Professional Documents
Culture Documents
Santa Elena
Santa Elena
PVsyst TRIAL
PVsyst - Simulation report
Standalone system
PVsyst TRIAL
SANTA ELENA(Carrizal) - Ecuador
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: SANTA ELENA
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 22:55
PVsyst TRIAL
with v7.4.0
Project summary
Geographical Site Situation Project settings
SANTA ELENA(Carrizal) Latitude -2.09 °S Albedo 0.20
Ecuador Longitude -80.50 °W
Altitude 207 m
Time zone UTC-5
Meteo data
SANTA ELENA(Carrizal)
NREL NSRDB Typ. Met. Year PSMv3_1998 to 2020 - TMY
System summary
PVsyst TRIAL
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 64 units Technology Lead-acid, sealed, Gel
Pnom total 17.28 kWp Nb. of units 360 units
Voltage 96 V
Capacity 2385 Ah
Results summary
PVsyst TRIAL
Useful energy from solar
Missing Energy
Excess (unused)
17511.67 kWh/year
217.11 kWh/year
2567.71 kWh/year
Table of contents
Solar Fraction SF
66.39 %
98.78 %
2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
PVsyst TRIAL
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 2/7
Project: SANTA ELENA
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 22:55
PVsyst TRIAL
with v7.4.0
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Imported
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 49 kWh/Day
PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 270 Wp
PV Array Characteristics
Generic
END-60-270P
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
12V 1 RES OPzV 65
Lead-acid, sealed, Gel
45 in parallel x 8 in series
Number of PV modules 64 units Discharging min. SOC 20.0 %
Nominal (STC) 17.28 kWp Stored energy 183.2 kWh
Modules 64 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 96 V
Pmpp 15.34 kWp Nominal Capacity 2385 Ah (C10)
U mpp 27 V Temperature Fixed 20 °C
I mpp 559 A
PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.
97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.90 / 0.75
106.6 / 99.1 V
SOC = 0.20 / 0.45
92.5 / 96.5 V
Total PV power
Nominal (STC) 17 kWp
Total 64 modules
Module area 105 m²
Cell area 94.1 m²
Array losses
PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)
-0.8 %
DC wiring losses
Global array res.
Loss Fraction
0.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction
0.2 %
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 3/7
Project: SANTA ELENA
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 22:55
PVsyst TRIAL
with v7.4.0
PVsyst TRIAL
Total daily energy 48572
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 4/7
Project: SANTA ELENA
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 22:55
PVsyst TRIAL
with v7.4.0
Main results
System Production
Useful energy from solar 17511.67 kWh/year Perf. Ratio PR 66.39 %
Available solar energy 21116.61 kWh/year Solar Fraction SF 98.78 %
Excess (unused) 2567.71 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 1.2 % Cycles SOW 96.6 %
Missing Energy 217.11 kWh/year Static SOW 93.3 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
132.6
113.9
153.8
147.5
GlobEff
kWh/m²
97.1
92.1
136.9
145.0
E_Avail
kWh
1398
1323
1958
2057
EUnused
kWh
0.0
0.1
202.5
488.9
E_Miss
kWh
141.1
76.0
0.0
0.0
E_User
kWh
1365
1284
1506
1457
E_Load
kWh
1506
1360
1506
1457
SolFrac
ratio
0.906
0.944
1.000
1.000
May 142.0 150.9 2130 536.6 0.0 1506 1506 1.000
June 125.1 137.8 1950 405.7 0.0 1457 1457 1.000
July 120.8 128.7 1811 180.0 0.0 1506 1506 1.000
August 129.3 131.3 1851 283.6 0.0 1506 1506 1.000
September 146.1 135.2 1897 331.4 0.0 1457 1457 1.000
October 139.6 116.1 1655 138.9 0.0 1506 1506 1.000
November 141.7 105.6 1512 0.0 0.0 1457 1457 1.000
PVsyst TRIAL
December 154.3 108.8 1575 0.0 0.0 1506 1506 1.000
Year 1646.7 1485.5 21117 2567.7 217.1 17512 17729 0.988
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 5/7
Project: SANTA ELENA
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 22:55
PVsyst TRIAL
with v7.4.0
Loss diagram
1647 kWh/m² Global horizontal irradiation
+0.75%
-0.15%
-3.47%
PV loss due to temperature
PVsyst TRIAL
-0.06% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
18549 kWh Converter losses (effic, overload)
Missing Direct use Stored Battery Storage
energy 35.5% 64.5%
-0.44% Battery Stored Energy balance
1.22% -4.64% Battery efficiency loss
217.1 kWh
-1.92% Charge/Disch. Current Efficiency Loss
-0.52% Gassing Current (electrolyte dissociation)
-0.81% Battery Self-discharge Current
17512 kWh Energy supplied to the user
PVsyst TRIAL
17729 kWh Energy need of the user (Load)
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 6/7
Project: SANTA ELENA
Variant: Nueva variante de simulación
PVsyst V7.4.0
VC0, Simulation date:
21/08/23 22:55
PVsyst TRIAL
with v7.4.0
Predef. graphs
Diagrama entrada/salida diaria
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/08/23 PVsyst Evaluation mode Page 7/7