Professional Documents
Culture Documents
Chint Catalog
Chint Catalog
ABOUT CHINT
Founded in 1984, CHINT is a leading global provider of smart internal and external as the platform of intelligent technology
energy solutions. It is actively deploying“4+1” industrial and data application. Based on the Industrial Internet of Things
sectors including smart electrics, green energy, industrial (IIoT), CHINT built an intelligent manufacturing system and
control and automation, smart home and incubator, forming an realizes intelligent application in electrical industry. Relying on
integrated whole industry chain of “power generation, storage, the Energy Internet of Things (EIoT), CHINT built its smart
transmission, substation, distribution, sales and consumption”. energy system and develops the regional EIoT mode.
And it boasts an extensive business network across over 140
countries and regions as well as more than 30,000 employees Focusing on energy system of supply, storage, transmission,
and an annual sales revenue of over USD 11.4 billion. CHINT has distribution and consumption, CHINT has core businesses of
been ranking among China’s Top 500 companies for 18 clean energy, energy distribution, big data and energy
consecutive years. Its subsidiary, CHINT Electrics is the first value-added services. Furthermore, CHINT pillar businesses
company in China with low-voltage electrics as its main business include photovoltaic equipment, energy storage, power
getting listed on the A-share market as one of the Top 50 Asian transmission & distribution, low-voltage apparatuses, intelli-
listed companies. gent terminals, software development and control automation.
With developing into a platform-based enterprise, CHINT
To comply with the trend of integrated development of modern provides a package of energy solutions for public institutions,
energy, intelligent manufacturing and digital technology, CHINT industrial & commercial users and end users, by building a
has adopted “One Cloud & Two Nets” as the business strate- regional smart energy operation ecosphere.
gy. CHINT Cloud fulfills digital application and services in both
ONE CLOUD & TWO NETS STRATEGY
Solutions and Services for Customers Optimization for Manufacturing and Supply Chain
Energy system optimization is an inevitable trend against the As a user-centric multi-energy complementary smart energy
background of resource shortage, environmental pollution and system, CHINT EIoT provides a package of energy solutions for
climate change – three challenges faced by global energy devel- governments, industrial & commercial users and end users. Its
opment. To keep in line with the trend, CHINT actively imple- business includes Smart Energy Efficiency, Smart Power, Smart
ments the business strategy of One Cloud & Two Nets, continu- Home and Smart Clean Energy, etc.
ously promotes the deep integration of big data, IoT, AI and
manufacturing industry in stages to become a platform-based As a smart manufacturing system based on corporate digital
enterprise, and leads the new direction of industry develop- transformation, CHINT IIoT constitutes a flexible, high-efficiency
ment. and intelligent industrial system. Its business includes Intelligent
Manufacturing, Intelligent Industry, Smart Water, Smart Heating,
As a medium of smart technology and data applications, CHINT etc.
Cloud connects corporate in-house manufacturing with opera-
tion and management data, realizing digital applications and
services both internally and externally.
R&D, QUALITY, SALES, LOGISTICS
By providing reliable products and service for clients, CHINT puts forward the concept "Great Quality." Quality control and
upgrade is divided into four systems: scientific research, quality control, marketing service and logistics distribution. These methods
and strategies make a comprehensive upgrade to product quality and services. Emphasis on "prevention first, continuous
improvement" is the basis of an effective quality inspection system. Leading the management process of "Great Quality" in the
production process controls each link of production accurately and realizes the institutional operation of quality improvement.
"Great Quality" is not just a slogan, but a belief rooted in each employee's work. High-quality and accuracy are the basic requirement.
Starting from a routine operation by each staff to implementing a high-quality of production and service, CHINT is
your most reliable partner.
Service Concept
Sincerely care for customers, quality creates value
Service Purpose
Innovative and progressive, satisfying the customers
Integrated Vertical R&D Great Quality System One-stop Services 48-Hour Response
By gathering the global Ensuring flaw-fraw-free CHINT's concept is that Providing end-to-end
industry elites to Provide safe and trouble-free products, the it is not difficult to fulfill a one-stop services for custom-
and stable energy-saving green multi-dimensional and multi- high-quality logistics distribu- ers with complains, business
level control is conducted tion at one time, while it is consulting and technical
and advanced electric products. through procurement, inspec- difficult to stay as accurat e support by solving problems
tion, quality control and and prompt as the first-time. immediately and including
certification. High-efficiency and high-pre- any possible problems in
At least 5% of revenue is cision accuracy are our advance.
invested in research and requirement.
development
Low Voltage
Brief Catalogue
MCCB P-045
ACB P-055
Relay P-083
LV Capacitor P-103
NB1-63H NB1-63G
NB1-63
In: 1~63A In: 1~63A
In: 1~63A In: 1~63A
Icn=3000A,
Icn=6000A 10000A
4500A
NB8-63M
NB8-40J
In=1~63A
In=1~40A
Icu=10000A
Icn=6000A
DC MCB
MCCB
DZ158 NXB-125
In: 63A, 80A, In=63~125A
100A, 125A Icu=10000A
Icu=6kA, 10kA
RCBO
XF9 XF9J S9 V9
Auxiliary Alarm auxiliary Shunt Under-voltage
contact contact release release
OUVT-X3
Over/under
voltage release
For NXB-125,
NXBLE-125 series
Page P-035
Switch Disconnector
NZK1 NZK2
Surge Arrester
NP9 ND9
Pushbutton Indicator
light
Consumer Unit
NXW5
CBB-2
Busbar
2. Technical features
IEC/EN IEC/EN
Standard UL1077
60898-1 60947-2
3. Curve
B, C, D curve
K
RTE
TE
A A
IN
DNV
014
MCB
MCB Low
LowVoltage
VoltageBrief
BriefCatalogue
Catalogue P-004
P- 002
Rated current In A 1, 2, 3, 4, 5, 6, 10, 15, 16, 20, 25, 32, 40, 50, 63
Poles 1P, 2P, 3P, 4P
Rated voltage Ue V 230/400~240/415
Rated frequency Hz 50/60
3 (1A~63A) eBC
Rated breaking capacity kA 4.5 (1A~63A) eB
6 (B,C 1~40A) eBG
eB 3.Curve
B, C, D curve
eBG
P-005
P- 003 Low Voltage
Low VoltageBrief
BriefCatalogue
Catalogue MCB
MCB
2. Technical features
NB1-63G
Standard IEC/EN 60898-1
Rated current In A 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
Poles 1P, 2P, 3P, 4P
Rated voltage Ue V 230/400
Rated frequency Hz 50/60
Rated breaking capacity A 6000
Rated impulse withstand voltage(1.2/50) Uimp V 4000
Thermo-magnetic release characteristic B, C
Electrical life 4,000
Mechanical life 20,000
3. Curve
B, C curve
t(s)
10000
5000
2000
1000
500 B
200
100
50
20
10
5 C
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
MCB
MCB Low
LowVoltage
VoltageBrief
BriefCatalogue
Catalogue P-006
P- 004
3.Curve
B, C curve
t(s)
10000
5000
1h
2000
1000
500
200
B
100
50
20
10
5 C
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
▪ Rated short-circuit breaking capacity: 6KA
▪ Short-circuit breaking capacity: 6KA
▪ Rated impulse withstand voltage (Uimp): 4kV
P- 005 Low Voltage Brief Modular
Catalogue ▪ Protection Din Rail Product
of circuits against short-circuit currents, overload currents, switch, isolation
Electrical life: 6000 cycles (In ≤ 100A); 4000 cycles (In > 100A);
Rated short-circuit breaking capacity(Icn): 10kA;
Short-circuit breaking capacity(Ics): 7.5kA;
Rated impulse withstand voltage(Uimp): 4kV;
P- 007 Low Voltage Brief Catalogue MCB
Miniature Circuit Breaker NB8 -63
2. TECHNICAL DATA
NB8-63
1. General
1.1 Function
protection of circuits against shor t-circuit currents,
protection of circuits against overload currents, switch,
isolation. NB8 -63 circuit-breakers are used in domestic
installation, as well as in commercial and industry electrical
distribution systems.
1.2 Selection
NB8-63 Technical data of the network at the point considered:
short-circuit current at the circuit-breaker installation point,
which must always be less than the breaking capacity of this
device, network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT
systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrush
current.
D curve(10-16In)
protection for circuits which supply loads with high inrush
current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Certificate
CE
2.Technical features
3.Curve
(S)
02 CHINT
MCB Low Voltage Brief Breaker
Miniature Circuit Catalogue P- 008
NB8 -63H
2. TECHNICAL DATA
2.Technical features
3.Curve
02 CHINT
P- 009 Low Voltage Brief Catalogue MCB
NB8-63M
1. General
1.1 Function
protection of circuits against short-circuit currents, switch,
isolation. NB8 -63M circuit-breakers are used in domestic
installation, as well as in commercial and industry electrical
distribution systems.
1.2 Selection
Technical data of the network at the point considered:
NB8-63M short-circuit current at the circuit-breaker installation point,
which must always be less than the breaking capacity of this
device, network normal voltage.
Tripping curves:
C curve (6.4In-9.6In)
protection for resistive and inductive loads with low inrush
current.
D curve(9.6-14.4In)
protection for circuits which supply loads with high inrush
current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Certificate
CE
2.Technical features
3.Curve
MCB Low Voltage Brief Catalogue P- 010
NB8-40J
1. General
1.1 Function
Protection of circuits against shor t-circuit currents,
protection of circuits against overload currents, switch,
isolation. NB8 -40J circuit-breakers are used in domestic
installation, as well as in commercial and industry electrical
distribution systems.
1.2 Selection
NB8-63H
Technical data of the network at the point considered:
short-circuit current at the circuit-breaker installation point,
which must always be less than the breaking capacity of this
device, network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT
systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrush
Miniature Circuit Breaker NB8 -40J
current.
2. TECHNICAL DATA D curve(10-16In)
protection for circuits which supply loads with high inrush
current at the circuit closing
(LV/LV transformers, breakdown lamps)
1.3 Certificate
CE
2.Technical features
3.Curve
C curve(5~10In) D curve(10~16In)
P- 011 Low Voltage Brief Catalogue DC MCB MCB Low Voltage Brief Catalogue P-002
3.Curve
C curve
t(s)
10000
5000
1H
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
DC MCB Low Voltage Brief Catalogue P- 012
CB-60
DC Circuit Breaker
1. General
Compliant standards: IEC/EN 60898-2, IEC/EN60898-1,
EN60947-2
Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A,
40A, 50A, 63A
CB-60
Rated voltage: DC60/110(1P),DC80/125/220(2P);
Electromagnetic release type: B, C ;
Number of poles: 1P, 2P;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles
Rated short-circuit breaking capacity(Icn): 6kA;
CB-125
DC Circuit Breaker
1. General
Compliant standards: EN60947-2;
Rated current: 63A, 80A, 100A, 125A;
2. Technical features
DZ158
Standard IEC/EN 60947-2
Rated current In A 63, 80, 100, 125
Poles 1P, 2P, 3P, 4P
Rated voltage Ue V 230/400~240/415
Rated frequency Hz 50
Rated breaking capacity kA 6/10
Rated impulse withstand voltage(1.2/50) Uimp V 4000
Thermo-magnetic release characteristic (8-12)In
3.Curve
t(s)
10000
8000
1h (or 2h)
2000
1000
500
200
100
50
30
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 1.3 2 3 4 5 8 12 20 30 50 70 100 I/In
MCCB Low Voltage Brief Catalogue P- 014
NXB-125
1. General
Compliant standards: IEC/EN60947-2
Rated current: 63A, 80A, 100A(1P, 2P, 3P, 4P), 125A(1P, 2P);
Rated voltage: 230V ~ (1P), 400V ~ (2P, 3P, 4P);
NXB-125
Frequency: 50/60Hz
Electromagnetic release type:C: 8In, D:12In
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In ≤ 100A); 4000 cycles (In > 100A);
Rated short-circuit breaking capacity(Icu): 10kA;
Short-circuit breaking capacity(Ics): 7.5kA;
Rated impulse withstand voltage(Uimp): 4kV;
P- 015 Low Voltage Brief Catalogue RCCB
NL1
1. General
1.1 Function
Protect people against indirect contacts and additional
protection against direct contacts. Protect installations
against fire hazard due to insulation faults. Residual current
circuit breakers are used in housing, tertiary sector and
industry.
NL1
1.2 Detectable wave form
AC class
Tripping is ensured for slowly increasing sinusoidal AC
residual currents.
A class
Tripping is ensured for sinusoidal AC residual currents and
for pulsed DC residual currents, whether applied suddenly
or increasing slowly.
S, G/SI class
Tripping is ensured not only for sinusoidal AC residual
currents but also for pulsed DC residual currents whether
applied suddenly or increasing slowly. S, G/SI type with
filters against spurious tripping caused by harmonics and
transient surges.
NL1
1.3 Tripping sensitivity
10mA - precision instrument leakage protection and
bathroom use.
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according
to the formula IΔn < 50/R, to provide protection against
indirect contacts;
300mA/500mA - protection against indirect contacts, as well
as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping (without time-delay).
Short time delay
It ensures any tripping at least 10ms.
Selective
It ensures total discrimination with a nonselective RCD
placed downstream With the impact of 8/20us surge 3000A,
this high immunity RCCB will still be in stable status.
2.Technical features
Rated residual making and 500 (In=25A/40A) 500 (In=25A/40A) 500 (In=25A/40A)
A 1000 (In=80A/100A) 1000(In=63A/80A/100A)
Electrical breaking capacity I △ m 630 (In=63A) 630 (In=63A) 630 (In=63A)
features
Short-circuit current Inc=I △ c A 6000/10000 10000
SCPD fuse A 10000
break time under I △ n s ≤ 0.1(Normal type), 10ms~300ms(G type). 150ms~500ms(S type)
Rated frequency Hz 50/60
Rated impulse withstand voltage(1.2/50) Uimp V 6000
Dielectric test voltage at ind. Freq. for 1 min kV 2
Pollution degree 2
RCCB Low Voltage Brief Catalogue P- 016
NXL-63
1. General
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional
protection against direct contacts.
Protect installations against fire hazard due to insulation
faults. Residual current circuit breakers are used in housing,
tertiary sector and industry.
2. Technical features
2. Technical features
NB1L
Standard IEC/EN 61009-1
Combined 1~25/6~40
MCB+add-on RCCB block 1P+N, 2P, 3P, 3P+N, 4P
Poles
Combined 1P+N, 2P
Rated voltage Ue V 230/400~240/415
Rated sensitivity I△n A 0.03, 0.1, 0.3
Rated short-circuit capacity lcn A 6,000/10,000
Break time under I△n s ≤0.1
Electrical life 2,000
Mechanical life 2,000
3. Curve
B, C curve
t(s)
10000
5000
1h
2000
1000
500
200
B
100
50
20
10
5 C
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
P- 019 Low Voltage Brief Catalogue RCBO
NB1L-40/63
1. General
▪ Protection against risk of fire
▪ Protection against risk of electric shock
▪ Protection against overload
▪ Protection against short circuit
▪ Contact position indicator
NB1L-40/63
2.Technical features
P-017 Low Voltage Brief Catalogue RCBO RCBO Low Voltage Brief Catalogue P-020
2. Technical features
NB310L (2P)
Standard IEC/EN 61009-1
Poles 2P 3PN
Thermo-magnetic release characteristic B, C
Rated current In A 6-32 6-40
Poles 2P 3P+N
Rated voltage Ue V 230/240 400
Rated sensitivity I△n A 0.03
Rated short-circuit capacity lcn A 6,000
Break time under I△n s ≤0.1
Electrical life 2,000
Mechanical life 2,000 10000
NB310L (3PN)
3. Curve
B, C curve
t(s)
10000
5000
1h
2000
1000
500
200
B
100
50
20
10
5 C
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
P- 021 Low Voltage Brief Catalogue RCBO RCBO Low Voltage Brief Catalogue P-016
2. Technical features
3. Curve
B, C curve
t(s)
10000
5000
1h
2000
1000
500
200
B
100
50
20
10
5 C
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
P-011 Low Voltage Brief Catalogue RCBO RCBO Low Voltage Brief Catalogue P-022
NB3LE
2. Technical features
3. Curve
B, C curve
t (s)
10000
5000
1h
2000
1000
500 B
200
100
50
20
10
5
C
2
1
0,5
0,2
0,1
0,05
0,02
0,01
0,005
0,002
0,001
0,5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
P- 023 Low Voltage Brief Catalogue RCBO RCBO Low Voltage Brief Catalogue P-012
NB3LEU
2. Technical features
3. Curve
B, C curve
t (s)
10000
5000
1h
2000
1000
500 B
200
100
50
20
10
5
C
2
1
0,5
0,2
0,1
0,05
0,02
0,01
0,005
0,002
0,001
0,5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
P-013 Low Voltage Brief Catalogue RCBO RCBO Low Voltage Brief Catalogue P-024
3. Curve
B, C curve
t (s)
10000
5000
1h
2000
1000
500 B
200
100
50
20
10
5
C
2
1
0,5
0,2
0,1
0,05
0,02
0,01
0,005
0,002
0,001
0,5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
P- 025 Low Voltage Brief Catalogue RCBO
Rated impulse
kV 4
withstand voltage (1.2/50)Uimp
2. Technical data
2.1 Curves
t(s) B Curve t(s) C Curve
10000 10000
5000 5000
1h 1h
2000 2000
1000 1000
500 500
200 200
100 100
50 50
20 20
10 10
5 5
2 2
1 1
0.5 0.5
0.2 0.2
0.1 0.1
0.05 0.05
0.02 0.02
0.01 0.01
0.005 0.005
0.002 0.002
0.001 0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 1/In 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 1/In
RCBO Low
RCBO LowVoltage
Voltage Brief
Brief Catalogue
Catalogue P-014
P-026
2. Technical features
3. Curve
C curve
t(s)
10000
5000
1h
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
P- 027 Low Voltage Brief Catalogue RCBO
NB8LE-63M
1. General
1.1 Function
Personnel and fire protection: Cable and line protection
against overload and short-circuits.
Selection
Rated residual operating current
I ∆ n = 30mA, additional protection in the case of direct
contact.
RCD Type
NB8LE-63M
Type A
RCD Type A is ensured for sinusoidal, alternating residual
currents as well as for pulsed DC residual currents, whether
they be quickly or slowly increase.
Tripping curves
C curve (5-10In)
protection for resistive and inductive loads with low inrush
current.
D curve(10-16In)
protection for circuits which supply loads with high inrush
current at the circuit closing
(LV/LV transformers, breakdown lamps).
2. Technical features
P-015 Low Voltage Brief Catalogue RCBO RCBO Low Voltage Brief Catalogue P-028
2. Technical features
3. Curve
Curve
t(s)
10000
8000
1h(or 2h)
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 1.3 2 3 45 8 12 20 30 50 70 100 200 I/In
P-083 Low Voltage Brief Catalogue ▪ Frequency:
Modular 50/60Hz
Din Rail Product
▪ Electromagnetic release type: C, D
NXB-125 ▪ Number of poles: 1P, 2P, 3P, 4P
P- 029 Low Voltage Brief Catalogue Modular
▪ Mechanical life:Din Rail
20000 Product
cycles
▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A)
▪ Rated short-circuit breaking capacity(Icu): 10000A
NXBLE-63Y Residual current operated circuit
▪ Short-circuit breaking capacity(Ics): 7500A
breaker
▪ Rated impulse withstand voltage(Uimp): 4kV
Modular Din Rail Product Low Voltage Brief Catalogue P-082
NXBLE-32 Residual
▪ Compliant standards: IEC61009-1 current operated circuit
▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
breaker
▪ Rated residual operating current: 0.01A, 0.03A
NXBLE-63Y NXB-125 Moulded Case Circuit Breaker
▪ Rated voltage: 240/415V
▪▪ Compliant
Frequency:standards:
50/60Hz IEC61009-1
▪▪ Rated
Electromagnetic
current: 6A, release type:20A,
10A, 16A, C, D25A, 32A
▪▪▪Rated
Compliant
Number of standards:
poles: 1P+N IEC60947-2
residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A ▪
▪ Mechanical
Rated current:
▪Rated life:63A,
20000 80A, 100A, 125A
cycles
NXBLE-32 voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P)
▪▪▪Frequency:
Rated voltage:
Electrical life: 240Vcycles
10000
50/60Hz
~ (1P), 415V ~ (2P, 3P, 4P)
▪ Rated
Frequency: 50/60Hz
▪▪ Electromagnetic
short-circuit breaking
release type:capacity(Icu):
B, C, D 4500A
▪ Electromagnetic release type: C, D 4500A
▪▪ Number
Short-circuit breaking
of poles: 1P+N, capacity(Ics):
2P, 3P, 3P+N, 4P
NXB-125 ▪ Rated
Number of poles: 1P, 2P, 3P , 4P
▪▪ Mechanical
impulse life:withstand
20000 cycles voltage(Uimp): 4kV
▪ Mechanical life: 20000 cycles
▪ Electrical life: 10000 cycles
▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A)
▪ Rated short-circuit breaking capacity(Icu): 6000A
▪ Rated short-circuit breaking capacity(Icu): 10000A
▪ Short-circuit breaking capacity(Ics): 6000A
▪ Short-circuit breaking capacity(Ics): 7500A
▪ Rated impulse withstand voltage(Uimp): 4kV
▪ Rated impulse withstand voltage(Uimp): 4kV
NXBLE-63
NXBLE-40 Residual
NXBLE-32 Residual current
Residual operated
current operated
current circuit
operated circuit
circuit
breaker
breaker
breaker
▪ Compliant standards: IEC61009-1
▪▪ Compliant
Compliant standards:
standards: IEC61009-1
IEC61009-1
▪▪ Rated
Rated current:
current: 6A,
6A, 10A,
10A, 16A,
16A, 20A,
20A, 25A,
25A, 32A,
32A, 40A,
40A 50A, 63A
▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A
▪▪ Rated
Rated residual
residual operating
operating current:
current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A ▪
0.01A, 0.03A
▪ Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A ▪
NXBLE-63 Rated
Ratedvoltage:
▪Rated voltage: 240V~ (1P+N, 2P), 415V~ (3P, 3P+N, 4P)
240/415V
NXBLE-40 voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P)
NXBLE-32 ▪▪ Frequency:
Frequency: 50/60Hz
▪ Frequency: 50/60Hz
50/60Hz
▪▪ Electromagnetic
Electromagnetic releaserelease type:
type: B,
C, C,
DD
▪ Electromagnetic release type: B, C, D
▪▪ Number
Number of
of poles:
poles: 1P+N,
1P+N 2P, 3P, 3P+N, 4P
▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P
▪▪ Mechanical
Mechanical life:life: 20000
20000 cycles
cycles
▪ Mechanical life: 20000 cycles
▪▪ Electrical
Electrical life:
life: 10000
10000 cycles
cycles
▪ Electrical life: 10000 cycles
▪▪ Rated
Rated short-circuit
short-circuit breaking
breaking capacity(Icu):
capacity(Icu): 6000A
4500A
▪ Rated short-circuit breaking capacity(Icu): 6000A
▪▪ Short-circuit
Short-circuit breaking
breaking capacity(Ics):
capacity(Ics): 6000A
4500A
▪ Short-circuit breaking capacity(Ics): 6000A
▪▪▪ Rated
Rated impulse
Rated impulse withstand
impulse withstand voltage(Uimp):
withstand voltage(Uimp): 4kV
voltage(Uimp): 4kV
4kV
NXBLE-63 NXBLE-125
Rated voltage: 240V~ Residual current
(1P+N, 2P), 415V~ (3P, 3P+N, 4P) operated circuit
▪ Frequency: 50/60Hz
breaker
▪ Electromagnetic release type: B, C, D
▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P
▪▪ Mechanical life: 20000IEC60947-2
Compliant standards: cycles
▪▪ Electrical life: 10000
Rated current: 63A, cycles
80A, 100A, 125A
▪▪ Rated
Rated short-circuit
residual operating current:
breaking 0.03A, 0.05A,
capacity(Icu): 6000A0.075A, 0.1A, 0.3A
NXBLE-125 ▪▪ Short-circuit
Rated voltage: 240V ~capacity(Ics):
breaking (1P+N, 2P), 415V ~ (3P, 3P+N, 4P)
6000A
▪▪ Rated
Frequency: 50/60Hz
impulse withstand voltage(Uimp): 4kV
▪ Electromagnetic release type: C, D
▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P
▪ Mechanical life: 20000 cycles
▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In> 100A)
▪ Rated short-circuit breaking capacity(Icu): 10000A
▪ Short-circuit breaking capacity(Ics): 7500A
▪ Rated impulse withstand voltage(Uimp): 4kV
NXBLE-40 Residual
Modular current
Din Rail Product Lowoperated circuit
Voltage Brief Catalogue P- 030
breaker
P-083 Modular Din Rail Product
Low Voltage Brief Catalogue
NXBLE-40 Residual
▪ Compliant standards: IEC60947-2 current operated circuit
▪ Rated current: 63A, 80A, 100A, 125A
breaker
▪ Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A
NXBLE-125 ▪ Rated voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P)
▪ Frequency: 50/60Hz
▪ Compliant standards: IEC61009-1
▪ Electromagnetic release type: C, D
▪ Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P
▪ Rated residual operating current: 0.01A, 0.03A
▪ Mechanical life: 20000 cycles
NXBLE-40 ▪ Rated voltage: 240/415V
▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In> 100A)
▪ Modular
Frequency: 50/60Hz Din Rail Product Low Voltage Brief Catalogue P-084
▪ Rated short-circuit breaking capacity(Icu): 10000A
▪ Electromagnetic release type: C, D
▪ Short-circuit breaking capacity(Ics): 7500A
▪ Number of poles: 1P+N
▪ Rated impulse withstand voltage(Uimp): 4kV
▪ Mechanical life: 20000 cycles
▪ Electrical life: 10000 cycles
breaker
▪ Rated short-circuit breaking capacity(Icu): 10000A
▪ Short-circuit breaking capacity(Ics): 7500A
▪ Rated impulse withstand voltage(Uimp): 4kV
▪ Compliant standards: IEC60947-2
▪ Rated current: 63A, 80A, 100A, 125A
▪ Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A
NXBLE-125 ▪ Rated voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P)
▪ Frequency: 50/60Hz
▪ Electromagnetic release type: C, D
AX-X1 Auxiliary contacts、AL-X1 Alarm
▪ Number of poles: 1P+N, 2P, 3P, 3P+N, 4P
▪ Mechanical life: 20000 cycles
auxiliary contact
▪ Electrical life: 6000 cycles (In≤100A); 4000 cycles (In> 100A)
▪ Rated short-circuit breaking capacity(Icu): 10000A
▪ Short-circuit breaking capacity(Ics): 7500A
▪ Compliant standards: IEC 60947-5-1
▪ Rated impulse withstand voltage(Uimp): 4kV
▪ Rated insulation voltage (Ui): 500V
▪ Utilization category:AC-12,DC-12
AX-X1 ▪ Rated operation current under different rated operation voltage:
AC-12:240V/6A,415V/3A;
P- 031 Accessoriesfor
Low Voltage Brief Catalogue Accessories for MCB,
MCB,RCBO
RCBO Low Voltage Brief Catalogue P-018
1. General
� General: Remote opening of the device when a voltage is applied.
� Manufactured according to IEC/EN 60947-5-1
� Rated voltage: AC/DC 24V, 48V; AC 230V, 400V
S9 � Mounted on the left of the MCBs/RCBOs.
1. General
� General: Reliable break the device in the case of a voltage drop
(between 35% and 70% of its rated value)
V9
� Manufactured according to IEC/EN 60947-5-1
� Rated voltage: AC 230V
� Mounted on the left of the MCBs/RCBOs .
P-019 Low Voltage Brief Catalogue Accessories forMCB,RCBO
Accessories for MCB, RCBOLow Voltage Brief Catalogue P-032
OVT-X1
UVT-X1
OVT-X3
P- 035 Low Voltage Brief Catalogue Switch Disconnector
UVT-X3
NXHB-125
NH2 Switch Isolation switch
Disconnector
▪ Compliant standards: IEC60947-3
1. General
▪ Rated current Ie: 20A, 32A, 40A, 63A, 80A, 100A, 125A
� Isolation
▪ Number of poles: 1P, 2P, 3P, 4P
▪� Rated
Designed match voltage
insulation DZ series
Ui:MCBs/RCBOs
500V
▪ Rated operation voltage Ue: 240V~(1P), 415V~(2P, 3P, 4P)
NXHB-125
NH2 2. Technical
▪ Operation features
performance: mechanical life of 10,000 cycles, electrical life of 3000 cycles
▪ Utilization category: AC-22A, AC-21B
▪ Manufactured according to IEC/EN 60947-3
▪ Electric ratings: 32A, 63A,100A, 125A, 230/400V~240/415V, 50/60Hz
▪ Rated short circuit breaking capacity: 20le, t=0.1s
▪ Electric life: 1500
▪ Mechanical life: 8500
▪ Connection: From top and bottom
NXHB-125
1. General
Compliant standards: IEC60947-3
Rated current Ie: 20A, 32A, 40A, 63A, 80A, 100A, 125A;
NXHB-125
Number of poles: 1P, 2P, 3P, 4P;
Rated insulation voltage Ui: 500V;
Rated operation voltage Ue: 240V~(1P), 415V~(2P, 3P, 4P);
Rated impulse withstand voltage Uimp: 6kV;
Rated short time withstand current Icw: 12 Ie, power-on time of 1s;
Rated short-circuit making capacity Icm: 20Ie, power-on time of 0.1s;
Rated making and breaking capacity: 3Ie, 1.05Ue, COSΦ=0.65;
Operation performance: mechanical life of 10,000 cycles, electrical
life of 3000 cycles; Pollution degree: Ⅱ ;
Utilization category: AC-22A, AC-21B;
Installation category: Ⅱ , Ⅲ ;
Installation: TH35-7.5 steel rail mounting, the gradient of the
mounting surface from the vertical plane should be ≤ 5° ;
Wiring: screw clamp wiring, tightening torque 3.5N·m (80A ~ 125A);
Tightening torque 2.0N·m(20A ~ 63A).
P-021
P- 037 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue Change-over Switch
Change-over Switch
NZK1
2. Technical features
▪ Poles: 1P, 2P
▪ Rated frequency: 50Hz/60Hz;
▪ Rated operating current Ie: 32A;
▪ Rated voltage Ue: 250V;
▪ Rated making and breaking capacity:
1.1Ue; 1.25Ie; COSΦ=0.3±0.05; 200 times
▪ Operational performance:
Ue0 Ie; COSΦ=0.6±0.05; 10000 times
+5%
NZK2
2. Technical features
▪ Poles: 1P, 2P
▪ Rated frequency: 50Hz/60Hz;
▪ Rated operating current Ie: 32A;
▪ Rated voltage Ue: 250V;
▪ Rated making and breaking capacity:
1.1Ue; 1.25Ie; COSΦ=0.3±0.05; 200 times
▪ Operational performance:
Ue0+5%Ie; COSΦ=0.6±0.05; 10000 times
Surge
SurgeArrester
Arrester Low Voltage
Low Voltage Brief
Brief Catalogue
Catalogue P-022
P-038
NU6-Ⅱ
Low-voltage Surge Arrester
1. General
▪ Manufactured according to IEC 61643-1, EN 61643-11
▪ Composed by two independent components
NU6-Ⅱ
▪ With remote control port
▪ Electric ratings: 230/400V, AC50/60Hz, Single-phase or 3-phase
▪ Maximum discharge current (kA): 40kA, 60kA, 100kA
▪ Max. continuous operational voltage Uc (V): 385V, 460V
NU6-Ⅲ
Low-voltage Surge Arrester
1. General
▪ Manufactured according to IEC 61643-1, EN 61643-11
▪ Composed by two independent components
NU6-Ⅲ
▪ With remote control port
▪ Electric ratings: 230V, AC50/60Hz, Single-phase
▪ Uoc (1.2/50μs)(kV): 10kV
▪ Max. continuous operational voltage Uc (V): 275V, 320V, 385V
P- 039 Low Voltage Brief Catalogue Surge Arrester
NU6-IIG
1. General
1.1 Certificates
international certificates are under proceeding.
1.2 Number of pole
1, 2, 3, 4, 1P+N, 3P+N
1.3 Electric ratings
NU6-IIG 230/400V, AC50/60Hz
1.4 Application
Protect electric system and on-loading electrical apparatus
from thunder and instantaneous over-voltage; 1.5 Standard:
IEC/EN 61643-11.
2. Technical features
Max. continuous operational Level of protection Maximum discharge current Maximum discharge current
Model
voltage Uc (V~) Up (kV) Imax (8/20μs) (kA) Imax (8/20μs) (kA)
275 1.5
320 1.6
40 20
385 1.8
440 2.0
NU6- Ⅱ G(/F) 255(NPE) 1.5
275 1.6
320 1.8
65 30
385 2.0
440 2.2
NXU-I+II
1. General
1.1 Compliant standards
IEC/EN 61643-11
1.2 Function
Protect electric system and on-loading electrical apparatus
from thunder and instantaneous over-voltage.
1.3 The product is composed of two independent components
NXU-I+II removable protective module 4 and base 2.
1.4 When the product is damaged, the part 3 will indicate;
please replace the removable protective module 4 at once
and there is no need to cutoff the circuits
1.5 The part 1 is for maximum continuous operational voltage
indication as well as avoiding replacement with wrong
module
2.Technical parameters
P-023
P- 041 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue Pushbutton &Indicator
Pushbutton & Indicator
NP9 Pushbutton
1.
1. General
General
� � For
For controlling
controlling electrical
electrical circuit
circuit either
either directly
directly or
or via
via starters,
starters, contactors,
contactors, relays
relays etc.
etc.
And
And pushbutton
pushbutton with
with lamp
lamp could
could also
also be
be used
used as
as indicator.
indicator.
NP9
NP9 2.
2. Technical
Technical features
features
� � Manufactured
Manufactured according
according to
to IEC/EN
IEC/EN 60947-5-1
60947-5-1
� � Type:
Type: Pushbutton
Pushbutton without without illuminated
illuminated lamp
lamp
Electric
Electric ratings:
ratings: 6A, 6A, 230V,
230V, AC50/60Hz
AC50/60Hz
Electric
Electric life:
life: 100,000
100,000
Mechanical
Mechanical life: life: 250,000
250,000
� � Type:
Type: Pushbutton
Pushbutton withwith illuminated
illuminated lamp
lamp
Electric
Electric ratings:
ratings: 20mA,
20mA, AC/DC
AC/DC 6.3/12/24/110/230V
6.3/12/24/110/230V
� � Assembly
Assembly of
of contact:
contact: 1N/C+2N/O,
1N/C+2N/O, 2N/C+1N/O,
2N/C+1N/O, 3N/O,
3N/O, 2N/C+2N/O
2N/C+2N/O
(Not
(Not available
available for
for illuminated
illuminated type)
type)
� � Mounting
Mounting on
on Din
Din rail
rail (TH35-7.5)
(TH35-7.5)
2.
2. Technical
Technical features
features
ND9
ND9
� � Manufactured
Manufactured according
according to
to IEC/EN
IEC/EN 60947-5-1
60947-5-1
� � Two
Two types:
types: single
single lamp
lamp &
& dual
dual lamps
lamps
� � Electric
Electric ratings:
ratings: 20mA,
20mA, AC/DC
AC/DC 6.3/12/24/110/230V
6.3/12/24/110/230V
� � Mounting
Mounting on
on Din
Din rail
rail (TH35-7.5)
(TH35-7.5)
Consumer
Consumer Unit
Unit Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue P-024
P-042
2.
2. Technical
Technical features
features
NX8
NX8
� � Manufactured
Manufactured according
according to
to IEC61439-3
IEC61439-3 (EN60670-24)
(EN60670-24)
� � Electric
Electric ratings:
ratings: up
up to
to 100A,
100A, 230V,
230V, AC50/60Hz
AC50/60Hz
� � On-load
On-load current(A):
current(A): 100/1-phase,
100/1-phase, 63/3-phase
63/3-phase
� � No.
No. of
of mounted
mounted units:
units: 5,
5, 6,
6, 8,
8, 12,
12, 15,
15, 20,
20, 24
24
� � Flush
Flush mounting
mounting
2.
2. Technical
Technical features
features
NX2
NX2
� � Manufactured
Manufactured according
according to
to IEC61439-3
IEC61439-3 (EN60670-24)
(EN60670-24)
� � Electric
Electric ratings:
ratings: up
up to
to 100A,
100A, 230V,
230V, AC50/60Hz
AC50/60Hz
� � On-load
On-load current(A):
current(A): 100/1-phase,
100/1-phase, 63/3-phase
63/3-phase
� � No.
No. of
of mounted
mounted units:
units: 8,
8, 10,
10, 14,
14, 18,
18, 28,
28, 36
36
� � Surface
Surface mounting
mounting
NXW1
NXW1
2.
2. Technical
Technical features
features
� � Manufactured
Manufactured according
according to
to IEC61439-3
IEC61439-3 (EN60670-24)
(EN60670-24)
� � Electric
Electric ratings:
ratings: up
up to
to 63A,
63A, 230V,
230V, AC50/60Hz
AC50/60Hz
� � No.
No. of
of mounted
mounted units:
units: 3,
3, 55
� � High
High protection
protection degree
degree up
up to
to Ip65
Ip65
� � Surface
Surface mounting
mounting
P-025
P- 043 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue Wall
WallMounting Enclosure, MCB Shield
Mounting Enclosure
2. Technical features
NXW5
▪ Manufactured according to IEC/EN 62208
▪ Designed for three phases circuit system
▪ Electric ratings: 220…240/380…415V, AC50/60Hz
Max. incoming current (A): 630A
▪ Protection degree: IP54
▪ Surface mounting for outdoor installation.
2. Technical features
MCB Shield
▪ Electrical ratings: up to 100A, 220...240/380...415V, AC 50/60Hz
▪ Poles of mounted units: 1P, 3P
Busbar Low
Busbar LowVoltage
VoltageBrief
Brief Catalogue
Catalogue P-026
P-044
CBB-2 Busbar
1. Main application and naming rule
� Busbar is mainly applied to low-voltage distribution equipment for assembly of 18mm
wide modularized products.
2. Operating conditions:
CBB-2 Busbar
▪ Operating temperature range: - 5℃~ + 40℃
▪ Relative air humidity in 20℃: 90%
▪ Altitude: ≤2000m
▪ Pollution degree: 2
Cost-effective model
Basic model
NM1 series
Rated current: 10A-1250A
Icu: 10KA-70KA
MCCB
MCCB Low
LowVoltage
VoltageBrief
BriefCatalogue
Catalogue P- 048
P-028
NM1
Fixed type MCCB
� Rated current from 10 to 1250A
� Employing a fixed thermal and fixed magnetic trip.
� Frames made of rigid materials of engineering plastics
� Complete range of one, two, three and four-pole version
NM1
� 4-class breaking capacity from 10kA to 70kA
� Vertical/horizontal installation
� Circuit breakers and auxiliaries comply with the following international standard:
IEC/EN 60947-1: general rules
IEC/EN 60947-2: circuit breakers
automatic control components.
� Certified for operation in pollution-degree � environments
as defined by IEC standard 60947 (industrial environments).
� Temperature range from -5� to +40�
� A complete system of add-on modules for Nm1
10
10
2 1
3
4
5
9
6 11
1 MCCB (fixed type) 4 Alarm contact 7 Extended manual operation handle 10 Short terminal cover
NXM
1. General
Standards: IEC/EN 60947-2
Frame current: 63/125/160/250/400/630/800/ 1000/1250/1600A
Rated voltage: 220/230/240;380/400/415V/500/690
NXM-250S/4300A Breaking capacity code: E, S, F, H
Complete accessories Installation method: Fixed type; plug-in
type
Number of poles: 2P, 3P, 4P
Dual insulation design –35 ℃ ~+70 ℃ operating temperature
range
tional)
hanism (optional)
optional)
(optional)
ional)
1
late (optional)
4
ease (optional)
3
(standard)
optional)
2 6
dule(optional)
mechanism (optional)
9
8
5
11
10
NM8N
1. General
Rated current from 16 to 1600A
▪ Thermal-magnetic type / Electronic type
▪ Adjustable thermal & adjustable magnetic trip
▪ 1P 2P 3P 4P available
▪ Beaking capacity up to 150kA
NM8N
▪ Ics=100%Icu(In ≤ 630A)
▪ Circuit breakers and auxiliaries comply with the following international standard:
IEC 60947-1 general rules for low-voltage switchgear and control equipment;
IEC 60947-2 low-voltage switchgear and control equipment circuit breakers;
IEC 60947-3 low-voltage switchgear and control equipment switches,
disconnectors and fuse combination appliances;
IEC 60947-4-1 Electromechanical contactors and motor starters (including motor
protectors) for low voltage switchgear and control equipment
▪ Wide temperature range from -40° C~+70° C
▪ Pollution grade: Grade 3;
▪ IP grade: IP40
Battery box
MCCB Low Voltage Brief Catalogue P- 052
NM8NL
Standards: 60947-2
Frame current: 125/250/400/630A
Rated voltage: 380/400/415, 440V
Poles: 3P,4P
NM8N DC
Standards: 60947-2
Frame current: 125/250/400/630/800/1600A
Rated voltage: 250V, 500V, 750V, 1000V
Poles: 1P, 2P, 3P, 4P
NM8N DC Installation method: Fixed type; plug-in type
-40℃ ~+70℃ operating temperature range
NM8N SD
Standards: 60947-2
Frame current: 125/250/400/800/1600A
Rated voltage: AC415/690V, DC 500/750/1000V
NM8N SD Poles: 2P, 3P, 4P
Installation method: Fixed type; plug-in type
-40℃ ~+70℃ operating temperature range
P-089
P- 053 Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue Series Automatic
Series Automatic Transfer Switching
Transfer Equipment
Switching Equipment
NA8 series
Rated current: 200-7500A
Icu: 55KA-135KA
Basic model
NA1 series
Rated current: 220A-6300A
Icu: 42KA-120KA
ACB
ACB Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue P-030
P- 058
11
7
12 8
13 9
10
14
15
3
5
2
16
6
2 Fixed type 6 Locking-device 10 Connecting-rod type mechanical interlock 14 Motor-driven energy-storage mechanism
3
16
4
5
15
6
10
14 11
13 12
1 Trademark 9 QR code
2 Secondary wiring terminal 10 Extraction draw plate (only applicable to draw-out type)
NA8
1. General
● Frame size (A): 1600, 2500, 4000, 7500
● Two kinds of breaking capacity: N, H (for 7500)
● Rated voltage Ue (VAC): 380/400/415, 690,
● Number of poles: 3 or 4 poles
● Mounting mode: draw-out type or fixed type
● Mode of connection: horizontal connection, vertical
● NA8 circuit breakers have successfully accredited
through the EMC test specified in the following
standards: IEC/ EN 60947-2
NA8
● Temperature range from -5℃ to +40℃
3
16
4
5
15
6
10
14 11
13 12
NC7 AC Contactor
▪ The NC7 series AC contactor is mainly used for remotely closing and breaking circuits,
and can be combined with an appropriate thermal overload relay to form a
electromagnetic starter so as to protect the circuits likely to be overloaded in operation;
the contact is well suited for frequently starting and controlling AC motors.
▪ Rating up to 690V, 620A, AC 50/60Hz, usage category of AC-3/400V
NC7 ▪ This product meets the standard of IEC60947-4-1
NC7
NC7 AC
AC Contactor
Contactor
▪ Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V,
380V, 415V, 440V, 480V, 500V, 600V, 660V
▪▪ Side
The NC7 seriesauxiliary
mounting AC contactor is mainly
contacts: used(1NO
NCF1-11C for remotely
& 1NC) closing and breaking circuits,
▪ The NC7 series AC contactor is mainly used for remotely closing and breaking circuits,
and mounting
▪ Top can be combined
auxiliarywith an appropriate
contacts: AX-3-20 &thermal
AX-3-02 overload relay
& AX-3-11 to form
(2NO a or 1NO & 1NC)
or 2NC
and can be combined with an appropriate thermal overload relay to form a
electromagnetic starter so as to protect
AX-3-13the circuits likely
& AX-3-31 (1NOto&be overloaded
3NC or 3NO &in1NC)
operation;
electromagnetic starter so as to protect the circuits likely to be overloaded in operation;
the contact is well suited for frequently
AX-3-40starting and controlling
& AX-3-04 & AX-3-22AC motors.
(4NO or 4NC or 2NO & 2NC)
the contact is well suited for frequently starting and controlling AC motors.
Rating
▪ Top up to 690V,
mounting time 620A, AC 50/60Hz,
delay block: usage category
F5-T (making of AC-3/400V
time delay);
▪ Rating up to 690V, 620A, AC 50/60Hz, usage category of AC-3/400V
NC7 ▪ This product meets the standardF5-D of IEC60947-4-1
(breaking time delay)
NC7 ▪ This product meets the standard of IEC60947-4-1
Coil voltage
▪ Assemble (AC):
with 24V, 36V,
Thermal 48V, 110V,
overload Relay127V,
NR2 220V, 230V,to be a DOL Starter.
(or NRE8)
▪ Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V,
▪ Assemble with another380V,one
415V,& 440V,
AX-3 & 480V,
F5 &500V,
NR2 600V, 660Vto be a Star-Delta Starter called QJX2;
(or NRE8)
380V, 415V, 440V, 480V, 500V, 600V, 660V
Side mounting
▪ Assemble with aauxiliary
current contacts: NCF1-11C
limiting block to be(1NO & 1NC)Contactor.
a Capacitor
▪ Side mounting auxiliary contacts: NCF1-11C (1NO & 1NC)
Top mounting
▪ Assemble with auxiliary contacts:
another one to beAX-3-20 & AX-3-02
a reversing contactor. & AX-3-11 (2NO or 2NC or 1NO & 1NC)
▪ Top mounting auxiliary contacts:AX-3-13AX-3-20&&AX-3-31
AX-3-02 & AX-3-11
(1NO & 3NC (2NO
or 3NO or &2NC or 1NO & 1NC)
1NC)
AX-3-13 &
AX-3-40 & AX-3-04
AX-3-31 & (1NO & 3NC
AX-3-22 or 3NO
(4NO & 1NC)
or 4NC or 2NO & 2NC)
AX-3-40 & AX-3-04
▪ Top mounting time delay block: F5-T (making time delay); & AX-3-22 (4NO or 4NC or 2NO & 2NC)
▪ Top mounting time delay block:F5-D F5-T (breaking
(making time delay);
time delay)
NC6 Contactor
▪ Assemble with Thermal overload F5-D Relay(breaking time delay)
NR2 (or NRE8) to be a DOL Starter.
▪▪ Assemble
Assemble with
with another
Thermaloneoverload
& AX-3 Relay
& F5NR2 (or (or
& NR2 NRE8) to be
NRE8) to a
beDOL Starter. Starter called QJX2;
a Star-Delta
▪▪ Assemble
Assemble with
with aanother
current one & AX-3
limiting block&to
F5be
& aNR2 (or NRE8)
Capacitor to be a Star-Delta Starter called QJX2;
Contactor.
� ▪ The NC6 Series
Assemble aMini
with anotherContactor
current is used in
limiting toremote motor (� Contactor.
4kW) control application.
▪ Assemble with one to beblock be acontactor.
a reversing Capacitor
� ▪ Rating up to 690V, 9A (AC-3). ----- (06A, 09A)
Assemble with another one to be a reversing contactor.
� Standard: IEC/EN 60947-4-1
� Two kinds of mounting available: Normal type (without pins); Pin type (with pins)
� Ambient temp: -5℃~+40℃
NC6
NC6 Contactor
� Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 400V;
NC6 Contactor
� Auxiliary contacts: NCF6-20 & NCF6-02 (2NO or 2NC)
NCF6-13 & NCF6-31 (1NO & 3NC or 3NO & 1NC)
014
� NCF6-40
The NC6 &Series Mini Contactor
NCF6-04 is used in remote motor (� 4kW) control application.
(4NO or 4NC)
The NC6
�� Assemble
Rating up Series
to Mini
690V, 9AContactor
(AC-3). is used
----- in09A)
(06A, remote motor (� 4kW) control application.
with Thermal overload Relay NR2-11.5 to be a DOL Starter.
R
Rating up IEC/EN
� Standard: to 690V,60947-4-1
9A (AC-3). ----- (06A, 09A)
Standard:
� Two IEC/EN
kinds of 60947-4-1
mounting available: Normal type (without pins); Pin type (with pins)
� Ambient
Two kindstemp:
of mounting
-5℃~+40℃ available: Normal type (without pins); Pin type (with pins)
NC6 � Coil
Ambient temp:
voltage -5℃~+40℃
(AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 400V;
NC6 � Auxiliary
Coil voltage (AC): 24V,
contacts: 36V, 48V,
NCF6-20 110V, 127V,
& NCF6-02 (2NO220V, 230V, 380V, 400V;
or 2NC)
� NCF6-13
Auxiliary & NCF6-31NCF6-20
contacts: (1NO & 3NC or 3NO(2NO
& NCF6-02 & 1NC)
or 2NC)
NCF6-40 NCF6-04 (1NO
(4NO&or3NC
4NC)or 3NO & 1NC)
014
R
� Assemble with Thermal overload Relay NR2-11.5 to be a DOL Starter.
Contactor
Contactor Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue P-032
P- 064
NC1 Contactor
� The NC1 Series Contactor is used in remote motor (� 45kW) control application.
▪ Rating up to 690V, 95A (AC-3). ----- (09A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A)
▪ Standard: IEC/EN 60947-4-1
▪ Ambient temp:-25℃~+55℃
▪ Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V,
NC1 380V, 415V, 440V, 480V, 500V, 600V, 660V
▪ Coil voltage (DC): 24V, 36V, 48V, 110V, 220;
▪ Side mounting auxiliary contacts: NCF1-11C (1NO & 1NC)
▪ Top mounting auxiliary contacts: F4-20 & F4-02 & F4-11 (2NO or 2NC or 1NO & 1NC)
F4-13 & F4-31 (1NO & 3NC or 3NO & 1NC)
014 F4-40 & F4-04 & F4-22 (4NO or 4NC or 2NO & 2NC)
▪ Top mounting time delay block: F5-T (making time delay);
R
NC1-Z(N) DP Contactor
▪ Used for long-distance circuit making and breaking
▪ Rated working voltage up to 690V, 25A and 40A (AC-3)
w/ 2 NO 2 NC main contacts
▪ Compliance standards: IEC / EN 60947-4-1
▪ Ambient air temperature: -25℃~+55℃,
NC1-Z(N) DP 24-hour average temperature not exceeding +35℃
▪ Altitude: ≤ 2000m
▪ Coil voltage: DC 48V
▪ Can form into reversible contactor with other AC contactors
NC2 Contactor
� The NC2 Series Contactor is used in remote motor (� 475kW) control application.
� Rating up to 690V, 800A (AC-3).
----- (115A,150A,185A,225A,265A,330A,400A,500A,630A,800A)
� Standard: IEC/EN 60947-4-1
� Ambient temp: -5℃~+40℃
NC2 � Coil voltage (AC): 110V, 127V, 220V, 230V, 380V, 400V;
� Top mounting auxiliary contacts: F4-20 & F4-02 & F4-11 (2NO or 2NC or 1NO & 1NC)
F4-13 & F4-31 (1NO & 3NC or 3NO & 1NC)
F4-40 & F4-04 & F4-22 (4NO or 4NC or 2NO & 2NC)�
014
NCK3 DP Contactor
� The NCK3 Series DP Contactor is used in remote motor
of air-conditioner (<60HP) control application.
� Rating up to 630V, 90A. ----- (25A, 30A, 32A, 40A, 50A, 60A, 75A, 90A)
� Standard: Ul508
� Poles: 1P+1NC, 1P+N, 2P, 3P
NCK3 � Ambient temp: -5℃~+40℃
� Coil voltage (AC): 24V, 110V,120V, 220V,240V (50/60Hz).
NCK5 DP Contactor
▪ The NCK5 series DP contactor is used for remote motor control of air-conditioner.
▪ Rating up to 600V, 40A (20A, 25A, 30A, 32A, 40A).
▪ Standard: UL/CSA 60947-4-1
▪ Poles: 3P, 4P
▪ Ambient temp.: -5℃~+40℃
NCK5 ▪ Coil voltage (AC): 24V, 36V, 48V, 110V, 120V, 220V, 208~240V, 277V, 440V, 480V (50/60Hz)
▪ Different wiring terminals for selection.
NC11 AC Contactor
▪ Standard: IEC 60947-4-1
▪ Rating current: 65A
▪ With 4NC main contacts, suitable for long-time closed applications, such as pre-pay meters.
▪ Compact design, 10% smaller than NC1-65 with same install dimension.
▪ Modular design without auxiliary contact, and can combine NCF-11C auxiliary contact module
NC11 on both sides.
▪ Suitable for screw installation and DIN rail installation.
NXC
CJ19 AC Contactor
Capacitor Switching Contactor
▪� The
The CJ19 Series AC
NC1 series Contactor is used
contactor in remote
is used capacitor
in remote (130kvar) switch
motor (≤335kW) controlapplication.
application.
▪� Rating up to 400V, 130A (AC-6b).
690V, 630A ----- (25A,
(AC-3). ------(6A, 32A,
9A, 12A,43A,
16A,63A,
18A,95A,115A,150A,170A)
22A, 25A, 32A, 38A, 40A,
� 50A,
Standard:
65A, IEC/EN
75A, 85,60947-4-1
100A, 120A, 160A, 185A, 225A, 265A, 330A, 400A, 500A, 630A)
▪� Standard: IEC/EN
Ambient temp: 60947-4-1
-5℃~+40℃
▪� Ambient temp.:
Coil voltage (AC):-35℃~+70℃
24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V,
NXC
CJ19 ▪ Coil voltage : 6A~225A: 24V, 36V,
415V, 440V, 480V,48V,
500V110V, 127V, 220V, 380V, 415V (AC)
265A~630A:
CJ19-25: 24V,
Rating 36V, 48V,
current 17A 110V, 127V, 220V, 380V, 415V (AC/DC)
(AC-6b/380V);
6A~12A (mini
Power type): 24V, 36V, capacitor�
of controlled 48V, 110V, 127V, 220V, 380V, 415V (AC)
12.5kvar.
24V, 48V,Rating
CJ19-32: 110V, 220V (DC)
current 23A (AC-6b/380V);
▪ Side mounting
Powerauxiliary contacts:
of controlled AX-3C/11
capacitor� ( for 6A~225A) & AX-3C/11B (for 265A~630A)
20kvar.
(1NO&1NC)
CJ19-43: Rating current 29A (AC-6b/380V);
▪ Top mountingPowerauxiliary contacts:
of controlled AX-3X/11
capacitor� & AX-3X/20 & AX-3X/02 (1NO&1NC or 2NO or
25kvar.
2NC)
CJ19-63: Rating current 43A (AC-6b/380V);
AX-3X/13Power
& AX-3X/31 (1NO&3NC
of controlled or 3NO&1NC)
capacitor� 33.3kvar.
AX-3X/22Rating
CJ19-95: & AX-3X/40
current & AX-3X/04
72.2A (2NO&2NC or 4NO or 4NC)
(AC-6b/400V);
AX-3M/11Power
& AX-3M/20 & AX-3M/02
of controlled (for50kvar.
capacitor� mini type, 1NO&1NC or 2NO or 2NC)
AX-3M/13 & AX-3M/31 (for mini type,
CJ19-115: Rating current 87A (AC-6b/400V); 1NO&3NC or 3NO&1NC)
AX-3M/22 & AX-3M/40 & AX-3M/04 (for mini type, 2NO&2NC or 4NO or 4NC)
Power of controlled capacitor� 60kvar.
▪ Top mounting time delay block: F5-T (making time delay) & F5-D (breaking time delay)
CJ19-150: Rating current 115A (AC-6b/400V);
▪ Assemble with Thermal Overload Relay NXR to be a DOL Starter.
Power of controlled capacitor� 80kvar.
▪ Assemble with another one to be a reversing contactor.
CJ19-170: Rating current 130A (AC-6b/400V);
Power of controlled capacitor� 90kvar.
� NR2 series thermal overload relay is used to provide overload and phase failure
protection for AC motors.
� Rating up to 690V, 630A. ----- (11.5A, 25A, 36A, 93A, 150A, 200A, 630A)
� Standard: IEC/EN 60947-4-1
� Ambient temp: -5℃~+40℃
NR2
� Assemble with Contactor NC1, NC2, NC7 to be a DOL Starter.
▪ The NQ3 Series DOL Motor Starter is used in remote motor (≤11kW)
start & control application.
▪ Rating up to 660V, 22A (AC-3). ----- (0.1~0.16A,0.16~0.25A,0.25~0.4A,0.4~0.63A,
0.63~1A,1~1.6A,1.25~2A,1.6~2.5A,2.5~4A,4~6A,5.5~8A,7~10A,9~13A,12~18A,
17~25A)
NQ3
▪ Standard: IEC/EN 60947-4-1
▪ Ambient temp: -5℃~+40℃
▪ Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V;
NQ2-5.5P: Rating current 12A (AC-3),
Motor power (start & control) ≤ 5.5kW (400V)
NQ2-11P: Rating current 22A (AC-3),
Motor power (start & control) ≤ 11kW (400V)
Note: P (with pushbutton)
-
NTB1 Circuit breaker for Equipment
� The circuit-breaker for equipment is used to in the control of the equipment for overload
function
� Rating up to AC250V, DC32V, 3A
� Standard: IEC/EN 60934, UL1077 and CSA C22.2 No.235
NTB1
Note
Control and Sign
diversity for applications
nal
P- 073
P-037 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue Pushbutton
Pushbutton
NP8 Pushbutton
▪The NP8 Series Pilot Device is used in remote circuit control and indication.
▪ Rating up to 415V, 1.9A (AC-15) or 250V, 0.27A (DC-13)
▪ Standard: IEC/EN 60947-5-1 IP65; Drill plan: Φ22mmm
▪ Electrical endurance: 1000×103 circles for Flush & mushroom head type;
NP8 100×103 circles for Flush & mushroom other head type;
▪ Ambient temp: -5℃~+40℃; Contact blocks: 3pcs (max);
▪ Illuminated: Either illuminated or Non-illuminated available.
▪ Button: Either Momentary or Maintained type available
▪ Holder: Plastic available
▪ Head available: Flush head, Mushroom head, selector switch, double-head switch, indicator
▪ Head colors available: Red Black Green Blue Yellow.
NP2 Pushbutton
▪ The NP2 Series Pilot Device is used in remote circuit control and indication.
▪ Rating up to 230V, 4.5A (AC-15) or 110V, 0.6A (DC-13)
▪ Standard: IEC/EN 60947-5-1 IP40; Drill plan: Φ22mm
▪ Electrical endurance: 500×103 circles for Flush & mushroom head type;
100×10 circles for Flush & mushroom other head type;
3
NP2
▪ Ambient temp: -5℃~+40℃; Contact blocks: 2pcs (max);
▪ Illuminated: Either illuminated or Non-illuminated available.
▪ Button: Either Momentary or Maintained type available
014
NP6 Pushbutton
▪
▪ TheThe
NP6NP6 Series
Series Pilot
Pilot Device
Device is used
is used in remote
in remote circuit
circuit control
control andand indication.
indication.
▪ Rating up to 220V, 0.5A (AC-15) or 220V, 0.1A (DC-13)
▪ Standard: IEC/EN 60947-5-1
▪ IP40; Drill plan: Φ16mm
▪ Electrical endurance: 500×10 circles for Flush & mushroom head type;
3
NP6
100×10 circles for Flush & mushroom other head type;
3
NP3 Pushbutton
▪ The NP3 Series Pilot Device is used in remote circuit control.
▪ Rating up to AC 380V or DC 220V
▪ Standard: IEC/EN 60947-5-1
▪ IP65;
▪ Electrical endurance: 500 ×103 circles for Flush & mushroom head type;
NP3 ▪ Ambient temp: -5℃~+40℃
▪ Button: Momentary type available
NP3-1 (↑, ↓); ↑ Up ↓ Down
NP3-1A (ON/OFF ,↑,↓) ← Left → Right
NP3-1K (ON/Emergency Stop ,↑, ↓); ≮ Front ≯ Back
NP3-2 (↑, ↓, ←, →); ∩ Clock-wise ∪ Anti-clock wise
NP3-2A (ON/OFF ,↑, ↓←, → ) ∽ Slow ≌ Fast
NP3-2K (ON,/Emergency Stop, ↑, ↓←, →);
NP3-3 (↑,↓,←, →, ≮, ≯);
NP3-3A (ON/OFF , ↑,↓←, →, ≮,≯ )
NP3-3K (ON/Emergency Stop,↑,↓,←,→, ≮, ≯);
NP3-4 (↑,↓,←, →, ≮, ≯,∩,∪);
NP3-4A (ON/OFF, ↑,↓←,→, ≮, ≯, ∩, ∪)
NP3-4K (ON/Emergency Stop ,↑, ↓,
←, →, ≮, ≯, ∩, ∪);
NP3-4 (↑, ↓, ←, →, ≮, ≯, ∩, ∪, ∽, ≌)
P- 075
P-039 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue Pushbutton
Pushbutton
▪ The NPH1 Series Pushbutton enclosure is designed for NP8 Series Pushbutton.
▪ Rating up to AC 415V or DC 250V;
▪ Standard: IEC/EN 60947-5-1 IP65;
▪ Electrical endurance: 500×103 circles for Flush & mushroom head type;
100 ×10 circles for Flush & mushroom other head type;
3
ND16 Buzzer
▪ Rating up to AC/DC 110V, AC 380V
▪ IP20
▪ ND16-22F, ND16-22FS
▪ ND16-22L, ND16-22LC
▪ Head colors: Red Black
ND16
Pushbutton
Inverter Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue P- 076
P-040
Note
NVF2G Inverter
NVF300M Inverter
▪ NVF300M mini type inverter with compact dimension
▪ Flux vector control can provide high speed precision,wide speed range,high start torque
and good reliability
▪ PID control,wobble frequency control,preset speed function
▪ Single phase and Three phase input
NVF300M
NVF3 Inverter
▪ Use of advanced high-precision flux vector control technology to achieve precise and smooth
starting of motor
▪ Good environmental adaptability, allowing the voltage fluctuation range of - 15%,~+10%
Circuit board with conformal coating
▪ Starting torque: 0.5Hz/180% rated torque
NVF3 ▪ Speed range: 1:100 (control without PG); 1:1000 (control with PG)
▪ High-speed pulse input and pulse output functions, suitable for applications where precision
requirements for speed control are very high.
▪ Built in EMC,and powerful product anti-interference capability
▪ Automatic energy-saving operation, automatic current limiting, automatic voltage regulator,
PID control functions, provide better equipment protection for customers and achieve energy
saving
▪ More than 20 kinds of protection functions e.g. over-current, over-voltage,
under-voltage, overload, phase loss, and overheating
▪ Widely used in electrical drive and automation and control of papermaking, textile,water
supply, municipal administration, food and machinery.
Inverter&
Soft-Starter
Energy Saving and
Efficiency Improving
P- 079 Low Voltage Brief Catalogue Inverter Inverter Low Voltage Brief Catalogue P-040
NVF2G Inverter
NVF300M Inverter
▪ NVF300M mini type inverter with compact dimension
▪ Flux vector control can provide high speed precision,wide speed range,high start torque
and good reliability
▪ PID control,wobble frequency control,preset speed function
▪ Single phase and Three phase input
NVF300M
NVF3 Inverter
▪ Use of advanced high-precision flux vector control technology to achieve precise and smooth
starting of motor
▪ Good environmental adaptability, allowing the voltage fluctuation range of - 15%,~+10%
Circuit board with conformal coating
▪ Starting torque: 0.5Hz/180% rated torque
NVF3 ▪ Speed range: 1:100 (control without PG); 1:1000 (control with PG)
▪ High-speed pulse input and pulse output functions, suitable for applications where precision
requirements for speed control are very high.
▪ Built in EMC,and powerful product anti-interference capability
▪ Automatic energy-saving operation, automatic current limiting, automatic voltage regulator,
PID control functions, provide better equipment protection for customers and achieve energy
saving
▪ More than 20 kinds of protection functions e.g. over-current, over-voltage,
under-voltage, overload, phase loss, and overheating
▪ Widely used in electrical drive and automation and control of papermaking, textile,water
supply, municipal administration, food and machinery.
P-091 Low Voltage Brief Catalogue Inverter Inverter Low Voltage Brief Catalogue P- 080
NJR2-T Soft-starter
▪ Three-phase 220V voltage class, dual CPU control, smooth starting and stopping
▪ Built-in with multiple protection features, perfect protection for soft starting of the motor
▪ Product specifications covering 7.5kW-160kW (squirrel cage) Three-phase AC induction
motor
▪ Multiple overload curves in line with national standards, better overload protection
NJR2-T
▪ Widely used in electrical drive equipment in many fields
▪ Ideal replacement for traditional star-delta starters, and auto voltage starting
▪ Starting current: 0.5-5 times the starting current limit.
▪ Kickstart time: 0.1S
NJR2-D Soft-starter
▪ Three-phase 380V voltage class, dual-CPU control, smooth starting and stopping
▪ All-aluminum design patents, good heat dissipation
▪ 75kW or less full-aluminum design, the radiator and shell in one, increased heat dissipation
area
▪ Powerful starting function and perfect protection function:
NJR2-D
Built-in 6 kinds of starting modes, adaptable to loads of different occasions
Built-in with multiple protection features, perfect protection on motor and soft starting
Multiple overload curves in line with national standards for, better overloading protection
▪ RS485 communication (external communication module) function, facilitating networking
control and automated transformation
Note
NJB1-YW Floatless Relay
▪
NJB1-X
The relay with the true effective value of three phase AC voltatage provides more
reliable operating protection. The products meet the requirements of
standard IEC 60947-5-1.
▪ The relay with the true effective value of three phase AC voltatage provides more
reliable operating protection. The products meet the requirements of
standard IEC 60947-5-1.
NXC AC Contactor
NJBK2 Motor Protection Relay
▪ The▪ NC1
NJBK2series ACmotor
series contactor is usedrelay
protection in remote motorreferred
(hereinafter (≤335kW)to control application.
protector as simply) is
▪ Rating up to 690V, 630A (AC-3). ------(6A, 9A, 12A, 16A, 18A, 22A,
applicable for overload, locked-rotor, phase-failure, three phase current 25A, 32A,unbalance,
38A, 40A,
50A,earthing
65A, 75A, 85, 100A, 120A, 160A, 185A, 225A, 265A, 330A, 400A,
and PTC temperature protection of AC motor @ A.C.50Hz, less than 690V500A, 630A)
▪ Standard:
rated IEC/EN
insulation 60947-4-1
voltage and 1A ~ 800A rated operating current for its continuous
▪ Ambient temp.:
working -35℃~+70℃ working.
or discontinuous
NXC ▪ Coil▪ This
voltage : 6A~225A:
product meets the 24V, 36V, 48V, 110V,
requirements 127V,
of IEC 220V,4-1
60947- 380V, 415V (AC)
NJBK2
265A~630A: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC/DC)
6A~12A (mini type): 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
24V, 48V, 110V, 220V (DC)
▪ Side mounting auxiliary contacts: AX-3C/11 ( for 6A~225A) & AX-3C/11B (for 265A~630A)
(1NO&1NC)
NJBK5 Motor Controller
▪ Top mounting auxiliary contacts: AX-3X/11 & AX-3X/20 & AX-3X/02 (1NO&1NC or 2NO or
2NC)
AX-3X/13
▪ NJBK5&seriesAX-3X/31
motor (1NO&3NC
controller or 3NO&1NC)
(hereinafter referred to as controller) is mainly used in
AX-3X/22
circuits&with
AX-3X/40 & AX-3X/04
a frequency (2NO&2NC
of AC 50Hz or 4NO
(or 60Hz), or 4NC)
a rated operational voltage of up to
AX-3M/11 & AX-3M/20
380V and & AX-3M/02
a rated control power (for
of upmini type, (current
to 11kW 1NO&1NC upor to 2NO
22A) or
to 2NC)
control the
AX-3M/13
direct & AX-3M/31
start and stop(forof mini
watertype,
pumps 1NO&3NC or 3NO&1NC)
or motors, provide motors with overload and
AX-3M/22
phase & AX-3M/40
failure & AX-3M/04
protection, and realize(forautomatic
mini type,liquid
2NO&2NC or 4NO
level control fororcivil
4NC)water towers
NJBK5 ▪ Top mounting time delay block: F5-T (making time delay) & F5-D (breaking time delay)
and reservoirs.
▪ Assemble with Thermal
▪ This product Overload Relay
is not applicable to theNXR to level
liquid be a control
DOL Starter.
of low-conductivity liquids,
▪ Assemble
such as with
oil,another
purifiedone to inflammable
water, be a reversing contactor.
and explosive chemical liquids and high-
density sewage.
▪ Standards: IEC 60947-4-1.
NXRC Contactor
NXR Thermal Relay Relay
Overload
▪▪ The
The NXR
NXRCseries
seriesthermal
contactor relay isrelay
overload usedisin relaytocontrol,
used providesignal transmission
overload and phaseand isolation
failure protection
amplifier application.
for AC motors.
▪▪ Rating
Rating up
up toto 690V,
690V, 630A
Ith=10A, 380V/1.5A
(AC-3): ------ for
(12AAC-15 andtype,
for mini 220V/0.3A for DC-13
25A, 38A, 100A, 200A, 630A)
▪▪ NXR-200
Contact combination: 4NO or 3NO&1NC or
and NXR-630 are electronic overload relay. 2NO&2NC or 1NO&3NC or 4NC
▪▪ Standard:
Standard: IEC/EN
IEC/EN 60947-5-1
60947-5-1
NXRC
NXR ▪▪ Ambient
Ambient temp.:
temp.: -35℃~+70℃
-35℃~+70℃
▪▪ Assemble
Coil voltage
with NXC36V,
: 24V, 48V, 110V,
contactor to be 127V,
a DOL220V, 380V, 415V (AC)
starter.
24V, 48V, 110V, 220V (DC)
Motor Control
▪ Top mounting auxiliary&contacts:
Protection Low Voltage Brief Catalogue P-088
AX-3M/11 & AX-3M/20 & AX-3M/02 (1NO&1NC or 2NO or 2NC)
AX-3M/13 & AX-3M/31 (1NO&3NC or 3NO&1NC)
AX-3M/22 & AX-3M/40 & AX-3M/04 (2NO&2NC or 4NO or 4NC)
JD-5E
JD-5EIntegrated
IntegratedMotor
MotorProtector
Protector
▪ ▪ JD-5E
JD-5E
Integrated
Integrated
Motor
Motor
protector
protector
(hereinafter
(hereinafter
referred
referred
toto
asas
protector)
protector)
is applicable
is applicable
for
foroverload
overloadand
andphase-failure
phase-failureprotection
protectionofofAC
ACmotor
motor@A.C.50Hz,
@A.C.50Hz,less lessthan
thanAC690V
AC690V
rated
ratedinsulation
insulationvoltage
voltageand
and1A-400A
1A-400Arated
ratedoperating
operatingcurrent
currentfor
forits
itscontinuous
continuous
working
workingorordiscontinuous
discontinuousworking.
working.Protector
Protectorand
andAC
ACcontactor
contactorare
aregenerally
generallyused
used
cooperatively.
cooperatively.
JD-5E
JD-5E
▪ ▪This
Thisproduct
productmeets
meetsthe
therequirements
requirementsofofIEC
IEC60947-4-1.
60947-4-1.
JD-5
JD-5Integrated
IntegratedMotor
MotorProtector
Protector
▪ ▪ JD-5
JD-5
Integrated
Integrated
Motor
Motor
Protector
Protector
(hereinafter
(hereinafter
referred
referred
to to
as as
protector)
protector)
is applicable
is applicable
forfor
overload
overloadand
andphase-failure
phase-failureprotection
protectionofofACACmotor
motor@@A.C.50Hz,
A.C.50Hz,less
lessthan
thanAC690V
AC690V
rated
ratedinsulation
insulationvoltage
voltageand
and0.5A~400A
0.5A~400Aratedratedoperating
operatingcurrent
currentfor
forits
itscontinuous
continuous
working
workingorordiscontinuous
discontinuousworking.
working.Protector
ProtectorandandAC
ACcontactor
contactorare
aregenerally
generallyused
used
cooperatively.
cooperatively.
JD-5
JD-5
▪ ▪This
Thisproduct
productmeets
meetsthe
therequirements
requirementsofofIEC
IEC60947-
60947-4-1.
4-1.
JD-8
JD-8Integrated
IntegratedMotor
MotorProtector
Protector
▪ ▪JD-8
JD-8Integrated
IntegratedMotor
Motorprotector
protector(hereinafter
(hereinafterreferred
referredto
toas
asprotector)
protector)isisapplicable
applicablefor
for
overload
overloadandandphase-failure
phase-failureprotection
protectionofofAC
ACmotor
motor@A.C.50Hz,
@A.C.50Hz,less
lessthan
thanAC690V
AC690V
rated
ratedinsulation
insulationvoltage
voltageand
and0.5A-160A
0.5A-160Arated
ratedoperating
operatingcurrent
currentfor
forits
itscontinuous
continuous
working
workingor ordiscontinuous
discontinuousworking.
working.Protector
Protectorand
andAC
ACcontactor
contactorare
aregenerally
generallyused
used
cooperatively.
cooperatively.
JD-8
JD-8 ▪ ▪This
Thisproduct
productmeets
meetsthe
therequirements
requirementsofofIEC
IEC60947-4-1.
60947-4-1.
Protection
Protection Relay
Relay Low
Protection Relay Low Voltage
LowVoltage Brief
VoltageBrief Catalogue
Catalogue P-046
BriefCatalogue P-046
P- 090
NJYB3
NJYB3Relay
Relay
▪ ▪NJYB3
NJYB3relay
relayisisused
usedto
toprovide
provideovervoltage,
overvoltage,undervoltage,
undervoltage,phase
phasefailure,
failure,phase
phasesequence
sequence
and
andthree-phase
three-phaseunbalance
unbalancecontrol
controlininthree-phase
three-phasethree-wire
three-wire380V
380Vcircuits
circuitsand
andthree-
three-
phase
phasefour-wire
four-wire220V220Vcircuits
circuitswith
withaafrequency
frequencyofofAC
AC50Hz(or
50Hz(or60Hz).
60Hz).For
Forexample,
example,ititisis
used
usedfor
forpower
powercontrol
controlsystems,
systems,air
airconditioning
conditioningsystems
systemsand
andmotors.
motors.
NJYB3
NJYB3
NJYB1
NJYB1Voltage
VoltageProtection
ProtectionRelay
Relay
▪
▪ ThisThis
product
product
is used
is used
in AC
in 50Hz
AC 50Hz
three-phase
three-phase
fourfour
wirewire
220V220V
circuit.
circuit.
▪ ▪ItItcan
candetect
detectfault
faultstate
stateas
asovervoltage,
overvoltage,undervoltage,
undervoltage,phase-failure
phase-failureand
andphase-
phase-
sequence
sequencethrough
throughadvanced
advancedelectronic
electroniccircuit
circuitcheck,
check,and
andprovide
providereliable
reliableprotection.
protection.
NJYB1
NJYB1
XJ3
XJ3Phase-Failure
Phase-Failureand
and
Phase-Sequence
Phase-SequenceProtective
ProtectiveRelay
Relay
▪
▪ XJ3XJ3
series
series
phase
phase
failure
failure
andand
phase
phase
sequence
sequence
protection
protection
relay
relay
is used
is used
to provide
to provide
overvoltage,
overvoltage,undervoltage
undervoltageand andphase
phasefailure
failureprotection
protectionininthree-phase
three-phaseAC ACcircuits
circuits
and
andphase
phasesequence
sequenceprotection
protectionininirreversible
irreversibletransmission
transmissiondevices
devicesand andfeatures
features
XJ3
XJ3 reliable
reliableperformance,
performance,wide wideapplication
applicationand andconvenient
convenientuse. use.
▪ ▪The
Theprotector
protectorstarts
startsto
tofunction
functionwhen
whenititisisconnected
connectedto tothe
thepower
powercontrol
controlcircuit
circuitinin
accordance
accordancewith withthethedrawing.
drawing.
▪ ▪When
Whenthe thefuse
fuseofofany
anyphase
phaseofofthe
thethree-phase
three-phasecircuit
circuitisisopen
openor orwhen
whenthere
thereisisaa
phase
phasefailure
failureininthe
thepower
powersupply
supplycircuit,
circuit,the
theXJ3
XJ3operates
operatesimmediately
immediatelyto tocontrol
control
the
thecontact
contactto tocut
cutoff
offthe
thepower
powersupply
supplyofofthetheAC
ACcontactor
contactorcoilcoilofofthe
themain
maincircuit
circuit
so
sothat
thatthe
themain
maincontact
contactofofthe
theACACcontactor
contactoroperates
operatesto toprovide
providethe theload
loadwith
with
phase
phasefailure
failureprotection.
protection.
▪ ▪When
Whenthe thephases
phasesofofaathree-phase
three-phaseirreversible
irreversibledevice
devicewith
withpredetermined
predeterminedphase phase
sequence
sequenceare areconnected
connectedincorrectly
incorrectlyduedueto tomaintenance
maintenanceor orchange
changeofofthethepower
power
supply
supplycircuit,
circuit,the
theXJ3
XJ3series
serieswill
willidentify
identifythethephase
phasesequence,
sequence,stop stopsupplying
supplyingpower
power
to
tothe
thepower
powersupply
supplycircuit
circuitand
andachieve
achievethethegoal
goalofofprotecting
protectingthe thedevice.
device.
P-047
P-047
P- 091 Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue Control Relay
Control
Control Relay
Relay
NJS1-H
NJS1-H Time
Time Delay
Delay Relay
Relay
▪▪ NJS1-H
NJS1-H series
series time
time delay
delay relay
relay (hereinafter
(hereinafter referred
referred to
to as
as relay)
relay) isis used
used as
as aa time
time control
control
element
element inin control
control circuits
circuits with
with an
an AC
AC voltage
voltage of
of 240V
240V or or below
below and and aa frequency
frequency of of
50Hz/60Hz
50Hz/60Hz and and control
control circuits
circuits with
with aa DC
DC voltage
voltage of
of 240V
240V or or below
below to to make
make andand break
break
the
the circuit
circuit according
according to to the
the schedule.
schedule.
NJS1-H
NJS1-H
NJS1-M
NJS1-M Time
Time Delay
Delay Relay
Relay
▪▪ NJS1-M
NJS1-M Series
Series Time
Time Relay
Relay isis applicable
applicable forfor controlling
controlling circuit
circuit @
@ A.C.
A.C. 50Hz/60Hz,
50Hz/60Hz,
up
up to
to 240V
240V rated
rated supply
supply voltage
voltage andand up
up to to D.C.
D.C. 240V
240V rated
rated supply
supply voltage
voltage as
as
delay
delay element
element to
to make
make or
or break
break circuit
circuit according
according to to preset
preset time.
time.
NJS1-M
NJS1-M
NJS1
NJS1 Time
Time Delay
Delay Relay
Relay
▪▪ NJS1
NJS1 Series
Series Time-Delay
Time-Delay Relay
Relay isis applicable
applicable for
for controlling
controlling circuit
circuit @
@ A.C.
A.C. 50Hz/60Hz,
50Hz/60Hz,
up
up to
to 380V
380V rated
rated voltage
voltage or
or up
up toto D.C.240V
D.C.240V rated
rated voltage
voltage as
as delay
delay element
element to
to make
make
or
or break
break circuit
circuit according
according to
to preset
preset time.
time.
NJS1
NJS1
NJS5
NJS5 Time
Time Delay
Delay Relay
Relay
▪▪ NJS5
NJS5 series
series time
time relay
relay mainly
mainly used
used as
as time
time control
control component
component for
for control
control circuit
circuit with
with
ACAC 50Hz/60Hz,
50Hz/60Hz, rated
rated control
control power
power supply
supply voltage
voltage to
to 400V,make
400V,make or
or break
break the
the circuit
circuit
atat aa preset
preset time.
time.
▪▪ Indication
Indication of of operational
operational states
states with
with LEDs.
LEDs.
▪▪ DIN
DIN rail
rail mounting
mounting andand compact
compact 1818 mm
mm design.
design.
NJS5
NJS5
Control Relay
Control
Control Relay
Relay Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue P-048
P-048
P- 092
NJS5-M2
NJS5-M2 time
time relay
relay
▪▪ Standards
Standards compliant:
compliant: GB GB 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Rated
Rated control
control supply
supply voltage:
voltage:
AC110V,
AC110V, AC220V,
AC220V, AC230V,
AC230V, AC240V,
AC240V,
AC380V,
AC380V, AC400V,
AC400V, DC24V
DC24V
▪▪ Delay
Delay range:1s~100h,7
range:1s~100h,7 adjustable
adjustable gears
gears
NJS5-M2
NJS5-M2 ▪▪ Delay
Delay function:
function: on-delay,
on-delay, off-delay,
off-delay, interval
interval delay,
delay,
off-delay/interval
off-delay/interval delay,
delay, equal
equal period
period cyclical
cyclical delay
delay (ON
(ON start),
start),
equal
equal period
period cyclical
cyclical delay
delay (OFF
(OFF start),
start), Trigger/interval
Trigger/interval delay,
delay, 77 adjustable
adjustable gears
gears
77 adjustable
adjustable gears
gears
▪▪ Dual
Dual LED
LED indicator
indicator (Power
(Power indicator
indicator and
and action
action indicator)
indicator)
▪▪ 18mm
18mm modularized
modularized design,
design, can
can be
be installed
installed toto distribution
distribution box
box
NJS3
NJS3 Time
Time Delay
Delay Relay
Relay
▪▪ NJS3
NJS3 series
series time
time relay
relay mainly
mainly used
used as
as time
time control
control component
component for
for control
control circuit
circuit with
with
AC
AC 50Hz/60Hz,
50Hz/60Hz, rated
rated control
control power
power supply
supply voltage
voltage to
to 220V,make
220V,make or
or break
break the
the circuit
circuit
at
at aa preset
preset time.
time.
▪▪ DIN
DIN rail
rail mounting
mounting andand compact
compact 1818 mm
mm design.
design.
NJS3
NJS3
NTE8
NTE8 Time
Time Delay
Delay Relay
Relay
▪▪ NTE8
NTE8 Series
Series time
time delay
delay relay
relay isis applicable
applicable for
for controlling
controlling circuit
circuit @AC
@AC 50Hz/60Hz,
50Hz/60Hz,
up
up to
to 230V
230V rated
rated voltage
voltage oror up
up to to DC
DC 24V
24V rated
rated voltage
voltage asas delay
delay element
element to
to make
make
or
or break
break circuit
circuit according
according toto preset
preset time.
time.
▪▪ This
This product
product meets
meets the
the requirements
requirements of of IEC60947-5-1.
IEC60947-5-1.
NTE8
NTE8
P-049
P- 093 Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue Control Relay
Control Relay
▪▪ JSS48A
JSS48A Time
Time Delay
Delay Relay
Relay is
is applicable
applicable for
for controlling
controlling circuit
circuit @
@ A.C.
A.C. 50Hz/60Hz,
50Hz/60Hz,
up
up to
to 380V
380V rated
rated control
control supply
supply voltage
voltage and
and up
up to
to D.C.
D.C. 240V
240V rated
rated control
control supply
supply
voltage
voltage as
as delay
delay element
element to
to make/break
make/break circuit
circuit according
according to
to preset
preset time.
time.
JSS48A
JSS48A
JSZ3
JSZ3
JSZ6
JSZ6
NKG3
NKG3
Control Relay
Control Relay Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue P-050
P- 094
▪▪ NKG3-M
NKG3-M timetime switch
switch (hereinafter
(hereinafter referred
referred to
to as
as time
time control
control switch)
switch) is
is used
used in
in automatic
automatic
control
control circuits
circuits with
with aa frequency
frequency of
of AC
AC 50Hz
50Hz (or
(or 60Hz),
60Hz), aa rated
rated control
control supply
supply voltage
voltage
of
of up
up to
to 220V
220V andand aa rated
rated operational
operational current
current of
of 0.75A
0.75A to
to provide
provide timed
timed on-off
on-off
control
control for
for street
street lamps,
lamps, advertising
advertising lamps
lamps and
and similar
similar equipment.
equipment.
NKG3-M
NKG3-M
KG316T
KG316T Time
Time Switch
Switch
▪▪ KG316T
KG316T Time
Time Switch
Switch can
can automatically
automatically turn
turn on
on or
or turn
turn off
off power
power supply
supply of
of various
various
consumer
consumer equipments
equipments according
according to
to preset
preset time
time byby user.
user. The
The controlled
controlled objects
objects are
are
circuit
circuit equipments
equipments and
and household
household appliances
appliances such
such as as street
street lamps,
lamps, neon
neon lamps,
lamps,
advertising
advertising lamps,
lamps, manufacturing
manufacturing equipments,
equipments, broadcast
broadcast & & television
television equipments,
equipments,
etc.,
etc., which
which requires
requires turning
turning on
on and
and off
off at
at definite
definite time.
time.
KG316T
KG316T
NJJ7-H
NJJ7-H Counting
Counting Relay
Relay
▪▪ The
The NJJ7-H
NJJ7-H Series
Series Counting
Counting Relay
Relay isis used
used as
as aa counting
counting control
control element
element
▪▪ Rated
Rated operation
operation voltage:
voltage: DC24V
DC24V or or AC/DC100~240V
AC/DC100~240V
▪▪ Contact
Contact capability:
capability: AC-15
AC-15 220V/0.75A,
220V/0.75A, 380V/0.47A,
380V/0.47A, DC-13
DC-13 220V/0.27A
220V/0.27A
▪▪ Number
Number ofof counting
counting digits:
digits: 66
▪▪ Ambient
Ambient temperature:
temperature: -5℃~+40℃
-5℃~+40℃
NJJ7-H
NJJ7-H
NJJ5-J
NJJ5-J Electronic
Electronic Counter
Counter
▪▪ This
This product
product adopts
adopts microminiature
microminiature design
design and
and
isis applicable
applicable for
for counting
counting inin various
various circuits.
circuits.
▪▪ Rated
Rated voltage
voltage AC50Hz/60Hz
AC50Hz/60Hz AC/DC100V-240V,
AC/DC100V-240V, DC24V
DC24V
▪▪ Current
Current failure
failure memory:
memory: >10>10 years
years
▪▪ Power
Power consumption:
consumption: About
About 1.5VA
1.5VA
NJJ5-J
NJJ5-J ▪▪ Installation
Installation mode:
mode: Panel
Panel type
type
▪▪ Ambient
Ambient temperature:
temperature: -5℃~+40℃
-5℃~+40℃
NJJ5-L
NJJ5-L Electronic
Electronic Timer
Timer
▪▪ This
This product
product adopts
adopts microminiature
microminiature design
design and
and isis
applicable
applicable for
for accumulating
accumulating time
time in
in various
various circuits.
circuits.
NJJ5-L
NJJ5-L
Control
Control Relay
Relay Low
Control Relay LowVoltage
Low VoltageBrief
Voltage BriefCatalogue
Brief Catalogue
Catalogue P-052
P-052
P- 096
NJJ3
NJJ3 Counting
Counting Relay
Relay
▪▪ NJJ3
NJJ3 Counting
Counting Relay
Relay isis applicable
applicable for
for controlling
controlling circuit
circuit A.C.
A.C. 50Hz/60Hz,
50Hz/60Hz,
240V
240V rated
rated voltage
voltage of
of control
control power
power supply
supply and
and D.C.
D.C. 240V
240V rated
rated voltage
voltage of
of
control
control power
power supply
supply asas counting
counting or
or counting
counting control
control element.
element.
NJJ3
NJJ3
NJJ7-M
NJJ7-M Counting
Counting Relay
Relay
▪▪ The
The NJJ7-M
NJJ7-M Series
Series Counting
Counting Relay
Relay isis used
used as
as aa counting
counting control
control element
element
▪▪ Rated
Rated operation
operation voltage:
voltage: DC24V
DC24V or or AC/DC100~240V
AC/DC100~240V
▪▪ Contact
Contact capability:
capability: AC-15
AC-15 220V/0.75A,
220V/0.75A, 380V/0.47A,
380V/0.47A, DC-13
DC-13 220V/0.27A
220V/0.27A
▪▪ Number
Number of of counting
counting digits:
digits: At
At CR
CR mode,
mode, 4-digit
4-digit counting
counting relay
relay (( 4-digit
4-digit redred LED
LED isis counting
counting
value,
value, 4-digit
4-digit green
green LED
LED isis preset
preset value)
value)
NJJ7-M
NJJ7-M At
At CT
CT mode,
mode, 8-digit
8-digit reversible
reversible summation
summation counting
counting relay
relay (( greed
greed LEDLED isis low
low 4-digit,
4-digit, red
red LED
LED isis
high
high 4-digit)
4-digit)
▪▪ Ambient
Ambient temperature:
temperature: -5℃~+40℃
-5℃~+40℃
JDM15G
JDM15G Counting
Counting Relay
Relay
▪▪ JDM15G
JDM15G counting
counting relay
relay isis used
used asas aa counting
counting oror counting
counting control
control element
element
in
in control
control circuits
circuits with
with an
an AC AC frequency
frequency ofof 50Hz
50Hz oror 60Hz
60Hz andand aa rated
rated control
control
supply
supply voltage
voltage ofof up
up to
to 240V
240V andand control
control circuits
circuits with
with aa DC
DC rated
rated control
control supply
supply
voltage
voltage of
of up
up to
to 240V.
240V.
JDM15G
JDM15G
JDM1-48
JDM1-48 Counting
Counting Relay
Relay
▪▪ JDM1
JDM1 series
series counting
counting relay
relay isis used
used as
as aa counting
counting or or counting
counting control
control element
element
in
in control
control circuits
circuits with
with an
an AC
AC frequency
frequency of of 50Hz
50Hz or or 60Hz
60Hz and
and aa rated
rated control
control
supply
supply voltage
voltage ofof up
up to
to 380V
380V and and control
control circuits
circuits with
with aa DC
DC rated
rated control
control supply
supply
voltage
voltage of
of up
up to
to 240V.
240V.
JDM1-48
JDM1-48
P-053 Low Voltage Brief Catalogue Control Relay
P-053
P- 097 Low Voltage
Low Voltage Brief
Brief Catalogue Control Relay
Catalogue Control Relay
JDM3
JDM3
SC3L
SC3L
JTB-714
Control Relay
Control Relay Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue P-054
P- 098
NJA1-KG
NJA1-L
Socket
P-055
P- 099 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue General Purpose
General Purpose Relay
Relay
NJX-13FW
NJDC-12
NJDC-12 Mainature
Mainature Power
Power Relay
Relay
▪▪ 7.5A
7.5A switching
switching current
current
▪▪ Various
Various sockets
sockets available
available
▪▪ Wide
Wide range
range of
of coil
coil ratings
ratings
▪▪ Certificate:
Certificate: CE
CE
▪▪ Push-to-test
Push-to-test button
button allows
allows for
for manual
manual operation
operation of
of relay
relay without
without the
the need
need for
for coil
coil power
power
NJDC-12
NJDC-12 ▪▪ Lock-down
Lock-down doordoor holds
holds poshbutton
poshbutton and
and contacts
contacts in
in the
the operate
operate position
position when
when activated
activated
JQX-10F
JQX-10F Miniature
Miniature Power
Power Relay
Relay
▪▪ 10A
10A switching
switching current
current
▪▪ Various
Various sockets
sockets available
available
▪▪ Wide
Wide range
range of
of coil
coil ratings
ratings
▪▪ Certificate:
Certificate: CE,
CE, UL
UL
JQX-10F
JQX-10F
JTX
JTX Miniature
Miniature Power
Power Relay
Relay
▪▪ 10A
10A switching
switching current
current
▪▪ Various
Various sockets
sockets available
available
▪▪ Wide
Wide range
range of
of coil
coil ratings
ratings
▪▪ Certificate:
Certificate: CE,
CE, UL
UL
JTX
JTX
JMK
JMK Miniature
Miniature Power
Power Relay
Relay
▪▪ 10A
10A switching
switching current
current
▪▪ With
With indicator
indicator to
to be
be selected
selected
▪▪ Full
Full range
range of
of AC
AC and
and DCDC coil
coil
▪▪ Certificate:
Certificate: CE,
CE, UL
UL
JMK
JMK
P-057
P- 101 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue General Purpose
General Purpose Relay
Relay
NJX2
NJX3
Socket
▪ Various kinds of socket for different relays
Socket
GeneralPurpose
General Purpose Relay
Relay Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue P-058
P- 102
NJMC1
NJMC1
NCC2
NCC2
LV Capacitor
Safe and reliable, easy to use
P- 105
P-059 LowVoltage
Low VoltageBrief
Brief Self-heating
CatalogueSelf-heating
Catalogue Shunt
Shunt Capacitor
Capacitor
BH-0.66ⅠCurrent Transformers
▪ For busbar and cable
▪ To be used in combination,
with measurement instruments: ammeters,
watt-hour meters, measurement units, control relays, etc.
▪ Max. voltage rating Ue: 660 V
BH-0.66Ⅰ ▪ Secondary current Isn: 5A
▪ Standards: IEC 61869-2
▪ Truly realize online double-conversion, the conversion time from mains mode to battery
mode is 0 ms. Microprocessor control ensures high reliability;
▪ Input power factor correction, the output power factor is up to 0.8;
▪ Wide voltage input range 110V-300V, for use in harsh power grid environment;
HP-UPS
▪ Frequency support 50/60 Hz adaptive, efficient frequency conversion mode;
▪ Simple operation and control through LCD display, and integrate display of state of
UPS monitoring;
▪ Features small size, easy operation, high power density, strong stability, cost-effective,
wide application.
NRZ28-20
NRZ28-20Fuses
Fusesfor
forProtecting
ProtectingSolar
Solar
Photovoltaic System
Photovoltaic System
▪ ▪Standards
Standardscompliant:
compliant: GB/T
GB/T13539.6, IEC60269-6
13539.6, IEC60269-6
▪ Rated voltage not exceeding DC1000V
▪ Rated voltage not exceeding DC1000V
▪ Rated current not exceeding 20A
▪ Rated current not exceeding 20A
NRZ28-20 ▪ Rated short-circuit capacity not exceeding 20kA
NRZ28-20 ▪ Rated short-circuit capacity not exceeding 20kA
▪ Breaking range and use category: gPV type
▪ Breaking range and use category: gPV type
▪ CQC,TUV,CE and other domestic and international certification have been obtained.
▪ CQC,TUV,CE and other domestic and international certification have been obtained.
TB Terminal Blocks
▪ Standards compliant: GB/T 14048.7, IEC 60947-7-1
▪ Rated working voltage: AC 600V
▪ Rated working current: 15A-100A
▪ Conventional terminals become strips separately
▪ Screws are used for fixed installation
TB
TC Terminal Blocks
▪ Standards compliant: GB/T 14048.7, IEC 60947-7-1
▪ Rated working voltage: AC 600V
▪ Rated working current: 60A-600A
▪ Conventional terminals become strips separately
▪ Screws are used for fixed installation
TC
TH35-7.5(C45) Rail
TH35-7.5(C45)
P-073
P-073
P- 127 Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue Change-over Switch,Combination
Change-over
Change-over Switch,Combination
Switch,CombinationSwitch
Switch
Switch
LW32
LW32 Universal
Universal Change-over
Change-over Switch
Switch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15,DC-13
AC-15,DC-13
▪▪ Rated
Rated voltage:
voltage: AC-15,AC
AC-15,AC 380V
380V
DC-13,DC
DC-13,DC 220V
220V
▪▪ Rated
Rated current:
current: AC-15
AC-15 2.6A,DC-13
2.6A,DC-13 0.27A
0.27A
LW32
LW32 ▪▪ Various
Various types,
types, wide
wide range
range ofof uses
uses
▪▪ Used
Used to
to convert
convert electrical
electrical control
control circuit
circuit (can
(can also
also directly
directly control
control small
small capacity
capacity motor
motor
starting,reversible
starting,reversible conversion,
conversion, transmission
transmission etc.)
etc.)
HZ10
HZ10 Combination
Combination Switch
Switch
▪▪ Standards
Standards compliant:
compliant: GB/TGB/T 14048.3,
14048.3, IEC
IEC 60947-3
60947-3
▪▪ Use
Use category:
category: AC-22A
AC-22A AC-3 AC-3 DC-21A
DC-21A
▪▪ Rated
Rated voltage:
voltage: AC-22A
AC-22A AC-3 AC-3 380V
380V DC-21A
DC-21A 220V
220V
▪▪ Rated
Rated current:
current: AC-22A
AC-22A 10A,25A,60A,100A
10A,25A,60A,100A
DC-21A
DC-21A 10A,25A,60A,100A
10A,25A,60A,100A
HZ10
HZ10 ▪▪ Widely
Widely used
used in
in the
the field
field of
of motor,
motor, with
with good
good electric
electric stability
stability and
and thermal
thermal stability,
stability, etc.
etc.
▪▪ Infrequently
Infrequently used
used forfor manual
manual making
making andand breaking
breaking ofof the
the motor
motor circuits.
circuits.
Travel Switch
Travel
Travel Switch Low
Switch Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue P-074
P-074
P- 128
YBLX-ME
YBLX-ME Travel
Travel Switch
Switch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15
AC-15 DC-13
DC-13
▪▪ Rated
Rated voltage:
voltage: AC-15
AC-15 380V
380V DC-13
DC-13 220V
220V
▪▪ Rated
Rated current:
current: AC-15
AC-15 0.8A
0.8A DC-13
DC-13 0.16A
0.16A
▪▪ Conventional
Conventional thermal
thermal current:5A
current:5A
YBLX-ME
YBLX-ME ▪▪ Compact
Compact size,quick
size,quick action,
action, diverse
diverse operating
operating methods
methods
▪▪ Used
Used for
for the
the automatic
automatic control
control of
of machine
machine tool,
tool, limiting
limiting action
action of
of motion
motion mechanism
mechanism
and
and controlling
controlling stroke
stroke or
or program
program occasion
occasion
YBLX-WL
YBLX-WL Travel
Travel Switch
Switch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15
AC-15 DC-13
DC-13
▪▪ Rated
Rated voltage:
voltage: AC-15
AC-15 380V
380V DC-13
DC-13 220V
220V
▪▪ Rated
Rated current:
current: AC-15
AC-15 0.79A
0.79A DC-13
DC-13 0.15A
0.15A
▪▪ Conventional
Conventional thermal
thermal current:5A
current:5A
YBLX-WL
YBLX-WL ▪▪ AA variety
variety of
of operating
operating and
and installation
installation methods
methods meet
meet the
the requirements
requirements of
of various
various occasions
occasions
▪▪ Used
Used for
for the
the automatic
automatic control
control of
of machine
machine tool,
tool, limiting
limiting action
action of
of motion
motion mechanism
mechanism and
and
controlling
controlling stroke
stroke or
or program
program occasion
occasion
YBLX-CK
YBLX-CK Travel
Travel Switch
Switch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15
AC-15 DC-13
DC-13
▪▪ Protection
Protection level:
level: IP52
IP52
▪▪ Rated
Rated working
working voltage:
voltage: ACAC 380V
380V DC220V
DC220V
▪▪ Rated
Rated control
control current:
current: ACAC 0.8A
0.8A DC
DC 0.16A
0.16A
YBLX-CK
YBLX-CK ▪▪ Conventional
Conventional thermal
thermal current:
current: 5A
5A
▪▪ Used
Used for
for the
the automatic
automatic control
control of
of machine
machine tool,
tool, limiting
limiting action
action of
of motion
motion mechanism
mechanism and
and
controlling
controlling stroke
stroke oror program
program occasion
occasion
P-075
P- 129 Low
Low Voltage
Voltage Brief
Brief Catalogue
Catalogue Travel Switch
Travel Switch
YBLX-10
YBLX-10 Travel
Travel Switch
Switch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15
AC-15 DC-13
DC-13
▪▪ Rated
Rated voltage:
voltage: AC
AC 380V
380V DC DC 220V
220V
▪▪ Rated
Rated current:
current: AC
AC 0.79A
0.79A DC DC 0.091A
0.091A
▪▪ Conventional
Conventional thermal
thermal current:
current: 10A
10A
YBLX-10
YBLX-10 ▪▪ Sealing
Sealing function
function available,
available, meets
meets the
the demand
demand of of water-proof
water-proof occasions
occasions
▪▪ Used
Used to
to control
control the
the stroke
stroke occasion
occasion ofof translation
translation mechanism
mechanism ofof the
the lifting
lifting equipment
equipment
YBLX-19
YBLX-19 Travel
Travel Switch
Switch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15
AC-15 DC-13
DC-13
▪▪ Rated
Rated voltage:
voltage: ACAC 380V
380V DCDC 220V
220V
▪▪ Rated
Rated current:
current: ACAC 0.79A
0.79A DC
DC 0.1A
0.1A
▪▪ Conventional
Conventional thermal
thermal current:
current: 5A
5A
YBLX-19
YBLX-19 ▪▪ AA variety
variety of
of operating
operating methods
methods meet
meet the
the requirements
requirements of of various
various occasions
occasions
▪▪ Used
Used for
for the
the automatic
automatic control
control of
of machine
machine tool,
tool, limiting
limiting action
action of
of motion
motion mechanism
mechanism and
and
controlling stroke
controlling stroke or
or program
program occasion
occasion
P-077
P- 131 Low
Low Voltage
Low Voltage Brief
Voltage Brief Catalogue
Brief Catalogue
Catalogue FootSwitch
Foot Switch
YBLXW-5 Microswitch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15
AC-15 DC-13
DC-13
▪▪ Rated
Rated voltage:
voltage: AC
AC 380V,
380V, DC
DC 220V
220V
▪▪ Rated
Rated current:
current: AC
AC 0.79A,
0.79A, DC
DC 0.14A
0.14A
▪▪ Protection
Protection level:
level: IP52
IP52
YBLXW-5
YBLXW-5 ▪▪ Product
Product features:complete
features:complete model,
model, superior
superior performance,
performance, high high performance
performance price
price ratio,
ratio,
wide range
wide range of
of application,etc.
application,etc.
▪▪ Applications:mainly
Applications:mainly used
used for
for the
the stroke
stroke control,
control, limit
limit protection
protection and
and interlocking
interlocking of
of the
the
mechanical equipment
mechanical equipment of of machinery,
machinery, textile,
textile, light
light industry,
industry, electronic
electronic instrument
instrument
YBLXW-6 Microswitch
▪▪ Standards
Standards compliant:
compliant: GB/T
GB/T 14048.5,
14048.5, IEC
IEC 60947-5-1
60947-5-1
▪▪ Use
Use category:
category: AC-15
AC-15 DC-13
DC-13
▪▪ Rated
Rated voltage:
voltage: AC
AC 380V,
380V, DC
DC 220V
220V
▪▪ Rated
Rated current:
current: AC
AC 0.79A,
0.79A, DC
DC 0.14A
0.14A
▪▪ Protection
Protection level:
level: IP52
IP52
YBLXW-6
YBLXW-6 ▪▪ Operating
Operating frequency:
frequency: 40 40 times
times // min
min
▪▪ Product
Product features:
features: flexible
flexible action,
action, high
high reliability,
reliability, wide
wide range
range of
of application
application
▪▪ Applications:mechanical
Applications:mechanical automatic
automatic control,
control, limiting
limiting movement,
movement, action
action or
or procedure
procedure
control
control of
of transmission
transmission mechanism
mechanism
JD Electromagnetic Speed-adjustable
Motor Controller
▪▪ JD
JD electromagnetic
electromagnetic speed-adjustable
speed-adjustable motor
motor controllers
controllers are
are products
products designed
designed
jointly
jointly (uniformly)
(uniformly) nationwide
nationwide by
by the
the former
former Ministry
Ministry of
of Machinery
Machinery Industry
Industry and
and used
used for
for the
the
speed
speed control
control of
of electromagnetic
electromagnetic speed-adjustable
speed-adjustable motor
motor (slip
(slip motor)
motor) toto achieve
achieve constant
constant
JD
JD torque
torque stepless
stepless speed
speed regulation.
regulation. This
This controller
controller applies
applies only
only toto slip
slip motor,
motor, not
not to
to general
general
motor.
motor.