Professional Documents
Culture Documents
Solution.: Prepared by Reveiwed by Verified by Approved by Q.C Analyst Deputy QCM QCM QAM / Plant Manager
Solution.: Prepared by Reveiwed by Verified by Approved by Q.C Analyst Deputy QCM QCM QAM / Plant Manager
Solution.: Prepared by Reveiwed by Verified by Approved by Q.C Analyst Deputy QCM QCM QAM / Plant Manager
CORE TABLETS:
1. Physical Appearance:
White color, oblong shaped core tablets, one side is scored with bisects line and other side is plain
2. Identification:
Retention time of sample peak corresponds to the Retention time of standard peak.
3. Average Weight:
Weigh 20 Tablets individually and calculate Average weight mg/Tab.
4. Disintegration Time:
Take 6 tablets for disintegration test. After attaining the required temperature put the sample tablets, one
in each of six tubes of basket assembly and place discs in each tube. Start the apparatus.
Note down the time when no residue remains on the wire mesh. The disintegration time is considered as
the time when the last tablet has disintegrated.
5. Hardness:
Take NLT 10 tablets for recording hardness of Tablets, Calculate average of readings in kg/f.
6. Friability:
Weigh 20 tablets sample and put in Friability chamber and start rotating after completion of rotating
weigh sample and observe that the sample is free from cracked, cleaved or broking. Calculate the %
friability using formula:
Standard solution:
0.008 mg/mL of Vildagliptin and 0.08mg/ml Metformin HCl prepared as follows. Accurately weighed
10mgVildagliptin working standard and 100mg of Metformin HCl working standard to a 100ml
volumetric flask, add Mobile phase to about 60% of the final volume and sonicate for about 5 min to
dissolve. Make up the volume with mobile phase.
Pipette 2ml from the stock solution in 25ml volumetric flask. Pass through a suitable filter of 0.45- µm
pore size.
Sample solution:
0.008 mg/mL of Vildagliptin and 0.08mg/ml Metformin HCl prepared as follows. Crush the 10
tablets.Accurately weighed 140mg powder weight(equivalent to 10mg Vildagliptin and 100mg
Metformin HCl) powder to a 100ml volumetric flask. Add Mobile Phase to about 60% of the final
volume, shake mechanically for about 60 min, and make up the volume with mobile phase.
Pipette 2ml from the stock solution in 25ml volumetric flask. Pass through a suitable filter of 0.45- µm
pore size.
% Results:
Calculate the percentage of Metformin Hydrochloride(C4H11N5,HCl).in the portion of Tablets taken:
Result = (rU/rS) × 100
rU= peak response of metformin hydrochloridefrom the Sample solution
rS= peak response of metformin hydrochloride from the Standard solution.
COATED TABLETS:
1. Physical Appearance:
Blue color oblong, biconvex film coated tablets, one sides is scored with bisect line and other side is
plain.
2. Average Weight:
Weigh 20 Tablets and calculate Average weight mg/Tab.
3. Disintegration Time:
PREPARED BY REVEIWED BY VERIFIED BY APPROVED BY
Q.C Analyst Deputy QCM QCM QAM / Plant Manager
Take 6 tablets for disintegration test (one in each basket) after attaining the required temperature, put the
sample tablets, one in each of six tubes of basket assembly and place discs in each tube. Start the
apparatus.
Note down the time when no residue remains on the wire mesh. The disintegration time is considered as
the time when the last tablet has disintegrated.
Medium temperature should be 37± 1°C.
4. Assay:
NLT 90.0% and NMT 110.0% of the labeled amount of Metformin HCl And Vildagliptin.
Mobile phase:
Acetonitrile: Phosphate Buffer: Water (65:20:15)
Buffer
6.75 g/L of Potassium Dihydrogen Phosphate in water. Adjust with1 M Sodium Hydroxide to a pH of
6.0(±0.01).
Diluent:
Mobile Phase.
Chromatographic Conditions:
Mode : LC
Detector : UV 239nm for Metformin HCl, UV 213nm for Vildagliptin
Analytical Column : 4.6mm x 25-cm, 5µm packing L1(C18)
Temperature : 25 °C
Flow rate : 1ml / min
Inject Volume : 10µL
System suitability
Tailing factor:
NMT 2.0 System suitability solution
Relative standard deviation:
NMT 2.0% Standard solution
Analysis:
Standard solution:
0.008 mg/mL of Vildagliptin and 0.08mg/ml Metformin HCl prepared as follows. Accurately weighed
10mgVildagliptin working standard and 100mg of Metformin HCl working standard to a 100ml
volumetric flask, add Mobile phase to about 60% of the final volume and sonicate for about 5 min to
dissolve. Make up the volume with mobile phase.
Pipette 2ml from the stock solution in 25ml volumetric flask. Pass through a suitable filter of 0.45- µm
pore size.
Sample solution:
0.008 mg/mL of Vildagliptin and 0.08mg/ml Metformin HCl prepared as follows. Crush the 10
tablets.Accurately weighed 145mg powder weight(equivalent to 10mg Vildagliptin and 100mg
Metformin HCl) powder to a 100ml volumetric flask. Add Mobile Phase to about 60% of the final
volume, shake mechanically for about 60 min, and make up the volume with mobile phase.
Pipette 2ml from the stock solution in 25ml volumetric flask. Pass through a suitable filter of 0.45- µm
pore size.
% Results:
PREPARED BY REVEIWED BY VERIFIED BY APPROVED BY
Q.C Analyst Deputy QCM QCM QAM / Plant Manager
Calculate the percentage of Metformin Hydrochloride(C4H11N5,HCl).in the portion of Tablets taken:
Result = (rU/rS) × 100
rU= peak response of metformin hydrochloridefrom the Sample solution
rS= peak response of metformin hydrochloride from the Standard solution.
5.Dissolution:
Dissolution Parameters:
o Medium : 0.01N HCl
o Apparatus : II (paddle method)
o Rpm : 100 rpm
o Time : 45 min
o Volume : 900 mL
o Temperature : 37±0.5°C
Medium preparation:
Take 0.85mL concentrated HCl in 1000mL water.
Mobile phase:
Acetonitrile: Phosphate Buffer: Water (65:20:15)
Buffer
6.75 g/L of Potassium Dihydrogen Phosphate in water. Adjust with1 M Sodium Hydroxide to a pH of
6.0(±0.01).
Diluent:
Mobile Phase.
Chromatographic Conditions:
Mode : LC
Detector : UV 239nm for Metformin HCl, UV 213nm for Vildagliptin
Analytical Column : 4.6mm x 25-cm, 5µm packing L1(C18)
Temperature : 25 °C
Flow rate : 1ml / min
Inject Volume : 10µL
System suitability
Tailing factor:
NMT 2.0 System suitability solution
Relative standard deviation:
NMT 2.0% Standard solution
Tolerances:
NLT 80% of the labeled amount Vildagliptin, Metformin hydrochlorideis dissolved.