Professional Documents
Culture Documents
Reinforcement Sec 1 Flange
Reinforcement Sec 1 Flange
1. Design Information
Design Code Eurocode2-2:05
Unit System kN, mm
Material Data fck = 0.04, fyk = 0.413686, fyw = 0.413686 kN/mm^2
Beam Span 850 mm
Section Property Top flange (No : 1)
2. Section Diagram
[END-I] [MID] [END-J]
25
25
25
200
200
200
25
25
25
1000 1000 1000
4. Shear Capacity
END-I MID END-J
Load Combination No. 3 3 3
Factored Shear Force (V_Ed) 13.44 10.41 10.78
Shear Strength by Conc.(V_Rdc) 109.57 109.57 109.57
Shear Strength by Rebar.(V_Rds) 73.11 73.11 73.11
Required Shear Reinf. (Asw) 141.9352 141.9352 141.9352
Required Stirrups Spacing 2.0-#3 @110 2.0-#3 @110 2.0-#3 @110
Check Ratio 0.1227 0.0950 0.0984
Modeling, Integrated Design & Analysis Software Print Date/Time : 11/22/2023 11:12
http://www.MidasUser.com
MIDAS/Civil V 8.8.5 LAN