Proforma Invoice

Ref: SCS/CAL/23-24/Q-202387
Date:25.10.2023
To,
Comfit Lab Services Limited.
Gorai, Mirzapur, Tangail

Attn: Md. Hasnayet Rone


Supply Chain
Management

Sub: Quotation for Calibration of Lab machineries & Instruments.

Dear Sir,
Reference to your mail on the Date of 23.10.2023, we would like to submit our best price offer for calibration of the following
instruments: -

Sl. Unit Total Price


Equipment Name Eq No. Model Parameter
No Qty. (BDT)
1.Repeatability of reading*
Testometric -Tensile 2.Load Cell *
1 EQ: 002 M350-5CT 01 10000
Testing Machine 3. Linearity of reading*
4. crosshead speed#
1440 1. Bursting strength of diaphragm#
TruBurst4 –Bursting
2 EQ: 003 TRUBURS 2. Inner clamp ring diameter* 01 3000
Strength Tester 3. Dome diameter*
T4
1. Insert diameter of mounting holder*
2.Number of figures in a Lissajous figure
for Abrasion and Pilling #
3. Length and width of each of the
9 Lissajous figure for Abrasion and
Pilling*
4. Rotational speed of pegs and
accuracy of counter #
5. Press weight (mass) *
6. Press weight (diameter) *
7. Stroke Length (a. abrasion b. pilling) *
8. Protrusion Diameter/ pin diameter *
9. Parallelism between abrading table
Maxi-Martindale-
and specimen holder Insert surface#
Abrasion and Pilling
1309, Maxi 10. Ease of running of the specimen
3 Tester with Pilliing EQ: 005 01 2500
Martindale in needle bearing assembly#
Abrassion Cutter &
11. Clamping ring upper diameter for
Pilling Sample Cutter
each of the table#
12. Specimen Holder lift of each of
the table#
13. Total mass of specimen holder &
spindle -with & without weight*
14. Total mass of large specimen holder
and spindle-with & Without weight*
15. Face diameter of specimen holder
insert*
16. Correction settings of Martindale -
color change of specimen
17. End-point checking of Martindale-
wearing of specimen. #

Registered Office: Union Heights 55-2, Bir Uttam Qazi Nuruzzaman Sarak, West Panthapath,Dhaka-
1205.
Sales Office: House # 57 Road # 05, Sector # 12 Uttara, Dhaka. Mob: +880
Proforma Invoice

Zipper Slider Roaches,


4 EQ: 006 As Per standard 01 1000
Reciprocating Tester UK

Registered Office: Union Heights 55-2, Bir Uttam Qazi Nuruzzaman Sarak, West Panthapath,Dhaka-
1205.
Sales Office: House # 57 Road # 05, Sector # 12 Uttara, Dhaka. Mob: +880
Proforma Invoice

1. Mass of polyurethane tube *


2. Rotational Speed #
3. Rotational speed in Reversing Action*
4. Box Dim ension (Left side) *
Orbiter Pilling & 1516 5. Box Dimension (Right side) *
5 EQ: 007 01 1000
Snagging Tester ORBITOR 6. Dimension, thickness & of
polyurethane
tube (Outer diameter & Thickness)*
7. Crock lining#
8. Pilling box with reference fabric#
Saf Guard-Universal
Force 1. Checking of Force Gauge applying
Mechanical Safety
6 EQ: 008 Gauge- different force 01 1,000
Tester with Pressure
IMADA 2. Calibration Weight check
Wight (EQ:A-012)
1. One-point checks*
2. Departure from nominal value*
3. Repeatability of reading*
7 Electronic Balance EQ: 009 ME203E 01 1000
4. Effect of off Centre loading*
5. Hysteresis*
6. Limit of performance*
1. Rubbing Finger diameter &
smoothness*
8 Crock master EQ: 010 680 2. Stroke length* 01 800
3. Rubbing Downward Force
4. Abrasive paper
1. Rubbing Finger diameter &
smoothness*
9 Rotary Crock Meter EQ: 011 2. Stroke length* 01 1000
3. Rubbing Downward Force
4. Abrasive paper
Thermohygrograph 1. Relative Humidity *
10 EQ: 012 7210-00 2. Temperature Check*
01 800
Meter
11 GSM Cutter EQ: 013 ---------- Dimension Calibration# 01 800
1. Wash Speed#
2. Spin Speed#
12 Electrolux Washer EQ: 014-A W555H 3.Wash Time# 01 1000
4. Check Temperature at Different
Points (check at Three Different Cycles).
1. Wash Speed#
2. Spin Speed#
13 Electrolux Washer EQ: 014-B WH6-6 3.Wash Time# 01 1000
4. Check Temperature at Different
Points (check at Three Different Cycles).
1. Wash Speed#
2. Spin Speed#
14 Electrolux Washer EQ: 014-C WH6-6 3.Wash Time# 01 1000
4. Check Temperature at Different
Points (check at Three Different Cycles).
1. Wash Speed#
2. Spin Speed#
15 Electrolux Washer EQ: 014-D WH6-6 3.Wash Time# 01 1000
4. Check Temperature at Different
Points (check at Three Different Cycles).
1.Wash Speed#
Electrolux FOM71
16 EQ: 015 2.Spin Speed# 01 1000
WASCATOR CLS
3.Wash Time#

Registered Office: Union Heights 55-2, Bir Uttam Qazi Nuruzzaman Sarak, West Panthapath,Dhaka-
1205.
Sales Office: House # 57 Road # 05, Sector # 12 Uttara, Dhaka. Mob: +880
Proforma Invoice

4. Check Temperature at Different


Points (check at Three Different Cycles).
1.Wash Speed#
2.Spin Speed#
Electrolux FOM71
17 EQ: 016 3.Wash Time# 01 1000
WASCATOR CLS
4. Check Temperature at Different
Points (check at Three Different Cycles).
1.Wash Speed#
2.Spin Speed#
Electrolux FOM71
18 EQ: 016 A 3.Wash Time# 01 1000
WASCATOR CLS
4. Check Temperature at Different
Points (check at Three Different Cycles).
1.Wash Speed#
PW6055 2.Spin Speed*
Miele Washing
19 EQ: 017 PLUS 3.Wash Time# 01 1000
Machine
(VARIO) 4. Check Temperature at Different
Points*
1. Different Temp*
20 Dyna Wash EQ: 019 825 2. Speed* 01 1000
3. Time *
1. Different Temp*
Gyrowash2 Washing 1315 20
21 EQ: 020 2. Wash Speed# 01 1000
Machine Gyrowash2 3. Wash time #
Type 1. Exhaust Temperature*
22 Electrolux Dryer EQ: 022 T5130 2. Cool Down Time#
01 1000
Type 1. Exhaust Temperature*
23 Electrolux Dryer EQ: 023 2. Cool Down Time#
01 1000
T5130
1. One-point checks*
2. Departure from nominal value*
JL6001- 3. Repeatability of reading*
24 Electronic Balance EQ: 024 01 1000
G/L 4. Effect of off Centre loading*
5. Hysteresis*
6. Limit of performance*
1. One-point checks*
2. Departure from nominal value*
3. Repeatability of reading*
25 Electronic Balance EQ: 027 ME203E, 01 1000
4. Effect of off Centre loading*
5. Hysteresis*
6. Limit of performance*
1. 5 Point RPM measurement.
Shaking & heating
26 EQ: 028 BS-31 2. Time# 01 1000
water Baths 3. Temperature*
1. Temperature range of the incubator*
2. Plotting of the calibration curve
27 Electric Oven EQ: 029 AX60 of actual measured (average value) 01 1000
against display temperature*
1. Temperature range of the incubator*
2. Plotting of the calibration curve
28 Electric Oven EQ: 030 AX30 of actual measured (average value) 01 1000
against display temperature*
620
29 Thermo plate EQ: 031 Thermo Temperature at different range* 01 800
plate
1. Mass of weight
30 Perspirometer EQ: 032-A 01 1000
2. Dimension
1. Mass of weight
31 Perspirometer EQ: 032-B 2. Dimension 01 1000

Registered Office: Union Heights 55-2, Bir Uttam Qazi Nuruzzaman Sarak, West Panthapath,Dhaka-
1205.
Sales Office: House # 57 Road # 05, Sector # 12 Uttara, Dhaka. Mob: +880
Proforma Invoice

1. Mass of weight
32 Perspirometer EQ: 032-C 2. Dimension 01 1000
1. Mass of weight
33 Perspirometer EQ: 032-D 2. Dimension 01 1000
1. Mass of weight
34 Perspirometer EQ: 032-E 01 1000
2. Dimension
1. One-point checks*
2. Departure from nominal value*
3. Repeatability of reading*
35 Electronic Balance EQ: 033 ME203E 01 1000
4. Effect of off Centre loading*
5. Hysteresis*
6. Limit of performance*
1. Temperature range of the incubator*
Electric Oven
2. Plotting of the calibration curve
36 (CARBOLITE EQ: 035 AX60 of actual measured (average value) 01 1000
Incubator Oven) against display temperature*
SSL1, 1. 5 Point RPM measurement.
Orbital- Mechanical
37 EQ: 036 Orbital, 2. Time# 01 800
Shaker
Lab Scale,
1. One-point checks*
2. Departure from nominal value*
3. Repeatability of reading*
38 Electronic Balance EQ: 037 PL601-S 01 1000
4. Effect of off Centre loading*
5. Hysteresis*
6. Limit of performance*
1. 5 Point RPM measurement.
Shaking & Heating
39 EQ: 038 BS-31, 2. Time# 01 1000
Water Baths 3. Temperature*
SSL1, 1. 5 Point RPM measurement.
Orbital- Mechanical
40 EQ: 039 Orbital 2. Time# 01 800
Shaker
Lab Scale.
1. Calibration of pH at pH 1) pH 4-7 ii)
Five Easy pH 4-7 iii) pH 7- 10 #
41 pH Meter EQ: 040 A 01 800
Plus FP20 2. Intermediate Check: #

1. Calibration of pH at pH 1) pH 4-7 ii)


Five Easy pH 4-7 iii) pH 7- 10 #
42 pH Meter EQ: 040 B 01 800
Plus FP20 2. Intermediate Check: #

1. Temperature range of the incubator*


Electric Oven
2. Plotting of the calibration curve
43 (CARBOLITE EQ: 041 AX30 of actual measured (average value) 01 1000
Incubator Oven) against display temperature*
Lux measurement at different point (5
44 Verivide Light Box EQ: 043 CAC 120–5 points) Bulb to, Table Surface 01 1000
Distance Dimension of Table#
Pilling Assessment Lux measurement Bulb to, Table Surface
45 Viewer EQ: 044 PAV Distance Dimension of Table# 01 1000
1.Length
46 Torque Gauge EQ: 046 type 9BTG 01 800
2.Torque
47 Hot Plate EQ: 047 SCO-5031 Temperature at different range* 01 800
Magnetic Stirrer with 1. Temp*
48 Heater EQ: 049 -- 2. Speed# 01 800
49 Electronic Timer EQ: 050-A 06-662-51 Time calibration up to 4hrs* 01 800
50 Electronic Timer EQ: 050-B 06-662-51 Time calibration up to 4hrs* 01 800
51 Electronic Timer EQ: 050-C 06-662-51 Time calibration up to 4hrs* 01 800
52 Electronic Timer EQ: 050-D 06-662-51 Time calibration up to 4hrs* 01 800

Registered Office: Union Heights 55-2, Bir Uttam Qazi Nuruzzaman Sarak, West Panthapath,Dhaka-
1205.
Sales Office: House # 57 Road # 05, Sector # 12 Uttara, Dhaka. Mob: +880
Proforma Invoice

53 Electronic Timer EQ: 050-E 06-662-51 Time calibration up to 4hrs* 01 800


54 Electronic Timer EQ: 050-F Time calibration up to 4hrs* 01 800
55 Electronic Timer EQ: 050-G Time calibration up to 4hrs* 01 800
56 Electronic Timer EQ: 050-H Time calibration up to 4hrs* 01 800
57 Test Sieve EQ: 053-B As Per standard 01 800
58 Conductivity Meter EQ: 054 BC3020 Conductivity Checks 01 800
59 Micro Pipette EQ: 060 Volume Calibration* 01 800
VITLAB 800
60 Micro Pipette EQ: 061 micropipet Volume Calibration* 01
te
61 Measuring Tape EQ: 063-T Length Calibration 01 800
62 Measuring Tape EQ: 063-U Length Calibration 01 800
1. One-point checks*
2. Departure from nominal value*
3. Repeatability of reading*
63 Electronic Balance EQ: 066 PCB250-3 01 1000
4. Effect of off Centre loading*
5. Hysteresis*
6. Limit of performance*
BIG-DIGIT
1. Relative Humidity *
64 Digital Thermometer EQ: 069 THERMOM 01 800
2. Temperature Check*
ETER
65 Electric Iron EQ: 079 GC1752 1.Temperature Check* 01 800
1. Mass of polyurethane tube *
2. Rotational Speed #
3. Rotational speed in Reversing Action*
4. Box Dimension (Left side) *
Circular Locus 5. Box Dimension (Right side) *
66 EQ: 074 M235P 01 1000
Machine 6. Dimension, thickness & of
polyurethane
tube (Outer diameter & Thickness)*
7. Crock lining#
8. Pilling box with reference fabric#
Template- British
Standard
67 Dimensional EQ: A- 044 -- Physical Dimension 01 1200
Stability- 350
MM X 350 MM
1.Parallesim*
CD-12''
68 Digital Caliper REF EQ-01 2.Depth Error* 01 1000
CSX. 3. Main Scale Reading*
69 Digital Thermometer REF EQ-02 HI 93530, Temperature Check* 01 800
Lux Meter/Light REF EQ-
70 LX-1108 Lux measurement at different point# 01 800
Meter 03A
Checking of Force Gauge applying
71 Digital Force Gauge REF EQ-04 ZTS-50N different force# 01 1000
72 Measuring Tape REF EQ-09 Germany Length Calibration 01 800
73 Digital Stop Watch REF EQ-10 Time calibration up to 4hrs 01 800
1.Relative Humidity*
74 Sling Psychrometer REF EQ-11 P 2528 01 800
2.Temperature Check*
75 Set Square REF EQ-12 Camlin, Dimension calibration 01 800
Lutron,
76 Tachometer REF EQ-13 RPM* 01 800
DT-2236
Glassware

GL-MC-
77 Measuring Cylinder Volume Calibration* 01 800
04D

Registered Office: Union Heights 55-2, Bir Uttam Qazi Nuruzzaman Sarak, West Panthapath,Dhaka-
1205.
Sales Office: House # 57 Road # 05, Sector # 12 Uttara, Dhaka. Mob: +880
Proforma Invoice

Brown Volumetric GL-BVF- 800


78 Flask 05A Volume Calibration* 01
Brown Volumetric GL-BVF- 800
79 Volume Calibration* 01
Flask 05B
80 Burette GL-BR-01B Volume Calibration* 01 800
GL-HM- 800
81 Hydrometer 01A As Per standard 01
GL-HM- 800
82 Hydrometer As Per standard 01
02A
GL-HM- 800
83 Hydrometer As Per standard 01
03A
GL-HM- 800
84 Hydrometer As Per standard 01
04A
GL-HM- 800
85 Hydrometer As Per standard 01
05A
Total Amount In BDT= 89,100/-
Special Discount (20%) = (-)17,820/-
Total Calibration Charge In BDT= 71,280/-
VAT (10%) = (+)7,128/-
Total Calibration Charge in BDT (Including Vat) = 78,408/-

Total Instruments= 85 pcs (Total: Seventy eight thousand four hundred eight) only

Note: 1. * under our scope of NABL.


2. # under associate’s scope of NABL.

Features of our Services


 Our Laboratory is NABL Accredited for the Force, Electro-technical, Dimensional, Pressure, Mass, Volume, Torque,
Humidity and Thermal Parameter.
 Our Associate Laboratory is NABL Accredited for the Force, Electro-technical, Dimensional, Pressure, Mass,
Volume, Torque, Humidity, Sound, Speed, Density, Humidity and Thermal Parameter.
 Each certificate will accompany measurement uncertainty as per NABL-129.
 We follow Indian/International standards for calibration of instruments and ISO/IEC 17025:2017 for calibration
requirement.
Terms of offer:
Calibration certificate will be provided by Essjay Technomeasure Pvt Ltd, India.
 which has a multidisciplinary NABL Accredited Calibration Lab.
 Offer validity 30 days from the date of issue.
 VAT Included &Tax Excluded.
 Job will be completed within 05 days after receiving of work order along with payment.
 You can issue cheque in favor of SMARTCARE SOLUTION LTD. A/C No: 1052101000012660, Type: Current
Account, Bank Name & Branch: UCBL Sonargaon Janapath Branch, Uttara Dhaka, Routing No: 245276581, Swift
Code: UCBLBDDH or direct in cash.
 Calibration certificate will be issued within 07-10 days after completing job from INDIA.
 We will be delivered certificate hard copy only after receiving the full payment.

Assuring you best services at all times & thanking you.