CHINT 3 Fase 8 12 KW Datasheet

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Inverter-Asia/Europe

8/10/12kW Three Phase Grid-tied PV Inverters

Chint Power introduces three-phase 8/10/12kW inverters with


unparalleled performances. The series is available in two versions,
high efficiency (HE) and standard: the HE version features improved
performance providing staggering efficiency of 98.6%, Euro efficiency
of 98.2%. The internal DC switch further improves the safety and
reliability of the products designed for a variety of applications: from
large residential installations to commercial rooftops and utility scale PV
systems.

Efficiency Curve
Inverter

CPS SCA10KTL-DOHE
99.00%

CPS SCA8KTL-DOHE CPS SCA8KTL-DO


97.00%
CPS SCA10KTL-DOHE CPS SCA10KTL-DO
Efficiency(%)

DC INPUT VOLTAGE
95.00% 320V CPS SCA12KTL-DOHE CPS SCA12KTL-DO
430V
93.00% 632V
800V
91.00% High Efficiency
0 2000 4000 6000 8000 10000
Output Power(W) Max. efficiency of 98.6%, Euro efficiency of 98.2%
≥99.9% MPPT efficiency
CPS SCA10KTL-DO

99.00% High Reliability


“Electrolyte-free design” for improved long-term reliability
97.00%
Fan-less design (SCA8KTL-DO/DOHE) for further reduced
Efficiency(%)

DC INPUT VOLTAGE noise levels


95.00% 320V
Integrated DC switch
620V GFCI embedded
93.00%
780V Comprehensive protection functions
5 years standard warranty, optional extension up to 20 years
91.00%
0 2000 4000 6000 8000 10000
Output Power(W)
Broad Adaptability
Dimensions 2 MPP Trackers for wider application range
Higher power for each MPP tracker for flexible
configuration
Wide input voltage and MPPT range
IP65 protection degree for outdoor applications
EMC class B
Active power derating, over frequency derating
and reactive power regulation
Low voltage ride through (CEI 0-21)
Standard RS485, USB, optional Ethernet, Zigbee
Standard USB for firmware upgrade
3rd Party Monitoring

G59 CEI 0-21 C10/11 VDE-AR-N 4105 VDE0126-1-1/A1

14
Inverter-Asia/Europe

CPS SCA8KTL-DOHE CPS SCA10KTL-DOHE CPS SCA12KTL-DOHE


Model Name
CPS SCA8KTL-DO CPS SCA10KTL-DO CPS SCA12KTL-DO
DC Input
Nominal DC Input Power 8.2kW 10.3kW 12.3kW
Max. DC Input Power for each MPPT 5kW 6kW 7.2kW
Max. DC Input Voltage 1000Vdc
Operating DC Input Voltage Range 250-950Vdc
Start-up DC Input Voltage / Power 320V/150W
Nominal DC Input Voltage 600V
MPPT Voltage Range 430-800Vdc*/320-800Vdc 430-800Vdc*/320-800Vdc 430-800Vdc*/380-800Vdc
Number of MPP Trackers 2
Number of DC Inputs (strings) 2x2
Max. Input Current 17A/MPPT
Max. Input Current per string 17A
DC Disconnection Type Integrated DC switch
PV Array Configuration Floating

Inverter
AC Output
Rated AC Output Power 8kW 10kW 12kW
Max. AC Output Power 8kW 10kW 12kW
Rated Output Voltage 400Vac
Output Voltage Range# 320-460Vac
Grid Connection Type 3Φ/N/PE
Max AC Output Current 12.5A 15.2A 18.2A
Rated Output Frequency 50Hz/60Hz
Output Frequency Range# 47-53Hz/57-63Hz
Power Factor >0.99 (±0.9 adjustable)
Current THD <3%
AC Disconnection Type -
System
Topology Transformerless
Max. Efficiency 98.6%*/98.3%
Euro Efficiency 98.2%*/97.9%
Stand-by / Night Consumption <20W/<0.3W
Environment
Protection Degree IP65
Cooling Natural Convection Variable speed cooling fans Variable speed cooling fans
Operating Temperature Range -25°C to +60°C
Operating Humidity 0-95%, non-condensing
Operating Altitude 4000m
Display and Communication
Display LCD+LED
Communication Standard: RS485, USB; Option: Ethernet, Zigbee
Mechanical Data
Dimensions (WxHxD) (mm) 500x680x216
Weight (kg) 41 43 43
Compliance
LVD: 2006/95/EC, IEC/EN 62109-1: 2010, IEC/EN 62109-2: 2011.
Safety and EMC Standards
EMC: 2004/108/EC, Class B, IEC/EN61000-6-2: 2005, IEC/EN61000-6-3: 2007.
Grid Standards VDE-AR-N 4105, VDE V 0126-1-1/A1; C10/11, CEI 0-21, G83/1-1, G59/2, NRS097
# The "Output Voltage Range" and "Output Frequency Range" may differ according to specific grid co
* HE: High efficiency model
* MAX recommended PV array power ≤1.3P(P for Rated AC output power), PV array power range depend on the type of installation
and geographical location.
15