Son Pumphuse

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

SON PUMP HOUSE

MACHNE
FOUNDATON
DESIGN

TOTAL MACHINE
WEIGHT (in kg) 12235
TOTAL MACHINE
WEIGHT (in kn) 122.35
foundation size
G in Mts. 5.75
H in mts. 2.37

Area of Foundation
Block in m2 13.6275

Considering
Foundation weight
in KN 367.05

Assuming
foundation level on
pump side above
GL in mts. 0.5
considering soil
density in kn/m3 2.5

Weight of
foundation above
GL

DIMENSIONS IN
Mts.
A 0.56
B 1.108
C 1.968
D (assumed) 0.5
D1 0.608
E 0.3
(B+E) 1.408
F 1.168
G 2.37
G1 0.383
G2 1.604
H 5.75
I 0.95
J 1.4
K 0.24
L 1.655
M 0.715
N 0.015
P 0.288
Q 0.911
R 1.876
S 0.073
T 0.2
U 0.896
V 0.623
W 0.989
X 0.965
Y 1.27
Y1 0.55
Z 1.01
α 0.927
β 0.215
ϒ 1.105
ϑ 3.163
Ф 2.587

width of drive
machine base plate
in mts. 2.24

Thickness of drive
machine base plate
in mts. 0.306

Density of concrete
(KN/M3) 2.5

Acceleration due to
gravity (kg/m3) 9.81

Weight of
foundation above
G.L in KN 278.8862

Required
Foundation Height
below G.L in Mts. 0.2637941
Provide 0.3 mt.
below GL 0.3
Weight of
Foundation ;Wf 379.15053

Total Weight of
Machine +
Foundation =
Weight of
foundation + Total
machine Weight
Total machine
Weight:
Weight of motor
base shaft in kg 6000
Weight of base &
Pad 950
Weight of base
plate 11051.966
Total Machine
Weight in Kg 18001.966
Total Machine
Weight in KN 180.01966

Total Weight of
Machine +
Foundation 559.17019

Total Machine
Weight is to be
divided into 6
equal parts @
anchorages of base
plate
Wm1 30.00
Wm2 30.00
Wm3 30.00
Wm4 30.00
Wm5 30.00
Wm6 30.00

Similarly, Non Drive


Pump side (right
side):
Weight of Pump
Base Shaft in Kg 5090
Weight of base &
Pad in kg 1145
Total Weight in KN: 62.35

To be divided into
4 equal parts
@anchorages of
base plate
Wp1 15.5875
Wp2 15.5875
Wp3 15.5875
Wp4 15.5875

direct bearing
pressure in KN/m2 41.032485

Safe Bearing
Capacity as per soil
report in ton/m2 31

Safe Bearing
Capacity as per soil
report in KN/m2 304.0077

Ratio of bearing
pressure to bearing
capacity; 0.1349719

Margin for other


loads (dynamic
loads, emergency
loads etc.) in
Percentage 86.502814
Margin available >30% O.K