Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

A B C D E F G H J K L M N

8300cm
15 855 860 860 860 860 860 860 860 428 410 420 155
EXISTING COMPOUND WALL ‫قطاع الشؤون الهندسية‬
Engineering Affairs Sector
‫إدارة المباني‬
Building Department
08

155
P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 07 CONSULTANT
30 30 30 30 30 30 30 30 30
30

60
60

60

60

60

60

60

60

60

60
P1-0987
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

402
P1 06 AL NAKHEEL

P1-0987
30

60
AL NAKHEEL
DESIGN
CONSULTANT
SUPERVISION ENGINEERING CONSULTANTS
P.O Box : 2476, Tel. : 7457929, Fax : 7429305, Al Nakheel Street

413
Opp. Masjid Al Furkan, Ajman, United Arab Emirates

NOTES
30 30 30 30 30 30 30 30 30

P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 05
60

60

60

60

60

60

60

60

60

P2-0987
60
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

45

EXISTING COMPOUND WALL

412
P1 P1 04

P1-0987

P1-0987
30

30
60 60

3485cm
700
P1 P1 03
P1-0987

P1-0987
30

30
60 60

702
P1 P1 02
P1-0987

P1-0987
30

30
60 60

687
15 01
P1-0987

P1-0987
30

30

60 60

P1 P1

COLUMN LAYOUT
SCALE :- 1:150

OWNER:
AJI JACOB PARAMPUZHAYIL
ANTONY JAMES
SCHEDULE OF PEDESTAL
TYPE DETAIL PROJECT DESCRIPTION :
REMARKS

PROPOSED OPEN SHED

P1 DRAWING TITILE :


12 Y16
Y 8 @ 15 C/C

COLUMN LAYOUT


P2 14 Y16 PLOT NO. ARCH. ENG.




Y 8 @ 15 C/C
0043 Susan

SECTOR STRUC. ENG.


NORTERN Sherly

DISTRICT M.E.P. ENG.


JURF IND.1 Das

JOB. NO. DRAWN BY :


Anec 15/Shed/DEPT-0043 Viju

SCALE CHECKED BY :
1 : 150 DIPIN
SHEET NO. DATE :
ST - 01 13/03/2023
A B C D E F G H J K L M N
8300cm
15 855 860 860 860 860 860 860 860 428 410 420 155
EXISTING COMPOUND WALL ‫قطاع الشؤون الهندسية‬
Engineering Affairs Sector
‫إدارة المباني‬
ROOF 85 Building Department
TBM 30 ROOF 91 ROOF 91 ROOF 91 ROOF 91 ROOF 91 ROOF 91 ROOF 91 ROOF 91 ROOF 100 08

155
TL 115 TL 91 TL 91 TL 91 TL 91 TL 91 TL 91 TL 91 TL 91 TL 100
P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 07 CONSULTANT
30 30 30 30 30 30 30 30 30
30

60
60

60

60

60

60

60

60

60

60
P1-0987
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

402
ROOF 100
TL 100
P1 06 AL NAKHEEL

P1-0987
30

60
AL NAKHEEL
DESIGN
CONSULTANT
SUPERVISION ENGINEERING CONSULTANTS
P.O Box : 2476, Tel. : 7457929, Fax : 7429305, Al Nakheel Street

413
ROOF 85 61 Opp. Masjid Al Furkan, Ajman, United Arab Emirates
ROOF 61 ROOF61 ROOF ROOF61 ROOF 61 ROOF61 ROOF61 ROOF61 ROOF 142
TBM 38 TBM 40 TBM 40 TBM 40 TBM 40 TBM 40 TBM 40 TBM 40 TBM 40 TBM 16
TL 123 TL 101 TL 101 TL 101 TL 101 TL 101 TL 101 TL 101 TL 101 TL 158
NOTES
30 30 30 30 30 30 30 30 30

P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 05
60

60

60

60

60

60

60

60

60

P2-0987
60
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

45

EXISTING COMPOUND WALL

412
P1 P1 04

P1-0987

P1-0987
30

30
60 60

ROOF 51 ROOF 77
TBM 35 TL 77
TL 86

3485cm
700
ROOF 51
TBM 35 ROOF 77
TL 86 TL 77
P1 P1 03
P1-0987

P1-0987
30

30
60 60

702
ROOF 51
TBM 35 ROOF 77
TL 86 TL 77
P1 P1 02
P1-0987

P1-0987
30

30
60 60

P1 P1 687
15 01
P1-0987

P1-0987
30

30

60 60

ROOF 28 ROOF 42
TBM 35 TBM 30
TL 63 TL 72

COLUMN LAYOUT
SCALE :- 1:150

OWNER:
AJI JACOB PARAMPUZHAYIL
ANTONY JAMES
SCHEDULE OF PEDESTAL
TYPE DETAIL PROJECT DESCRIPTION :
REMARKS

PROPOSED OPEN SHED

P1 DRAWING TITILE :


12 Y16
Y 8 @ 15 C/C



P2 14 Y16 PLOT NO. ARCH. ENG.




Y 8 @ 15 C/C
0043 Susan

SECTOR STRUC. ENG.


NORTERN Sherly

DISTRICT M.E.P. ENG.


JURF IND.1 Das

JOB. NO. DRAWN BY :


Anec 15/Shed/DEPT-0043 Viju

SCALE CHECKED BY :
DIPIN
SHEET NO. DATE :
13/03/2023
A B C D E F G H J K L M N
8300cm
15 855 860 860 860 860 860 860 860 428 410 420 155
EXISTING COMPOUND WALL ‫قطاع الشؤون الهندسية‬
Engineering Affairs Sector
‫إدارة المباني‬
Building Department
08

155
F2 F2 F2 F2 F2 F2 F2 F2 F2 F2
07 CONSULTANT
30 30 30

P1
30 30 30 30 30 30

P1
30

P1 P1 P1 P1 P1 P1 P1

60
60

60

60

60

60

60

60

60

60
P1
P1-0987
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

402
F2
06 AL NAKHEEL

P1-0987
30

60
AL NAKHEEL
DESIGN

P1
CONSULTANT
SUPERVISION ENGINEERING CONSULTANTS
P.O Box : 2476, Tel. : 7457929, Fax : 7429305, Al Nakheel Street

413
Opp. Masjid Al Furkan, Ajman, United Arab Emirates

F1 F1 F1 F1 F1 F1 F1 F1 F1 F3
P1 P1 P1 P1 P1 P1 NOTES
30 30 30 30 30 30 30 30 30

05
60

60

60

60

60

60

60

60

60

P2-0987
60
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

45

P1 P1 P1 P2

EXISTING COMPOUND WALL

412
F1 F2
04

P1-0987

P1-0987
P1

30

30
60 60

P1

3485cm
700
F1 F2
P1 03
P1-0987

P1-0987
30

30
60 60

P1

702
F1 F2
P1 02
P1-0987

P1-0987
30

30
60 60

P1

687
P1 P1
15 01
P1-0987

P1-0987
30

30

F1
60 60

F2

FOUNDATION LAYOUT
SCALE :- 1:200

NOTES FCU=40N/mm²
Fy=460N/mm² GRADE SLAB WILL BE 20cm.THK.
1 * INDICATED FOUNDATION @ LOW LEVEL WITH BRC A-193 DOUBLE MESH STEEL COLUMN by others
OWNER:
HAIR PIN BASE PLATE
AS PER SCHEDULE. AJI JACOB PARAMPUZHAYIL
PLINTH LEVEL
AS/PLAN

ANTONY JAMES
VARIED

SCHEDULE OF FOOTING PAVED ROAD LEVEL. BOLT AS PER SCHEDULE


12 PROJECT DESCRIPTION :
REMRK.

BOTTOM REINFORCEMENT
TYPE SIZE IN CM
SHORT STEEL LONG STEEL PROPOSED OPEN SHED
20 CM THICK WELL COMPACTED. 12 PEDESTAL AS/PER SHEDULE
Y 16 @ 20CM C/C Y 16 @ 20CM C/C
ROAD BASE.
F1 160 x 230 x 45
FOOTING AS PER SHEDULE DRAWING TITILE :
F2 150 x 220 x 45 Y 16 @ 20CM C/C Y 16 @ 20CM C/C
175

F3 170 x 250 x 45 Y 16 @ 20CM C/C Y 16 @ 20CM C/C


200

10

PCC PLOT NO. ARCH. ENG.


10

0043 Susan
well compacted sub grade
25

(to at least 96% of m.d.d )


SECTOR STRUC. ENG.
TYP. DET. OF SUB STRUCTURE NORTERN Sherly

DISTRICT M.E.P. ENG.


JURF IND.1 Das

JOB. NO. DRAWN BY :


Anec 15/Shed/DEPT-0043 Viju

SCALE CHECKED BY :
DIPIN
SHEET NO. DATE :
13/03/2023
A B C D E F G H J K L M N
8300cm
15 855 860 860 860 860 860 860 860 428 410 420 155
EXISTING COMPOUND WALL ‫قطاع الشؤون الهندسية‬
Engineering Affairs Sector
‫إدارة المباني‬
Building Department
08

155
CTB

07 CONSULTANT
30 30 30 30 30 30 30 30 30
30

60
60

60

60

60

60

60

60

60

60
P1-0987
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

402
TB1

06 AL NAKHEEL

P1-0987
30

60
AL NAKHEEL
DESIGN
CONSULTANT
SUPERVISION ENGINEERING CONSULTANTS
P.O Box : 2476, Tel. : 7457929, Fax : 7429305, Al Nakheel Street

413
Opp. Masjid Al Furkan, Ajman, United Arab Emirates

NOTES
30 30 30 30 30 30 30 30 30

05
60

60

60

60

60

60

60

60

60

P2-0987
60
P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987 P1-0987

TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1 TB1


45

EXISTING COMPOUND WALL

412
TB1
04

P1-0987

P1-0987
30

30
60 60

3485cm
TB1

700
03
P1-0987

P1-0987
30

30
60 60
TB1

702
02
P1-0987

P1-0987
30

30
60 60

687
TB1

15 01
P1-0987

P1-0987
30

30

60 60

TB1 CTB

TIE BEAM LAYOUT 20cm thick


SCALE :- 1:200 hollow block wall
4 T 12
NOTES FCU=40N/mm²
F. F. L (TOC)
Fy=460N/mm² 15cm.THK.
1 ALL TIE BEAM @ +0.30 LVL BRC A-193 MESH OWNER:
2 - 20cm SOLID BLOCK MASONRY.
AS/PLAN

AJI JACOB PARAMPUZHAYIL


ANTONY JAMES
AS/DRAWING

1000 guage
polythene sheet coping beam (20x20)
PROJECT DESCRIPTION :
WELL COMPACTED IMPORTED SOIL

PROPOSED OPEN SHED


GATE LVL.
00
20cm thick solid
20 block wall
SCHEDULE OF TIE BEAM DRAWING TITILE :
VARIED

PAVED ROAD
REINFORCEMENT
BOTTOM TOP FACE
REMARKS

SIZE IN
polythene sheet

BARS
1000 guage

TYPE 2 coats of
CM OVER @ (EACH STIRRUPS 10 10 10
16 mm. Ø HAIRPIN
CONTINUS CONTINUS hot bittumin PLOT NO. ARCH. ENG.
SUPPORT SIDE ) Susan
0043
175

T 12 @ 20CM C/C
15

TB1 20 x 60 3 Y 16 2 Y 16 1 Y 16 ---- Y 8 @ 15 CM C/C SECTOR STRUC. ENG.


5 T 12 NORTERN Sherly
CTB 20 x 60 3 Y 16 5 Y 16 ---- ---- Y 8 @ 15 CM C/C
10 15

DISTRICT M.E.P. ENG.


10

10CM THICK P C C Das


JURF IND.1
HAIR PIN JOB. NO. DRAWN BY :
25

Anec 15/Shed/DEPT-0043 Viju

SCALE CHECKED BY :
DIPIN
25 cm thick well compacted well compacted sub grade
SHEET NO. DATE :
road base layer. 13/03/2023
(to at least 96% of m.d.d )
A B C D E F G H J K L M N
8300cm
15 855 860 860 860 860 860 860 860 428 410 420 155
‫قطاع الشؤون الهندسية‬
Engineering Affairs Sector
‫إدارة المباني‬
Building Department
08

155
07 CONSULTANT
ST1 ST2 ST2 ST2 ST2 ST2 ST2 ST2 ST2 ST2
BP1 BP2 BP2 BP2 BP2 BP2 BP2 BP2 BP2 BP2

402
06 AL NAKHEEL
ST2 AL NAKHEEL
DESIGN
CONSULTANT
SUPERVISION ENGINEERING CONSULTANTS
BP2 P.O Box : 2476, Tel. : 7457929, Fax : 7429305, Al Nakheel Street

413
Opp. Masjid Al Furkan, Ajman, United Arab Emirates

BP3
ST3 NOTES
05
ST1 ST2 ST2 ST2 ST2 ST2 ST2 ST2 ST2 ST3
BP1 BP2 BP2 BP2 BP2 BP2 BP2 BP2 BP2 BP3

412
04
ST2 ST2
BP2 BP2

3485cm
700
03
ST2 ST2
BP2 BP2

702
02
ST2 ST2
BP2 BP2

687
15 01
ST1 ST1
BP1 BP1

STEEL COLUMN AND BASE PLATE LAYOUT


SCALE :- 1:200

NOTES
FCU=40N/mm²
1 * INDICATING STEEL COLUMNS UP TO MEZZANINE LEVEL ONLY Fy=460N/mm² OWNER:
SCHEDULE OF BASE PLATE SCHEDULE OF STEEL COLUMN AJI JACOB PARAMPUZHAYIL
ANTONY JAMES
NAME SIZE NAME SIZE
PROJECT DESCRIPTION :
BP1 = 450 x 200 x 20 mm ( 2 x 3-Nos. - M20 ANCHOR BOLT 500mm LENGTH ) ST1 UB = 406 x 140 x 46 kg/m PROPOSED OPEN SHED

BP2 = 500 x 200 x 20 mm ( 2 x 3Nos. - M20 ANCHOR BOLT 500mm LENGTH ) ST2 UC = 452 x 152 x 60 kg/m DRAWING TITILE :

BP3 = 300 x 300 x 20 mm ( 2 x 2Nos. - M20 ANCHOR BOLT 500mm LENGTH ) ST3 UC = 254 x 254 x 73 kg/m

PLOT NO. ARCH. ENG.


0043 Susan

SECTOR STRUC. ENG.


NORTERN Sherly

DISTRICT M.E.P. ENG.


JURF IND.1 Das

JOB. NO. DRAWN BY :


Anec 15/Shed/DEPT-0043 Viju

SCALE CHECKED BY :
DIPIN
SHEET NO. DATE :
13/03/2023
A B C D E F G H J K L M N
8300cm
15 855 860 860 860 860 860 860 860 428 410 420 155
‫قطاع الشؤون الهندسية‬
Engineering Affairs Sector
 
‫إدارة المباني‬
Building Department
08
RB2

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

155
RB
RU RU 07 CONSULTANT
RU RU RU

402
1
RB
06 AL NAKHEEL
RB2

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

1
RB
AL NAKHEEL
DESIGN
CONSULTANT
SUPERVISION ENGINEERING CONSULTANTS
1
RB
P.O Box : 2476, Tel. : 7457929, Fax : 7429305, Al Nakheel Street

413
Opp. Masjid Al Furkan, Ajman, United Arab Emirates

NOTES

RU
05
RU RU RU RU RU RU

412
RU

 RB1 RB1
04
 


3485cm
700
RB1 RB1
RU 03

702
RU
RB1 RB1
02
RU

687
RU

RB2 RB2
15 01

ROOF LAYOUT
SCALE :- 1:200
SCHEDULE OF ROOF STEEL BEAM
FCU=40N/mm² NAME SIZE OWNER:
Fy=460N/mm²
RB1 UB 457 x 152 x 52 kg/m. AJI JACOB PARAMPUZHAYIL
ANTONY JAMES
RB2 UB 356 x 127 x 39 kg/m.

RU UB 254 x 102 x 25 kg/m. PROJECT DESCRIPTION :


PROPOSED OPEN SHED

DRAWING TITILE :

SLEEVE
12MM THK. STIFFNER PLATE MINIMUM 5CM LENGTH HOLES
12MM THK. STIFFNER PLATE 'Z' PURLIN TO ALLOW FOR EXPANSION MOVEMENT 32(typ) 32(typ)
SLEEVE PURLINS /
32(typ)
PURLINS / SIDE RAILS
SIDE RAILS PLOT NO. ARCH. ENG.
0043 Susan
RB1 RB1
SECTOR STRUC. ENG.
NORTERN Sherly
2X2 NOS M 20 Ø BOLT 16 MM THICK PLATE CUT FROM 'RB1'
DISTRICT M.E.P. ENG.
2X6 NOS. M20 Ø BOLT (GR. 8.8)
JURF IND.1 Das
PURLIN BRACE
20MM END PLATE STEEL PLATE. 50 X 50 X 5 MM THICK ANGLE STEEL PLATE.
12 MM O BOLTS GRADE 4.60 PURLIN BRACE JOB. NO. DRAWN BY :
50 X 50 X 5 MM THICK ANGLE
USE 10MM FILLET WELD FOR 16MM THK. STIFFNER PLATE Anec 15/Shed/DEPT-0043 Viju
STEEL BEAM AS/SCHE. 12 MM O BOLTS GRADE 4.60
COLUMN & WEB FLANGES STEEL BEAM AS/SCHE.
STEEL COL. AS/SCHED. STEEL COL. AS/SCHED. SCALE CHECKED BY :
DETAIL OF PURLIN AT EXPANSION JOINT DETAIL OF PURLIN BRACING DIPIN
 SHEET NO. DATE :

13/03/2023
‫قطاع الشؤون الهندسية‬
Engineering Affairs Sector
‫إدارة المباني‬
STRUCTURAL STEEL NOTES: STRUCTURAL STEEL NOTES: Building Department

CONSULTANT

1. THE CONTRACTOR IS RESPONSIBLE FOR THE FINAL


1. ALL DIMENSIONS ARE IN MILLIMETERS (CM) (U.N.O)
DESIGN PERFORMANCE OF ALL STRUCTURAL STEEL FRAMING. ALL
2. REACTIONS FORCE ARE IN KILO-NEWTON (KN) AND MOMENTS IN
SIZE AND DESIGN REQUIREMENTS SHOWN ON THE DRAWINGS ARE AL NAKHEEL
AL NAKHEEL
DESIGN

KILO-NEWTON METER (KNM) UNITS. ENGINEERING CONSULTANTS


CONSULTANT
SUPERVISION

P.O Box : 2476, Tel. : 7457929, Fax : 7429305, Al Nakheel Street


TO BE CONSIDERED MINIMUM REQUIREMENTS AND NOT FINAL Opp. Masjid Al Furkan, Ajman, United Arab Emirates

3. BRACING REACTIONS SHOULD BE ADDED TO THE MAIN FRAME FRAME


REACTIONS.. REQUIREMENTS. PRIOR TO FABRICATION OF FRAMING NOTES
2. ALL STRUCTURAL STEEL MEMBERS ARE DESIGNED IN ACCORDANCE
4. FOUNDATIONS SHALL BE DESIGNED FOR THE GIVEN REACTIONS AS A
WITH BS LOAD AND RESISTANCE FACTOR DESIGN THIRD EDITION.
MINIMUM.
5. ANCHOR BOLT MUST BE SET STRAIGHT AND TO THE GIVEN DIMENSIONS 3. STEEL STRUCTURE IS NOT STABLE UNTIL ALL MEMBERS,
AND THE PROJECTIONS WITH A MAXIMUM OF 5 MM TOLERANCES. BRACINGS, MOMENT FRAMES, FLOOR AND ROOF METAL DECKS,
6. ANCHOR BOLT THREADS MUST BE PROTECTED WHILE POURING THE ETC. ARE INSTALLED.
CONCRETE AND MUST BE THOROUGHLY CLEANED, AND THE TEMPLATES
4. SUPPLY AND REMOVE TEMPORARY BRACING AS REQUIRED DURING
ARE TO BE REMOVED AFTER POURING CONCRETE.
CONSTRUCTION. CONTRACTOR IS SOLE RESPONSIBLE FOR MEANS

7. THE CONCRETE EDGE BEAM / SLAB MUST BE SQUARE AND LEVEL TO AND METHODS OF CONSTRUCTION.

WITHIN 5 MM TOLERANCES.
5. PLATES, FLATS AND ROLLED SECTIONS SHALL BE BS STANDARD
8. THE CUSTOMER / CONTRACTOR IS RESPONSIBLE FOR LOCATING THE GRADE S275 (FY=275MPa). STRUCTURAL STEEL SHALL BE IN FULL
BUILDING LINES AND BENCH MARKS AT THE SITE. COMPLIANCE WITH NATIONAL STRUCTURAL STEELWORK
SPECIFICATION FOR BUILDING CONSTRUCTION.
9. THE FOLLOWING ARE THE MAXIMUM ALLOWABLE TOLERANCES FOR
SETTING UP THE ANCHOR BOLTS. 6. BOLTS SHALL BE GRADE 8.8 AND 16mm DIAMETER MINIMUM.
9.1. ± 2 MM BETWEEN ANY TWO ANCHOR BOLTS IN ANY ANCHOR BOLT PROVIDE MINIMUM (2) TWO BOLTS PER CONNECTION.
GROUP.
7. STRUCTURAL STEEL CONNECTIONS SHALL BE DESIGNED BY THE
9.2. ± 3 MM BETWEEN ANY TWO ADJACENT ANCHOR BOLT GROUPS.
STEELWORK CONTRACTOR. SIGNED AND SEALED ENGINEERING
9.3. ± 5 MM FOR THE TOP OF ANCHOR BOLTS.
CALCULATIONS, BY LICENSED PROFESSIONAL ENGINEER, SHALL BE
10. ALL THE ANCHOR BOLTS MUST BE SET PERPENDICULAR TO THE SUBMITTED TO THE CONSULTANT FOR REVIEW.
THEORETICAL BEARING SURFACE UNLESS NOTED OTHERWISE.
8. WELDING STANDARD IS AWS D1.1/D1.1M 2006, STRUCTURAL
11. ANCHOR BOLTS SHALL BE SET BY THE OWNER (OR HIS CIVIL CONTRACTOR)
IN ACCORDANCE WITH THE "ISSUED FOR CONSTRUCTION" ANCHOR BOLT STEEL WELDING CODE. ALL WELDING ELECTRODES SHALL HAVE A
SETTING PLAN. YIELD STRESS AND A TENSILE STRESS NOT LESS THAN THOSE

12. WHEN REQUIRED FOR DESIGN, ASSUMES THE SPECIFIED FOR THE GRADE OF STEEL BEING WELDED.
2
COMPRESSIVE STRENGTH OF CONCRETE FC' = 35 N/MM
9. ALL FILLET WELDS SHALL HAVE A MINIMUM 6MM LEG AND ALL
13. OUR CONSULTANTS SHALL NOT BE RESPONSIBLE FOR BUTT WELDS SHALL BE FULL PENETRATION TYPICAL. TESING OF
ANY CONSEQUENCES ARISING FROM CASTING THE ANCHOR BOLTS
WELDS SHALL BE AS PER THE SPECIFICATIONS. OWNER:
ON THE BASIS OF THE "APPROVAL DRAWINGS".
AJI JACOB PARAMPUZHAYIL
14. THE STEEL STRUCTURE, OR PARTS OF IT, IS DESIGNED TO BE 10. ALL STRUCTURAL STEEL SHALL BE CORROSION PROTECTED IN ANTONY JAMES

STRUCTURALLY DEPENDENT ON THE CONCRETE STRUCTURAL WORK. IT ACCORDANCE WITH THE DRAWINGS AND THE SPECIFICATIONS.
IS THE CUSTOMER'S RESPONSIBILITY TO VERIFY THE ADEQUACY OF PROJECT DESCRIPTION :
THE CONCRETE FOR STRUCTURAL SOUNDNESS AND STRENGTH. 11. STEEL MEMBERS SHALL GENERALLY BE ONE PIECE. ALL MEMBER PROPOSED OPEN SHED

SPLICES SHALL BE FULL-PENETRATION WELDS. APPROVAL MUST


15. STRUCTURAL STEEL FIRE PROOFING SYSTEM SHALL BE DRAWING TITILE :
BE OBTAINED FROM THE CONSULTANT BEFORE ANY SPLICES MAY
SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) OR INTUMESCENT
BE USED. ALL SPLICES MUST BE CLEARLY INDICATED ON THE
COATING. MINIMUM 2 HOURS FIRE RESISTANCE.
SHOP DRAWINGS.
PLOT NO. ARCH. ENG.
0043 Susan

SECTOR STRUC. ENG.


NORTERN Sherly

DISTRICT M.E.P. ENG.


JURF IND.1 Das

JOB. NO. DRAWN BY :


Anec 15/Shed/DEPT-0043 Viju

SCALE CHECKED BY :
DIPIN
SHEET NO. DATE :
13/03/2023

You might also like