• Key Findings
• Executive Summary
• PV Modules Cleaning Facts
• What makes our system Ideal/ Unique?
• Why to work with us?
• Disadvantages of Manual Cleaning
• Why use Floppy Sprinkler System
• Floppy Sprinkler solution
• Filtration System
• Floppy VS Solid state sprinklers
• Solar Manafactuers cleaning Guidelines
Key Findings
• Life of solar panels will be greatly shortened without proper cleaning due to
aggregation of
Non-compliance to clean the mod- Bird drops easy to cause hot spots,
ules,pollution is increasing and losses damaging
rising
the whole panel quickly
Executive Summary
• We are the sister company of Philadelphia Solar, the largest PV modules manufacturer and EPC developer in the ME region.
• Is the exclusive agent for Floppy Sprinklers solutions with a trained and experienced engineering team.
• Best in the industry for outstanding customer service and technical support.
• Full after sales and service team provider with an experienced and trained team.
• Pollution, traffic dust, leaves and bird droppings prevents sunlight from reaching the solar panels.
• Panels should be cleaned early morning or night time when the temperature is low.
What makes our system ideal/unique?
•The Floppy sprinkler has no moving parts, resulting in no wear and tear.
•Works at night when panels are cool and minimum preventive maintenance is
needed.
• Manually cleaning solar panels is not always safe for the labor and
solar panels coated glass.
Labor Saving
The solid set floppy system can be automated and fewer operators are needed to
manage large areas.
Maintenance Saving
With no moving and wearing parts it requires no maintenance.
Cooling
Floppy is suitable for cooling - important for higher yields in hot climates.
Flow Control
Floppy has flow control equipped. Ensures accurate fertigation, pesticide control and
foliar feed.
• It casts no shadows on the solar panels thus does not affect generation.
Automation
. Floppy has much higher efficiency, at least 30% Solid State Irrigation has Increased Water Con-
less water and less energy to pump. Floppy 28 sumption and works at minimal 3 bars.
psi instead of 40 or higher for impact Sprinklers.
. Floppy has no moving or wearing parts, no Minimal warranty compared to Floppy sys-
seals, no washers, no springs that can wear tems.
out.
. Floppy has flow control. Very accurate ferti- Does not have a flow controller to control
gation even on slopes or long lines. water consumption
. Floppy has better infield CU and Du than Solid state irrigation may be affected for the
impact Sprinklers and wind does not distort pattern.
the pattern.
Solar Manafactuers cleaning Guidelines
Introduction: clean gloves to prevent fingerprints and other dirt from
Solar panels work by allowing light into the solar cells. staying on the glass.
The more light that hits a panel, the more power it will
generate. Due to the upwards angle of solar panels, 2. Do not use aggressive tools or abrasive material
they are more prone to dirt such as bird droppings and that may cause scratch of the glass. Such as blades,
Air pollution, accumulated dust, grease or any other knives, steel wool and other abrasive materials.
particles in the air that gets caught on the solar panels.
3. Various types of soft foams, non-woven fabrics,
Accumulated dirt will reduce the amount of light brooms, soft sponges and soft brushes are permitted
transmitted to the cells and hence it will significantly
affect the power output. In addition, dirty parts of the 4. Glass cleaner, alcohol, ethanol or methanol are
panel get hotter faster than other parts, which creates only allowed to use in case of the water cannot clean
hotspots. These hotspots can increase the rate at which properly.
solar panels deteriorate.
5. Never use steam or corrosive chemicals to speed up
General Instructions: the cleaning process.
1. Do not use bare fingers or hands without gloves
to touch or handle the glass surface of modules. Wear 6. Water with low mineral content should be used
otherwise dried minerals will be deposited on glass.
Solar Manafactuers cleaning Guidelines
If low mineral water is not available in the area where 10. The back side of bifacial modules can also generate
modules installed, it is suggested to add the sodium power; hence, it is necessary to clean the back side.
chloride ≤2‰ in water to avoid depositing the dried
minerals on glass. 11. The cleaning of the transparent backsheet of
bifacial modules should be done using soft cotton
7. The pressure of cleaning water should be less than base material to remove the dust or dirty. Or you can
5.4 KPa knowing that Philadelphia Solar PV use compressed air (pressure less than 2.4 KPa) to blow
modules are designed to withstand high snow load (5.4 away the dust/dirties. Do not use any chemicals or
KPa) and wind load 2.4 KPa water in case of electrical shock.
12. Through any means, the cleaning should not
8. The difference between water temperature and make a damage of the backsheet of bifacial module. If
modules temperature should be controlled at a certain happens, please replace with a new module.
range from -5 to 10 . Also, the pH value of water must
be around 6 - 8 since glass of the module is coated by 13. Philadelphia Solar modules are designed to
anti-reflected material. withstand high snow loads. However, if removing snow
is desired to enhance production, use a brush to gently
9. Do not clean the module when the cable or the glass remove snow. Do not try to remove frozen snow or ice
are broken, which may raise the risk of electric shock. from modules since that may cause microcracks in cells.
Solar Manafactuers cleaning Guidelines
14. Do not stand, step, walk and/or jump on modules It is recommended that the customer evaluates the
under any circumstances. Localized heavy loads cleaning frequency according to the actual situation of
may cause severe micro-cracks at cell level, which in the region where modules installed in.
turn may compromise module reliability and void
Philadelphia’s warranty. For a large-scale photovoltaic power plant with a
large number of modules, the time suitable for the
Cleaning Time, Cycle and Region cleaning is short each day; it is necessary to plan the
Philadelphia Solar recommends cleaning during early cleaning cycle and divide regions based on specific
morning or night when solar radiation is low, and the circumstances of the electric field. The subregion
module is cooler especially in region of hotter region. division in the cleaning work should be done according
to the electrical structure of the photovoltaic station
and should ensure that each of the cleaning work can
cover all components connected to several combiner
boxes or inverters.
Contact Us