The new cameras have some differences in term of the
smart detection functions which newly have the max
and min target size functions.
This article takes DS-2CD2635FWD-IS as an example,
introduce how to set this function.
Steps:Steps: Steps:Steps:
(1) Click Configuration>Event>Smart Event, Enter the
Line Crossing Detection setting interface.
(2) Check the Enable checkbox of Line Crossing
Detection to enable the function.xxxx
(3) Click the Draw Area button and draw a virtual line of
where you wish the alert to take place on the camera
view.
(4) Set the Max. Size and Min Size for a valid target.
Click Max. Size button and draw Rectangle area. click
Min. Size button and draw Rectangle Area.
NOTE:
2: Intrusion Detection
Steps:
(4) Set the Max. and Min Size for valid targets.
Targets smaller or larger than the valid target size are
not able to trigger detection.
Note:
Threshold: Range [0-10]s. The Threshold for the time of
the object loitering in the region. If you set the calue as
0, alarm is triggered immediately after the object
enteres the region.