Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Ensure No part of Foundation KEY PLAN:

upstand will be exposed

2350 1750 5300 1625 1925 1925 1625 5300 1750 2350
TYP 300 TYP
800 3545 105 1 300 1
105 3545 800
0427
105 0427 Ensure No part of Foundation
250 300 250 1900 1 STEP 2 STEPS 3 STEPS 105 3 STEPS 2 STEPS 1 STEP upstand will be exposed
1900 250 300 250

300

300

300

300

300
300

300

300

300

300

1100
1100

1250
1250

1400
TYP TYP

1400

800
800

950
GENERAL NOTES:

950
2 2

1100
1100
0427 0427

2565
2565

3420
3420
DRAWING REFERENCES:

3120
3120
DESCRIPTION DWG. REF. NO REV.

TOU TOU

20
20

315
315

350
350

3050
3050

LEGEND:

4910
4910
1 1
0427 TYP TYP 0427
1 1
0427 0427

300 800 800 300 300 800 800 300


1 STEP 1100 1100 1 STEP 1 STEP 1100 1 STEP

1860
1100
1860

SSL (RAFT) SSL (RAFT)


250 MM THK 250 MM THK
300 950 950 300 300 950 950 300
2 STEPS 1250 1250 2 STEPS 2 STEPS 1250 2 STEPS
1250
Finishing thickness to be considered
300 1100
for final panels alignment
1100 300 300 1100 1100 300

1690
1690

3 STEPS 1400 1400 3 STEPS 3 STEPS 1400 3 STEPS


1400

2915
2915
1300 1300
800 500 500 800

1225
1225

640 65
640 65

1145
1000
1145

Annex wall to be aligned 1000 Annex wall to be aligned


with Garage and Pergola with Garage and Pergola
wall 300 300 wall

300
300

3450

3450
3450

3450

2325
2325

2305
2305

TYP TYP
1 1
0427 0427

1855

1920
1855
1920

1920

1920
REV. DATE NAME DESCRIPTION

PROJECT:

300
300

65
65

TOU TOU
1105 2795 300 2205 2205 300 2795 1105

10450
10450

REF: NOTE - 1 REF: NOTE - 1


CLIENT :

3880

3880
3880

3880

3 3 CONSULTANT:
TYP 0427 280 1925 1925 2800427 TYP
2 2
2375 700 300
0427 0427
300 700 2375

645
645

MAIN CONTRACTOR:

1420
1420

300
300

255
255

300 300
TOU 905 TOU
905

2970
2970

TYP TYP
1 1 SUB CONTRACTOR:

2325

2325
2325

2325

2 0427 0427 2
0427 0427

REF: NOTE - 1 REF: NOTE - 1

1550
1550

PROJECT NO : i109
250 300 250 5775 250 300 250 250 300 250 5775 250 300 250
STAGE:
800 3650 2125 800 800 2125 3650 800
DRAWING TITLE:

Ensure No part of Foundation Ensure No part of Foundation Ensure No part of Foundation Ensure No part of Foundation (HARMONY - 3) (VILLA TYPE - H2.5B)
upstand will be exposed upstand will be exposed upstand will be exposed upstand will be exposed FOUNDATION CONCRETE DIMENSION,
STEP CODE & NUMBER OF STEPS AS / EXCAVATION LAYOUT & SECTIONS
MASTERPLAN STEP CODING REV.02 CHECKED & COORDINATED BY ASGC ENG.
HR3_H2.5B - FOUNDATION CONCRETE DIMENSION LAYOUT - GROUND LEVEL HR3_H2.5B(M) - FOUNDATION CONCRETE DIMENSION LAYOUT - GROUND LEVEL APPROVED BY.
A 1 : 50
B 1 : 50
ARCH. STRUCT. MECH. ELECT. HVAC
(TM)

H.A.S
NAME

SIGN.

DRAWING NUMBER:

FOR VILLA TYPE H2.5B FOUNDATION REINFORCEMENT DETAILS REF. SHEETS: UAE045-801-IBD-HR2-H24A-GFL-SE-SDW-(0178 : 0195)
PROJECT UNIQUE
PACKAGE UNIT/AREA LEVEL DWG. NO. REVISION
CODE

FOR ANNEX FOUNDATION CONCRETE DIMENSION REF. SHEET: UAE045-801-IBD-HR1-PRW-GFL-SE-SDW-0095


UAE045-801 IBD HR3 H2.5B SE SDW 0426 01

SCALE: As indicated DATE: 13-09-2022


FOR ANNEX FOUNDATION REINFORCEMENT DETAILS REF. SHEET: UAE045-801-IBD-HR1-GEN-GFL-SE-SDW-0096 PREPARED BY CHECKED PAPER SIZE DIMS IN SHEET No.

PY GM A1 mm 1 / 3