ADNOC Classification: Internal

CHINA PETROLEUM ENGINEERING & CONSTRUCTION


CORPORATION
ABU DHABI BRANCH
P.O. BOX: 127345, Al Reem Island Abu Dhabi – UAE
WAFRA Square Offices 5th Floor
Tel.: +971-2-2013333 (Operator) Fax: +971-2-6787799
E-Mail: cpecc@cpecc.ae Web Site www.cpecc.cn

HABSHAN SS-7 AND SS-18 SWITCHGEAR UPGRADE PROJECT NO. 0401409

DOCUMENT TRANSMITTAL
Company : ADNOC GAS Processing Location: Habshan SS-7 & SS-18
Agreement No. : 4700012514 Project Number: 0401409

Contractor : China Petroleum Engineering & Construction Corporation

CPECC Transmittal No: 0401409-CPECC-T-1002 01-July-22

Your Ref (If any):

To : ADNOC Gas Processing Reply required : Review / Approval


Please find enclosed the documents for your

Information and Record Review & Comments Necessary Action

Approval Construction / Implementation / Purchase / Design

Item No. Document Reference No. Rev Revision Document Title/ Description Doc. Type of Number Doc. Cat
Date Status* Document ** of copies Class

1 SPP-0401409-GG-01-15-24-014 1 29-Jun-22 DATA SHEET FOR TELECOM IFD S 1


AND FIBER OPTIC CABLE

01-July-22
Project Manager Date
Please return a signed copy to acknowledge receipt

Stamp
Name & Signature Date
Note: * Status Description
ICR - Issued For Client Review IFA - Issued For Approval IFC - Issued For Construction
IFI - For Information Only As Built - As Built drawing IFP –Issued for Purchase
IFM – Issued for Implementation IFV – Issued for Void IFD- Issued for Design

** Type of Document Description S - Soft Copy H - Hard Copy

Approval of the document & drawing by the Company doesn't relieve the Contractor to follow Company requirements in line to DGS, standard documents &
guidelines etc. and standard Industry practices
ADNOC Classification: Internal

HABSHAN SS-7 AND SS-18 SWITCHGEAR UPGRADE PROJECT NO. 0401409


AGREEMENT NO. 4700012514
COMMENTS RESOLUTION SHEET (CRS)

AGP (Aconex) TRS/CRS Date:


AGP Doc. No. SPP-0401409-GG-01-15-24-014 Rev: A Transmittal ADNOCGP-WTRAN-000505
Ref No. 11/03/2022
CPECC TL Date:
Doc. Title: DATASHEET FOR TELECOM & FIBER OPTIC CABLE Transmittal CPE&CC-WTRAN-000174 04/02/2022
Ref No.

ADNOCGP-WTRAN-000503
STATUS CODE: Code 1: Rejected; Revise and Resubmit; Code 2: Comments as noted; Code 3: No Comments / Approved; Code 4: Information only

Section / Page Remark


S/N COMPANY COMMENTS CONTRACTOR REPLY
Ref. ADNOCGP-WTRAN-000503 (COMPANY)
1. ADNOCGP- Add the flame retardant /Fire resistant details as per the IEC in the Noted and updated
WTRAN-000505 cable test properties for FO cable.
2. ADNOCGP- Complied
WTRAN-000505 All cables should be LSZH
ADNOCGP-WTRAN-000503
3.
4.
5.
ADNOCGP-WTRAN-000503

ADNOCGP-WTRAN-000503

ADNOCGP-WTRAN-000503
ADNOC Classification: Internal

HABSHAN SS-7 AND SS-18 SWITCHGEAR UPGRADE PROJECT NO. 0401409


AGREEMENT NO. 4700012514
COMMENTS RESOLUTION SHEET (CRS)

AGP (Aconex) TRS/CRS Date:


AGP Doc. No. SPP-0401409-GG-01-15-24-014 Rev: B Transmittal ADNOCGP-WTRAN-001077
Ref No. 08/06/2022
CPECC TL Date:
Doc. Title: DATASHEET FOR TELECOM & FIBER OPTIC CABLE Transmittal CPE&CC-WTRAN-000413 11/03/2022
Ref No.

ADNOCGP-WTRAN-000503
STATUS CODE: Code 1: Rejected; Revise and Resubmit; Code 2: Comments as noted; Code 3: No Comments / Approved; Code 4: Information only

Section / Page Remark


S/N COMPANY COMMENTS CONTRACTOR REPLY
Ref. ADNOCGP-WTRAN-000503 (COMPANY)
1. Sheet 1 of 9 Class and category to be checked and updated. Noted and updated
2. Sheet 9 of 9 FO Cable requirements - Type and No. of core shall be checked with Noted, FO cores are considered for IPCS
Electrical discipline and coordinated for IPCS signals and differential and Differential protection, Refer FO Cable
relay protection through OEM. Network block diagram for details regarding
ADNOCGP-WTRAN-000503
the allocation, Doc no. 0401409-GG-01-15-
80-053

ADNOCGP-WTRAN-000503

ADNOCGP-WTRAN-000503

ADNOCGP-WTRAN-000503
ADNOC Classification: Internal

HABSHAN SS-7 AND SS-18 SWITCHGEAR UPGRADE PROJECT NO. 0401409


AGREEMENT NO. 4700012514
COMMENTS RESOLUTION SHEET (CRS)

AGP (Aconex) ADNOCGP-WTRAN-002631 TRS/CRS Date:


AGP Doc. No. SPP-0401409-GG-01-15-24-014 Rev: 0 Transmittal
Ref No. 29/06/2022
CPECC TL Date:
Doc. Title: DATASHEET FOR TELECOM & FIBER OPTIC CABLE Transmittal CPE&CC-WTRAN-000993 21/06/2022
Ref No.

STATUS CODE: Code 1: Rejected; Revise and Resubmit; Code 2: Comments as noted; Code 3: No Comments / Approved; Code 4: Information only

Section / Page Remark


S/N COMPANY COMMENTS CONTRACTOR REPLY
Ref. (COMPANY)
ADNOCGP- Document reissued to capture the FO cable change
WTRAN-002631 from 24 Core FO cable to 48 core FO cable, for Process
network systems (IPCS, F&G, DCS).
1. Sheet 1 of 9 In which document data sheet for the Communication The CAT 6 cables required for IPCS system will be
cables shall be covered used for IPCS system. i.e. - supplied by the System vendor, by following the details
Cat6A / Cu cables (Modbus TCP/IP protocol & IEC mentioned in this Datasheet.
61850 Protocol), FO Patch cords, GPS antenna cables GPS antenna cables for IPCS system shall be Vendor
for IPCS system etc. standard cable, Relevant Vendor supplied cable details
will be captured in the material submittal document
produced by Vendor, during the detail engineering.
2. Sheet 1 of 9 Ensure that Separate redundant FO cables are used Redundant FO routing is considered for each FO cable
IPCS system and differential protection system. IPCS route as part of Project scope.
system and Electrical protection system cables should Fiber optic cables considered for IPCS and Electrical
not be combined/same. protection system is common. However, separate Fiber
cores are considered for IPCS signals and Electrical
protection systems, in both the redundant FO cables.

3. ADNOCGP- Electrical design is not finalized for OLPD, OLCMS, SS 24 Core FO cable changed from to 48 Core type.
WTRAN-002631 12 and IPCS system. Hence, to finalized one type of FO 48 Core redundant FO Cable is considered for the IPCS
cable without finalizing the design is the Risk. and electrical protection systems network with sufficient
spares, instead of previously considered 24 Core FO
Cable. Further core allocations are also segregated
redundantly with refer to the system requirements.
In the response no details are shown for
SS 12 FO cables as required, to be
clarified and updated accrodingly.
CPECC has requested separate meeting for
telecom and FO cables to discuss, related
changes to be discussed and covered same in
adat sheet as applicable after meeting in next
week.

HABSHAN SS-7 AND SS-18 SWITCH GEAR UPGRADE


AGP PROJECT NO. 0401409
AGREEMENT NO. 4700012514

DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE

NOTICE:

THIS DOCUMENT AND THE INFORMATION IT CONTAINS IS THE SOLE PROPERTY OF


ABU DHABI GAS INDUSTRIES LTD (TRADING AS ADNOC GAS PROCESSING). IT SHALL
NOT BE REPRODUCED OR LENT WITHOUT THE AGREEMENT OF THE OWNER

TITLE
1 29- Jun-2022 Reissued for design (IFD) ZY MG AM DATASHEET FOR TELECOM
0 06- Jun-2022 Issued for design (IFD) ZY MG AM AND FIBRE OPTIC CABLE
DOC
B 11- Mar-2022 Issued for Approval (IFA) ZY MG AM CONTRACTOR PROJECT NO.
CLASS
A 04-Feb-2022 Issued for Client Review (ICR) ZY MG AM 1 0401409
DOC
CHECKED CATEG PROJECT DOCUMENT NO. SHEET REV
Rev Date REVISION DESCRIPTION PREP BY APPD BY ORY
BY
2 SPP-0401409-GG-01-15-24-014 1 of 10 1
1 Notes
2 1. The datasheet shall be read in conjunction with Project Specification documents.
3 2. FO cable system requirements, inpsection, testing shall be in accordance with COMPANY standards and specifications.
4 3. 24 and 48 core FO cable shall be used as backbone cable and 4 core FO shall be used for outdoor CCTV purpose. 1
5 4. The cable shall be continuous with no splicing permitted in between on any fiber in a drum length of the cable.
6 5. Vendor shall provide the technical datsheets of all Telecom system cables for review and approval of COMPANY.
7 6. VTA- Vendor to Advise
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

Document Title: Project No. : 401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 2 OF 10
1
2
3 DATASHEET FOR FIBRE OPTIC CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
6 Cable Type Single mode fiber optic cable
7 Number of cores 4 core / 24 & 48 Core (Note 3) 1
(1) 4 Core FO cable for outdoor PTZ CCTV camera
8 Application (2) 24 Core FO Cable for Telecom Backbone network
(3) 48 Core FO Cable for Process Backbone network 1
9 Fiber Optic Cable Composition

10 Applicable Standards ITU-T G.652 D, IEC 60793, IEC 60794-1, IEC 60332

11 Fiber Type Flame retardant Single mode


12 Fiber Core diameter (8.6 - 9.5) +/- 0.6 micron or better at 1310 nm
13 Cable Core Filled
14 Operating Wavelength nm 1310 & 1550
15 Cut-off Wavelength nm <1260

16 Core Glass Diameter 9 to 10/125 µm Single mode step index profile


µm

Cladding Diameter 125 µm +/- 0.7 µm

Anti- vermin and UV resistant, heat oil and flame


19 Outer Sheaths
retardant

20 Central Strength Element Glass reinforced plastic (GRP) rod or equivalent

21 Fiber Identification Color coded fiber tubes, As per TIA/EIA -598C

22 Fiber Tube Extruded tubes, jelly filled for longitudinal tightness

23 Min Core in a tube Nos. 4 nos.


24 Max outer diameter of buffer tubes mm 3 mm
Outer Strength Member Aramid Yarn, around the buffer tubes
Polyethylene, LSZH Flame Retardant compound.
25 Inner jacket
Colour: Black
Non-leaded hydrocarbon Resistant, Moisture Barrier
26 Fiber Sheath
with Metallic Tape
27 Bedding Polyethylene, LSZH, Color: Black
Galvanized steel wires or Equivalent strength Steel
28 Armor
Tape Armour
30 Outer jacket Flame retardant Polyethlyene, LSZH,Color: Black

31 Cable marking Durable marking embossed every one meter


32 Fiber Optic Cable Test Properties
33 Splice Attenuation dB ≤ 0.10 dB/splice (VTA)
34 Core concentricity error µm 0.6 µm
Cladding Non- circularity 1%
Numerical Aperture 0
35 Connector Loss ≤0.50 dB/ connector (VTA)
36 PMD Coefficient ps/√km ≤0.06 (VTA)
37 Cut-off Wavelength nm λcc≤1260nm
38 Max. Attenuation coefficient at 1310 nm dB/km ≤0.4
Max. Attenuation coefficient at 1550 nm dB/km ≤0.25
Chromatic dispersion @1310 nm VTA
39 Chromatic dispersion @1550 nm VTA
40 Zero dispersion wavelength 1300 - 1324 nm
41 Polarization mode dispersion at 1310 &1550nm <0.2 ps/km² for fiber: <0.3 ps/km² for cabled fiber
42 Water Penetration Resistance Required as per IEC 60793-1-53
Bending radius under force during installation (
43 15xD, D=Cable Diameter
Full Load)
44 Bending radius Installed ( No Load) 10 X D, D= Cable Diameter

45 Repeated Bending 30 Cycle, 20xD, 5 Kg Load, D=Cable Diameter


46 Torsion Strength 10 Cycle (+- 180deg) 5 kg Weight, L=2Mtr
47 Impact Resistance 25N-m, 3 No’s at different place
48 Max. Pulling Force kN VTA
49 Tensile Force N 2000N
50 Crush Resistance 3000N (100x100mm) for 60sec
51 Kink resistance 10xD, D=Cable Diameter
52 Cable drum length Km 4 Kms
53
54
55

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 3 OF 10
1
2
3 DATASHEET FOR FIBRE OPTIC CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
6 Test Performed During Production Process
7 Comprehensive Strength(IEC 60794-1-2-E3) N/cm 300 N/cm
Torsion Strength As per IEC 60794-1-2-E7
Crush Resistance As per IEC 60794-1-2-E3
8 Impact Resistance (IEC 60794-1-2-E4) N.m 50 N.m
9 Cable Twist (IEC 60794-1-2-E7) 10 cycles, 180° Twisting, 2.5 meter sample
10 Tensile Load (IEC 60794-1-2-E1) N Static 1000N : Dynamic 4000N
11 Water Penetration (IEC 60794-1-2-F5B) 3 meter sample, 1 meter water preassure, 24 Hours
12 Compound Flow Test (IEC 60794-1-2-B1) No drip at 70ºC

13 Repeated Bending (IEC 60794-1-2-E6) 6 Cycles with 20 x OD bending radius

14 Temperature Cycling (IEC 60794-1-2-F1) -15°C TO 60°C

15 Jacket Dimension Strength (IEC 60708-1) N/MM 1.8N/MM


16 Bend Radius IEC 60794-1-2-E11 cm Armoured : 15 X OD (Static) 20 X OD (Dynamic)
Flame Retardant Test IEC-60332
Optical Testing - Single mode ITU-T G.652D

17 Fiber Optic Cable Physical Properties

18 Drum identification levels Required

19 Cable Outer Diameter VTA


mm
20 OTDR Measurement test km Required
21 End to End attenuation test Required
Diff. in attenuation coefficienet when measured at both
22 VTA
end
23 Number of Buffer and Fiber per Loose tube VTA

24 Central Strength Diameter VTA

25 Minimum installation temperature VTA

26 Ambient Temperature (Min / Max) -30 to +70


Deg C
27 Operating temperature Range VTA

28 Cable weight VTA

29 Life Expectancy Years 30 Plus years


30 Manufacturer VTA
31 Model No. VTA
32
33
34
35
36
37
38
39

40

41

42
43
44
45
46
47
48
49
50
51

52

53
54
55

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 4 OF 10
1
2
3 DATASHEET FOR TELEPHONE CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
Multi Pair Collectively screened, SWA, Lead
6 Sheathed, Flame retardant jacket and jelly filled.
Cable Type
7 4 pair (P) x 0.75 sq.mm cable
Cable configuration
Outdoor Telephone signal cable ( between
8 Telephone Distribution box(SS-7A) and outdoor
Application telephone)
9 Multi Pair Cable Composition / Construction
IEC 60228,EN 50290-2-29, BS EN 12548, EN
10 Applicable standards
10257-1

11 Conductor Solid annealed copper


Flame Retardant Cross-Linked Polyethylene
12 Insulation
(FR-XLPE)
13 Color code As per BS 5308 Part 1
14 Pair Construction Twisted pair insulated conductors
Required, Aluminium, Copper drain wire and,
15 Collective Screen Polyester tape overall screening with inner
sheath
Flame retardant, Low Smoke Zero Halogen
16 Inner Sheath
Compound, Black color.
17 Lead Sheath Lead alloy type, as per BS EN 12548
Low Smoke Zero Halogen Compound, Black
18 Bedding
color.
19 Armour Galvanized steel wire,as per EN 10257-1
Flame retardant Low Smoke Zero Halogen
20 Outer Sheath
Compound, Grey with white trace color.
21 Embosing on sheath Required as per BS EN 50288-7 & IEC 60332-3

22 Electrical Parameters / Technical Data

23 Operating Temperature -15°C to 90°C


24 Voltage Rating 500 Volts
25 Conductor Resistance (at 20°C) VTA
26 Mutual Capacitance (at 1kHz) VTA
27 Capacitance Unbalance (at 1kHz) VTA
28 L/R Ratio VTA
29 Insulation Resistance VTA
Dielectric Strength Test (core to core &
30 VTA
core to screen)
31 General Characteristics
32 Flame retardant As per IEC 60332-3
33 Halogen Acid Gas (Outer Sheath) Required, As per IEC 60754-1
34 Limiting Oxygen Index (Outer Sheath) Required, As per BS 2782 part 1
35 UV / Sunlight Resistance (Outer Sheath) Required

36 Oil Resistance (Outer Sheath) Required, As per IEC 60811-404

37 Min. Bending Radius VTA

38 Weight per unit kilometer Kg/Km VTA


39 Dimensional Data
40 Pair 4P
41 Size Sq.mm 0.75
42 Inner Sheath Thickness mm VTA
43 Insulation Thickness mm VTA
44 Diameter over inner sheath mm VTA
45 Lead Sheath Thickness mm VTA
46 Diameter Over Lead Sheath mm VTA
47 Bedding Thickness mm VTA
48 Diameter over bedding mm VTA
49 Armour Wire Diameter mm VTA
50 Outer Sheath Thickness mm VTA
51 Overall Diameter mm VTA
52 Model No. VTA
53 Manufacturer VTA
54
55

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 5 OF 10
1
2
3 DATASHEET FOR TELEPHONE CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
Multi Pair Collectively screened, Steel wire armoured, Non
6 Cable type
Lead Sheathed, Flame retardant jacket and jelly filled

7 Cable configuration 20 pair (P) x 0.9 sq.mm cable (19AWG)

Outdoor Telephone signal cable ( between Telephone


8 Application
cabinet /JB ( SS-07) and distribution box (SS-7A)

9 Multi Pair Cable Composition / Construction


IEC 60228,EN 50290-2-29,BS EN 50290-2-22, BS EN
10 Applicable standards
12548, EN 10257-1, BS EN 50290-2-22
11 Conductor Solid annealed copper
Flame Retardant Cross-Linked Polyethylene
12 Insulation
(FR-XLPE)
13 Color code As per BS 5308 Part 1

14 Pair Construction Twisted pair insulated conductors

Required, Aluminium, Copper drain wire and, Polyester


15 Overall Screen
tape overall screening with inner sheath

Flame retardant, Low Smoke Zero Halogen Compound,


16 Inner Sheath
Black color.
17 Lead Sheath Not Applicable

18 Bedding Low Smoke Zero Halogen Compound, Black color.

19 Armour Galvanized steel wire,as per EN 10257-1


Flame retardant Low Smoke Zero Halogen Compound,
20 Outer Sheath
Grey with white trace color.

21 Embosing on sheath Required as per BS EN 50288-7 & IEC 60332-3

22 Electrical Parameters / Technical Data

23 Operating Temperature -15°C to 90°C


24 Voltage Rating 500 Volts
25 Conductor Resistance (at 20°C) VTA
26 Mutual Capacitance (at 1kHz) VTA
27 Capacitance Unbalance (at 1kHz) VTA
28 L/R Ratio VTA
29 Insulation Resistance VTA
Dielectric Strength Test (core to core &
30 VTA
core to screen)
31 General Characteristics
32 Flame retardant dB As per IEC 60332-3
33 Halogen Acid Gas (Outer Sheath) Required, As per IEC 60754-1
34 Limiting Oxygen Index (Outer Sheath) ps/√km Required, As per BS 2782 part 1
35 UV / Sunlight Resistance (Outer Sheath) Required

36 Oil Resistance (Outer Sheath) Required, As per IEC 60811-404

37 Minimum Bending Radius VTA


kN
38 Weight per unit kilometer Kg/Km VTA
39 Dimensional Data
40 Pair 20P
41 Size Sq.mm 0.9 sqmm
42 Inner Sheath Thickness mm VTA
43 Insulation Thickness mm VTA
44 Diameter over inner sheath mm VTA
45 Lead Sheath Thickness mm Not Applicable
46 Diameter Over Lead Sheath mm Not Applicable
47 Bedding Thickness mm VTA
48 Diameter over bedding mm VTA
49 Armour Wire Diameter mm VTA
50 Outer Sheath Thickness mm VTA
51 Overall Diameter mm VTA
52 Model No. VTA
53 Manufacturer VTA
54
55

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 6 OF 10
1
2
3 DATASHEET FOR TELEPHONE CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
Multi Pair Collectively screened, Unarmored
6 Cable Type
and LSZH Flame Retardant.
7 Cable configuration 2 pair (P) x 0.75 sq.mm cable
Indoor Telephone signal cable ( between
8 Application Telephone distribution box and indoor
telephone)
9 Multi Pair Cable Composition / Construction
10 Applicable standards IEC 60228, EN 50288-7
11 Conductor Solid annealed copper
Flame retardant Cross Linked Polyethylene
12 Insulation
(XLPE)
13 Color code As per BS 5308 Part 1

14 Pair Construction Twisted pair insulated conductors


Required, Aluminium, Copper drain wire and,
15 Collective Screen Polyester tape overall screening with inner
sheath
Flame retardant moisture resistant
16 Filler
material,VTA
Flame retardant Low Smoke Zero Halogen
17 Outer Sheath
Compound, Grey with white trace color.
Required as per BS EN 50288-7 & IEC 60332-
18 Embosing on sheath
3
19 Electrical Parameters / Technical Data

20 Operating Temperature -15°C to 90°C


21 Voltage Rating 500 Volts
22 Conductor Resistance (at 20°C) VTA
23 Mutual Capacitance (at 1kHz) VTA
24 Capacitance Unbalance (at 1kHz) VTA
25 L/R Ratio VTA
26 Insulation Resistance VTA
Dielectric Strength Test (core to core &
27 VTA
core to screen)
28 General Characteristics
29 Flame retardant As per IEC 60332-3
30 Halogen Acid Gas (Outer Sheath) Required, As per IEC 60754-1
31 Limiting Oxygen Index (Outer Sheath) Required, As per BS 2782 part 1
32 UV / Sunlight Resistance (Outer Sheath) Required

33 Oil Resistance (Outer Sheath) Required, As per IEC 60811-404

34 Min. Bending Radius VTA


mm
35 Weight per unit kilometer Kg/Km VTA
36 Dimensional Data
37 Pair 2P
38 Size Sq.mm 0.75
39 Inner Sheath Thickness mm VTA
40 Insulation Thickness mm VTA
41 Outer Sheath Thickness mm VTA
42 Overall Diameter mm VTA
43 Model No. VTA
44 Manufacturer VTA
45
46
47
48
49
50
51
52
53
54
55

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 7 OF 10
1
2
3 DATASHEET FOR PAGA CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
Multi Pair Collectively screened, Unarmoured and Fire
6 Cable type
resistant
(1) 1 pair (P) x 2.5 sq.mm cable
7 Cable configuration
(2) 1 pair (P) x 1.5 sq.mm cable
(1) PAGA cable for indoor loudspeaker loop cable
8 Application (2) PAGA cable for indoor loudspeaker pig tail between
local JB and speakers
9 Multi Pair Cable Composition / Construction

10 Applicable standards IEC 60228,EN 50290-2-29, IEC 60332-3,IEC 60331-21

11 Conductor Solid annealed copper

Mica impregnated glass tape beneath extruded layer of


12 Insulation
Cross linked polyethylene (XLPE)
13 Color code Single pair black and white
14 Pair Construction Twisted pair insulated conductors
15 Insulating Tape Glass - Silk and polyester

Required, Aluminium, Copper drain wire and, Polyester


16 Overall Screen
tape overall screening with inner sheath

Flame retardant, Low Smoke Zero Halogen, Grey with


17 Outer Sheath
violet trace color.

18 Embosing on sheath Required as per BS EN 50288-7 & IEC 60332-3

19 Electrical Parameters / Technical Data

20 Operating Temperature -15°C to 90°C


21 Voltage Rating 500 Volts
22 Conductor Resistance (at 20°C) VTA
23 Mutual Capacitance (at 1kHz) VTA
24 Capacitance Unbalance (at 1kHz) VTA
25 L/R Ratio VTA
26 Insulation Resistance VTA
Dielectric Strength Test (core to core &
27 VTA
core to screen)
28 General Characteristics
29 Flame retardant As per IEC 60332-3
30 Fire resistance As per IEC 60331-21
31 Halogen Acid Gas (Outer Sheath) Required, As per IEC 60754-1
32 Limiting Oxygen Index (Outer Sheath) ps/√km Required, As per BS 2782 part 1
33 UV / Sunlight Resistance (Outer Sheath) Required

34 Oil Resistance (Outer Sheath) Required, As per IEC 60811-404

35 Minimum Bending Radius VTA


kN
36 Weight per unit kilometer Kg/Km VTA
37 Dimensional Data
38 Pair 1P
39 Size Sq.mm 1.5 & 2.5 sqmm
40 Insulation Thickness mm VTA
41 Strand diameter mm VTA
42 Outer Sheath Thickness mm VTA
43 Overall Diameter mm VTA
44 Model No. VTA
45 Manufacturer VTA
46
47
48
49
50
51
52
53
54
55

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 8 OF 10
1
2
3 DATASHEET FOR PAGA CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
6 Cable Type Multi Pair Collectively screened, Armoured, Fire resistant

(1) 4 pair (P) x 2.5 sq.mm cable


7 Cable description (2) 1 pair (P) x 2.5 sq.mm cable
(3) 1 pair (P) x 1.5 sq. mm cable

(1) PAGA cable between system cabinet and Juntion Box ( SS-7)
(2) PAGA cable for outdoor loudspeaker loop cable
8 Application
(3) PAGA cable for outdoor loudspeaker pig tail between local JB
and speakers

9 Multi Pair Cable Composition / Construction

IEC 60228,EN 50290-2-29, BS EN 12548, EN 10257-1, IEC


10 Applicable standards
60332-3, IEC 60331-21

11 Conductor Solid annealed copper


Mica impregnated glass tape beneath extruded layer or
12 Insulation
polyethylene
13 Color code Single pair black and white

14 Pair Construction Twisted pair insulated conductors

Required, Aluminium, Copper drain wire and, Polyester tape


15 Collective Screen
overall screening with inner sheath
Low smoke zero halogen, Black color, as per BS EN 50290-2-
16 Inner Sheath
27.
17 Lead Sheath Lead alloy type, as per BS EN 12548
Low Smoke Zero Halogen, Black color,as per BS EN 50290-2-
18 Bedding
22.

19 Armour Galvanized steel wire,as per EN 10257-1

Flame retardant , Low smoke Zero Halogen,as per BS EN 50290-


20 Outer Sheath
2-27. Grey with violet trace color.

21 Embosing on sheath Required as per BS EN 50288-7 & IEC 60332-3

22 Electrical Parameters / Technical Data

23 Operating Temperature -15°C to 90°C


24 Voltage Rating 500 Volts
25 Conductor Resistance (at 20°C) VTA
26 Mutual Capacitance (at 1kHz) VTA
27 Capacitance Unbalance (at 1kHz) VTA
28 L/R Ratio VTA
29 Insulation Resistance VTA
Dielectric Strength Test (core to core &
30 VTA
core to screen)
31 General Characteristics
32 Flame retardant As per IEC 60332-3
33 Fire Resistance As per IEC 60331-21
34 Halogen Acid Gas (Outer Sheath) Required, As per IEC 60754-1
35 Limiting Oxygen Index (Outer Sheath) Required, As per BS 2782 part 1
36 UV / Sunlight Resistance (Outer Sheath) Required

37 Oil Resistance (Outer Sheath) Required, As per IEC 60811-404

38 Min. Bending Radius VTA

39 Weight per unit kilometer Kg/Km VTA


40 Dimensional Data
41 Pair 4P & 1P
42 Size Sq.mm 1.5 & 2.5 sqmm
43 Strand diameter mm VTA
44 Inner Sheath Thickness mm VTA
45 Insulation Thickness mm VTA
46 Diameter over inner sheath mm VTA
47 Lead Sheath Thickness mm VTA
48 Diameter Over Lead Sheath mm VTA
49 Bedding Thickness mm VTA
50 Diameter over bedding mm VTA
51 Armour wire Diameter mm VTA
52 Outer Sheath Thickness mm VTA
53 Overall Diameter mm VTA
54 Model No. VTA
55 Manufacturer VTA

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 9 OF 10
1
2
3 DATASHEET FOR NETWORK CABLE
4
5 DESCRIPTION UNIT DESIGN DATA VENDOR DATA
Shielded twisted pair CAT6A and CAT 7 network
6 Cable Type
cable, Unarmoured, Flame retardant
7 Cable description Category 6A / 7, 0.25 sq.mm cable
CAT 6A for Indoor CCTV Camera, Access Control
8 Application
and CAT 7 for LAN & IP Telephones
9 Multi Pair Cable Composition / Construction
10 Applicable standards IEC 60332
11 Conductor Solid annealed copper
Flame retardant Cross Linked Polyethylene
12 Insulation
(XLPE)
White/Blue, White/Orange, White/Green,
13 Color code
White/Brown
Twisted pair insulated conductors, 4Px2CX 23
14 Pair Construction
AWG
15 Inner Screen Twisted pair Aluminium Foil
16 Outer Screen Tinned copper wire braid
Low smoke Zero Halogen, UV resistant and Flame
17 Jacket Material
retardant

18 Rip Chord Required, under jacket

19 Filler Flame retardant moisture resistant material,VTA

20 Outer Sheath Low Smoke Zero Halogen - Grey

21 Embosing on sheath Required as per IEC 60332-3

22 Electrical Parameters / Technical Data

23 Operating Temperature -15°C to 90°C


24 Operating Frequency Mhz 550 Mega hertz
25 Voltage Rating V 150 Volts
26 DC Resistance (at 20°C) max Ω/100 mVTA
27 Resistance unbalance % VTA
28 Capacitance Unbalance (at 1kHz) max pF/km VTA
29 Mutual Capacitence VTA
30 Impedence Ω VTA
31 Insulation resistance VTA

32 Dielectric strength of conductor VTA

33 General Characteristics
34 Flame retardant As per IEC 60332-3
35 Halogen Acid Gas (Outer Sheath) Required, As per IEC 60754-1
36 Limiting Oxygen Index (Outer Sheath) Required, As per BS 2782 part 1
37 UV / Sunlight Resistance (Outer Sheath) Required
38 Min. Bending Radius mm VTA
39 Drum length mm VTA
40 Weight per unit kilometer Kg/Km VTA
41 Dimensional Data
42 Pair 4P
43 Size Sq.mm 0.25
44 Insulation Thickness mm VTA
45 Outer Sheath Thickness mm VTA
46 Overall Diameter mm VTA
47 Model No. VTA
48 Manufacturer VTA
49
50
51
52
53
54
55

Document Title: Project No. : 0401409


Doc.No.: SPP-0401409-GG-01-15-24-014
DATASHEET FOR TELECOM AND FIBRE OPTIC CABLE Rev. 1
Page 10 OF 10

You might also like