Gas Release Welding Incident

You might also like

Download as pdf
Download as pdf
You are on page 1of 1
Gas Release During Welding Inci lent Other pipeline Pipeline soloed Upstream oe Pipeline Isolated Downstream ! What Happened 41. Work planned to replace pipeline y-lateral from abandoned well with spool 2. Pipeline was pigged, isolated and depressured for the job 2 What Else Could Have Happened Welder did not ati 3. It was believed that plungerlft well on timer tied . 9 did not recognize pipe vibration co into a different pipeline "Gas released during welding a * Fire/explosion 4. Work began, y-lateral was removed, spool being + Four workers in bell hole seriously burned installed by welder 5. Unknown to work crew timer started plunger-lft well 6. Welder noticed pipe vibrating, alerted other workers and they all scampered out of bell hole 7. Mud plug let go and gas released into bell hole

You might also like