A. HYDRAULIC DIAGRAM
COMMUNICATING REGULATOR
REGULATEUR COMMUNICANT
NAVISTEM
LMS B3000
OCI345
VERS
OCI345
0/10 VTO
LPBtovers
V SIGNAL
bus
SIGNAL
ou bus
or LPB
0/10
Appliance
Quantity Order No.
reference
Communication kit for LPB bus 1 OCI 345 059572
}
D. SPECIFIC START-UP PROCEDURE
Mains supply 230 L N Y1 N Y2 L N L N L N
VAC 50 Hz QX2 QX3 QX1 AUX2 AUX1
BX2
Gnd
LPB bus BX3
Gnd
}
DB MB B3
Gnd
B9
Gnd
H1 } Analogue
0...10V
input
Gnd
H5
Gnd
"
"
Fit the accessories and make their electrical connections.
"
Start up the boiler alone.
Make the following settings:
Line No. Value
• Time and date menu
Set the time Time / minute (1) HH.MM
Set the date Day / month (2) DD.MM
Set the year Year (3) YYYY
In both cases
• Configuration menu
Check the hydraulic diagram Generator 1 check (6212) 14
Generator 2 check (6213) 0
Information on DHW (6215) 0
Information on heating circuits 3, 2 and 1 (6217) 0
F. OPTIMISATION OF SETTINGS
Maintenance optimisation:
It is possible to generate a maintenance message without harming the boiler. This maintenance
message may appear when the 3 following meters have elapsed:
• Time since last maintenance (or commissioning): set parameter 7044 to 12 months
• Operating hours of the burner (parameter 7040)
• Number of start-ups (parameter 7042)
The last 2 parameters depend on the boiler room's hydraulic installation. It is recommended to
use at least parameter 7044 for yearly maintenance.