TECHNOLOGIES
GAS-BASED SUPPRESSION SYSTEMS
Highly effective for many applications
Quick and effective fire fighting is the strong point of carbon dioxide extinguishing systems. Extinguishing with
carbon dioxide is achieved by displacing the oxygen from a fire source quickly - and thus starving the
fire. The high heat binding capacity of the carbon dioxide causes the withdrawal of energy from the source of
the fire, which enhances the extinguishing effect.
Only possible with carbon dioxide Carbon dioxide Carbon dioxide extinguishing systems, due to their
extinguishing systems are especially well-suited for special extinguishing agent properties, feature advan-
high risk areas, where, in the event of a fire, it is tages over other inert gas extinguishing systems: Even
necessary to keep the protected objects available and freestanding objects in a room can be protected. The
functioning,to minimize operational interruptions liquefied carbon dioxide forms a thick aerosol cloud
after a fire, to prevent reactions between the burnt in the flooding zone. Special local application nozzles
material and the extinguishing agent, to prevent put the extinguishing agent precisely at the object to
damage from the extinguishing agent itself and to be protected.
ensure effective extinguishing of objects in areas with
difficult access (3-D extinguishing effect).
2
Optimized and individually customized Safe is better
The required quantity of extinguishing agent The extinguishing process with carbon dioxide redu-
depends on the volume and surface of the protec- ces the oxygen in the air in the protected zone sig-
tion zone, the quality (e.g. gas impermeability) nificantly below the natural level of 21 percent by
and the type of assets to be protected. The size volume. Carbon dioxide in concentrations that can
of the pipe network and the location of the extin- extinguish fires can be harmful to life, and therefore
guishing nozzles are based on the risk area, while special safety measures are installed.
the extinguishing nozzles themselves are evenly The extinguishing process will not start until after
distributed throughout the entire flooding zone. a predetermined warning time, so that there is suf-
For the protection of special facilities, the nozzles ficient time to leave the room. All warning compo-
are installed directly within the object, such as in nents are provided two-fold and are connected to
electric switching cabinets, false floors for cables different power sources.
or machine tools.
If several flooding zones are connected to a
common extinguishing agent supply, the gas is
released for each zone via selector valves.
3
Storage
High-pressure steel cylinders or low pressure vessels
The carbon dioxide is supplied in high-pressure extended protection zones or quick replacement
cylinders or low-pressure vessels. The optimum sup- of individual cylinders. Each cylinder suspension is
ply method depends on the quantity of gas required also a weighing unit, which automatically indicates
and the individual situation. minimal leakage of extinguishing agent. Functional
readiness and operational safety Neuralgic functions
Supply of extinguishing agent in and components of the extinguishing system, such
high-pressure steel cylinders as the gas quantity, shutoff, release and distribution
The high-pressure steel cylinders are consolidated units, are monitored to ensure the constant functio-
into one cylinder bank at the installation location nal readiness of the extinguishing system.
in special frames with independent suspension.
Arranged in one or more rows, surprisingly large
supplies of gas can be stored in a very small space.
The special frames can easily be adapted for
13
12
11
1 Cylinder bank
5 Selector valve
6 Changeover valve
8 9
7 Fire detection and
control panel 7
8 Disable device 6
5
9 Pneumatic door
release unit
3
4
10 Pneumatic horn 2
11 Electric horn
1
12 Room protection nozzle
4
Storage in low-pressure vessels Danger detected
If large quantities of extinguishing agent are The control and monitoring of the carbon dioxide
needed for the overall safety concept, a low-pressure extinguishing systems is provided by the Minimax
vessel is recommended – especially on fire detection system. Fire detectors monitor the
grounds of economy. The liquefied carbon dioxide protected zone. If the system detects smoke, an
is stored in this vessel at a temperate of approx. excessive rise in temperature or flames, the fire
–20 °C and at an operating pressure of approx. detection control panel initiates the extinguishing
20 bar. A cooling unit provides a constant low process.
temperature. The operating costs are minimized
by an optimum insulation design. The supply vessel
is mounted on a calibratable electronic weighing
unit, which constantly displays the actual weight
and therefore any potential loss of gas due to
leaks.
Flooding zone 1
(room protection)
17
14
15
Flooding zone 2
(local application)
16
5
14 Electric horn
Pneumatic control device
5 4 2
15 Room protection nozzle
6 Fire detection and
control panel 16 Local application nozzle
1
7 Main shut-off valve 17 Fire detection element
8 Safety valve
5
Compact modules -
Pre-fabricated for local application
6
Applications
A class of its own
rolling mills
turbines
transformers and substations
warehouses for hazardous materials
machine tools and special
metal processing systems
paint and varnish manufacturing
and processing areas
painting and powdercoating booths (ESTA)
hydraulic systems
false floors and cable shafts
silos and dust filters
printing machines
engine test benches and
ship engine compartments
switching and control systems
7
Advantages
Suitable both for the protection of rooms Documented reliable extinguishing provides
and of free-standing objects. maximum protection of assets.
Carbon dioxide is a natural component The system technology for the components
of the ambient air and is therefore has been tried and tested for decades.
readily available.
The modular, multi-zone system can easily be
Extinguishes without residue and without adapted for nearly any renovation or
affecting the protected objects. expansion measures.