Strength Calculation Report-3X49
Strength Calculation Report-3X49
1.Design Condition
1.1Design Application
Length 2279 2.279 m
Solar Panel Dimension
Width 1134 mm= 1.134 m
2
Area 2.58 m
Weight 28.5 Kg= 279.3 N
Panels Layout: 3 Lines 49 Rows
Installation Tilt Angle: 5 deg
2.Strength Calculation
2. 2 Wind load
Wind load W=Cw x qx Aw
=Cw x [0.6x V0^2 xE x I] x Aw
=Cw x [0.6x V0^2 x(Er^2 x Gf) x I] x Aw
=Cw x [0.6x V0^2 x(1.7x [H/Zg]^a x Gf) x I] x Aw
Formula:
When H <Zb Er=1.7x [Zb/Zg]^a Er= 0.691
When H >Zb Er=1.7x [H/Zg]^a Er= 0.501
Ground Type [positive pressure]
Cw[positive pressure]= 0.35+0.055θ-0.0005θ^2
= 0.613 (5~60deg)
Portrait Beam
positive pressure L2wz= G2+Wz= 264702.392 N
negative pressure L2wf= G2+Wf= -336696.368 N
The absolute value of positive pressure is less than the negative pressure.
630 3700
5.Buckling of Supporting
Basci Info
Material:Al6005-T5
Yield strength:[σ]= 215 Mpa
Elastic coefficient: E= 6.90E+10 N/㎡ 6.90E+06 N/cm²
Section factor Wx= 14439 mm^3 1.44E-05 m^3
Secondary Torque Ix 613644 mm^4 6.14E+01 cm^4
The Rear leg is longer,and just allows less pressure on the system;Here we calculted based on the longer Rear leg.
n= 1
L 6= 323 cm
The Max pressure allowed for Rear Leg as: P k=n*∏^2*E*I M/L6^2= 40015 N= 40.01 KN
1.This 3*49 array is with 32 leg in total(Front Leg 16Pcs、Rear Leg 16Pcs)
W4=G2+Wz/32= 8271.949751 N= 8.27 KN
8.27KN<40.01KN OK