Nama Kelompok : T (oC)

Ratu Diva Angelika


280

Kelas : 5EGC
260

Dosen Pengampu :
240
Isnandar Yunanto, S.ST., M.T.

220

CP Actual Temperature ∆H
No Type 200
[kW/K] TS [oC] TT [oC] [kW]
1 Hot 3 200 50 450
180
2 Hot 1.5 240 100 210
3 Hot 3 120 119 300
160
4 Cold 4 30 200 -680
5 Cold 2 50 250 -400
140

120
∆H Cold Stream : 960
∆H Hot Stream : -1080
100

Dengan menggunakan tabel dari latihan 2.1 dan menggunakan ∆T min = 10 oC


80
a. Membuat kurva komposit
b. Menentuian tugas utilitas pemanas
60
c. Menentukan tugas utilitas pendingin
d. Menentukan MER (Maximum Pemulihan Energi)
40

20

0
0 100 200 300 400 500
Hot utility Maximum Energi Recovery (MER)
20 kW 960 kW
600 700 800 900 1000 1100
ergi Recovery (MER) Hot Utility
960 kW 100 kW
Nama : Ratu Diva Angelika (062040412288)
Kelas : 5EGC
Mata Kuliah : Optimasi Sistem Energi
Dosen Pengampu : Isnandar Yunanto, S.ST., M.T. Shifted temperatur

S
Steam Cp Temperatur Aktual Shifted Temperatur 255
NO
Type (kW/K) Ts Tt Ss St
1 Hot 3 200 50 195 45 235
2 Hot 1.5 240 100 235 95
3 Hot 300 120 119 115 114 205
4 Cold 4 30 200 35 205
5 Cold 2 50 250 55 255 195
10
115

114

95
PROBLEM TABLE
Shifted temperatur Surplus/ C
Interval
S (KW/oc) (KW) Deficit 3
255
1 20 -2 -40 Surplus
235
2 30 -0.5 -15 Deficit
205
3 10 -4.5 -45 Deficit
195 200

4 80 -1.5 -120 Deficit


115
5 1 298.5 298.5 Surplus
114
6 19 -1.5 -28.5 Deficit
95
7 40 -3 -120 Deficit
55
8 10 -1 -10 Deficit
45 50

9 10 -4 -40 Surplus
35
From hot utility

LE 255 ˚C

CP (KW/OC) 1 ∆H = -40 kW
1.5 300 4 2
235 ˚C
250

2 ∆H = -15 kW
240
205 ˚C

200 3 ∆H = -45 kW

195 ˚C

4 ∆H = -120 kW
120
115 ˚C

119 5 ∆H = 298.5 kW

114 ˚C
100

6 ∆H = -28.5 kW
50
95 ˚C

7 ∆H = -120 kW

55 ˚C
30

8 ∆H = -10 kW

45 ˚C

9 ∆H = -40 kW

35 ˚C

To Cold Unility
a. Infeasible
From hot utility

0 kW 220 kW

1 ∆H = -40 kW

-40 kW 180 kW

2 ∆H = -15 kW

-55 kW 165 kW

3 ∆H = -45 kW

-100 kW 120 kW

4 ∆H = -120 kW

-220 kW 0 kW

5 ∆H = 298.5 kW

78.5 kW 298.5 kW

6 ∆H = -28.5 kW

50 kW 270 kW

7 ∆H = -120 kW

-70 kW 150 kW

8 ∆H = -10 kW

-80 kW 140 kW

9 ∆H = -40 kW

-120 kW 100 kW

To Cold Unility
b. Feasible
T H
255 220 GCC
235 180 300
205 165
250
195 120

Temperatur (celcius)
115 0 200
114 298.5 150
95 270
100
55 150
45 140 50
35 100
0
0 50 100 150 200 250 300 350

Entalpi (kW)
250 300 350
CP Actual Temperature ∆H
No Type
[kW/K] TS [ C]
o
TT [ C]
o
[kW]
1 Hot 3 200 50 450
2 Hot 1.5 240 100 210
3 Hot 300 120 119 300
4 Cold 4 30 200 -680
5 Cold 2 50 250 -400
Tmin = 10 oC

Grid Diagram
Above Pinch
CP hot < CP Cold
CP (MW/K) 240 Pinch 115 oC

3 1 200 1 120

180
240 2 120
1.5 2

120 120
300 3

200 H 170 110


4

120 240

250 H 200 110


2

100 180

MER = 860
Hot Utility = 220
Cold Utility= 110
Grid Diagram
Below Pinch
CP hot > CP Cold
Pinch 115 oC 120
3 80 50
C

90

100

320
4 118.93333 119
C

20

30 4

320

50
5

120

HE Unit 4
Hot Utility Unit 2
Cold Utility Unit 2