Professional Documents
Culture Documents
Load Calculation
Load Calculation
Calculation Months ................................ Jan to Dec Zone L/s Sizing .................. Sum of space airflow rates
Sizing Data ............................................ Calculated Space L/s Sizing .............. Individual peak space loads
Actual max L/s ................................................... 370 L/s Fan motor BHP ....................................................... 0.00 BHP
Standard L/s ...................................................... 370 L/s Fan motor kW ......................................................... 0.00 kW
Actual max L/(s·m²) .......................................... 0.62 L/(s·m²) Fan static ..................................................................... 0 Pa
Calculation Months ................................ Jan to Dec Zone L/s Sizing .................. Sum of space airflow rates
Sizing Data ............................................ Calculated Space L/s Sizing .............. Individual peak space loads
Time of
Cooling Peak Air Heating Floor
Zone Name / Sensible Sensible Flow Load Area Space
Space Name Mult. (kW) Load (L/s) (kW) (m²) L/(s·m²)
F1 BEDROOM 2
F1 BEDROOM 2 1 3.0 Aug 1600 261 0.1 17.5 14.92
F1 BEDROOM 3
F1 BEDROOM 3 1 4.5 Aug 1600 395 0.3 35.2 11.22
F1 DRESS ROOM M
F1 Dress Room M 1 4.0 Jul 1500 348 0.3 65.9 5.28
F1 HALL
F1 Hall 1 7.1 Sep 1500 620 0.3 62.4 9.94
F1 LAUNDRY
F1 Laundry 1 1.2 Jul 1700 108 0.1 11.1 9.74
F1 MASTER BEDROOM 1
F1 MASTER BEDROOM 1 6.1 Aug 1500 534 0.5 62.4 8.55
F1 STORAGE/OFFICE
F1 Storage/Office 1 3.2 Oct 1400 283 0.1 17.0 16.66
GF BEDROOM
GF BEDROOM 1 4.5 Aug 1600 396 0.2 22.7 17.43
GF DINING AREA
GF DINING AREA 1 4.7 Aug 1500 410 0.1 37.4 10.96
GF DIRTY KITCHEN
GF DIRTY KITCHEN 1 4.1 Jul 1500 358 0.1 20.7 17.28
GF ENTERTAINMENT
GF ENTERTAINMENT ROOM 1 3.4 Jun 1700 303 0.2 42.1 7.19
GF WINE CELLAR 1 1.2 Jul 1500 108 0.0 9.3 11.59
GF FAMILY ROOM
GF FAMILY ROOM 1 1.7 Jan 2300 147 0.0 37.4 3.94
GF HALL STAIRS
GF HALL STAIRS 1 2.3 Jul 1500 198 0.0 30.0 6.60
Time of
Cooling Peak Air Heating Floor
Zone Name / Sensible Sensible Flow Load Area Space
Space Name Mult. (kW) Load (L/s) (kW) (m²) L/(s·m²)
GF STAFF ROOM
GF STAFF ROOM 1 1.5 Jul 1600 136 0.1 13.9 9.77
GF KITCHEN
GF KITCHEN 1 3.8 Jun 1500 335 0.0 19.0 17.61
GF LAUNDRY
GF LAUNDRY 1 1.5 Jul 1500 135 0.0 6.2 21.81
GF HALL TO DINE 1 0.8 Jul 1500 67 0.0 4.0 16.66
GF MAID
GF MAID 1 2.0 Jul 1500 172 0.0 9.7 17.77
GF OPEN AREA
GF NEW AREA 1 6.4 Oct 1300 563 0.6 69.0 8.16
1. Summary
Ventilation Sizing Method ................................ Sum of Space OA Airflows
Design Ventilation Airflow Rate .............................................................. 370 L/s
Air Density x Heat Capacity x Conversion Factor: At sea level = 1.207; At site altitude = 1.206 W/(L/s-K)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 2947.6; At site altitude = 2945.9 W/(L/s)
Site Altitude = 4.9 m
Air Density x Heat Capacity x Conversion Factor: At sea level = 1.207; At site altitude = 1.206 W/(L/s-K)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 2947.6; At site altitude = 2945.9 W/(L/s)
Site Altitude = 4.9 m