Professional Documents
Culture Documents
15KWh Power Wall Battery User Manual 2023V2.0 (Standard)
15KWh Power Wall Battery User Manual 2023V2.0 (Standard)
15KWh Power Wall Battery User Manual 2023V2.0 (Standard)
Version 1.0
2 Safety ................................................................................................................................................................. 1
4 Technical Items................................................................................................................................................ 3
7 Maintenance ..................................................................................................................................................... 15
7.1 Daily Maintenance.................................................................................................................................................................. 15
7.2 Periodic Maintenance ........................................................................................................................................................... 16
10 Warranty ......................................................................................................................................................... 17
1 General Information
1.1 Validity
This user manual is applicable to the Shenzhen Boli Technology Co., Ltd. series battery product.
1.2 Application
This user manual contains BL Power Wall Battery product information, usage guidance, safety
information, and details on common operating issues and subsequent corrective actions.
BL Floor Standing Battery is an energy storage unit that is designed to be used in residential
applications with the capability for short-term backup.
2 Safety
This section contains safety information that must be observed at all times when working on or
with batteries. To prevent personal injury or property damage and to ensure long-term operation
of the batteries, read this section carefully and observe all safety information at all times.
WARNING
Environmental requirement
• Do not expose the battery to temperature above 50℃
• Do not place the battery near any heat sources
• Do not expose the battery to moisture or liquids
• Do not expose the battery to corrosive gases or liquids
• Do not expose the battery to direct sunlight for extended periods of time
• Place battery in secure location away from children and animals
• Do not allow the battery power terminals to touch conductive objects such as wires
Operation Precautions
• Do not disassemble the battery
• Do not touch the battery pack with wet hands
• Do not crush, drop or puncture the battery
3 Technical Data
Weight (Kg) 114(115kg with mounting part) 125(126kg with mounting part)
4 Technical Items
No. Terms Comment
1 Discharge Battery output power for load
2 Charge To put electricity into battery by the charger
3 Full charged Battery had been full charged, SOC is 100%.
4 Idle Ready for charging or discharging
5 Shutdown mode Power off
6 SOC State of Charge
7 SW Software
8 HW Hardware
9 Battery voltage The voltage between B+/B-
10 Pack voltage The voltage between P+/P-
11 Cell voltage Single cell voltage
12 Failure Battery or BMS is broken, need to be replaced
13 Alarm Indicate that the battery is in an abnormal status
14 Over discharged Energy state of the battery is too low and needs to be recharged
5 Product Overview
5.1 Brief introduction
This product is a low-voltage DC battery system with an operating voltage. It is utilized in
household energy storage applications and works together with a low-voltage inverter to realize
the goal of energy storage for the home.
❶ ❷ ❸ ❹ ❺ ❻ ❼ ❽ ❾ ❿ ⓫ ⓬ ⓭ ⓮ ⓯
Panel view
❷ Mounting ❸ P+ Output
❶ Handle ❹ Ground Terminal ❺ SOC LEDs
Bracket Terminal
❾ CAN/RS485 Port
❻ Alarm LED ❼ Run LED ❽ DIP Switch ❿ RS485-1 Port
(Inverter)
⓭ P- Output
⓫ RS485-2 Port ⓬ Reset Button ⓮ Base Knobs ⓯ Screen Buttons
Termina
The P+ and P- output terminals are located at the upper left and the upper right of the BU panel
respectively, representing the positive and negative terminals of the BU.
The "RESET" button is used for system activation, power on and reset.
Function Definition
When the BMS is in the sleep mode, after pressing the RESET button
Power
for 3s, the BMS is activated, and the LED indicator lights flash in turn,
on/wake up
then it shifts to the normal operation mode.
The unit has one CAN interfaces for up device like power or inverter.
The unit has two RS485 interfaces. The interfaces are independent physical serial ports. By setting
different dialing addresses of the BU, multiple BU can be cascaded.
The address adopts BCD code format, dial up is on and dial down is off. It uses 8 bits as address setting, dial
1 is the low bit and dial 8 is high bit.
Definition of parallel dial switch: for multi-computer communication when the battery pack is in parallel, the
dial switch is used to distinguish different pack addresses, and the hardware address can be set through the
dial switch on the board. (Support 8 groups of parallel machines, default 8 groups of parallel machines, 16
groups of parallel machines require special requirements).
Definition of dial switch bit1 to bit8: bit1 to bit4 is used to set the address, and bit5 to bit8 is used to set the
number of slaves.
Host settings: bit1 to bit4 are 0, the host address is fixed to 0, and bit5 to bit8 are set according to the
number of parallel slaves.
Slave setting: bit1 to bit4 are set according to the device sequence, and the slave address range is 1 to 15.
Bit5 to bit8 are fixed to 0.
Note: For parallel connected multiple BUs, if address settings are the same, the communication will not work.
Correspondence table between BU address number and Dip switch position (Host settings)
Number of
batteries in Dip Switch 5 Dip Switch 6 Dip Switch 7 Dip Switch 8
parallel
2 ON OFF OFF OFF
3 OFF ON OFF OFF
4 ON ON OFF OFF
5 OFF OFF ON OFF
6 ON OFF ON OFF
7 OFF ON ON OFF
8 ON ON ON OFF
9 OFF OFF OFF ON
10 ON OFF OFF ON
11 OFF ON OFF ON
12 ON ON OFF ON
13 OFF OFF ON ON
14 ON OFF ON ON
15 OFF ON ON ON
There are 4 LEDs indicating different SOC levels, 1 LED indicating RUN, and 1 LEC indicating Alarm. The LED
indications under different running modes.
LED blink mode description
Blink Mode On (Duration) Off (Duration)
B1 0.25 S 3.75 S
B2 0.5 S 0.5 S
B3 0.5 S 1.5 S
RU AL
L1 L2 L3 L4
Normal/Alarm/ N M
State Description
Protection
● ● ● ● ● ●
Shutdown Sleep Off Off Off Off Off Off The BU is OFF
Abnormal
temperature, over-
Off On Off Off Off Off Stop charging
current, failure
protection
Invalid Off On Off Off Off Off Stop charge & discharge
When multiple units are connected in parallel, RS485 interface is used as parallel communication interface,
and CAN/RS485 interface is used as uplink communication interface.
When multiple units are connected in parallel, the RS485 interface connection is shown in the figure below:
5.2.8 Screen
It can provide intuitive battery parameter display, and has the characteristics of simple operation, friendly
interface, etc.
Panel view
a. Interface introduction
1) Main menu page
After power on / sleep activation, the welcome interface will be displayed. Press the menu key to enter the
main menu page. As shown in the figure below:
b. Key description
1) MENU, ENTER, DOWN, ESC.
2) Each item starts with "》" or "--", where "》" indicates the current cursor position. Press down to move the
cursor position downward; An item ending with "he" indicates that there is something not displayed in the
item. Press enter to enter the corresponding page.
3) Press ESC to return to the previous directory; At any position, press the menu key to return to the main
menu page.
4) In the sleep state, press any key to activate the display screen.
c. Sleep / shutdown
In the normal operation state, the system will enter the sleep / shutdown state after 1 minute without key
operation. In the shutdown / sleep state, operate any key to activate the display screen.
After connecting the power line of the battery to other equipment, then turn the CB to "on" at
the battery .
When the grid is normal, the power system provides the power required by the load system and charges the
battery system at the same time. Under the power failure circumstance, the battery system provides power to
the load to ensure the uninterrupted normal operation of the load system. When the battery is discharged
and the mains are still not restored, the battery will automatically cut off the output to prevent any damage
due to over discharge.
6 Installation Guide
6.1 Installation preparation
▪ Unpacking and inspection
Please unpack carefully and check
a. The packing list,
Table 6-1. packing list
Items Quantity Items Remarks
A 1 BL Powerwall Battery
B 4 M5 terminal
▪ Connection steps
a. Prepared tools and materials: protective gloves, screwdriver, and lifting equipment.
b. Wear protective gloves.
c. After opening the screws of the upper cover and taking out the upper cover, you will see the interface of
the battery.
d. Install the communication cable of BL Powerwall Battery.
e. After the installation of BL Powerwall Battery communication cables, connect the last RS485 interface of
battery to the monitoring equipment.
f. Install the power cables via connectors on the BL Powerwall Battery.
Note: Make sure that P+ cable and P- cable is terminated on the right sides of the connector.
Polarities are marked on the BU, please follow the markings carefully.
After connecting with the inverter cable, close the circuit breaker of the battery first, and then
close the circuit breaker of the inverter.
Installation*1
Installation*2
7 Maintenance
7.1 Daily Maintenance
a. When charging the BU, trained personnel should take care of it. During the charging process, ensure that
the plug is in good contact with the socket, the charging equipment is working normally, and the
connection points of the BU are in good contact. If there is an abnormality, immediately cut off the
power and charge it only after repairing.
b. Before charging and discharging the BU, the battery voltage, temperature and differential pressure can
be read by BMS host computer to ensure that all values are in the normal range.
c. If there is a large amount of dust, metal chips or other debris on the upper cover and pole of the BU, use
compressed air to clean it. Do not use water or objects soaked in water for cleaning.
d. When charging and discharging the BU, it is forbidden to splash water or other conductive objects on
the BU cover and pole, such as exposing the BU to heavy rain.
e. According to the actual use state of the BU, the charging time and discharge time of the BU are
estimated. At the end of charging and discharging, the BMS upper computer is used to observe whether
there is any abnormality in the BU, such as the problem of high cell voltage difference.
Daily maintenance content
Maintenance Contents Operation Method Precautions
Quarterly Check the bolts at each terminal, if they are loose, tighten them again.
Connection status If the temperature of the connecting wire exceeds 50 ℃ (excessive heating),
check the cause.
At the end of charging, measure and record the bus-bar voltage and the
Every 6 voltage at the positive and negative terminals of the BU, and the two voltages
Voltage detection
months should be consistent. Otherwise, check whether the cable at the corresponding
connection is faulty.
8.2 Transportation
In the process of handling, it should be handled with care and it should not be subject to external severe
impact. During transportation, it should be placed in strict accordance with the direction marked on the
packaging box to avoid product vibration and inversion.
8.3 Storage
The BU should be placed in a dry warehouse during storage and shall not be exposed to sunlight and rain.
The products with a storage period of more than 6 months should be subjected to a capacity check test and
recharged. Products with a storage period of more than 1 year shall be re-examined and used after being
qualified.