Group 9 Quiz and Answer Key Plumbing Ventilation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Plumbing Ventilation end of the vent pipe connects to the

waste pipe on the downstream side of


Group 9 Quiz the highest fixture of the group and the
upper end connects to branch vent,
vent stack, stack vent or extends to
open air independently.
a. Trap Vents
1. __________ is a type of group venting b. Circuit Vents
where one vent protects two fixture c. Stack Vents
traps. d. Yoke Vents
a. Primary Vents
b. Dual Venting
c. Bilateral Venting
d. Triad Venting
5. It is an arrangement of group venting
when fixture traps are vented through
2. According to Section 905.1 of the the soil stack which terminates into a
Revised National Plumbing Code of header or open air and no additional
the Philippines, “All horizontal vent venting is required.
and branch vent pipes shall be free a. Trap Vents
from drops or sags and each such vent b. Circuit Vents
shall be graded and connected to drip c. Stack Vents
back by gravity to the _________ it d. Yoke Vents
serves.”
a. Drainage Pipe
b. Sewage Pipe 6. The installation of this depends upon
c. Soil Pipe the good judgement of the plumber to
d. Oil Pipe wherever back pressure is most likely
to occur.
a. Looped Vents
3. "Every drainage pipe that has a size of b. Wet Vents
3" or less, and every fixture drain shall c. Stack Vents
have a ____________in the direction d. Relief Vents
of flow of at least______."
a. Upward Slope, 1:100
b. Downward Slope, 1:25 7. How do plumbing vents protect trap
c. Downward Slope, 1:50 seals?
d. Upward Slope, 1:75 a. By balancing the air pressure
inside the drainage system
b. By blocking the air pressure
4. It means a vent pipe that functions for inside the drainage system
two or more traps connecting to a c. By ventilating the the solid and
horizontal branch where the lowest waste pipes
d. By reducing the vent piping
required for a given installation

8. It is the standing water inside a trap.


a. Siphonage
b. Drainage System
c. Sewer Gas
d. Trap Seal

9. "No vent pipe shall be so arranged


that it will serve as a bypass in the
event of an obstruction in the
drainage pipe."
a. True
b. False
c. Both A and B
d. Neither A nor B

10. “Each soil or waste stack which


extends 10 or more stories above the
building drain shall be served by a
parallel vent stack which will extend
undiminished in size from its upper
terminal at the roof and connect to the
soil or waste stack at ground level.”
What section part of the Chapter 9 of
the National Plumbing Code does the
statement belongs to?
a. Section 906.4
b. Section 905.3
c. Section 908.4
d. Section 907.1
Answer Key

1. B. Dual Venting
2. A. Drainage Pipe
3. C. Downward Slope, 1:50
4. B. Circuit Vents
5. C. Stack Vents
6. D. Relief Vents
7. A. By balancing the air
pressure inside the drainage
system.
8. D. Trap Seal
9. A. True
10. D. Section 907.1