NMS-KD-0035-2-en

N3000-SSP01
User Manual

Version 01.02
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

Document name
[NMS-KD-0035-2-en_V01.02_N3000-SSP01_User Manual.doc]

Scope of application
Document applicable to: Not specified

Change history
Document changes Change order

Version Date Changed Author Reason for changes Initiator


sections
V01.00 11.10.2011 All DHI Document preparation ALE
V01.01 21.12.2011 4. DHI Technical data updated (protection class) ALE
V01.02 22.03.2012 2.2 DHI System layout updated ALE

Printed in Germany
© 2012NORIS Marine Systems GmbH & Co. KG
This publication, including all of its parts, is copyright protected. Any exploitation or
utilisation requires the prior written consent of NORIS Marine Systems GmbH & Co. KG.
This restriction applies explicitly to reproduction, distribution, editing, translation and storage or processing in
electronic systems including databases and online services.
The right to make changes is reserved.

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 2 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

Table of contents
Symbols used ................................................................................................................................. 4

1. General safety information .............................................................................. 5


2. Overview ........................................................................................................ 6
2.1. Subject of this document ....................................................................................... 6

2.2. System layout ....................................................................................................... 7

2.3. Functional elements of the N3000‐SSP01 ................................................................ 9

3. Functional description ................................................................................... 10


3.1. Device functions .................................................................................................. 10

3.2. Further information ............................................................................................. 11

4. Technical data .............................................................................................. 12

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 3 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

Symbols used
Important information.
NOTICE

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 4 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

1. General safety information

The instructions in this section must be


NOTICE
carefully read and observed by all personnel
involved in the installation, operation and
maintenance or repair of the system.

Personnel qualifications and use for intended purpose

 All devices and system components should only be used for no other than their
intended purpose.

 Installation, operation, maintenance and repair should only be carried out by


qualified and authorised personnel.

Safety requirements for start-up

 All devices and system components must have been correctly installed in
accordance with the corresponding instructions and specifications prior to
system start-up.

 All maintenance and repair work must be completed prior to start-up.

Safety requirements for operation

 The operator must be familiar with the operation of the system and of the
individual system components.

 The operator must be aware of the effects and consequences of his actions.

 If an alarm is triggered or signalled by the system, suitable measures must be


initiated immediately in order to avoid hazardous situations and to rectify the
fault.

 The system and all system components must be fully functional to ensure
trouble-free operation. Suitable measures must be implemented immediately in
the event of a fault in the system or system components.

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 5 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

2. Overview

2.1. Subject of this document


Scope of application
The subject of this document is the description and use of the functions of the N3000-SSP01
group alarm annunciator.

Product description
The N3000-SSP01 is a group alarm annunciator for displaying up to 18 alarms (group and/or
individual alarms) by means of labelled illuminated annunciator fields and is installed in
preassembled sections in a switchgear cabinet, control desk or in a cabin wall. It is a slave unit
that is connected to a master controller.

Tasks and functions


 Signalling (visualisation) individual and group alarms from an alarm system (e.g. from
the N3000 system).

Target group for this document


 This document is intended for users of the N3000-SSP01 group alarm annunciator.

This document contains


 Descriptions on how to operate the device and of the device functions.

 Technical data of the device(s).

Please note that this document describes only


NOTICE
a part of your system. The entire system
documentation is always required to
understand the overall system interactions.

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 6 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

2.2. System layout


The N3000-SSP01 is a slave unit that can only be used together with a master controller. It is
normally used in a duty alarm monitoring and control system (see Fig. below).

Slave units are not independent device but rather require a master controller. Up to 31 slave
displays (display type N3000-DSP10, N3000-DSP20) and up to four group alarm annunciators
(N3000-SSP01) are connected via a serial kBus to the N3000-DMPxx. The devices receive
channel information from the N3000 system via this master. The following illustration shows an
example of the possible system layout.
The following illustration shows an example of the recommended system layout.

Fig. 1: System layout - example

Explanation of above illustration


 The N3000-DMPxx is installed in the engine control room. It is connected to the alarm
and monitoring system via a redundant CAN bus and/or Ethernet.

 The slave displays N3000-DSP10 and N3000-DSP20 are connected in the


accommodation and mess rooms as well as on the bridge alongside a group alarm
annunciator N3000-SSP01 on the bridge via the kBus.

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 7 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

 The kBus is layed and connected ideally directly from the engine control room (ECR) to
the bridge and then from the bridge to accommodation to guarantee the highest possible
availability of the connected devices on the bridge.

 In addition, the type N3000-DSP20 slave displays feature an independent fire alarm unit
and can be optionally connected to an external, independent fire alarm system. In this
way, a fire alarm can also be signalled via the slave displays in the quarters.

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 8 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

2.3. Functional elements of the N3000-SSP01


The figure below shows the functional elements of the N3000-SSP01.

Fig. 2: N3000-SSP01 - Front view with marking

Explanation of above illustration

Pos. Description

Illuminated header fields (in Fig.: green backlit indicator fields)


1. e,g, for showing header of subordinate indicator fields;
they can also be used as normal alarm indicator fields

2. 16 illuminated alarm indicator fields


Individual or group alarms

Status indicator

3. Shows the operating status of the device.


Green = OK
Red flash = communication / master controller error

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 9 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

3. Functional description

3.1. Device functions


Control via software
The 18 illuminated indicator fields on the N3000-SSP01 are individually actuated via the kBus
by the software installed in the master controller. Both group alarms as well as individual alarms
can be signalled.

Control via hardware wiring


The N3000-SSP01 additionally features 4 binary inputs for directly wiring up to 4 freely
selectable illuminated indicator fields. This makes it possible to signal important group or
individual alarms independent of the kBus. These alarms are still signalled in the event of the
master controller failing. An application example of this function are the illuminated indicator
fields for "ME Automatic Stop" and "ME Reduce" that are connected directly from the safety
system to the respective illuminated indicator fields.

Fig. 3: N3000-SSP01 - Front view

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 10 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

Failure monitoring
Operation of the N3000-SSP01 is monitored. Failure of the device is signalled in the system by
"Sensor failure" (SF). The device status is indicated by the status LED located below the
illuminated indicator fields. The status LED lights red in the case of failure or a break in the
kBus connection. It remains off when the 24 V power supply is not applied.

Dimming
The N3000-SSP01 can be connected to a device with a dimming function and adopt its dimmer
setting. If the device with the dimming function is equipped with a light sensor (such as the
N3000-DSP10 or -DSP20 display) the brightness level will be automatically adapted to the
ambient brightness.

3.2. Further information


Document ID Description
NMS-KD-0023-1 N3000-DMPxx_Installation instructions
NMS-KD-0023-2 N3000-DMPxx_User manual
NMS-KD-0026-1 N3000-DSP10/20_Installation instructions
NMS-KD-0026-2 N3000-DSP10/20_User Manual
NMS-KD-0035-1 N3000-SSP01_Installation instructions
NMS-KD-0035-2 N3000-SSP01_User manual

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 11 / 12
NMS-KD-0035-2-en N3000-SSP01
Version 01.02
22.03.2012 - DHI User Manual

4. Technical data
Operating voltage 18 … 32 V DC
Power consumption <6W
Operating temperature as per IEC60068-2-2 and IEC60068-2-1Ad -25 °C … +70 °C
range
Storage temperature range as per IEC60068-2 -40°C … +85°C
Relative humidity as per IEC60068-2-30 Db ≤ 96 % @ 55 °C
Vibration resistance as per IEC60068-2-6 Fc ±1.0mm @ 2…13 Hz, 0.7g @ 13…100 Hz
Shock resistance (impact) as per IEC60068
ESD as per IEC61000-4-2 8 kV air, 6 kV contact
Electromagnetic field as per IEC61000-4-3 10 V/m f = 80 MHz … 2000 MHz 80% AM @ 1 kHz
10 V/m f = 900 ±5 MHz 50% AM @ 200 Hz
10 V/m f = 1800 ±5 MHz 50% AM @ 200 Hz
Burst as per IEC61000-4-4 ±2 kV operating voltage
±1 kV sensor lines
Surge as per IEC61000-4-5 sym. ± 0.5 kV (R i =2Ω); asym. ± 1 kV (R i =12Ω)
Conducted RF interference as per IEC61000-4-6 10 V rms f = 0.01 …100 MHz 80% AM @ 1 kHz
Conducted AF interference as per IEC60553 10 V rms f = 0.05 …10 kHz
Interference-field strength as per CISPR 16-1– EMC1
Connections Push-lock terminals Phoenix Mini-Combicon spring terminal
Operating voltage 24 V
kBus (RS485), digital inputs up to core Ø ≤ 2.5 mm²
Characteristic values of Switches/buttons I approx. 4 mA @ U E = 24V per input
sensor inputs
Protection class as per DIN EN60529 Front IP54 installed in mounting
plate
Other sides IP10, connection IP00
Installation position Any
Enclosure material Front: Polyurethane
Rear panel: Chromated aluminium panel
Mounting In switchgear cabinet section with 4 stud bolts M5 x 16 mm
Contact washers and nuts
Dimensions Front panel L: 145 mm, W: 164 mm, D: 9 mm
Body L: 117 mm, W: 111 mm, D: approx. 23 mm not including
cable space
Weight Approx. 0.4 kg
Applicable standards IEC61000-6-2; IEC61000-6-4; IACS Req. 1993/Corr.1, 2003, Section E10

NORIS Marine Systems GmbH & Co. KG, Muggenhofer Strasse 95, 90429 Nuremberg, Germany
Phone: +49 911 3201-0, Fax: +49 911 3201-150, info@noris-group.com, www.noris-group.com

Seite 12 / 12