7/06 -GB-
cod. 9IS42066 ELECTRICAL WIRING
ID 974
DISPLAY ALARM
NOTE:
AH1 High temperature alarm (referred to
• UPLOAD: instrument —> Copy Card the thermostat probe or probe 1 Attention! Never work on electrical con-
• DOWNLOAD: Copy Card —> instrument. AL1 Low temperature alarm (referred to nections when the machine is switched on.
the thermostat probe or probe 1)
To silence alarms press any key.
The instrument is equipped with screw ter-
electronic controllers for “forced air” refrigeration units KEYBOARD LOCKING minal boards for connection of electrical
The instrument includes a facility for dis- cables with a diameter of 2.5 mm2 (one
abling the keyboard, by programming the conductor only per terminal for power
“Loc” parameter (see folder with “diS” connections).
label). If the keyboard is locked, you can ONLY FOR MODEL 8+8+15A + D.I.
For the capacity of the terminals, see the
still access the programming menu by
USER INTERFACE MACHINE STATUS MENU “DOWN” keys, and confirm with the “set” pressing the “SET” key.
DISPLAY ALARM label on the instrument.
EA External Alarm In the model ID 974 with Switching power
The user has a display and four keys for To access the “Machine Status” menu key to move to the next parameter. The Setpoint can also be viewed. OPd Open Door Alarm
Press and quickly release the “set” key. supply only one voltage free relay output
controlling status and programming of the
If alarms are not present, the label “SEt” PASSWORD is present, on all other models on the con-
instrument.
appears. By using the “UP” and “DOWN” The password allows access to program- DIAGNOSTICS trary all relay outputs are voltage free..Do
KEYS AND MENUS keys you can scroll through the other fold- ming parameters. In the standard configu- INSTALLATION not exceed the maximum current allowed;
in case of higher loads, use an appropriate
ers in the menu: ration password is not present. The alarm condition is always signalled by
UP key Scrolls through the menu -Pb1: probe 1 value folder; To enable and assign it the desired value, the buzzer (if present) and by the led of The instrument is designed for panel contactor. Make sure the power supply
items Increases the values
-Pb2: probe 2 value folder access the “Programming” menu, within mounting. Make a hole of 29x71 mm, voltage complies with the one required by
Activates manual def. function the instrument.
-SEt: Setpoint setting folder. the folder with the “diS” label. If pass- the alarm icon insert the instrument and fix it using the
DOWN key Scrolls through the menu items Set Setting word is enabled, you will see it at the The alarm signal produced by a faulty brackets provided. Do not mount the In 12V versions the power supply must be
Decreases the values
Access the “Machine Status” menu by entrance of the “Programming” menu. thermostat probe (referred to probe 1) instrument in humid and/or dirty places; it provided by a security transformer with
Programmable by parameter
pressing and quickly releasing the “set” is shown as E1 on the instrument display is suitable for use in ordinary polluted the protection of a delayed 250 mA fuse.
fnc key
fnc ESC function (exit) key. The label of the “SEt” folder appears. MANUAL ACTIVATION OF THE The alarm signal produced by a faulty places. Ventilate the place in proximity to Probes have no connection polarity and
Programmable by parameter To display the Setpoint value press the DEFROSTING CYCLE evaporator probe (probe 2) is shown as E2 the instrument colling slits. can be extended using a regular bipolar
set key Accesses the setpoint “set” key again. To manually activate the defrosting cycle, on the instrument display. cable (note that the extension of the
set Accesses the menus The value appears on the display. press the “UP” key for 5 seconds. probes affects the EMC electromagnetic
Confirms the commands To change the Setpoint value, use the “UP” If defrosting conditions are not present, Probe faults table compatibility of the instrument: pay
Displaying the alarms (if present)
and “DOWN” keys within 15 seconds. (for example the evaporator probe extreme attention to wiring).
If the parameter is LOC = y the Setpoint temperature is higher than defrost stop DISPLAY FAULT Probe cables, power supply cables and the
At start-up the instrument performs a cannot be changed. temperature), the display E1 Faulty probe 1 (thermostat) TTL serial cables should be distant from
Lamp Test; for few seconds the display and Alarm on will blink three (3) times, in order to E2 Faulty probe 2 (1st evaporator) power cables.
the leds blink, in order to verify their inte- If alarm condition exists, when accessing indicate that the operation will not be
If simultaneous, they will be showed on the display
grity and correct operation. The instru- The “Machine Status” menu the “AL” fold- performed. alternately, every 2 seconds
ment has two main menus: the “Machine er label appears (see the “Diagnostics” CONDITIONS OF USE
Status” and “Programming” menu. section). COPY CARD
Displaying Probes The Copy Card is an accessory connected PERMITTED USE
ACCESSING AND USING MENUS By pressing the “set” key when the appro- to the TTL serial port which allows pro- The error condition of the probe 1 (ther- For safety reasons the instrument must be
Resources are arranged in a menu, which priate label appears, the value of the pro- gramming quickly the instrument parame- mostat) causes the following: installed and used according to the
can be accessed by pressing and quickly be associated to it is displayed. ters. The operation is performed as fol- • viewing E1 code on the display instruction provided and in particular,
releasing the “set” key (“Machine Status” lows: • compressor enabling as indicated by under normal conditions, parts bearing
menu) or by holding down the “set” key PROGRAMMING MENU “Ont” and “Oft” parameters, if these are dangerous voltage levels must not be
for more than 5 seconds (“Programming” To enter the “Programming” menu, press Fr-Format programmed for duty cycle or: accessible.
menu). the “set” key for more than 5 seconds. This command allows copy card formatting, The device must be adequately protected
To access the contents of each folder, indi- If specified, the access PASSWORD will be an operation recommended in case of first Ont Oft Compressor output from water and dust as per the application
cated by the relevant label, just press the requested, (parameter “PA1”), and the use. 0 0 OFF and must also only be accessible via the
“set” key once. label of the first folder will follow. Warning: if the copy card has been pro- 0 >0 OFF use of tools (with the exception of the
>0 0 ON
You can now scroll through the contents To scroll through the other folders, use grammed, using the “Fr” the data entered >0 >0 dc frontlet).
of each folder, modify it or use its func- the “UP” and “DOWN” keys. are erased. This operation cannot be can- The device is ideally suited for use on
tions. To enter the folder, press “set”. The label celled. household appliances and/or similar refrig-
If you do not use the keyboard for over of the first visible parameter appears. To The error condition of the probe 2 (evap- eration equipment and has been tested
15 seconds (time-out) or if you press the scroll through the other parameters, use UL-Upload orator) causes the following: with regard to the aspects concerning
“fnc” key once, the last value shown on the “UP” and “DOWN” keys; to change the This operation loads the programming • viewing E2 code on the display European reference standards on safety. It
the display is confirmed and you return to parameter, press and release “set”, then parameters from the instrument. • end of defrost because of time-out. is classified as follows:
the previous screen mask. set the desired value using the “UP” and Other signalling alarm are not shown on • according to its manufacture: as an auto-
dL-Download the instrument display, but from the matic electronic control device to be
LED This operation downloads to the instru- “Machine Status” menu within the “AL” incorporated by independent mounting;
ment the programming parameters. folder. The signals for maximum and mini- • according to its automatic operating fea-
Position Related Function Status The operations are performed accessing mum alarms do not appear on the instru- tures: as a 1 B-type operated control type;
Compressor or relay 1 ON when the compressor is started up; blinking in case of delay, the folder identified by the “FPr” label and ment display but are viewable on the • as a Class A device in relation to the cat-
protection or blocked enabling
selecting, according to the case, “UL”, “dL” “Machine Status” menu in the “AL” folder, egory and structure of the software
Defrost ON when defrosting; blinking in case of manual or “Fr” commands; the operation is con- with the label “AH1” or “AL1”. UNPERMITTED USE
enabling firmed by pressing the “set” key. If the The regulation of the maximum and mini- Any other use other than that permitted is
operation is successful an “y” is displayed, mum temperature alarm refers to the de facto prohibited. It should be noted
Alarm ON when the alarm is enabled; blinking when the alarm is silenced
on the contrary, if it fails a “n” will be dis- thermostat probe. The temperature limits that the relay contacts provided are of a
played. are defined by the parameters “HAL” practical type and therefore subject to
Fans ON when the fan is working (maximum alarm) and “LAL” (minimum fault. Any protection devices required by
alarm). product standards or dictated by common
sense due to obvious safety reasons should
be applied externally.
ID 974 2/7
TECHNICAL DATA • (C) third contact SPST 11A 250Va. MACHINE STATUS MENU DIAGRAM AND PROGRAMMING MENU DIAGRAM
Consumption: 3W max.
ALL MODELS
Power supply: 95...240Vc ±10%
Frontal panel protection: IP65.
Casing: plastic body in resin type
Warning: check the power supply specified
PC+ABS UL94 V-0, inspection window in
on the instrument label; for relay and
polycarbonate, buttons in thermoplastic
power supply capacities, contact the Sales press and release set AL set alarms if alarm(s)
resin. (single press) present
Office).
Dimensions: frontal panel 74x32 mm, show alarms
depth 60 mm (depth 68 mm only for ID
974 switching).
Installation: on panel, with drilling tem-
plate 71x29 mm (+0.2/–0.1 mm).
Use temperature: –5…55 °C.
Storage temperature.: –30…85 °C. SEt set SEt value
Use and storage environment humidity:
10…90 % RH (not condensing). change SEt
Viewing range: value
• NTC probe: –50…110 °C (-58...230°F)
• PTC probe: –55…140 °C (-67...284°F) Pb1 set Pb1 value
without decimal point (selectable through
parameter on 3 digit + 1/2 mark display.
Analog inputs: two PTC or NTC inputs Machine Status Menu Diagram
(programmable by parameter).
Serial: TTL for connection to Copy Card or
Pb2 set Pb2 value
Televis system. PLEASE NOTE: The technical data
Digital outputs: 3 relay contacts: first con- included in this document, related to
measurement (range, accuracy, resolu-
tact SPDT 8(3)A 250VA, second contact
tion, etc.) refer to the instrument
SPST 8(3)A 250VA, third contact SPST 5(2)
itself, and not to its equipment such as,
A 250VA. press for 5 sec set PA1&0 set
for example, sensors.
Measuring range: from –55 to 140 °C.
This means, for example, that sensor(s)
Accuracy: 0.5% better than end scale + 1 set PA1 value
error(s) shall be added to the instru-
digit.
ment’s one.
Resolution: 1 or 0.1 °C.
Consumption
• model 230V: 3 VA max.
• model 12V: 1,5 VA max.
• model with switching Power Supply: 3W
LIABILITY AND RESIDUAL RISKS
Power supply: 12 Va/c ±10% or 230Va
Eliwell Controls s.r.l. shall not be liable for any damages deriving from:
±10% 50/60 Hz.
- installation/use other than that prescribed and, in particular, that which does not
comply with safety standards anticipated by regulations and/or those given herein; CP set level 1 par
MODEL 8+8+15A - use on boards which do not guarantee adequate protection against electric shock,
Digital outputs: 3 relay contacts: water or dust under the conditions of assembly applied;
- use on boards which allow access to dangerous parts without the use of tools;
• (A) SPDT 8(3)A (1/2 Hp) 250VA,
- tampering with and/or alteration of the products; dEF set level 1 par
• (B) SPST 8(3)A (1/2 Hp) 250VA,
- installation/use on boards that do not comply with the standards and regulations in
• (C) SPST 15A (1 Hp) 250VA.
Consumption: 1,5 VA max. force.
Power supply: 12 Va/c ±10%.
DISCLAIMER
MODEL 8+8+15A + D.I. FAn set level 1 par
Digital input This manual and its contents remain the sole property of Eliwell Controls s.r.l., and
1 voltage-free digital input that can be set shall not be reproduced or distributed without authorization. Although great care has scroll
by parameter. been exercised in the preparation of this document, Eliwell Controls s.r.l., its employ- parameters
MODEL with Switching power supply ees or its vendors, cannot accept any liability whatsoever connected with its use.
Eliwell Controls s.r.l. reserves the right to make any changes or improvements with-
AL set level 1 par
Digital outputs: 3 relay contacts:
out prior notice. change
• (A) first contact SPDT 8A 250Va, par value
• (B) second contact SPST 3A 250Va,
LAL Lower ALarm. Minimum temperature alarm. Temperature value (with regard to Setpoint), -50.0...HAL -50.0 1 °C/°F
which if exceeded in a downward direction, triggers the activation of the alarm signal.
PAO Power-on Alarm Override. Alarm exclusion time after instrument switch on, 0...10 0 1 hours
after a power failure.
dAO defrost Alarm Override. Alarm exclusion time after defrost. 0..999 0 1 min
tAO temperature Alarm Override. Temperature alarm signal delay time. 0...250 0 1 min
DISPLAY (folder with “diS” label)
LOC (keyboard) LOCk. Keyboard locking. However, you can enter parameter programming n/y n 1 flag
modify them along with the status of this parameter in order to allow keyboard locking.
y = yes; n = no
PA1 PAssword 1. When enabled (value other than 0) it constitutes the access key for 0...250 0 1 num
level 1 parameters.
ndt number display type. View with decimal point. y = yes; n = no n/y y 1 flag
CA1 CAlibration 1.Calibration 1. Positive or negative temperature value added to the value -12.0...12.0 0 1 °C/°F
read by probe 1.
CA2 CAlibration 2.Calibration 2. Positive or negative temperature value added to the value -12.0...12.0 0 1 °C/°F
read by probe 2.
ddL defrost display Lock. Viewing mode during defrosting. 0/1/2 1 1 flag
0 = shows the temperature read by the thermostat probe;
1 = locks the reading on the temperature value read by thermostat probe when
defrosting starts, and until the next time the Setpoint value is reached;
2 = displays the label “deF” during defrosting, and until the next time the
Setpoint value is reached.
dro display read-out. Select °C or °F for displaying the temperature read by the thermostat 0/1 0 1 flag
probe. 0 = °C, 1 = °F. PLEASE NOTE: the switch between °C and °F DO NOT modify
setpoint, differential, etc. (for example set=10°C become 10°F).
ID 974 - 12 V ID 974 - 12 V
(A) (B) (C) (A) (B) (C)
Supply A A
Supply
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11
Pb1
Pb2
Pb1
Pb2
TERMINALS
1 Common relay contact (15 A max)
2 N.O. Defrost relay (A)
3 N.C. Defrost relay (A)
ID 974 - 230 V
4 N.O. Fan relay output (B)
(A) (B) (C) 5 N.O. Compressor relay output (C)
6-7 Power supply (1,5 VA max)
Supply A
8-9 Probe 2 input (evaporator)
8 - 10 Probe 1 input (thermostat)
1 2 3 4 5 6 7 8 9 10 A TTL input for Copy Card
Pb2 Pb1
N
L
TERMINALS
3- 4 N.O. Defrost relay (A)
3- 5 N.C. Defrost relay (A)
2- 6 N.O. Fan relay output (B)
2- 7 N.O. Compressor relay output (C)
8- 9 Probe 2 input (evaporator)
8- 10 Probe 1 input (thermostat)
1- 2 Power Supply- 95...240Vc (3W)
ELIWELL CONTROLS s.r.l. A TTL input for Copy Card
Via dell'Industria, 15 Zona Industriale Paludi
NOTE: Default user settings
32010 Pieve d'Alpago (BL) ITALY
Telephone +39 0437 986111
Facsimile +39 0437 989066
Internet http://www.eliwell.it
7/2006 -GB-
cod. 9IS42066