How many potable water service and drain panels are fitted on the aircraft?
A - One.
B - Two.
C - Three.
How many potable water service and drain panels are fitted on the aircraft?
A - One.
B - Two.
C - Three.
Where is the fill and drain valve port located?
A - On the potable water service panel.
B - On the forward water drain panel.
C - On both.
How many potable water service and drain panels are fitted on the aircraft?
A - One.
B - Two.
C - Three.
Why are drain valves installed in the waste water drain system?
A - To allow the sinks and wash basins to be isolated.
B - To prevent a permanent loss of cabin air pressurization.
C - To prevent wash basins from being isolated.
The water valve and the flush valve are monitored by:
A - The Vacuum System Controller.
B - The vacuum generator.
C - The associated Flush Control Unit BITE.
449. Why are the drain valve installed in the waste water drain system?
(B1,B2)
A. To allow the sink and wash basin to be isolated
B. To prevent a permanent loss of cabin air pressurization
C. To prevent wash basin from being isolated
451. From where does the LAV INOP Fault light come at the FWD Attendant
Panel? (B1,B2)
A. A level sensor in each toilet unit
B. A fault of the related lavatory flush control unit (FCU)
C. A fault of the VACUUM GENERATOR
D. The door limit switch (panel door open) on the servicing panel.
452. Is it possible to drain the whole water system without electrical power?
(A,B1,B2)
A. No, electrical power is always required
B. Yes, all the drain valves can be operated manually
454. What is used for A320 aircraft water tank filling operation? (A,B1,B2)
A. One handle, one valve.
B. Two handles, one valve.
C. One handle, two valves.
455. How many valves are used during draining operation of A320 aircraft
water tank
(A,B1,B2)
A. Two
B. Three
C. Four
456. How many potable water service and drain panels are fitted to the A320
aircraft?
(A,B1,B2)
A. One
B. Two
C. Three
458. How many potable water quantity indicators are there? (A,B1,B2)
A. One
B. Two
C. Three
460. What is purpose of the high level switch of the water quantity
TRANSMITTER? (B1,B2)
A. De-energized a relay which closes the fill/drain valve when the tank is full.
B. To disconnect electrical supply to the water heater in the lavatories
C. To disconnect electrical supply to the fill/drain valve to closes it when the
tank is full.
D. To gives warming of water tank overfill.
461. What is purpose of the water service panel door microswitch? (B1,B2)
A. To de-energized the indicating system when the portable water service
panel door is opened.
B. To energized the indicating system when the portable water service panel
door is closed.
C. To isolate the indicating system when the portable water service panel
door is closed.
D. To isolate the indicating system when the portable water service panel
door is opened.
463. Where does the toilet bowl rinsing water come from? (A,B1,B2)
A. Waste holding tank.
B. Waste water tank.
C. Potable water tank
466. How many toilet service panels are fitted on the aircraft? (A,B1,B2)
A. One
B. Two
C. Three
467. How many potable water service and drain panels are fitted to the
aircraft? (A,B1,B2)
A. One
B. Two
C. Three