Professional Documents
Culture Documents
L4 Daily RCM Observations, 30.11.2023
L4 Daily RCM Observations, 30.11.2023
L4 Daily RCM Observations, 30.11.2023
CLINKERING A
1 CP.L4.4262.LU03 HIGH
2 CP.L4.4210.BC15 HIGH
3 CP.L4.4210.BC15 HIGH
4 CP.L4.4210.BC15 HIGH
5 CP.L4.4240.BC03 HIGH
6 CP.L4.4241.BC01 HIGH
7 CP.L4.4250.AS14 HIGH
8 CP.L4.4250.VVA004 HIGH
9 CP.L4.4232.RS01 HIGH
10 CP.L4.4232.RS01 HIGH
CEMENTING A
1 CP.L4.4321.Area HIGH
CBM
CP.L4.4263.FN.04/07/
1 Minor
08/09/13/14
2 CP.L4.4270.FN.04 Unsatisfactory
3 CP.L4.4241.FN.01 Minor
4 CP.L4.4241.SR01 Minor
DAILY RCM INSPECTION FINDINGS
Line-4
ISSUES
CLINKERING AREA
Belt running sway need proper belt tensioning and training required.
Iron ore feed hopper side plates have a gap, material leakage observed ,need proper rectification.
Belt Drop chute DE hood bottom side plate worn, need to be rectified.
Material puffing at non material side of the belt H-Type cleaner not fixed properly , need proper fixation
Actuator both sides holding nuts missing and bolts found loose need to install and retight.
Coal leakage observed from coal pipe at near kiln inlet needs rectification.
Compressed air leakage observed from air pipe line fitting before dryer, needs rectification.
CEMENTING AREA
CBM
Fan impeller cleaning is required due to high vibration. (Max. Vibration: 6.5 mm/sec at Fan DE
Horizontal)
Fan impeller cleaning and balancing is required due to increase in vibration trend. (Max. Vibration: 4.3
mm/sec at Fan NDE Axial)
Couipling elements found worn out. Arrangment is required
Thursday, November 30, 2023
EXECUTION
FEEDBACK
DEPARTMENT
ELEC.L4
MECH.L4
MECH.L4
MECH.L4
MECH.L4
MECH.L4
MECH.L4
INPL.L4
MECH.L4
MECH.L4
ELEC.L4
ELEC.L4
MECH.L4
PROD.L1/MECH.L4
MECH.L4