ATTENTION: TO INSURE SAFE AND EASY USE OF YOUR NEPTUNE MIXER,

READ THESE INSTRUCTIONS BEFORE USING.

Description General Safety Information

Agitators are designed for economical mixing of closed tank. Warning: These agitators are intended for specific
The agitator can be easily mounted on top of the tank. The functions. Please follow all instructions to
agitator has easy access to dismantle and assemble after insure safe and proper use.
the service. The unit can be conveniently moved from (1) Be certain that all mounting hardware and the coupling
one tank to another. and propeller set screws are properly tightened prior to
operation.
(2) Clamp securely to tank rim. Be certain propeller
is not touching side or bottom of tank.
(3) Perform electrical connections and wiring in accordance
with the electrical area requirements and local electrical
codes.
(4) Do not attempt to adjust agitator when agitator is
operating, this could result in personal injury or damage
to the tank and agitator.
(5) Always wear required safety equipment including eye
protection when observing agitator performance or
when adding materials to a tank while the agitator is
operating.

(6) Refer motor and gearbox manual for safe operation and
maintenance.

Figure 1 – Tank with


Agitator

Unpacking

When unpacking the mixer, check carefully for


damage that may have occurred during transit.
Check for missing parts.

DOVER INDIA PVT LTD


NO:33, NH-4, Mevalurkuppam
Chennai – 600123
TEL: +91 44 6719 3000
EMAIL: sales.psgindia@psgdover.com
Assembly Instructions

Assembly and Mounting: Trouble Shooting Guide:


(1) Connect Coupling with Gear box. Problem Cause Action
(2) Connect Coupling with shaft by using set screws. Motor Will Not Power problem Check electrical
(3) Attach clamp plate with Gear Box. Start supply
(4) Connect Propeller with shaft by using set screws Defective motor Replace motor
(4) Connect Motor with Gear Box by using Keys and Motor Quits Starter tripped Reset starter
fasteners. Running out
(5) Position Agitator on the Tank. Motor burned out Replace motor
(6) Attach clamp plate on tank using required fasteners. Tripped Starter Bad heaters Replace heaters
(7) Recheck all hardware for proper tightening.
Over amp draw check amp draw
Whining Noise Check Replace
motor/Gearbox Bearings
bearings
Random Noise Contamination in Drain and
(Gearbox) oil replace oil
Rhythmic noise Possible bur on A bur on a gear
(Gearbox) gear set set tends to
correct itself over
time. If the noise
is overly
obtrusive,
remove gearbox
and return to
factory for
evaluation.
Vibration Loosened parts Tighten all
fasteners