Adjustment method
Overvoltage
Type Setting of J108 Setting of input power
protection Factory setting
voltage
adjustment
03P9339C, D
Open 288 VAC 282 to 294 VAC
(220 VAC) Point at which CR23
For is turned on by
03P9339A, B adjusting R21
1-2, 4-7, 5-8 144 VAC 141 to 147 VAC
(100 VAC)
Jumper
Note:
When the setting of “J108” is just changed without adjustments as menteioned above,
the operating voltage of the overvoltage protection circuit does not meet the specified
value.
- 220 VAC -> 100 VAC: approximately 130 VAC.
- 100 VAC -> 220 VAC: approximately 325 VAC.
Operation without re-adjustments may result in a failure of the equipment.
2. Circuit setting
The setting of J108 is the setting of the rectifier circuit and the voltage setting of the input
overvoltage protection circuit as shown below.
Doubler Rectifier
L31
CR26
+
AC IN C31
C26 R41 L32
= 280VAC
- C32 - 310VAC
CR8 J108
C27 R42
7/8 4/5
100VAC: Short
220VAC: Open
R19
4
PW CONT
R18
U11
Q12
R21
Q11