General Part
Famille de produit Cheville à scellement avec tige filetée, fers à béton, douille
Product family taraudée et cheville de traction Hilti HZA pour ancrage dans le
béton fissuré.
Bonded fastener with threaded rods, rebar, internal sleeve
and Hilti tension anchor HZA for use in concrete.
Base de l‘ETE ETAG 001, Version April 2013, utilisée en tant que EAD
Basis of ETA ETAG 001, Edition April 2013 used as EAD
Specific Part
Charles Baloche
Technical Director
1
Official Journal of the European Communities L 254 of 08.10.1996
European technical assessment ETA-1 6 / 0 1 4 3 Page 4 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Installed condition
Figure A1:
Threaded rod, HIT-V-…
Marking of the
embedment depth
d0
h0 = hef tfix
h
Figure A2:
Internally threaded sleeve HIS-(R)N
hs
df
d0
h0 = hef tfix
Figure A3:
Reinforcing bar (rebar)
Marking of the embedment depth
d0
h0 = hef
h
Annex A1
Product
Installed condition
European technical assessment ETA-1 6 / 0 1 4 3 Page 5 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Marking:
HILTI HIT
Production date
Production time and line
Expiry date mm/yyyy
Steel elements
Hilti Tension Anchor HZA: M12 to M27 and HZA-R: M12 to M24
Annex A2
Product
Injection mortar / Static mixer / Steel elements.
European technical assessment ETA-1 6 / 0 1 4 3 Page 6 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Designation Material
Reinforcing bars (rebars)
Rebar
Bars and de-coiled rods class B or C
EN 1992-1-1:2004
with fyk and k according to NDP or NCL of EN 1992-1-1/NA:2013
and AC:2010,
fuk = ftk = k ∙ fyk
Annex C
Metal parts made of zinc coated steel
Strength class 5.8, fuk = 500 N/mm², fyk = 400 N/mm²
Threaded rod,
Elongation at fracture (l0 = 5d) > 8% ductile
HIT-V-5.8(F)
Electroplated zinc coated 5 m, (F) hot dip galvanized 45 m
Strength class 8.8, fuk = 800 N/mm², fyk = 640 N/mm²
Threaded rod,
Elongation at fracture (l0 = 5d) > 12% ductile
HIT-V-8.8(F)
Electroplated zinc coated 5 m, (F) hot dip galvanized 45 m
Hilti tension anchor Round steel with threaded part: electroplated zinc coated 5 m
HZA Rebar: Bars class B according to NDP or NCL of EN 1992-1-1/NA:2013
Internally threaded
Electroplated zinc coated 5 m
sleeve HIS-N
Washer Electroplated zinc coated 5 m, hot dip galvanized 45 m
Strength class of nut adapted to strength class of threaded rod.
Nut
Electroplated zinc coated 5 m, hot dip galvanized 45 m
Metal parts made of stainless steel
For ≤ M24: strength class 70, fuk = 700 N/mm², fyk = 450 N/mm²
Threaded rod, For > M24: strength class 50, fuk = 500 N/mm², fyk = 210 N/mm²
HIT-V-R Elongation at fracture (l0 = 5d) > 8% ductile
Stainless steel 1.4401, 1.4404, 1.4578, 1.4571, 1.4439, 1.4362 EN 10088-1:2014
Round steel with threaded part:
Hilti tension anchor
Stainless steel 1.4404, 1.4362, 1.4571 EN 10088-1:2014
HZA-R
Rebar: Bars class B according to NDP or NCL of EN 1992-1-1/NA:2013
Internally threaded
Stainless steel 1.4401, 1.4571 EN 10088-1:2014
sleeve HIS-RN
Washer Stainless steel 1.4401, 1.4404, 1.4578, 1.4571, 1.4439, 1.4362 EN 10088-1:2014
Strength class of nut adapted to strength class of threaded rod.
Nut
Stainless steel 1.4401, 1.4404, 1.4578, 1.4571, 1.4439, 1.4362 EN 10088-1:2014
Metal parts made of high corrosion resistant steel
For ≤ M20: fuk = 800 N/mm², fyk = 640 N/mm²
Threaded rod, For > M20: fuk = 700 N/mm², fyk = 400 N/mm²
HIT-V-HCR Elongation at fracture (l0 = 5d) > 8% ductile
High corrosion resistant steel 1.4529, 1.4565 EN 10088-1:2014
Washer High corrosion resistant steel 1.4529, 1.4565 EN 10088-1:2014
Strength class of nut adapted to strength class of threaded rod.
Nut
High corrosion resistant steel 1.4529, 1.4565 EN 10088-1:2014
Annex A3
Product description
Materials.
European technical assessment ETA-1 6 / 0 1 4 3 Page 7 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Base material:
Reinforced or unreinforced normal weight concrete according to EN 206:2013.
Strength classes C20/25 to C50/60 according to EN 206:2013.
Cracked and non-cracked concrete. (diamond coring: non-cracked concrete only)
Flooded holes for non cracked concrete only
Design:
Anchorages are designed under the responsibility of an engineer experienced in anchorages and
concrete work.
Verifiable calculation notes and drawings are prepared taking account of the loads to be anchored. The
position of the anchor is indicated on the design drawings (e. g. position of the anchor relative to
reinforcement or to supports, etc.).
Anchorages under static or quasi-static loading are designed in accordance with:
“EOTA Technical Report TR 029, 09/2010”
“CEN/TS 1992-4:2009”
Anchorages under seismic actions (cracked concrete) are designed in accordance with:
“EOTA Technical Report TR 045, 02/2013”
Anchorages shall be positioned outside of critical regions (e.g. plastic hinges) of the concrete structure.
Fastenings in stand-off installation or with a grout layer under seismic action are not covered in this
European technical assessment (ETA).
Annex B1
Intended use
Specifications.
European technical assessment ETA-1 6 / 0 1 4 3 Page 8 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Installation:
Use category:
dry or wet concrete (not in flooded holes): for all drilling techniques
dry or wet concrete or installation in flooded holes: for hammer drilling only, for non-cracked
concrete only
Drilling technique:
hammer drilling,
hammer drilling with Hilti hollow drill bit TE-CD, TE-YD,
diamond coring,
diamond coring followed by roughening with Hilti Roughening tool TE-YRT.
Overhead installation is admissible.
Anchor installation carried out by appropriately qualified personnel and under the supervision of the
person responsible for technical matters of the site.
Annex B2
Intended use
Specifications.
European technical assessment ETA-1 6 / 0 1 4 3 Page 9 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
HIT-V-…
l
d
Marking:
5.8 - l = HIT-V-5.8 M…x l
5.8F - l = HIT-V-5.8F M…x l
8.8 - l = HIT-V-8.8 M…x l
8.8F - l = HIT-V-8.8F M…x l
R-l = HIT-V-R M ...x l
HCR - l = HIT-V-HCR M ...x l
Annex B3
Intended Use
Installation parameters.
European technical assessment ETA-1 6 / 0 1 4 3 Page 10 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
hef
HILTI
HIS...
d
Marking:
Identifying mark - HILTI and
embossing “HIS-N” (for zinc coated steel)
embossing “HIS-RN” (for stainless steel)
Annex B4
Intended Use
Installation parameters.
European technical assessment ETA-1 6 / 0 1 4 3 Page 11 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Marking:
embossing “HZA-R” M .. / tfix
HZA-R M
hef le tfix
hnom
Annex B5
Intended Use
Installation parameters.
European technical assessment ETA-1 6 / 0 1 4 3 Page 12 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Annex B6
Intended Use.
Installation parameters.
European technical assessment ETA-1 6 / 0 1 4 3 Page 13 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Diameter [mm] 10 12 14 16 20 25 28 30 32
60 70 75 80 90 100 112 120 128
Effective embedment hef =
[mm] to to to to to to to to to
depth and drill hole depth h0
200 240 280 320 400 500 560 600 640
Nominal diameter of
d0 [mm] 121) 141) 141) 161) 18 20 25 32 35 37 40
drill bit
Annex B7
Intended Use.
Installation parameters
European technical assessment ETA-1 6 / 0 1 4 3 Page 14 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Annex B8
Intended Use.
Maximum working time and minimum curing time
European technical assessment ETA-1 6 / 0 1 4 3 Page 15 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Size Name Size Size d0 [mm] d0 [mm] d0 [mm] d0 [mm] HIT-RB HIT-SZ
M8 - - 10 - 10 - 10 -
M10 - 10 - 12 - 12 - 12 12
M12 M8 10, 12 - 14 14 14 - 14 14
- - 12 M12 16 16 16 - 16 16
M16 M10 14 - 18 18 18 18 18 18
- - 16 M16 20 20 20 20 20 20
M20 M12 - - 22 22 22 22 22 22
- - 20 M20 25 25 25 25 25 25
M24 M16 - - 28 28 28 28 28 28
M27 - - - 30 - 30 30 30 30
- M20 25 M24 32 32 32 32 32 32
M30 - 28 M27 35 35 35 35 35 35
- - 30 - 37 - 37 - 37 37
40 - - - 40 40
- - 32 -
- - 42 - 42 42
Cleaning alternatives
Annex B9
Intended use.
Cleaning and setting tools
European technical assessment ETA-1 6 / 0 1 4 3 Page 16 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table B8: Parameters for use of the Hilti Roughening tool TE-YRT
d0 [mm]
d0 [mm] size troughen [sec] = hef [mm] / 10
nominal measured
18 17,9 to 18,2 18 18
hef [mm] troughen [sec]
20 19,9 to 20,2 20 20
0 to 100 10
22 21,9 to 22,2 22 22
101 to 200 20
25 24,9 to 25,2 25 25
201 to 300 30
28 27,9 to 28,2 28 28
301 to 400 40
30 29,9 to 30,2 30 30
401 to 500 50
32 31,9 to 32,2 32 32
501 to 600 60
35 34,9 to 35,2 35 35
TE-YRT
RTG
Annex B10
Intended use.
Parameters for use of the Hilti Roughening tool TE-YRT
European technical assessment ETA-1 6 / 0 1 4 3 Page 17 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Installation instruction
Hole drilling
a) Hammer drilling: For dry or wet concrete and installation in flooded holes (no sea water).
Drill hole to the required embedment depth with a hammer drill set in rotation-hammer
mode using an appropriately sized carbide drill bit.
b) Hammer drilling with Hilti hollow drill bit: For dry and wet concrete only.
Drill hole to the required embedment depth with an appropriately sized Hilti TE-CD or
TE-YD hollow drill bit with Hilti vacuum attachment. This drilling system removes the
dust and cleans the drill hole during drilling when used in accordance with the user’s
manual. After drilling is completed, proceed to the “injection preparation” step in the
installation instruction.
Diamond coring is permissible when suitable diamond core drilling machines and the
corresponding core bits are used.
d) Diamond coring followed by roughening with Hilti Roughening tool: For dry and wet concrete only.
Diamond coring is permissible when suitable diamond core drilling machines and the
corresponding core bits are used.
For the use in combination with Hilti roughening tool TE-YRT see parameters in Table
B8.
Before roughening the borehole needs to be dry. Check usability of the roughening tool
with the wear gauge RTG.
Roughen the borehole over the whole length to the required hef.
Annex B11
Intended use.
Installation instructions
European technical assessment ETA-1 6 / 0 1 4 3 Page 18 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Drill hole cleaning: Just before setting an anchor, the drill hole must be free of dust and debris.
Inadequate hole cleaning = poor load values.
Compressed Air Cleaning (CAC): For all drill hole diameters d0 and all drill hole depths h0.
Blow 2 times from the back of the hole (if needed with nozzle extension) over the whole
length with oil-free compressed air (min. 6 bar at 6 m³/h) until return air stream is free of
noticeable dust.
For drill hole diameters ≥ 32 mm the compressor has to supply a minimum air flow of
140 m³/h.
Brush 2 times with the specified brush (see Table B7) by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting motion and
removing it.
The brush must produce natural resistance as it enters the drill hole (brush Ø ≥
drill hole Ø) - if not the brush is too small and must be replaced with the proper brush
diameter.
Blow again with compressed air 2 times until return air stream is free of noticeable dust.
Annex B12
Intended use.
Installation instructions
European technical assessment ETA-1 6 / 0 1 4 3 Page 19 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Flush 2 times by inserting a water hose (water-line pressure) to the back of the hole
until water runs clear.
Brush 2 times with the specified brush (see Table B7) by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting motion and
removing it.
The brush must produce natural resistance as it enters the drill hole (brush Ø ≥
drill hole Ø) - if not the brush is too small and must be replaced with the proper brush
diameter.
Flush 2 times by inserting a water hose (water-line pressure) to the back of the hole
until water runs clear.
Blow 2 times from the back of the hole (if needed with nozzle extension) over the whole
length with oil-free compressed air (min. 6 bar at 6 m³/h) until return air stream is free of
noticeable dust and water.
For drill hole diameters ≥ 32 mm the compressor has to supply a minimum air flow of
140 m³/h.
Brush 2 times with the specified brush size (brush Ø ≥ drill hole Ø, see Table B7) by
inserting the steel brush Hilti HIT-RB to the back of the hole (if needed with extension)
in a twisting motion and removing it.
The brush must produce natural resistance as it enters the drill hole – if not the brush is
too small and must be replaced with the proper brush diameter.
Blow again with compressed air 2 times until return air stream is free of noticeable dust
and water.
Annex B13
Intended use.
Installation instructions
European technical assessment ETA-1 6 / 0 1 4 3 Page 20 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Flush 2 times by inserting a water hose (water-line pressure) to the back of the hole
until water runs clear.
Brush 2 times with the specified brush (see Table B7) by inserting the steel brush Hilti
HIT-RB to the back of the hole (if needed with extension) in a twisting motion and
removing it.
The brush must produce natural resistance as it enters the drill hole (brush Ø ≥
drill hole Ø) - if not the brush is too small and must be replaced with the proper brush
diameter.
Blow 2 times from the back of the hole (if needed with nozzle extension) over the whole
length with oil-free compressed air (min. 6 bar at 6 m³/h) until return air stream is free of
noticeable dust and water.
For drill hole diameters ≥ 32 mm the compressor has to supply a minimum air flow of
140 m³/h.
Annex B14
Intended use.
Installation instructions
European technical assessment ETA-1 6 / 0 1 4 3 Page 21 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Injection preparation
Tightly attach Hilti mixing nozzle HIT-RE-M to foil pack manifold. Do not modify the
mixing nozzle.
Observe the instruction for use of the dispenser.
Check foil pack holder for proper function. Insert foil pack into foil pack holder and put
holder into dispenser.
The foil pack opens automatically as dispensing is initiated. Depending on the size of
the foil pack an initial amount of adhesive has to be discarded.
Discarded quantities are: 3 strokes for 330 ml foil pack,
4 strokes for 500 ml foil pack,
65 ml for 1400 ml foil pack.
Inject adhesive from the back of the drill hole without forming air voids.
Inject the adhesive starting at the back of the hole, slowly withdrawing the mixer with
each trigger pull.
Fill approximately 2/3 of the drill hole to ensure that the annular gap between the anchor
and the concrete is completely filled with adhesive along the embedment length.
After injection is completed, depressurize the dispenser by pressing the release trigger.
This will prevent further adhesive discharge from the mixer.
Overhead installation and/or installation with embedment depth h ef > 250 mm.
For overhead installation the injection is only possible with the aid of extensions and
piston plugs. Assemble HIT-RE-M mixer, extension(s) and appropriately sized piston
plug (see Table B7). Insert piston plug to back of the hole and inject adhesive. During
injection the piston plug will be naturally extruded out of the drill hole by the adhesive
pressure.
Before use, verify that the element is dry and free of oil and other contaminants.
Mark and set element to the required embedment depth before working time twork has
elapsed. The working time twork is given in Table B6.
For overhead installation use piston plugs and fix embedded parts with e.g. wedges.
Loading the anchor: After required curing time tcure (see Table B6) the anchor can be
loaded.
The applied installation torque shall not exceed the values T max given in Tables B1, B2,
B3 and B4.
Annex B15
Intended use.
Installation instructions
European technical assessment ETA-1 6 / 0 1 4 3 Page 22 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C1: Characteristic resistance for threaded rods under tension load in concrete
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Installation safety factor
Annex C1
Performances
Characteristic resistance under tension load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 23 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Combined pullout and concrete cone failure (continued)
in hammer drilled holes and C30/37 1,04
hammer drilled holes with
hollow drill bit TE-CD or TE- c C40/50 1,07
Increasing
factors for YD and diamond cored
holes C50/60 1,09
Rk in
concrete in diamond cored holes with
roughening tool c C50/60 - 1,0
TE-YRT
Concrete cone failure
2,0
Edge distance 2,0 > h / hef > 1,3 4,6 hef - 1,8 h
1,3
ccr,sp [mm] for
h / hef ≤ 1,3 2,26 hef
1,0 hef 2,26 hef ccr,sp
Annex C2
Performances
Characteristic resistance under tension load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 24 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C2: Characteristic resistance for internally threaded sleeve HIS-(R)N under tension load
in concrete
Annex C3
Performances
Characteristic resistance under tension load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 25 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
2,0
Edge distance 2,0 > h / hef > 1,3 4,6 hef - 1,8 h
1,3
ccr,sp [mm] for
h / hef ≤ 1,3 2,26 hef
1,0 hef 2,26 hef ccr,sp
calculated from the characteristic bond resistance for combined pull-out and concrete cone failure according to:
NRk = Rk · (hef · d1 · ).
Annex C4
Performances
Characteristic resistance under tension load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 26 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C3: Characteristic resistance for Hilti tension anchor HZA / HZA-R under tension load in
concrete
Annex C5
Performances
Characteristic resistance under tension load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 27 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
2,0
Edge distance 2,0 > h / hef > 1,3 4,6 hef - 1,8 h
1,3
ccr,sp [mm] for
h / hef ≤ 1,3 2,26 hef
1,0 hef 2,26 hef ccr,sp
Annex C6
Performances
Characteristic resistance under shear load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 28 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C4: Characteristic resistance for reinforcing bars (rebars) under tension load in concrete
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Installation safety factor
Hammer drilling 21) = inst2) [-] 1,0
Hammer drilling
21) = inst2) [-] - 1,0 -
with hollow drill bit TE-CD or TE-YD
Diamond coring 21) = inst2) [-] 1,2 1,4
Diamond coring
21) = inst2) [-] - 1,0 -
with roughening tool TE-YRT
Hammer drilling in flooded holes 21) = inst2) [-] 1,4
Steel failure rebars
Characteristic resistance NRk,s [kN] 43 62 85 111 173 270 339 388 442
Partial safety factor Ms,N [-] 1,4
Combined pullout and concrete cone failure
Characteristic bond resistance in non-cracked concrete C20/25
in hammer drilled holes and hammer drilled holes with hollow drill bit TE-CD or TE-YD
and diamond cored holes with roughening tool TE-YRT
Temperature range I: 40°C / 24°C Rk,ucr [N/mm2] 14 14 14 14 14 13 13 13 13
Temperature range II: 70°C / 43°C Rk,ucr [N/mm2] 11 11 11 10 10 10 9,5 9,5 9,5
Characteristic bond resistance in non-cracked concrete C20/25
in diamond cored holes.
Temperature range I: 40°C / 24°C Rk,ucr [N/mm2] 9 9 9 9 9 9 9,5 9,5 9,5
Temperature range II: 70°C / 43°C Rk,ucr [N/mm2] 6,5 6,5 6,5 6,5 7 7 7 7 7
Characteristic bond resistance in non-cracked concrete C20/25
in hammer drilled holes and installation in water-filled holes
Temperature range I: 40°C / 24°C Rk,ucr [N/mm2] 12 12 12 12 12 11 11 11 11
Temperature range II: 70°C / 43°C Rk,ucr [N/mm2] 9 9 9 9 8,5 8,5 8,5 8 8
Factor acc. to section 6.2.2.3
k8 [-] 10,1
of CEN/TS 1992-4:2009 part 5
Annex C7
Performances
Characteristic resistance under shear load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 29 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Combined pullout and concrete cone failure (continued)
Characteristic bond resistance in cracked concrete C20/25
in hammer drilled holes and hammer drilled holes with hollow drill bit TE-CD or TE-YD
and diamond cored holes with roughening tool TE-YRT
Temperature range I: 40°C / 24°C Rk,cr [N/mm2] 8,5 9,5 9,5 9,5 10 10 11 11 11
Temperature range II: 70°C / 43°C Rk,cr [N/mm2] 7 8 8 8 8 8 8 8 8
Factor acc. to section 6.2.2.3
k82) [-] 7,2
of CEN/TS 1992-4:2009 part 5
in hammer drilled holes C30/37 1,04
and hammer drilled
holes with hollow drill bit c C40/50 1,07
Increasing
TE-CD or TE-YD and
factors for Rk C50/60 1,09
diamond cored holes
in concrete
in diamond cored holes
with roughening tool TE- c C50/60 1,0
YRT
Concrete cone failure
Annex C8
Performances
Characteristic resistance under tension load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 30 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C5: Characteristic resistance for threaded rods under shear load in concrete
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Partial safety factor
Annex C9
Performances
Characteristic resistance under shear load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 31 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C6: Characteristic resistance for for internally threaded sleeve HIS-(R)N under shear load
in concrete
Annex C10
Performances
Characteristic resistance under shear load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 32 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C7: Characteristic resistance for Hilti tension anchor HZA / HZA-R under shear load in
concrete
Annex C11
Performances
Characteristic resistance under shear load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 33 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C8: Characteristic resistance for reinforcing bars (rebars) under shear load in concrete
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Steel failure without lever arm
Factor according to section 6.3.2.1 of
k22) [-] 1,0
CEN/TS 1992-4 :2009 part 5
Characteristic resistance VRk,s [kN] 22 31 42 55 86 135 169 194 221
Partial safety factor Ms,v [-] 1,5
Steel failure with lever arm
Characteristic resistance M0Rk,s [Nm] 65 112 178 265 518 1012 1422 1749 2123
Partial safety factor Ms,v [-] 1,5
Concrete pryout failure
Factor in equation (5.7) of TR 029 or acc.
to equation (27) of CEN/TS 1992-4 :2009 k1) = k32) [-] 2,0
part 5
Concrete edge failure see TR 029
Annex C12
Performances
Characteristic resistance under shear load in concrete
Design according to “EOTA Technical Report TR 029, 09/2010” or “CEN/TS 1992-4:2009”
European technical assessment ETA-1 6 / 0 1 4 3 Page 34 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Non-cracked concrete
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Displacement V0 [mm/kN] 0,06 0,06 0,05 0,04 0,04 0,03 0,03 0,03
Displacement V [mm/kN] 0,09 0,08 0,08 0,06 0,06 0,05 0,05 0,05
Annex C13
Performances
Displacements
European technical assessment ETA-1 6 / 0 1 4 3 Page 35 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Annex C14
Performances
Displacements
European technical assessment ETA-1 6 / 0 1 4 3 Page 36 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C13: Displacements for Hilti tension anchor HZA / HZA-R under tension load
Table C14: Displacements for Hilti tension anchor HZA / HZA-R under shear load
Annex C15
Performances
Displacements
European technical assessment ETA-1 6 / 0 1 4 3 Page 37 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Non-cracked concrete
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Displacement V0 [mm/kN] 0,05 0,05 0,04 0,04 0,04 0,03 0,03 0,03 0,03
Displacement V [mm/kN] 0,08 0,07 0,06 0,06 0,05 0,05 0,05 0,04 0,04
Annex C16
Performances
Displacements
European technical assessment ETA-1 6 / 0 1 4 3 Page 38 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Seismic design shall be carried out according TR 045 “Design of Metal Anchors Under
Seismic Action”
Table C17: Characteristic resistance for threaded rods under tension loads for seismic category
C1 in concrete
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Steel failure threaded rods
Table C18: Characteristic resistance for threaded rods under shear loads for seismic category C1
in concrete
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Steel failure without lever arm
Characteristic resistance HIT-V VRk,s,seis [kN] 0,5 · As · fuk
Characteristic resistance Commercial
VRk,s,seis [kN] 0,35 · As · fuk
standard threaded rod
Table C19: Displacement for threaded rods under tension loads for seismic category C1 in
concrete
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Displacement1) N,seis [mm] 2,7 3,0 3,3 3,9 4,5 5,1 5,6 6,0
1) Maximum displacement during cycling (seismic event).
Table C20: Displacement for threaded rods under shear loads for seismic category C1 in concrete
Threaded rod, HIT-V-… M8 M10 M12 M16 M20 M24 M27 M30
Displacement1) V,seis [mm] 3,2 3,5 3,8 4,4 5,0 5,6 6,1 6,5
1) Maximum displacement during cycling (seismic event).
Annex C17
Performances
Characteristic values for seismic performance category C1 and displacements
Design according to “EOTA Technical Report TR 045, 02/2013”
European technical assessment ETA-1 6 / 0 1 4 3 Page 39 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C21: Characteristic resistance for internally threaded sleeve HIS-(R)N under tension load
for seismic category C1 in concrete
Table C22: Characteristic resistance for internally threaded sleeve HIS-(R)N under shear load for
seismic category C1 in concrete
Table C23: Displacement for internally threaded sleeve HIS-(R)N under tension loads for seismic
category C1 in concrete
Table C24: Displacement for internally threaded sleeve HIS-(R)N under shear loads for seismic
category C1 in concrete
Annex C18
Performances
Characteristic values for seismic performance category C1 and displacements
Design according to “EOTA Technical Report TR 045, 02/2013”
European technical assessment ETA-1 6 / 0 1 4 3 Page 40 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C25: Characteristic resistance for Hilti tension anchor HZA / HZA-R under tension load for
seismic category C1 in concrete
HZA / HZA-R M12 M16 M20 M24 M27
Steel failure
Characteristic resistance HZA NRk,s,seis [kN] 46 86 135 194 252
Characteristic resistance HZA-R NRk,s,seis [kN] 62 111 173 249 -
Partial safety factor Ms,N,seis [-] 1,4
Combined pullout and concrete cone failure
Characteristic bond resistance in cracked concrete C20/25
in hammer drilled holes and hammer drilled holes with hollow drill bit TE-CD or TE-YD
and diamond cored holes with roughening tool TE-YRT
Temperature range I: 40°C / 24°C Rk,seis [N/mm2] 9,0 9,5 9,5 10,0 11,0
Temperature range II: 70°C / 43°C Rk,seis [N/mm2] 7,5 7,5 8,0 8,0 8,0
Table C26: Characteristic resistance for Hilti tension anchor HZA / HZA-R under shear load for
seismic category C1 in concrete
HZA / HZA-R M12 M16 M20 M24 M27
Steel failure without lever arm
Characteristic resistance HZA VRk,s,seis [kN] 23 43 67 97 126
Characteristic resistance HZA-R VRk,s,seis [kN] 31 55 86 124 -
Table C27: Displacement for Hilti tension anchor HZA / HZA-R under tension loads for seismic
category C1 in concrete
Table C28: Displacement for Hilti tension anchor HZA / HZA-R under shear loads for seismic
category C1 in concrete
Annex C19
Performances
Characteristic values for seismic performance category C1 and displacements
Design according to “EOTA Technical Report TR 045, 02/2013”
European technical assessment ETA-1 6 / 0 1 4 3 Page 41 sur 41 | 1 8 / 0 4 / 2 0 1 6
English translation prepared by CSTB
Table C29: Characteristic resistance for reinforcing bars (rebars) under tension load for seismic
category C1 in concrete
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Steel failure rebars
Characteristic resistance NRk,s [kN] 43 62 85 111 173 270 339 388 442
Combined pullout and concrete cone failure
Characteristic bond resistance in cracked concrete C20/25
in hammer drilled holes and hammer drilled holes with hollow drill bit TE-CD or TE-YD
and diamond cored holes with roughening tool TE-YRT
Temperature range I: 40°C / 24°C Rk,seis [N/mm2] 8,0 9,0 9,0 9,5 9,5 10,0 11,0 11,0 11,0
Temperature range II: 70°C / 43°C Rk,seis [N/mm2] 6,5 7,5 7,0 7,5 8,0 8,0 8,0 8,0 8,0
Table C30: Characteristic resistance for reinforcing bars (rebars) under shear loads for seismic
category C1 in concrete
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Steel failure without lever arm
Characteristic resistance VRk,s [kN] 22 31 42 55 86 135 169 194 221
Table C31: Displacement for reinforcing bars (rebars) under tension loads for seismic category
C1 in concrete
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Displacement1) N,seis [mm] 3,0 3,3 3,6 3,9 4,5 5,3 5,7 6,0 6,3
1) Maximum displacement during cycling (seismic event).
Table C32: Displacement for reinforcing bars (rebars) under shear loads for seismic category C1
in concrete
Reinforcing bar (rebar) 10 12 14 16 20 25 28 30 32
Displacement1) V,seis [mm] 3,5 3,8 4,1 4,4 5,0 5,8 6,2 6,5 6,8
1) Maximum displacement during cycling (seismic event).
Annex C20
Performances
Characteristic values for seismic performance category C1 and displacements
Design according to “EOTA Technical Report TR 045, 02/2013”