Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

I

TECHNICAL SPECIFICATION
UZ 03 Annular blowout preventer
7 1/16” ÷ 13 5/8”, 210 /350/700 bar (3000/5000/10000 psi)
Page 1 of 7

The UZ 03, annular BOP’s are wellhead equipments designed to close the well and prevent free oil
well blowing that may occur when drilling and bringing in oil-and-gas wells.
For this scope, annular blowout preventers perform the following operations:
• Seal off the annulus between the casing on which they are assembled and the outside of drill
pipes, tubing and casings; the dimensional range is between 1” to 9 5/8”.
• Seal off the hole when the drilling pipes, tubing or casings are out of hole.
• Drilling pipe seal, when the operating, if the hydraulic control system is provided with own
control system.

2. Technical features:

- performance level: PR1 or PR2;


- cast alloy steel body;
- at lower side of the body, the preventer is provided with a flange end, according to API 6A;
- at the top the preventer is provided with studded flange
- annular packer is actuated by double acting hydraulic cylinders;
- the BOP design ensures the “self-packing” effect, that means the well pressure helps to the ram
sealing; After them shutting, the sealing is maintaining even if the hydraulic fluid pressure is
lost.

3. Working environment:

Depending on the working environment the, UZT 03 annular blowout preventer is manufactured
on the two following two types:

Table 1
Manufacturing
Working environment
alternative
TRIM Drilling fluids based on water or oilfield products with max. temperature 212˚ F
STANDARD (100˚ C).
TRIM Drilling fluids based on water or oilfield products with H2S content-conf.
NACE* NACE-MR-01.75-cl.a III-a, with max. temperature 212˚ F (100˚ C).
DOCUMENT CODE:
REVISION:
TECHNICAL SPECIFICATION
UZ 03 Annular blowout preventer
7 1/16” ÷ 13 5/8”, 210 /350/700 bar (3000/5000/10000 psi)
Page 2 of 7

4. UZ 03 Annular blowout preventer, main components:

Fig. 1 UZ 03, annular blowout preventer – Main components


DOCUMENT CODE:
REVISION:
TECHNICAL SPECIFICATION
UZ 03 Annular blowout preventer
7 1/16” ÷ 13 5/8”, 210 /350/700 bar (3000/5000/10000 psi)
Page 3 of 7

Table 2
Item Description
1 Body
2 Piston seal packing
3 Piston
4 Sleeve
5 Nipple
6 Bull plug
7 Piston seal packing
8 Annular packer
9 Piston seal packing
10 Lock bolt
11 Special bolt
12 Knife
13 Wear plate
14 Seal gasket
15 Bonnet
16 Intermediary ring
17 Body grease fitting
18 Screw
19 Screw
20 ” O ”-ring
21 ” O ”-ring
22 Plug
TECHNICAL SPECIFICATION
UZ 03 Annular blowout preventer
7 1/16” ÷ 13 5/8”, 210 /350/700 bar (3000/5000/10000 psi)
Page 4 of 7

5. BOP’s technical features and dimensions:

Fig. 2 Annular blowout preventer dimensions


TECHNICAL SPECIFICATION
UZ 03 Annular blowout preventer
7 1/16” ÷ 13 5/8”, 210 /350/700 bar (3000/5000/10000 psi)
Page 5 of 7

Table 3.1
Max working End connections
Size Weight
pressure Upper flange Lower flange
` bar psi Studded Flange kg Lb
7 1/16 210 3000 7 1/16”, R45 7 1/16”, R45 3259 7185
7 1/16 350 5000 7 1/16”, R46 7 1/16”, R46 3262 7191
7 1/16S 350 5000 7 1/16”, R46 7 1/16”, BX156 4280 9437
7 1/16 700 10000 7 1/6”, BX156 7 1/16”, BX156 4300 9480
9 350 5000 9”, R50 9”, R50 2672 5892
11 210 3000 11”, R53 11”, R53 2350 5180
11 350 5000 11”, R54 11”, R54 3370 7431
11S 350 5000 11” x 350, R54 11” x 700, BX158 3520 7762
13 5/8 210 3000 13 5/8”, R57 13 5/8”, R57 3545 7817
13 5/8 350 5000 13 5/8”, BX160 13 5/8”, BX160 5012 11051

Table 3.2
Dimensions
Size Max working pressure
A B C
in bar psi mm in mm in mm in
7 1/16 210 3000 1102 43.4 1020 40.1 1130 44.5
7 1/16 350 5000 1102 43.4 1020 40.1 1130 44.5
7 1/16S 350 5000 1180 46.5 1020 40.1 1223 48.1
7 1/16 700 10000 1180 46.5 1045 41.1 1223 48.1
9 350 5000 1025 40.4 958 37.7 1085 42.7
11 210 3000 1020 40.1 860 33.8 1010 39.8
11 350 5000 1104 43.5 1020 40.1 1249 49.2
11S 350 5000 1104 43.5 1020 40.1 1269 50.0
13 5/8 210 3000 1174 46.2 1106 43.5 1150 45.3
13 5/8 350 5000 1222 48.1 1137 44.8 1433 56.4

Hydraulic connection - Table 4:


Table 4
Description Size Location
Open outlet - « OPEN » 1” NPT BOP body
Close outlet - « CLOSE » 1” NPT BOP body
TECHNICAL SPECIFICATION
UZ 03 Annular blowout preventer
7 1/16” ÷ 13 5/8”, 210 /350/700 bar (3000/5000/10000 psi)
Page 6 of 7

6.

For hydraulic fluid selection, take into account the following:


• Should be used no corrosives hydraulic fluid acting, with low viscosity for normal
conditions, 60cSt below at 500C (H10…H46). For low temperatures, hydraulic fluid with
low viscosity, H10 type and freezing point as lower as possible, will be used.
• Should be used the hydraulic also additive water with emulsifying agent, corrosion inhibitor
and antifreeze solution (in low temperature operation case).
• Should be excepted the lathering, deposit, precipitation and corrosive solutions.
• When is changed the hydraulic fluid type, it should be tested the compatibility with previous
hydraulic fluid.
• The average pressure recommended to close the blowout preventer – bar (psi)

Table 5.1
Blowout preventer (size x pressure )
Sealed
7 1/16” 7 1/16” 7 1/16” x 9” x 11” x 11” x 13 5/8” 13 5/8”
diameter
x 3000 x 5000 10000 5000 psi 3000 psi 5000 psi 3000 psi 5000 psi
(in)
psi psi psi
55 55 80 85 85 70 80 100
3 1/2 (800) (800) (1160) (1230) (1230) (1020) (1160) (1450)
- 85 70 85 70 80
5 - -
(1230) (1020) (1230) (1020) (1160)
85 85 100 100 100 100 120 140
0 (total) (1250) (1250) (1450) (1450) (1450) (1450) (1740) (2000)

• Hydraulic fluid volume required to operate the blowout preventer:

Table 5.2
Max. Hydraulic fluid volume
Max.
Size working On unit piston stroke On max. piston stroke
stroke
pressure Close Open Close Open
in bar psi in mm Gal/in l/mm Gal/in l/mm Gal l Gal l
7 1/16 210 3000 5.51 140 1.37 0.24 0.81 0.14 7.53 34 4.47 20.2
7 1/16 350 5000 5.51 140 1.37 0.24 0.81 0.14 7.53 34 4.47 20.2
7 1/16 350 5000 5.51 140 1.37 0.24 0.81 0.14 7.53 34 4.47 20.2
7 1/16 700 10000 5.51 140 1.37 0.24 0.81 0.14 7.53 34 4.47 20.2
9 350 5000 5.74 146 0.90 0.20 0.81 0.14 6.32 28.6 4.47 20.2
11 210 3000 6.1 155 1.23 0.22 0.92 0.16 7.53 34.1 5.64 25.5
11 350 5000 7.28 185 1.32 0,24 0.82 0.15 9.62 43,7 6 27,1
11S 350 5000 7.28 185 1.32 0,24 0.82 0.15 9.62 43,7 6 27,1
13 5/8 210 3000 7.16 181 1.23 0.22 0.84 0.15 8.75 39.5 5.98 27
13 5/8 350 5000 9.68 246 2.57 0.21 10.34 0.19 11.62 52.5 10.34 46.7
DOCUMENT CODE:
REVISION:
TECHNICAL SPECIFICATION
UZ 03 Annular blowout preventer
7 1/16” ÷ 13 5/8”, 210 /350/700 bar (3000/5000/10000 psi)
Page 7 of 7
6.2 Closing pressures
• Max. closing pressure: 2000 psi (140 bar);
• Recommended closing pressure: 1500 psi (105 bar);
• Minimum recommended closing pressure: 1000 psi (69 bar);
• Minimum operator pressure for low pressure sealing (MOPFLPS) (no pressure in wellbore):
1450 psi (100 bar)

7. Function features:

1) Annular packer:
• Assure the sealing on the outside diameter of the drilling pipe/tubing
• Assure the complete well shut-off
2) BOP body:
• Integrate the hydraulic chamber for opening and shutting the annular packer
3) BOP bonnet:
• Allow the stroke measurement

Temperature rating for metalic materials - Table 6

Table 6
Classification Operating Range
°C °F
T-20/250 -29 to 121 -20 to 250

Temperature ratings for nonmetalic sealing materials - Table 7

Table 7
Low Temperature Limit Continuous Elevated Temperature Extreme Temperature Limit
Limita) (third digit)
(first digit) (second digit)
Code Temperature Code Temperature Code Temperature
°C °C °F °C °F
A 66 150 A 82 180
B 82 180 B 93 200
A -26 -15
C 99 210 C 104 220
D 116 240 D 121 250
a)
not required for PR1

6.2 Closing pressures


• Max. closing pressure: 2000 psi (140 bar);
• Recommended closing pressure: 1500 psi (105 bar);
• Minimum recommended closing pressure: 1000 psi (69 bar);
• Minimum operator pressure for low pressure sealing (MOPFLPS) (no pressure in wellbore):
1450 psi (100 bar)

You might also like