Professional Documents
Culture Documents
Ratu Diva Angelika - Tugas 2 - Optimasi Sistem Energi - 5EGC
Ratu Diva Angelika - Tugas 2 - Optimasi Sistem Energi - 5EGC
Kelas : 5EGC
260
Dosen Pengampu :
240
Isnandar Yunanto, S.ST., M.T.
220
CP Actual Temperature ∆H
No Type 200
[kW/K] TS [oC] TT [oC] [kW]
1 Hot 3 200 50 450
180
2 Hot 1.5 240 100 210
3 Hot 3 120 119 300
160
4 Cold 4 30 200 -680
5 Cold 2 50 250 -400
140
120
∆H Cold Stream : 960
∆H Hot Stream : -1080
100
20
0
0 100 200 300 400 500
Hot utility Maximum Energi Recovery (MER)
20 kW 960 kW
600 700 800 900 1000 1100
ergi Recovery (MER) Hot Utility
960 kW 100 kW
Nama : Ratu Diva Angelika (062040412288)
Kelas : 5EGC
Mata Kuliah : Optimasi Sistem Energi
Dosen Pengampu : Isnandar Yunanto, S.ST., M.T. Shifted temperatur
S
Steam Cp Temperatur Aktual Shifted Temperatur 255
NO
Type (kW/K) Ts Tt Ss St
1 Hot 3 200 50 195 45 235
2 Hot 1.5 240 100 235 95
3 Hot 300 120 119 115 114 205
4 Cold 4 30 200 35 205
5 Cold 2 50 250 55 255 195
10
115
114
95
PROBLEM TABLE
Shifted temperatur Surplus/ C
Interval
S (KW/oc) (KW) Deficit 3
255
1 20 -2 -40 Surplus
235
2 30 -0.5 -15 Deficit
205
3 10 -4.5 -45 Deficit
195 200
9 10 -4 -40 Surplus
35
From hot utility
LE 255 ˚C
CP (KW/OC) 1 ∆H = -40 kW
1.5 300 4 2
235 ˚C
250
2 ∆H = -15 kW
240
205 ˚C
200 3 ∆H = -45 kW
195 ˚C
4 ∆H = -120 kW
120
115 ˚C
119 5 ∆H = 298.5 kW
114 ˚C
100
6 ∆H = -28.5 kW
50
95 ˚C
7 ∆H = -120 kW
55 ˚C
30
8 ∆H = -10 kW
45 ˚C
9 ∆H = -40 kW
35 ˚C
To Cold Unility
a. Infeasible
From hot utility
0 kW 220 kW
1 ∆H = -40 kW
-40 kW 180 kW
2 ∆H = -15 kW
-55 kW 165 kW
3 ∆H = -45 kW
-100 kW 120 kW
4 ∆H = -120 kW
-220 kW 0 kW
5 ∆H = 298.5 kW
78.5 kW 298.5 kW
6 ∆H = -28.5 kW
50 kW 270 kW
7 ∆H = -120 kW
-70 kW 150 kW
8 ∆H = -10 kW
-80 kW 140 kW
9 ∆H = -40 kW
-120 kW 100 kW
To Cold Unility
b. Feasible
T H
255 220 GCC
235 180 300
205 165
250
195 120
Temperatur (celcius)
115 0 200
114 298.5 150
95 270
100
55 150
45 140 50
35 100
0
0 50 100 150 200 250 300 350
Entalpi (kW)
250 300 350
CP Actual Temperature ∆H
No Type
[kW/K] TS [ C]
o
TT [ C]
o
[kW]
1 Hot 3 200 50 450
2 Hot 1.5 240 100 210
3 Hot 300 120 119 300
4 Cold 4 30 200 -680
5 Cold 2 50 250 -400
Tmin = 10 oC
Grid Diagram
Above Pinch
CP hot < CP Cold
CP (MW/K) 240 Pinch 115 oC
3 1 200 1 120
180
240 2 120
1.5 2
120 120
300 3
120 240
100 180
MER = 860
Hot Utility = 220
Cold Utility= 110
Grid Diagram
Below Pinch
CP hot > CP Cold
Pinch 115 oC 120
3 80 50
C
90
100
320
4 118.93333 119
C
20
30 4
320
50
5
120
HE Unit 4
Hot Utility Unit 2
Cold Utility Unit 2