive starts from the
home position. • The alignment plate home sensor/R (PS109) is not blocked after the set
period of time has elapsed when the plate returns to the home position.
<When FS-534 is installed> The alignment plate/R home sensor (PS13) is not blocked
or unblocked even after the set period of time has elapsed while the alignment motor/Rr
(M8) is energized.
 Remedy:When FS-533 is installed: 1 Check the connector between M106-FSCB
CN102 for proper connection and correct as necessary. 2 Check the connector of M106
for proper drive coupling and correct as necessary. 3 Check the connector between
PS109-relay CN106- FSCB CN102 for proper connection and correct as necessary. 4
PS109 I/O check, sensor check FSCB CN102 FS-533 7-J 5 M106 operation check
FSCB CN102 FS-533 8-J 6 Replace M106. 7 FSCB CP105 conduction check. 8
Replace FSCB.
When FS-534 is installed: 1 Check the connector between M8-FSCB J12 for proper
connection, and correct as necessary. 2 Check the connector of M8 for proper drive
coupling, and correct as necessary. 3 Check the connector between PS13-FSCB J9 for
proper connection, and correct as necessary. 4 PS13 I/O check, sensor check FSCB
J9<B>-9 (ON) FS-534 9-C. 5 M8 operation check FSCB J12-13 to 16 FS-534 5~6-C to
D 6 Replace M8. 7 Replace FSCB.
 Code: C1141
 Description:Paddle motor’s drive malfunction
<When FS-534 is installed> The upper paddle homeposition detection sensor (PS14) is
not blocked or unblocked even after the set period of time has elapsed while the FNS
paddle motor (M5) is turning.
 Remedy:1 Check the connector between M5-FSCB J4 for proper connection, and
correct as necessary. 2 Check the connector of M5 for proper drive coupling, and
correct as necessary. 3 Check the connector between PS14-FSCB J4 for proper
connection, and correct as necessary. 4 PS14 I/O check, sensor check FSCB J4<B>-7
(ON) FS-534 13-C. 5 M5 operation check FSCB J4<A>-5 to 8 FS-534 12-C to D. 6
Replace M5. 7 Replace FSCB.

 Code: C1144
 Description:Pre-eject drive motor’s malfunction
<When FS-534 is installed> • The pre-eject home sensor (PS21) is not blocked or
unblocked even after the set period of time has elapsed after the pre-eject drive motor
(M9) is turned ON. • The pre-eject away sensor (PS22) is not blocked or unblocked
even after the set period of time has elapsed after the pre-eject drive motor (M9) is
turned ON.k
 Remedy:1 Check the connector between M9-relay CN7<A>- FSCB J13 for proper
connection, and correct as necessary. 2 Check the connector of M9 for proper drive
coupling, and correct as necessary. 3 Check the connector between PS21-relay CN8-
relay CN7<B>-FSCB J12 for proper connection, and correct as necessary. 4 Check the
connector between PS22-relay CN8-relay CN7<B>-FSCB J12 for proper connection,
and correct as necessary. 5 PS21 I/O check, sensor check FSCB J12-6 (ON) FS-534 6-
C. 6 PS22 I/O check, sensor check FSCB J12-9 (ON) FS-534 6-C. 7 M9 operation
check FSCB J13-3 to 4 FS-534 8-C to D. 8 Replace M9. 9 Replace FSCB.

 Code: C1145
 Description:Trailing edge stopper motor’s malfunction
<When FS-534 is installed> The trailing edge stopper home position detection sensor
(PS20) is not blocked or unblocked even after the set period of time has elapsed after
the trailing edge stopper motor (M6) is turned ON.
 Remedy:1 Check the connector between M6-FSCB J5 for proper connection, and
correct as necessary. 2 Check the connector of M6 for proper drive coupling, and
correct as necessary. 3 Check the connector between PS20-relay CN22-FSCB J5 for
proper connection, and correct as necessary. 4 PS20 I/O check, sensor check FSCB J5-9
(ON) FS-534 9-K. 5 M6 operation check FSCB J5-13 to 16 FS-534 9-K. 6 Replace M6.
7 Replace FSCB.

 Code: C1156
 Description:Center-staple paddle roller motor malfunction (trailing edge)
<When FS-534+SD-511 is installed> The paddle home sensor (PS5) is not blocked or
unblocked even after the set period of time has elapsed while the SD paddle motor (M7)
is energized.
 Remedy:1 Check the connector between M7-SDDB J8 for proper connection and
correct as necessary. 2 Check the connector of M7 for proper drive coupling, and
correct as necessary. 3 Check the connector between PS5-SDDB J8 for proper
connection and correct as necessary. - - 5 PS5 I/O check, sensor check SDDB J8-3
(ON) SD-511 3 to 4-G. 7 M7 operation check SDDB J8 4 to 7 SD-511 3-F to G. 8
Replace M7. 9 Replace SDDB. 10 Replace FSCB.

You might also like