Professional Documents
Culture Documents
Alltrend 1
Alltrend 1
Alltrend 1
7 7 8
8 8
The next three rungs show a different way, and in someways a simpler way, you could do a flip flop.
Each time the button is pressed the counter will increment by 1. The first bit in the counter accumulator will change state.
IE
0000 = 0
0001 = 1
0010 = 2
0011 = 3
0100 = 4
0101 = 5
By looking at only that bit you have something that changes state each tme the button is pressed. The counter preset can be zero, there is no need to reset the counter
except to reset the flip flop.
VACUUM ROUGH
VALVE BUTTON
9PB
I:0 CTU
0001 Count Up CU
10 Counter C5:3
1761-Micro Preset 0< DN
Accum 0<
PUMP
DOWN Roughing Valve
CYCLE Manual On
COUNTER From PB Flip Flop
C5:0.ACC B3:0
0002
0 8
VACUUM PUMP
MOTOR STARTER
1MR_VERIFY
I:0 C5:3
0003 RES
4
1761-Micro
CHAMBER FILL
GAS VALVE
2SOL
O:0
3
1761-Micro
0004 END