GVP Valve & Manifold Assembly

Instructions
SINGLE STATION A
MANIFOLDS
PORT NC NO
B
GSC-300 (300mm CABLE)
GSC-500 (500mm CABLE) A INPUT EXHAUST C
B EXHAUST INPUT
C OUTPUT OUTPUT
GVP-10MM USE M1.7X0.35 - 14
GVP -15MM USE M3X0.5 - 18 GM-311
PAN HEAD PHILLIPS SCREW

A
GVP SOLENOID VALVES B
(SIZE 10 OR 15mm) C

GM-321
BLANKING PLATE
INLET
PORT

EXHAUST PORT OUTLET


LABELED "E" PORT
GM-321-18N
OUTLET INLET PORT
PORTS LABELED "P"

PART NUMBER VALVE SIZE INLET THREAD OUTLET THREAD EXHAUST THREAD
GM-311 GVP-21 / GVP-31 #10-32 #10-32 #10-32
GM-312 GVP-21 / GVP-31 #10-32 #10-32 #10-32
GM-314 GVP-21 / GVP-31 #10-32 #10-32 #10-32
GM-316 GVP-21 / GVP-31 #10-32 #10-32 #10-32
GM-321 GVP-22 / GVP-32 #10-32 #10-32 #10-32
GM-322 GVP-22 / GVP-32 1/8" NPT #10-32 1/8" NPT
GM-324 GVP-22 / GVP-32 1/8" NPT #10-32 1/8" NPT
If you have any questions concerning the
GM-321-18N GVP-22 / GVP-32 1/8" NPT 1/8" NPT N/A installation or operation of this equipment,
or if you need additional information,
Revision 2 02/19 please call AutomationDirect.com Tech
Support at 770-844-4200
GVP Latching Valve Wiring
Instructions

BROWN
BLACK or YELLOW/GREEN
BLUE
BLACK "-"
RED "+"

Part No. GVP-321CL-12D Part No. GVP-311CL-24D

Function: 15 mm Valve Function: 10 mm Valve


The 15 mm valves feature a 3-wire system to change state; relays are not required. The 10 mm valve features a 2-wire system to change state. Applying an
Applying an electrical signal to the Brown wire energizes (latches) the valve. The electrical signal to the Red wire and ground to the Black wire energizes (latches)
internal magnet holds the valve in the energized (open) position when the power the valve. An internal magnet holds the valve in the energized (open) position
supply is removed. Applying an electrical signal to the Blue wire de-energizes when the power supply is removed. Reversing the wires, ground to Red and
(unlatches) the valve. electrical signal to Black, de-energizes (unlatches) the valve.

3-Wire System 2-Wire System


Brown – Latch / Energize / + Power to Red, Ground to Black – Latch / Energize
Black or Yellow/Green – Common / - Ground to Red, Power to Black – Unlatch / De-energize
Blue – Unlatch / De-energize / +