Professional Documents
Culture Documents
Spp-0401409-Gg-01!15!24-014 - Rev1 - Datasheet For Telecom and Fiber Optic Cable
Spp-0401409-Gg-01!15!24-014 - Rev1 - Datasheet For Telecom and Fiber Optic Cable
DOCUMENT TRANSMITTAL
Company : ADNOC GAS Processing Location: Habshan SS-7 & SS-18
Agreement No. : 4700012514 Project Number: 0401409
Item No. Document Reference No. Rev Revision Document Title/ Description Doc. Type of Number Doc. Cat
Date Status* Document ** of copies Class
01-July-22
Project Manager Date
Please return a signed copy to acknowledge receipt
Stamp
Name & Signature Date
Note: * Status Description
ICR - Issued For Client Review IFA - Issued For Approval IFC - Issued For Construction
IFI - For Information Only As Built - As Built drawing IFP –Issued for Purchase
IFM – Issued for Implementation IFV – Issued for Void IFD- Issued for Design
Approval of the document & drawing by the Company doesn't relieve the Contractor to follow Company requirements in line to DGS, standard documents &
guidelines etc. and standard Industry practices
ADNOC Classification: Internal
ADNOCGP-WTRAN-000503
STATUS CODE: Code 1: Rejected; Revise and Resubmit; Code 2: Comments as noted; Code 3: No Comments / Approved; Code 4: Information only
ADNOCGP-WTRAN-000503
ADNOCGP-WTRAN-000503
ADNOC Classification: Internal
ADNOCGP-WTRAN-000503
STATUS CODE: Code 1: Rejected; Revise and Resubmit; Code 2: Comments as noted; Code 3: No Comments / Approved; Code 4: Information only
ADNOCGP-WTRAN-000503
ADNOCGP-WTRAN-000503
ADNOCGP-WTRAN-000503
ADNOC Classification: Internal
STATUS CODE: Code 1: Rejected; Revise and Resubmit; Code 2: Comments as noted; Code 3: No Comments / Approved; Code 4: Information only
3. ADNOCGP- Electrical design is not finalized for OLPD, OLCMS, SS 24 Core FO cable changed from to 48 Core type.
WTRAN-002631 12 and IPCS system. Hence, to finalized one type of FO 48 Core redundant FO Cable is considered for the IPCS
cable without finalizing the design is the Risk. and electrical protection systems network with sufficient
spares, instead of previously considered 24 Core FO
Cable. Further core allocations are also segregated
redundantly with refer to the system requirements.
In the response no details are shown for
SS 12 FO cables as required, to be
clarified and updated accrodingly.
CPECC has requested separate meeting for
telecom and FO cables to discuss, related
changes to be discussed and covered same in
adat sheet as applicable after meeting in next
week.
NOTICE:
TITLE
1 29- Jun-2022 Reissued for design (IFD) ZY MG AM DATASHEET FOR TELECOM
0 06- Jun-2022 Issued for design (IFD) ZY MG AM AND FIBRE OPTIC CABLE
DOC
B 11- Mar-2022 Issued for Approval (IFA) ZY MG AM CONTRACTOR PROJECT NO.
CLASS
A 04-Feb-2022 Issued for Client Review (ICR) ZY MG AM 1 0401409
DOC
CHECKED CATEG PROJECT DOCUMENT NO. SHEET REV
Rev Date REVISION DESCRIPTION PREP BY APPD BY ORY
BY
2 SPP-0401409-GG-01-15-24-014 1 of 10 1
1 Notes
2 1. The datasheet shall be read in conjunction with Project Specification documents.
3 2. FO cable system requirements, inpsection, testing shall be in accordance with COMPANY standards and specifications.
4 3. 24 and 48 core FO cable shall be used as backbone cable and 4 core FO shall be used for outdoor CCTV purpose. 1
5 4. The cable shall be continuous with no splicing permitted in between on any fiber in a drum length of the cable.
6 5. Vendor shall provide the technical datsheets of all Telecom system cables for review and approval of COMPANY.
7 6. VTA- Vendor to Advise
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
10 Applicable Standards ITU-T G.652 D, IEC 60793, IEC 60794-1, IEC 60332
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
(1) PAGA cable between system cabinet and Juntion Box ( SS-7)
(2) PAGA cable for outdoor loudspeaker loop cable
8 Application
(3) PAGA cable for outdoor loudspeaker pig tail between local JB
and speakers
33 General Characteristics
34 Flame retardant As per IEC 60332-3
35 Halogen Acid Gas (Outer Sheath) Required, As per IEC 60754-1
36 Limiting Oxygen Index (Outer Sheath) Required, As per BS 2782 part 1
37 UV / Sunlight Resistance (Outer Sheath) Required
38 Min. Bending Radius mm VTA
39 Drum length mm VTA
40 Weight per unit kilometer Kg/Km VTA
41 Dimensional Data
42 Pair 4P
43 Size Sq.mm 0.25
44 Insulation Thickness mm VTA
45 Outer Sheath Thickness mm VTA
46 Overall Diameter mm VTA
47 Model No. VTA
48 Manufacturer VTA