The end of December, 2017
[ Wire connection ]
Product discontinuation Recommendable replacement
Model G6DS Series Model G6DN Series
BOTTOM VIEW BOTTOM VIEW
[ Mounting dimensions ]
Product discontinuation Recommendable replacement
Model G6DS Series Model G6DN Series
BOTTOM VIEW BOTTOM VIEW
[ Dimensions ]
Product discontinuation Recommendable replacement
Model G6DS Series Model G6DN Series
Average value Average value
2
[ Characteristics ]
Product discontinuation Recommendable
Item Model G6DS Series replacement
Standard High-sensitivity Model G6DN Series
Ratings / Coil Ratings
Rated Voltage 5 V, 12 V, 24 V 5 V, 12 V, 24 V
70% max.
70% max.
Operating voltage is less than 72%
Operate voltage Operate voltage when the terminal is installed
when the relay is sideways and the
top of the relay is less than 75%
marking is right way.
Release voltage 5% min. 5% min.
Maximum voltage 160% (at 23 degree C) 160% (at 23 degree C)
Power consumption Approx. 180 mW Approx. 120 mW Approx. 110 mW
Ratings / Contact Ratings
Contact type Single Cross bar twin
Ag Alloy +
Contact material Ag Alloy + Au
Au (Only stationary contact)
250 VAC 5 A 250 VAC 5 A
Rated load (Resistive load)
30 VDC 5 A 30 VDC 5 A
250 VAC 2 A (cosφ= 0.4)
Rated load (Inductive load) ---
30 VDC 2 A (L/R = 7 ms)
Rated carry current 5A 5A
Characteristics
Contact resistance *1 100 mΩ max. 100 mΩ max.
Operate time 10 ms max. 10 ms max.
Release time 5 ms max. 5 ms max.
Insulation resistance *2 1,000 MΩ min. 1,000 MΩ min.
Between coil
3,000 VAC, 50/60 Hz for 1 min 3,000 VAC, 50/60 Hz for 1 min
and contacts
Dielectric
strength Between
contacts of the 750 VAC, 50/60 Hz for 1 min 750 VAC, 50/60 Hz for 1 min
same polarity
Impulse Between
withstand contacts of the 6,000 V (1.2 × 50 μs) 6,000 V (1.2 × 50 μs)
voltage same polarity
10 to 55 to 10 Hz, 2.5 mm
10 to 55 to 10 Hz, 0.75 mm single amplitude
Destruction single amplitude
(1.5 mm double amplitude)
Vibration (5 mm double amplitude)
resistance 10 to 55 to 10 Hz, 0.75 mm
10 to 55 to 10 Hz, 0.75 mm single amplitude
Malfunction single amplitude
(1.5 mm double amplitude)
(1.5 mm double amplitude)
Shock Destruction 1,000 m/s2 1,000 m/s2
resistance Malfunction 150 m/s2 130 m/s2 100 m/s2
Mechanical 20,000,000 operations min. 20,000,000 operations min.
100,000 operations min.: 80,000 operations min.:
5 A at 250 VAC/30 VDC, 5 A at 250 VAC/30 VDC,
100,000 operations min.:
1,800 operations an hour 1,800 operations an hour
3 A at 250 VAC/30 VDC,
100,000 operations min.: 100,000 operations min.:
Endurance 1,800 operations an hour
Electrical 2 A at 250 VAC (cosφ= 0.4), 2 A at 250 VAC (cosφ= 0.4),
80,000 operations min.:
1800 operations an hour 1,800 operations an hour 5 A at 250 VAC/30 VDC,
100,000 operations min.: 100,000 operations min.:
1,200 operations an hour
2 A at 30 VDC (L/R = 7 ms), 2 A at 30 VDC (L/R = 7 ms),
1,800 operations an hour 1,800 operations an hour
Failure rate (P level)
24 VDC, 5 mA 0.1 VDC, 0.1 mA
(reference value)
-40 degree C to +85 degree C -40 degree C to +90 degree C
Ambient temperature
(with no icing or condensation) (with no icing or condensation)
Note. Values in the above table are initial values.
3
Note 1. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
Note 2. The insulation resistance is measured between coil and contacts and between contacts of the same polarity
at 500 VDC.
[ Operation methods ]
Product discontinuation Recommendable replacement
Model G6DS Series Model G6DN Series
No difference
Specifications and prices in this product news are as of the issue date and are subject to change without notice.
Only main changes in specifications are described in this document. Please be sure to read the relevant catalogs, datasheets, product
specifications, instructions, and manuals for precautions and necessary information when using products.