CUSTOMER PROCESS SUMMARY A license purchased from Oracle/Micros is required to get this interface
enabled for a PMS. The associated cost will vary from customer to customer,
1. Contact Oracle account manager (for depending on their agreement with Oracle.
existing PMS installations) or local
Schneider Electric representative (for • Contact your Oracle account manager or local Schneider Electric
new PMS installations). representative for more information.
• Schneider Electric will assist in the integration and ensure both systems
2. Oracle account or Schneider Electric are communicating per the specification. Contact your local Schneider
representative will provide a quote for Electric representative for more information about the installation.
the license and installation time.
Refer to the following website for more information about Micros Fidelio and
3. Send purchase order to Oracle. Micros Opera PMS:
4. Oracle project manager arranges https://www.oracle.com/industries/hospitality/hotels-resorts/solutions/index.
installation date and time. Liaise html#property
with Schneider Electric to ensure a
SmartStruxure solution installation Value Proposition
engineer is available on the same date.
By integrating their PMS system with the SmartStruxure solution BMS, hotel
5. Installation is carried out on the agreed operators are ensuring greater guest comfort and satisfaction while enabling
date – usually remotely but may be greater energy efficiency. In fact, when a room is newly rented, the PMS will
done on site, especially if a new build is provide information to the SmartStruxure solution about whether the room
involved. is rented or not, the guest name, the guest’s preferred language, and the
duration of stay.
For example, this information will enable the SmartStruuxre solution to
immediately instruct the SE8000 room controllers to switch from unrented
to rented mode, to switch from deep temperature setback mode to standby
mode, to pre-cool or pre-heat the room before the guest enters to change the
SE8000 user interface to the guests preferred language and even greet him
with a personalized greeting such as, “Welcome Mr. Smith.”
Important: Currently this solution is released for specific pilot programs. It’s official release is targeted
for Q3-2015. For more information on implementation in potential projects prior to then, please contact
the Small Building Systems team directly.
3
Linked rooms can operate as individual rooms allowing for check-in and check-
out messages to be received for both rooms and the room state updated
accordingly.
System Architecture
4
Clicking on one of the floors in the main dashboard display brings up the dashboard for that floor, where the operator can access
widgets that provide data about individual guestrooms and allow for the management of the room controllers in those rooms.
Schneider Electric Boston ONE Campus, 800 Federal Street, Andover, MA 01810-1067 Tel: +1 978 794 0800
SDS-PMS-Energy-Management-Dashboard-A4.EN.05.2015.v2 www.schneider-electric.com/buildings May 2015