Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

LEGEND

Master Layout Plan with Fire Protection System Sym Description Cft. Qnt.
Site Area: 6194 sqm, 66,650 sft Upright Sprinkler, K-11.2 UL
Pendent Sprinkler, K-8.0 UL
Upright Sprinkler, K-5.6 UL
Pendent Sprinkler, K-5.6 UL
FHC_ CL - lll
Hose, Class-III UL
Landing Valve (65mm) LPCB 01
Non Return Valve UL 02
Y-Strainer UL
Butterfly Valve (Sup,) UL
OS & Y Gate Valve(Sup) UL 08
Ball Valve BSI
R.C.C Single Storied Building

(R.C.C Single
RMS ROOM
Flow Switch UL

Fire Pump Room


(Guard Room, Day Care &

Storied)
65 MM CLASS I CONNECTION
2X75KW & 1X55KW Medical)
Pillar Hydrent

Reject Store
13 sqm
Pressure Gauge

(R.C.C Single
Pillar Hydrent
Compressor Room UL

Storied)
150 MM RING PIPE OVER GROUND 150 MM RING PIPE OVER GROUND 150 MM RING PIPE OVER GROUND 150 MM RING PIPE OVER GROUND
100 MM RING PIPE OVER GROUND
Riser Point N/A 05
40 MM CLASS II CONNECTION
40 MM CLASS II CONNECTION R.C.C Single Storied Building
UNDERGROUND WATER
(Guard Room, RESERVOIR
Day Care & Drain Riser Point N/A 03
150 MM RING PIPE OVER GROUND

Size:75'-9"x14'-9"x10' (Inside)
Medical)
74 sqm
Test & Drain Valve (50mm) UL

18'-0"
Capacity: 83,580 US Gallon
Fire Pump Can Suc: 75,223 Gallon at 9'
Water Height Zone Control Assembly UL

CONNECT TO MAIN RING LINE


77'-0"
Pillar Hydrant (2-Way) LPCB 09

Pillar Hydrent
BURNER LINE
Beaching Inlet (4-Way) LPCB

Four Storied Building (Steel Structure)


02

Main Production of DNV Clothing Ltd.


Stair-1
Fire Pump (Set) UL 01

150 MM RING PIPE OVER GROUND


Flexible Joint BSI

Lift-1
Pillar Hydrent
Air Vent UL
UL
Pressure Relief Valve (6 Inch)
FM Water Flow Meter (6 Inch) FM
65 MM CLASS I CONNECTION

Alarm Check Valve (6 Inch) UL 01


40 MM CLASS II CONNECTION

Pressure Reducing Valve UL 01


150 MM RING PIPE OVER GROUND

Casing Relief Valve UL


2-Hours Rated Fire Door (DS) UL
2-Hours Rated Fire Door (SS) UL
2-Hours Rated Fire Wall (Brick)

DNV Clothing(Extension)
Pillar Hydrent

DNV Clothing Ltd. EXT.


Single Storied Shed 100/101 Adamjee EPZ,
Sidhdirgonj,Narayangonj,
AID: 24769 AND Bangladesh
28106mmX3000mm
JHUTE GODOWN

HEIGHT 3600mm

FFC ID:9499
ANANTA GROUP

Md. Ashikur Rahman


150 MM RING PIPE OVER GROUND

ID: 9348
M.Eng in ME

BURNER LINE
40 MM CLASS II CONNECTION

Md. Ashikur Rahman

Pillar Hydrent
65 MM CLASS I

40 MM CLASS II CONNECTION 40 MM CLASS II CONNECTION


CONNECTION

PhD in ME (BUET)
150 MM RING PIPE OVER GROUND 150 MM RING PIPE OVER GROUND 150 MM RING PIPE OVER GROUND
65 MM CLASS I CONNECTION

Lift-2
232'-10"
150 MM UNDERGROUND RING PIPE

Pillar Hydrent

Pillar Hydrent

Stair-2

Stair-3
RAM Corporation
Corporate Office: 1/1D,
UTILITY AREA
Hatkhola Road, 10th Floor, Wari,
RMS Room
44.00 sqm
Pillar Hydrent
Dhaka-11203, Bangladesh.
Single Storied Shed Building Single Storied Shed Building

HT POLE BURNER LINE


(Worker Locker Area) (Kitchen Area) Email: info@ramcorporationbd.com

This is hatch mark area is indicated RSC This is hatch mark area is indicated RSC
AID:24769 AND FFC ID:9499 Master Layout of Factory
audit scope under ID-9348 Building
03

You might also like