DBV3 Digital Scroll R410a 50-60Hz MS0328A-0316 Npy
DUNHAM-BUSH PRODUCT
410A
MILESTONE
UNITED KINGDOM
ECUADOR
PERU
BRAZIL
BOLIVIA
SOUTH AFRICA
URUGUAY
Dunham-Bush Profile
Dunham-Bush, one of the world’s top commercial air conditioning manufacturers, has long been
committed to offering creative solutions for the customer’s requirements over its 120 years history in
the HVAC/R. Dunham-Bush offers a complete range of HVAC/R products such as large chillers, VRF,
unitary, airside system and thermal energy storages for residences, commercial buildings and
industrial facilities. Dunham-Bush is striving to be the leader in the commercialization of green
technologies. Today, by utilizing our global network of sales and service offices, Dunham-Bush is
offering our value-added products and solutions to all corners of the world.
M
a
t reciprocating compressor.
DUNHAM-BUSH MALAYSIA
pany was built. Dunham-Bush Malaysia; founded in 1987, adhered to the innovation system of focusing
on customers’ demands to drive global research & design, and superior quality
manufacturing. Nowadays Dunham-Bush Malaysia are creating innovative cooling
solutions appropriate to the individual requirements of commercial building, schools,
hospitals, airports, factories and residences. No matter where you are, what we deliver
is the same: high performing, highly engineered cooling solutions developed to take on
the challenges of the 21st century.
OVERVIEW
For DBV central air conditioning system, DBV-MTD series, the capacity could be up to 64HP, and free combination from 8~16HP with 2 HP
increment. User friendly design, can meet all requirements for different environment, so it’s widely used today’s intelligent buildings, such
as offices, shopping malls, plants, schools, hospitals, clubs, commercial buildings etc.
High efficiency digital scroll compressor with large capacity, combined with the R410A environmental refrigerant, completely satisfies the
RoHS, and make DBV to be energy-saving and environmentally friendly, long performance life, easy for maintenance.
DBV-MTD series is the right solution for Tropical (T3) operation.
High efficiency cross flow low pressure drop fins High efficiency inner-threaded copper pipes
Greatly reduce air resistance greatly Enhance the turbulent motion, break the
refrigerant bounding layer and optimize
Significantly improve defrosting cycle
Heat exchange efficiency
Nomenclature
DBV - M T D 8 E 3 G
DB VRF R410A
U : Standalone Unit T3
M : Modular Unit
E : 380~415V/3ph/50Hz
C : Side Discharge (Hot Air) F : 380~415V/3ph/60Hz
T : Top Discharge (Hot Air) G : 220V/3ph/60Hz
Suction
Inverter EMC Regulation Digital Scroll System
Ampere
Orbiting Scroll 5th
7th
11th
13th
17th
Provides 10% to 100% stepless capacity output to precisely
19th
control room temperature.
0 1 2 3 4 5
Less electromagnetic interference, no EMC problem.
EMW
When the PWM solenoid valve is closed, two stators engage to achieve an airtight
state and loading functionality.
The compressor can adjust the ratio of ONs to OFFs freely to control the refrigerant
output of the compressor.
efficiency
new
old
common
Common heat exchange structure Sub-cooling Technology
Gas Liquid
refrigerant refrigerant
Gas Liquid
refrigerant refrigerant
Gas Gas-Liquid Phase Liquid
Gas Phase Phase Liquid
refrigerant refrigerant
37.1℃(98.8°F)
43℃(109.4°F)
75℃(167°F) 75℃(167°F)
2-in-1
Gas Liquid
refrigerant refrigerant
Gas
refrigerant
Liquid
Gas 相 refrigerant
refrigerant
Hydrophilic fins and inner-threaded copper pipes optimize heat exchange efficiency. Specially coated blue fins enhance durability and
protect against corrosion from air, water and other corrosive agents, assures a longer coil service life.
frosting comparison
air resistance and air flow
DB:2℃ WB:1℃
new fin
relative frost
RC
defrost
1
2
Cooling operation
Digital
Non-digital
Time
L ow sound operation
Low-sound operation is visualized by
Through calculations and simulation of air
optimized design using the well-chosen low flow during fan operation, the fan blade
noise and vibration components, and CFD design is optimized to lower down the air
vortex, air flow resistance and operation
software simulation. noise.
New developed fan conventional fan mute
100
board. Silent operation will be activated *X hours after
the peak temperature, and it will go back to normal
50
operation after *Y hours.
0
8hrs 9hrs
58
SounddB
10d B Silent
Notes:
50 Silent mode mode
*X is initial set, 6, 8, 10 hours ; *Y is initial set, 8, 9, 10 hours start end
This function can be activated by setting at site.
8:00 12:00 16:00 20:00 0:00 4:00 8:00
Temperature(load) curve shown in the graph is just an example.
Solenoid valve
Solenoid valve
Check valve
EXV
Up to 64 indoor units
EXV
5st stage
1st stage 3st stage
n A B C D
n+1 B C D A
n+2 C D A B
n+3 D A B C
40
Outdoor air dry bulk temp.
50 54°C
30
40 27℃
20
30
10
Continuous
20
operation range Continuous
0
10
operation range
-10
0
-15°C -20 -20℃
(℃)-10 (℃)
-30
ground high voltage temperature current low voltage motor overheat compressor pressure phase phase loss
protection protection protection protection protection protection overload protection protection protection protection
Remote Service
depend on Dunham-bush strong technical strength, the AC
system can remote diagnosis online for 24 hours a day, and offer
you an easy and trouble free using.
Indoor centralized intelligent control Forecasting of maintenance information, extends service life, and
ensures operation in high efficiency.
Perfect unit monitor and control function, give a full
range of dynamic monitoring to indoor unit operation; Rapid processing for malfunction alarm, provides reliable service
Establishes a Modbus network comprising up to 1,024 within the shortest time.
indoor units within a maximum connection length of
1,200m
Dunham-bush intelligent network control system , which is based on professional technical strength, concentrates on providing
customized system solution. We provide customized solutions include Local (LAN) control, WAN control, to manage and control AC
system online automatically and remotely. Also provide professional solutions such as electric charge distribution, BMS and schedule
management etc. to enterprises or customers, and help them to master the AC using situation.
Max. 4 gateways
PC
LAN
Web accessa
K1 K2 E X Y E
Switch
Max. connection of
64 indoor units
Modbus
gateway
DB-ICC01
DB-OCC01
DB-ICC01
DB-ICC01
DB-OCC01
DB-OCC01
Modbus
gateway
DB-ICC01
DB-OCC01
Control functions: mode setting, air speed setting, temperature setting, emergency stop
Display functions: operation mode, air speed, ambient temp., error codes
BACnet access
Dunham-Bush BACnet gateway integrates DBV III system into BACnet BMS system. A BACnet gateway (CCM08) can connects up to 256
Indoor Units, or 128 Outdoor Units. Large system with multiple of CCM08, CCM08 can be connected to a HUB and then connects to the
BMS monitoring system.
Full range of indoor units for options, apply to a variety of needs for
commercial or residential Buildings.
In the commercial era with high cost of land, the key factor of how to seize business opportunity is to make full use of the space
resources. Dunham-bush DC inverter intelligent VRF system offer full range indoor unit options. Thanks to the stylish appearance and
slim body, the indoor units require little space for flexible installation, and save available space, that will help you to take the grand prizes
in today’s commercial competition.
Special air supplyway, Ultra-thin machine body Suitable for larger space The major feature of high
creates confortable airflow design, work well in with suspended ceiling, big pressure patio type indoor
effect for long and narrow combination with the sites with whole ceiling; unit is the ESP can be up
space and corners, such as optimizedmute centrifugal Four air discharge ports to 196Pa. Powerful motive
meeting rooms, restaurants, fan, creates quiet and provide strong air flow force, and the flexible duct
shops, and brings different comfortable environment, circulation to cool or heat connection realizes long
AC enjoyment. also can meet various every corner of a room and distance air supply
demands of AC for hotels, you can easily enjoy according to space
restaurants, KTV etc. 360°air supply. features, wider comfort-
able environment, make
you enjoy easily whenever
and wherever possible.
The thin and light machine Mini body, the installation Absorb the fashion design Exquisite appearance
body, can be concealed in won’t affect the space elements in Europe and design, can well match with
skirting board of partial ceiling. comfort; Suitable for the America. Easy to make the interior decoration. It’s
It’s suitable for hotel rooms special construction, such choice of floor standing or especially suitable for the
with ordinary floor height; as L type or long rooms, ceiling installation according rooms with limited height
through the rational design of air supply can be well- to the various requirements and less space (such as
heat exchange components distributed through the of environment. Perfect hotel economy rooms,
and connection pipes, get pipe connection, and adaption to the decoration worker rooms etc,.); Do not
the excellent mute effect, satisfy the large space space, especially suitable need any form of
and offer you a quiet, requirement. for the decorated already suspended ceiling, that
comfortable and cozy time. transformation projects, or brings great convenience
simple commercial sites for installation, and creates
without suspended ceiling. easy enjoyment of AC life.
Notes:
Capacities are based on the following conditions:
Cooling*: Indoor temperature 27oC (80.6oF) DB/19oC (66.2oF) WB; Outdoor temperature 35oC (95oF) DB/24oC (75.2oF) WB.
Cooling**: Indoor temperature 27oC (80.6oF) DB/19oC (66.2oF) WB; Outdoor temperature 46 oC (114.8oF) DB/24oC (75.2oF) WB.
Heating: Indoor temperature 20oC (68oF) DB/15oC (59oF) WB; Outdoor temperature 7oC (44.6oF) DB/6oC (42.8oF) WB.
Piping length: Interconnecting piping length 7.5m, level difference of zero.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
Conversion Formula: RT=kW×0.284; kcal/h= kW×860; Btu/h= kW×3412; CFM=m3/h×0.588
Notes:
Capacities are based on the following conditions:
Cooling*: Indoor temperature 27oC (80.6oF) DB/19oC (66.2oF) WB; Outdoor temperature 35oC (95oF) DB/24oC (75.2oF) WB.
Cooling**: Indoor temperature 27oC (80.6oF) DB/19oC (66.2oF) WB; Outdoor temperature 46oC (114.8oF) DB/24oC (75.2oF) WB.
Heating: Indoor temperature 20oC (68oF) DB/15oC (59oF) WB; Outdoor temperature 7oC (44.6oF) DB/6oC (42.8oF) WB.
Piping length: Interconnecting piping length 7.5m, level difference of zero.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
Conversion Formula: RT=kW×0.284; kcal/h= kW×860; Btu/h= kW×3412; CFM=m3/h×0.588
ONE-WAY CASSETTE
Acetaldehyde
153mm
UItra Thin Single-flow design suits
corner installation
750mm
50Hz Specifications
Model DBV-CS18AG DBV-CS22AG DBV-CS28AG DBV-CS36AG DBV-CS45AG DBV-CS56AG
60Hz Specifications
Model DBV-CS18BG DBV-CS22BG DBV-CS28BG DBV-CS36BG DBV-CS45BG DBV-CS56BG
Two-way Cassette
Quiet operation
Optimized airflow duct with low resistance greatly reduces noise,
minimum down to 24dB(A).
305mm
300mm
750mm
50Hz Specifications
Model DBV-CD22AG DBV-CD28AG DBV-CD36AG DBV-CD45AG DBV-CD56AG DBV-CD71AG
Power supply 1-phase, 220-240V, 50Hz
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800 6,100
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
kW 2.6 3.2 4.0 5.0 6.3 8.0
Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400 6,900
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300
57 57 60 92 108 154
Power input Cooling W
Heating 57 57 60 92 108 154
Rated Cooling 0.35 0.45 0.45 0.55 0.55 0.75
A
current Heating 0.35 0.45 0.45 0.55 0.55 0.75
m3/h 654/530/410 654/530/410 725/591/458 850/670/550 980/800/670 1,200/1,000/770
Airflow rate(H/M/L)
CFM 385/312/241 385/312/241 427/348/270 500/394/324 577/471/394 706/589/453
Sound pressure level(H/M/L) dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34
Type R410A
Refrigerant
Control method EXV
Net dim.(W×H×D)
mm 1,172×299×591 1,172×299×591 1,172×299×591 1,172×299×591 1,172×299×591 1,172×299×591
Body Gross dim.(W×H×D) 1,355×400×675 1,355×400×675 1,355×400×675 1,355×400×675 1,355×400×675 1,355×400×675
Net/gross weight kg 34/42.5 34/42.5 34/42.5 36.5/45 36.5/45 36.5/45
Net dim.(W×H×D)
mm 1,430×53×680 1,430×53×680 1,430×53×680 1,430×53×680 1,430×53×680 1,430×53×680
Panel Gross dim.(W×H×D) 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765
Net/gross weight kg 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53
Piping
connections G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9
Drain piping mm OD Ф32 OD Ф32 OD Ф32 OD Ф32 OD Ф32 OD Ф32
Standard controller - Wireless remote controller(RM05/BG(T)E-A)
60Hz Specifications
Model DBV-CD22BG DBV-CD28BG DBV-CD36BG DBV-CD45BG DBV-CD56BG DBV-CD71BG
Power supply 1-phase, 208-230V, 60Hz
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800 6,100
Btu/h 7,500 9600 12,300 15,400 19,100 24,200
kW 2.6 3.2 4 5 6.3 8
Heating capacity kcal/h 2200 2,800 3,400 4,300 5,400 6,900
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300
78 78 83 115 133 205
Power input Cooling W
Heating 78 78 83 115 133 205
Rated Cooling 0.35 0.45 0.45 0.55 0.55 0.75
A
current 0.35 0.45 0.45 0.55 0.55 0.75
Heating
m3/h 674/509/381 674/509/381 740/577/435 878/689/561 941/776/654 1,236/1,110/864
Airflow rate(H/M/L)
CFM 397/300/224 397/300/224 436/340/256 517/406/330 554/457/385 727/653/509
Sound pressure level(H/M/L) dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34
Type R410A
Refrigerant Control
method EXV
Net dim.(W×H×D)
mm 1172×299×591
Body Gross dim.(W×H×D) 1355×400×675
Net/gross weight kg 34/42.5 34/42.5 34/42.5 36.5/45 36.5/45 36.5/45
Net dim.(W×H×D)
mm 1430×53×680
Panel Gross dim.(W×H×D) 1525×130×765
Net/gross weight kg 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15
L(flare) mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф9.53 Ф9.53
Piping
connections G(flare) mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф15.9 Ф15.9
Drain piping mm OD Ф32 OD Ф32 OD Ф32 OD Ф32 OD Ф32 OD Ф32
Standard controller - Wireless remote controller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temp.: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 68°F(20°C)DB, outdoor temp.: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal)
3. Sound Level is measured 4.59ft. (1.4m) below the unit
Four air discharge ports provide strong air flow circulation to cool or Streamline plate ensures quiet operation
heat every corner of a room and evenly distribute temperature. High Advanced 3-D spiral fan design reduces air resistance and
airflow mode can maximize the conditioning effect in rooms that are operation noise.
over 3m high.
50Hz Specifications
Model DBV-CFC15AG DBV-CFC22AG DBV-CFC28AG DBV-CFC36AG DBV-CFC45AG
Power supply 1-phase,220-240V,50Hz
kW 1.5 2.2 2.8 3.6 4.5
Cooling capacity kcal/h 1300 1900 2400 3100 3900
Btu/h 5100 7500 9600 12300 15400
kW 1.7 2.4 3.2 4 5
Heating capacity kcal/h 1500 2100 2700 3400 4300
Btu/h 5800 8200 10900 13600 17100
Cooling 36 50 50 56 56
Rated input W
Heating 36 50 50 56 56
Cooling 0.22 0.22 0.22 0.25 0.25
Rated current A
Heating 0.22 0.22 0.22 0.25 0.25
m3/h 501/435/283/208 522/414/313/238 522/414/313/238 610/521/409/314 610/521/409/314
Airflow rate(SH/H/M/L)
CFM 295/256/167/98 307/244/184/140 307/244/184/140 359/307/241/185 359/307/241/185
Sound pressure level(H/M/L) dB(A) 34.9/32.5/22.5 35.8/33.4/23.4 35.8/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8
Type R410A
Refrigerant
Control method EXV
Net dim.(W×H×D) 570x260x570 570x260x570 570x260x570 570x260x570 570x260x570
mm
Indoor Unit Gross dim.(W×H×D) 675x285x675 675x285x675 675x285x675 675x285x675 675x285x675
Net/Gross weight kg 16/19.5 16/20 16/20 18/22 18/22
Net dim.(W×H×D) 647x50x647 647x50x647 647x50x647 647x50x647 647x50x647
mm
Panel Gross dim.(W×H×D) 715x123x715 715x123x715 715x123x715 715x123x715 715x123x715
Net/Gross weight kg 2.4/4.5 2.4/4.5 2.4/4.5 2.4/4.5 2.4/4.5
L(flare) mm Φ6.35 Φ6.35 Ф6.35 Φ6.35 Ф6.35
Piping connections G(flare) mm Φ12.7 Φ12.7 Ф12.7 Φ12.7 Ф12.7
Drain piping mm OD Ф25 OD Ф25 OD Ф25 OD Ф25 OD Ф25
Standard controller Wireless remote controller (RM05/BG(T)E-A)
60Hz Specifications
Model DBV-CFC22BG DBV-CFC28BG DBV-CFC36BG DBV-CFC45BG
Power supply 1-phase, 208-230V 60Hz
kW 2.2 2.8 3.6 4.5
Cooling capacity kcal/h 1,900 2,400 3,100 3,900
Btu/h 7,500 9,600 12,300 15,400
kW 2.4 3.2 4 5
Heating capacity kcal/h 2,100 2,800 3,400 4,300
Btu/h 8,200 10,900 13,600 17,100
Cooling 51 52 58 58
Power input W
Heating 43 44 50 51
Rated Cooling 0.175 0.175 0.21 0.21
A
current Heating 0.175 0.175 0.21 0.21
m3/h 532/397/292/215 539/408/310/231 632/496/359/263 632/496/359/263
Airflow rate(SH/H/M/L)
CFM 313/234/172/127 317/240/182/136 372/292/211/155 372/292/211/155
Sound pressure level(H/M/L) dB(A) 35.8/33.4/23.4 35.8/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8
Type R410A
Refrigerant
Control method EXV
Net dim.(W×H×D) 570×260×570
mm
Body Gross dim.(W×H×D) 675×285×675
Net/Gross weight kg 16/20 16/20 18/22 18/22
Net dim.(W×H×D) 25-15/32×1-31/32×25-15/2(647×50×647)
mm
Panel Gross dim.(W×H×D) 28-5/32×4-27/32×28-5/32 (715×123×715)
Net/Gross weight kg 3/5 3/5 3/5 3/5
L(flare) mm Ф6.35 Ф6.35 Ф6.35 Ф6.35
Piping
connections G(flare) mm Ф12.7 Ф12.7 Ф12.7 Ф12.7
Drain piping mm OD Ф25 OD Ф25 OD Ф25 OD Ф25
Standard controller Wireless remote controller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temp.: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 68°F(20°C)DB, outdoor temp.: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal)
3. Sound Level is measured 4.59ft. (1.4m) below the unit
Four-way Cassette
750mm
230mm
Diffuser
50Hz Specifications
Model DBV-CF28AG DBV-CF36AG DBV-CF45AG DBV-CF56AG DBV-CF71AG
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature. : 27°CDB,19°CWB,outdoor temperature.:35°CDB, equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature.: 20°CDB,outdoor temperature.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal)
3. Sound level is measured at 1.4m below the unit.
60Hz Specifications
Model DBV-CF28BG DBV-CF36BG DBV-CF45BG DBV-CF56BG DBV-CF71BG
kW 8 9 10 11.2 14
Cooling capacity kcal/h 6,900 7,700 8,600 9,600 12,000
Btu/h 27,300 30,700 34,100 38,200 47,800
kW 9 10 11.1 12.5 15
Heating capacity kcal/h 7,700 8,600 9,500 10,800 12,900
Btu/h 30,700 34,100 37,900 42,700 51,200
Cooling 115 160 160 160 180
Power input W
Heating 115 160 160 160 180
Cooling 0.5 0.7 0.7 0.7 0.8
Rated current A
Heating 0.5 0.7 0.7 0.7 0.8
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping:
26.25ft. (8m) (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping:
26.25ft. (8m) (horizontal)
3. Sound Level is measured 4.59ft. (1.4m) below the unit
750mm
210mm
Ceiling
Ceiling
Uniform 210mm in height, compact design for easy A drain pump with 750mm pumphead is an
locate where space ceiling is limited, optional accessory.
The whole body adopts fireproof plastic material,
the minimum weight is 14kg.
sound-sensitive places.
V
shape evaporator-- good for heat C
onvenient for installation
exchanging and maintenance
V shape evaporator design enhances heat exchanging The EXV is fixed inside the indoor unit.
efficiency about 22%.
50Hz Specifications
Model DBV-DL18AG DBV-DL22AG DBV-DL28AG DBV-DL36AG DBV-DL45AG DBV-DL56AG DBV-DL71AG
Power supply 220-240V~1Ph~50Hz
kW 1.8 2.2 2.8 3.6 4.5 5.6 7.1
Cooling capacity kcal/h 1500 1900 2400 3100 3900 4800 6100
Btu/h 6100 7500 9600 12300 15400 19100 24200
kW 2.2 2.6 3.2 4 5 6.3 8
Heating capacity kcal/h 1900 2200 2800 3400 4300 5400 6900
Btu/h 7500 8900 10900 13600 17100 21500 27300
Cooling 59 59 59 65 105 105 130
Rated input W
Heating 59 59 59 65 105 105 130
60Hz Specifications
Model DBV-DL18BG DBV-DL22BG DBV-DL28BG DBV-DL36BG DBV-DL45BG DBV-DL56BG DBV-DL71BG
Power supply 208-230V~1Ph~60Hz 208-230V~1Ph~60Hz 208-230V~1Ph~60Hz 208-230V~1Ph~60Hz 208-230V~1Ph~60Hz 208-230V~1Ph~60Hz 208-230V~1Ph~60Hz
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m
(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m
(horizontal)
3.Sound level is measured at 1.4m below the air outlet.
* External static pressure is based on high speed indoor air flow.
Convenient installation
The EXV is fixed inside of the indoor unit.
Standard filter is housed in an aluminum frame, which is removable from the bottom in the downward direction.
Suction chamber is included as standard equipment.
Fresh air hole, air inlet/outlet flange are standard for easy duct connection.
A rear air inlet is standard and an inlet at the bottom is optional. Both use the same connectable duct.
Air intake from back Air intake from below Drain pump as standard
750mm
Ceiling
50Hz Specifications
Model DBV-DMD15AG DBV-DMD22AG DBV-DMD28AG DBV-DMD36AG DBV-DMD45AG DBV-DMD56AG
Cooling 56 57 57 61 98 103
Rated input W
Heating 56 57 57 61 98 103
Type R410A
Refrigerant Control
method EXV
kW 7.1 8 9 11.2 14
Sound pressure level(H/M/L) dB(A) 41.4/39/35 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0
Type R410A
Refrigerant
Control method EXV
Net dimension W×H×D mm 1,180x210x500 1,230×270×775 1,230×270×775 1,230×270×775 1,290×300×865
60Hz Specifications
Model DBV-DMD22BG DBV-DMD28BG DBV-DMD36BG DBV-DMD45BG DBV-DMD56BG DBV-DMD71BG
Sound pressure level(H/M/L) dB(A) 36/35/32 36/35/32 38.6/37.5/33.8 39/37.9/34 39/37.9/34 41.4/39/35
Type R410A
Refrigerant Control
method EXV
Indoor mm
Unit Gross dim.(W×H×D) 870×285×525 1115×285×525 1115×285×525 1335×285×525
Min.
420mm 450mm
INDOOR UNIT
The maximum distance for air supply is about 14m at height of 6.5m.
With a 420mm (models 71 to 160) thick body, the minimum distance required above the ceiling is 450mm.
ceiling
Drain pump with 750mm pump head is optional Double-skin drainage pan provide double protection for
(models 71 to 160) ceilings (models 71 to 160 and models 400 to 560)
50Hz Specifications
Model DBV-DH71AG DBV-DH80AG DBV-DH90AG DBV-DH112AG DBV-DH140AG DBV-DH160AG
kW 7.1 8 9 11.2 14 16
ESP (external static pressure) Pa 25(25~ 196) 37(37~ 196) 37(37~ 196) 50(50~ 196) 50(50~ 196) 50(50~ 196)
Sound pressure level(H/M/L) dB(A) 48/46/44 48/46/44.5 52/49/47 52/49/47 53/50/48 54/52/50
Type R410A
Refrigerant
Control method EXV
kW 20 25 28 40 45 56
ESP (external static pressure) Pa 200(50~280) 200(50~280) 200(50~280) 200(50~280) 200(50~280) 200(50~280)
Sound pressure level(H/M/L) dB(A) 59/55/52 59/55/52 59/55/52 61/59/56 61/59/56 63/60/57
Type R410A
Refrigerant
Control method EXV
Notes:
Model
1. Nominal cooling capacities MDV-D200T1/N1-B
are based on the following conditions: return air MDV-D250T1/N1-B
temperature: 27°CDB, 19°CWB, and outdoor temperature:35°CDB, equivalent ref.MDV-D280T1/N1-B
piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured at 1.4m below the air out-let.
60Hz Specifications
Model DBV-DH71BG DBV-DH80BG DBV-DH90BG DBV-DH112BG
Power Supply
kW 14 16 20 25 28 40 45
ESP (external static pressure) Pa 50(50~ 196) 50(50~ 196) 200(50~280) 200(50~280) 200(50~280) 200(50~280) 200(50~280)
Sound pressure level(H/M/L) dB(A) 53/50/48 54/52/50 59/55/52 59/55/52 59/55/52 61/59/56 61/59/56
Type R410A
Refrigerant
Control method EXV
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB, outdoor temperature: 95°F(35°C)DB, equivalent ref. piping:
26.25ft.(8m)(horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB, 42.8°F(6°C)WB,equivalent ref. piping:
26.25ft.(8m)(horizontal).
3. Sound level is measured at 4.59ft.(1.4m) below the air outlet.
External static pressure is based on high speed indoor air flow.
4. MDV-D200T1/N1-B, MDV-D250T1/N1-B, MDV-D280T1/N1-B can be customized.
Outdoor Units
50Hz Specifications
Model
Model DBV-FA125AG DBV-FA140AG DBV-FA200AG DBV-FA250AG DBV-FA280AG
60Hz Specifications
Model DBV-FA125BG DBV-FA140BG DBV-FA200BG DBV-FA250BG DBV-FA280BG
kW 12.5 14 20 25 28
Type R410A
Refrigerant
Control method EXV
56-1/8×19-11/16×36-17/32 56-1/8×19-11/16×36-17/32
47-1/4×15-3/4×23-5/8 47-1/4×15-3/4×23-5/8 56-1/8×19-11/16×36-17/32
Net dimension W×H×D mm 1300×420×690 (1,425×500×928)
1443×470×810 (1,425×500×928)
(1,200×400×600) (1,200×400×600) (1,425×500×928)
59-13/32×20-9/16×37-31/32 59-13/32×20-9/16×37-31/32
56-5/16×17-23/32×30-1/4 56-5/16×17-23/32×30-1/4 59-13/32×20-9/16×37-31/32
Packing dimension W×H×D mm 1,436×450×768 (1,509×522×964) (1,509×522×964)
1,509×550×990 (1,509×522×964)
(1,430×450×768) (1,430×450×768)
Net/Gross weight kg 69.5/76 69.5/76 114/124 114/124 114/124
Convenient installation
The unit even can be easily installed at the corner of a narrow
ceilings.
It is especially useful when central installation is impossible due to
features such as lights.
>20
Drop ceiling
The slim and sleek design starting at just
30kg enables quick, easy and neat
198mm installation.
Low noise operations; minimum 36 dB(A)
Air Outlet
1.Auto horizontal and auto vertical swing functions for more even and comfortable
airflow.
2.Three air flow speeds: low, medium and high; double air guides.
3.Adopt electrical expansion valve, ensuring precise flow control, lower modulation
noise when EXV operating.
4.Smoother airflow and less turbulence due to the multi-blade fan and the air guide
design.
50Hz Specifications
Model DBV-EA36AG DBV-EA45AG DBV-EA56AG DBV-EA71AG DBV-EA80AG
kW 10 12.5 15 18
Heating capacity kcal/h 8,600 10,800 12,900 15,500
Type R410A
Refrigerant
Control method EXV
* Specifications are subject to change without prior notice for product improvement.
60Hz Specifications
Model DBV-EA36BG DBV-EA45BG DBV-EA56BG DBV-EA71BG
Wall-mounted
Step 3
Swing 4
Convenient installation
Multi-refrigerant outlet pipe method: left\right\rear, more flexible for
installation.
The EXV is built-in the indoor unit, compact size, longer the
connection pipe; gas pipe: 468mm; liquid pipe: 550mm, more flexible
for installation. Rear
Adopts new type fixing plate, is easy to install and stable. Left Right
WC type (50hz)
Model DBV-WC15AG DBV-WC22AG DBV-WC28AG DBV-WC36AG DBV-WC45AG DBV-WC56AG
WA type (50hz)
Model DBV-WA22AG DBV-WA28AG DBV-WA36AG DBV-WA45AG DBV-WA56AG
* Specifications are subject to change without prior notice for product improvement.
WB type (50Hz)
Model DBV-WB71AG DBV-WB80AG DBV-WB90AG
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temp.: 95°F(35°C)DB,equivalent ref.
piping: 26.25ft(8m)(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 68°F(20°C)DB, outdoor temp.: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref.
Piping: 26.25ft(8m)(horizontal)
3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.
* Specifications are subject to change without prior notice for product improvement.
WA type (60Hz)
Model DBV-WA22BG DBV-WA28BG PAGE DBV-WA36BG DBV-WA45BG DBV-WA56BG
WB type (60Hz)
Model DBV-WB71BG DBV-WB80BG DBV-WB90BG
* Specifications are subject to change without prior notice for product improvement.
Console
Flexible installation
Can be installed on the floor or lower wall
As a floor standing type, it can be semi or fully accessed without losing
capacity.
High Comfort
Flexible air blow: vertical auto swing and wide angle louvers ensure that warm air reaches every corner of the room and
increases the air flow coverage.
Indoor unit adopts DC motor with five fan speeds to meet different requirements.
Applies the Fujikoki mechanical expansion valve which offers 2,000-stage element positions to ensure precise flow control
and lower modulation noise when the EXV is operating.
50Hz Specifications
Cooling 20 25 25 45
Power input W
Heating 20 25 25 45
Type R410A
Refrigerant
Control method EXV
Net weight kg 14 15 15 15
Gross weight kg 19 20 20 20
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB, 19°CWB, and outdoor temperature:35°CDB, equivalent ref. piping:
8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m
(horizontal)
3. Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance.
* Specifications are subject to change without prior notice for product improvement.
Floor Standing
Easy installation
Floor standing types can be hung on the wall or installed on the floor. The floor type of unit can make cleaning and maintenance much
easier. Running the piping from the rear allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate,
is considerably easier.
Easy maintenance
Filter is provided as a standard accessory. It can be removed and cleaned easily thanks to Dunham-Bush’s sophisticated design and
the product's removable blades.
The streamlined appearance harmonizes the unit with a given room's interior decor. All metal parts are made of commercial grade
galvanized steel for maximum protection against corrosion.
Concealed floor standing type The body is concealed in the skirting board to improve aesthetics. The body is
just 212mm deep, and can be installed at the room's perimeter. Special
installation methods eliminate noise in the room area.
C series concealed type Air intake from front(A series) Air intake from below(B series)
50Hz Specifications
Model DBV-PC22AG DBV-PC28AG DBV-PC36AG DBV-PC45AG DBV-PC56AG DBV-PC71AG DBV-PC80AG
Power supply 1-phase,220-240V,50Hz
kW 2.2 2.8 3.6 4.5 5.6 7.1 8
Cooling capacity kcal/h 1900 2400 3100 3900 4800 6100 6900
Btu/h 7500 9600 12300 15400 19100 24200 27300
kW 2.4 3.2 4 5 6.3 8 9
Heating capacity kcal/h 2100 2800 3400 4300 5400 6900 7700
Btu/h 8200 10900 13600 17100 21500 27300 30700
Cooling 40 46 46 49 88 130 130
Rated input W
Heating 40 46 46 49 88 130 130
Cooling 0.18 0.21 0.22 0.22 0.4 0.56 0.59
Rated current A
Heating 0.18 0.21 0.22 0.22 0.4 0.56 0.59
m3/h 530/456/400 569/485/421 624/522/375 660/542/440 1150/970/830 1380/1100/870 1380/1100/870
Airflow rate(H/M/L)
CFM 312/268/235 335/285/248 367/307/221 388/319/259 677/571/489 812/647/512 812/647/512
Sound pressure level ( H/M/L) dB(A) 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
Type R410A
Refrigerant
Control method EXV
Net dim.(W×H×D) 840×544×212 840×544×212 1036×544×212 1036×544×212 1336×544×212 1336×544×212 1336×544×212
mm
Indoor Unit Gross dim.(W×H×D) 939×639×305 939×639×305 1139×639×305 1139×639×305 1425×639×305 1425×639×305 1425×639×305
NetGross kg 25/27 25/27 29.5/34 29.5/34 33/39 33/39 36/40
L(flare) mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф9.53 Ф9.53 Ф9.53
Piping
connections G(flare) mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф15.9 Ф15.9 Ф15.9
Drain piping mm OD Ф16 OD Ф16 ODФ16 ODФ16 ODФ16 ODФ16 ODФ16
Standard Controller Wireless remote controller (RM05/BG(T)E-A)
HRV
Heat recovery ventilator
The heat recovery ventilator (HRV) can reclaim heat energy HRV-1500 HRV-2000
lost through ventilation and reduce the room temperature
fluctuation caused by ventilation process. By utilizing the most
advanced technology and technics, DUNHAM-BUSH HRV has
extremely good performance. The heat exchanged core is
made of special paper processed with chemical treatment,
which could realize better temperature and humidity control of
the room environment. Temperature exchange efficiency is
above 65% and enthalpy exchange efficiency between
50-65%.
EA
OA
Duct (Obtain locally)
IDU
SA RA
IDU
Centralized control
SA
CCM03
Specifications
Model HRV-200 HRV-300 HRV-400 HRV-500
Power supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 (220/1/60) 220-240/1/50 (220/1/60)
Temperature High % 55 55 55 55
exchange Medium % 55 55 55 55
efficiency Low % 60 60 60 60
Cooling
Enthalpy High % 50 50 50 50
exchange Medium % 50 50 50 50
efficiency Low % 55 55 55 55
Temperature High % 60 60 60 65
exchange Medium % 60 60 60 65
efficiency Low % 65 65 65 70
Heating
Enthalpy High % 55 55 60 60
exchange Medium % 55 55 60 60
efficiency Low % 60 60 65 65
Heat High dB(A) 27 30 32 35
exchange Medium dB(A) 26 29 31 34
Sound
mode Low dB(A) 20 23 25 28
pressure
High dB(A) 28 31 33 36
level Bypass
Medium dB(A) 27 30 32 35
mode
Low dB(A) 22 25 27 30
Net dimension (W×D×H) mm 866×655×264 944×722×270 944×927×270 1038×1026×270
Packing size (W×D×H) mm 930×730×445 1010×800×450 1010×1010×450 1120×1120×452
Net/gross weight kg 23/40 26/44 31/52 41/64
Casing Galvanized steel plate
Heat exchange system Air to air cross flow total heat (sensible heat + latent heat) exchange
Heat exchange element material Specially processed nonflammable paper
Type Centrifugal fan
High m3/h 200 300 400 500
Airflow rate Medium m3/h 200 300 400 500
Low m3/h 150 225 300 375
Fan
High Pa 75 75 80 80
ESP Medium Pa 58 60 65 68
Low Pa 35 40 43 45
Motor output W 20 40 80 120
Duct diameter mm Φ144 Φ144 Φ144 Φ194
°C -7~43 DB, 80% RH or less
Operating temperature range
°F 19.4~109.4 DB, 80% RH or less
Branch joints
Packing Size (mm)/
Model Appearance Model name Description
Gross Weight (kg)
0D:31.8 ID:31.8
0D:15.9 ID:15.9
ID:25.4 ID:34.9 0D:34.9 ID:12.7 ID:19.1 0D:19.1
Q2 Y2
OYBP-2A Q4 Q3 Y6 Y3
ID:38.1 ID:22.2
Q1 Y1 ID:15.9
ID:31.8
ID:31.8 ID:34.9 ID:15.9 ID:19.1
0D:15.9
ID:25.4 0D:31.8
ID:12.7
ID:38.1 Y1 ID:15.9
Q1 ID:31.8
ID:31.8 ID:34.9 ID:15.9
0D:15.9
ID:25.4 0D:31.8 ID:12.7
OYBP-3A
ID:38.1
ID:19.1
ID:41.3 ID:22.2 0D:22.2
Q5 Y7 Y4
ID:19.1
Y1 ID:15.9
Q1
ID:31.8 ID:15.9
ID:31.8 0D:15.9
ID:12.7
ID:25.4 0D:31.8
Q2 Y2
Y6
Q7
Q1 ID:38.1 Y1 ID:15.9
ID:31.8
ID:15.9
ID:31.8 ID:34.9 0D:15.9
ID:25.4 0D:31.8 ID:12.7
ID:19.1
ID:38.1 ID:22.2
ID:41.3
Y7
Q5
OYBP-4A Y1 ID:15.9
ID:15.9
Q1 0D:15.9
ID:31.8 ID:12.7
ID:31.8
ID:25.4 0D:31.8
ID:41.3
ID:44.5 ID:22.2
ID:25.4
Description
Q6 0D:25.4
Y8
Y5
Q1 Y1 ID:15.9
ID:31.8 ID:22.2
ID:31.8 ID:15.9
0D:15.9
ID:25.4 0D:31.8 ID:12.7
IYBP-200B
Branch model
ID:22.2
ID:19.1
ID:34.9 ID:22.2 ID:28.6 ID:15.9 ID:12.7
ID:15.9 ID:12.7
ID:34.9
AUXILIARY
ID:19.1 ID:12.7
ID:28.6 ID:19.1 ID:22.2 ID:15.9
ID:41.3 (ID:19.1) (ID:15.9)
OD:34.9
ID:22.2 (ID:19.1) (ID:15.9)
ID:41.3
ID:44.5 OD:34.9 OD:28.6 OD:22.2 OD:19.1
OD:22.2 OD:19.1
OD:28.6
Indoor branch joints
ID:38.1
OD:12.7 OD:12.7
OD:22.2 OD:19.1
OD:15.9
ID:22.2 ID:19.1 ID:9.5
ID:15.9 ID:12.7
ID:22.2 ID:19.1 ID:9.5
ID:25.4
56
PAGE
Malaysia China United Kingdom
Lot 5755-6, No.1 Dunham-Bush Road, 8 Downley Road,
Kidamai lndustrial Park, Laishan District, Havant,
Bukit Angkat, Yantai, Hampshire,
43000 Kajang, Shandong Province, England PO9 2JD
Selangor, Malaysia China 264003
Tel: +44-23-9247 7700
Tel: +603-8924 9000 Tel: +86-535-658 8999 Fax:+44-23-9245 0396
Fax:+603-8739 5020 Fax:+86-535-658 1999
Vietnam
10th Floor, Nam A Bank Tower,
201-203 Cach Mang Thang 8 Street,
District 3, Ho Chi Minh City,
Vietnam
info@dunham-bush.com
www.dunham-bush.com
The manufacturer reserves the right to change specifications without prior notice.
©Dunham-Bush. All rights reserved.
M-S-0328A-0316