UL recognized

File: nº E 151092

SPECIFICATIONS: DESCRIPTION:
• IEC 60684-3 sheets 400-402
• UL 1441 Sleeving made of a special silicone rubber coated fiberglass
braid. This is a Class 200 electrical insulating sleeving available in
three voltage grades.
APPLICATION:
Ideal thermal and electrical
insulating material for points
and appliances at high
temperatures with thermal OPERATING TEMPERATURE: -70ºC to +235ºC
overcharges (incandescent Peaks at +300ºC
lamps, domestic appliances,
carbon brush flexible),
chemical resistance and
dielectric strength of silicone
elastomer. It exhibits
exceptional high and low ITS MAIN FEATURES ARE:
temperature properties.
• Halogen free.
• Self-extinguishing VW 1.
• Highly flexible.
• Excellent chemical resistance to oils, fluids and aggressive
chemical agents.

NOTE: Colour tone may vary. This does not affect technical properties of sleeve.
Relats does not establish maximum wall thickness value
DIELECTRIC STRENGTH:

TEST METHOD VSC25


2,5 kV grade
Minimum
IEC 60684 250 mm. Inst. B / D Central Value (kV) 3,0
IEC 60684 250 mm. Inst. B / D Lowest Value (kV) 2,5
UL 1441 25 mm. Inst. B / D (kV) 4,0

TECHNICAL CHARACTERISTICS:

PROPERTY TEST RESULT


PUT UP:
HEAT UL 1441: No cracking or detachment of
On coils of variable length, RESISTANCE 7 days at 265ºC coating shall be visible and the
depending on the diameter of 60 days at 235ºC original colors shall be clearly
the sleeving. On request in cut
recognizable.
lengths or spools.
FLAMMABILITY Flame propagation: Extinguishes within 60
IEC 60684 Part 2 clause 26 seconds.
HANDLING: Method B
Care should be taken to Vertical without mandrel
minimize dust formation during
UL 1441 Self-extinguishing VW 1
handling and cutting this glass
based material as dust or broken (sleeving in vertical position)
particles may cause skin COLD Bending at low temperature No cracking or detachment of
irritation. The use of barrier RESISTANCE IEC 60684 Part 2 Clause 14 coating shall be visible.
creams on exposed areas will
minimize the risk of skin
at -70ºC
irritation. For product safety data CHEMICAL Simulation of real operating Compatible with most insulating
and product disposal advice, see RESISTANCE conditions varnishes and transformer oils.
separate Safety Data Sheet.

DIMENSIONS:
NOTES:
This information and data is REFERENCE Nominal Bore Minimum Wall STANDARD
believed to be accurate and bore (mm) tolerance thickness PACKAGING
reliable. We place at your (mm) (mm) (m)
disposal the technical
VSC25_ _ 005 0,5 + 0,20 0,20 400,00
information necessary for the
correct use of our products and VSC25_ _ 008 0,8 + 0,20 0,20 400,00
offer the possibility of simulating
VSC25_ _ 010 1,0 + 0,20 0,30 400,00
in our laboratory the conditions
of many applications, in order to VSC25_ _ 015 1,5 + 0,20 0,30 200,00
advise on the suitability of our
products. As conditions and VSC25_ _ 020 2,0 + 0,20 0,30 200,00
methods of use are beyond our VSC25_ _ 025 2,5 + 0,20 0,30 200,00
control, the user must confirm
suitability before adopting our VSC25_ _ 030 3,0 + 0,20 0,30 200,00
products for commercial use. VSC25_ _ 035 3,5 + 0,30 0,30 200,00
We reserve the right to modify
characteristics with the aim of VSC25_ _ 040 4,0 + 0,30 0,30 200,00
improving the product and VSC25_ _ 045 4,5 + 0,30 0,40 200,00
adapting it to the requirements of
the market. VSC25_ _ 050 5,0 + 0,30 0,40 200,00
VSC25_ _ 060 6,0 + 0,30 0,40 200,00
VSC25_ _ 070 7,0 + 0,30 0,40 200,00
VSC25_ _ 080 8,0 + 0,30 0,45 100,00
VSC25_ _ 090 9,0 + 0,50 0,45 100,00
VSC25_ _ 100 10,0 + 0,50 0,45 100,00
VSC25_ _ 110 11,0 + 0,50 0,45 100,00
VSC25_ _ 120 12,0 + 0,50 0,45 100,00
VSC25_ _ 130 13,0 + 0,50 0,60 100,00
VSC25_ _ 140 14,0 + 0,50 0,60 50,00
VSC25_ _ 150 15,0 + 0,50 0,60 50,00
VSC25_ _ 160 16,0 + 1,00 0,60 50,00
VSC25_ _ 180 18,0 + 1,00 0,60 50,00
VSC25_ _ 200 20,0 + 1,00 0,90 50,00

NOTE: Standard color: Black and red-brown


Other diameters supplied upon request