Hilti PROFIS Engineering 3.0.

87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 1
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

Specifier's comments:

1 Input data
Anchor type and size: HIT-HY 200-R V3 + HAS-U 8.8 HDG M10
Return period (service life in years): 50
Item number: 2223948 HAS-U 8.8 HDG M10x190 (insert) / 2262131
HIT-HY 200-R V3 (mortar)
Effective embedment depth: hef,act = 80.0 mm (hef,limit = - mm)
Material: 8.8
Approval No.: ETA 19/0601
Issued I Valid: 2‫‏‏‬/6‫‏‏‬/2023 | -
Proof: SOFA based on EN 1992-4, Chemical
Stand-off installation: without clamping (anchor); restraint level (baseplate): 2.00; eb = 20.0 mm; t = 5.0 mm
2
Hilti Grout: , multipurpose, fc,Grout = 30.00 N/mm
Baseplate :
R lx x ly x t = 110.0 mm x 400.0 mm x 5.0 mm; (Recommended plate thickness: not calculated)

Profile: no profile
Base material: 2
cracked concrete, Custom, fc,cyl = 25.00 N/mm ; h = 200.0 mm, Temp. short/long: 30/40 °C, User-defined
partial material safety factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid baseplate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 2
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 ULS N = 0.000; Vx = 1.100; Vy = 0.000; no no 34
Mx = 0.000; My = 0.110; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

2 Load case/Resulting anchor forces y

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 1.446 1.100 1.100 0.000 Compression
1 x
max. concrete compressive strain: 0.02 [‰]
Tension
max. concrete compressive stress: 0.61 [N/mm ]
2

resulting tension force in (x/y)=(-25.0/0.0): 1.446 [kN]


resulting compression force in (x/y)=(51.1/0.0): 1.446 [kN]

Anchor forces are calculated based on the assumption of a rigid baseplate.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 3
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

3 Tension load EN 1992-4, Section 7.2.1


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel failure* 1.446 30.933 5 OK
Combined pullout-concrete cone failure** 1.446 10.280 15 OK
Concrete Breakout failure** 1.446 13.774 11 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

3.1 Steel failure

NRk,s [kN] gM,s NRd,s [kN] NEd [kN]


46.400 1.500 30.933 1.446

3.2 Combined pullout-concrete cone failure


2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ]
48,000 57,600 15.00 240.0 120.0 80.0 25.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
y g,Np y g,Np
1.023 8.18 7.700 10.96 1.000 1.000

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


0.0 1.000 0.0 1.000 0.900 1.000
0
y sus asus y sus
0.890 0.000 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NEd [kN]
20.560 15.420 1.500 10.280 1.446

Group anchor ID
1

3.3 Concrete Breakout failure


2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
48,000 57,600 120.0 240.0 25.00

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 0.900 1.000
0
z [mm] y M,N k1 NRk,c [kN] gM,c NRd,c [kN] NEd [kN]
76.1 1.000 7.700 27.548 1.500 13.774 1.446

Group anchor ID
1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 4
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

4 Shear load EN 1992-4, Section 7.2.2


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel failure (without lever arm)* 1.100 18.560 6 OK
Steel failure (with lever arm)* 1.100 3.317 34 OK
Pryout failure** 1.100 20.560 6 OK
Concrete edge failure in direction x+** 1.100 5.912 19 OK

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel failure (without lever arm)


0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
23.200 1.000 23.200 1.250 18.560 1.100

4.2 Steel failure (with lever arm)

l [mm] aM
27.5 2.00
0 0
NEd / NRd,s 1 - NEd / NRd,s MRk,s [kNm] MRk,s = MRk,s (1 - NEd/ NRd,s) [kNm]
0.047 0.953 0.060 0.057
M M
VRk,s = aM * MRk,s / l [kN] gMs VRd,s [kN] VEd [kN]
4.146 1.250 3.317 1.100

4.3 Pryout failure (bond relevant)


2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] ccr,Np [mm] scr,Np [mm] cmin [mm] fc,cyl [N/mm ]
48,000 57,600 15.00 120.0 240.0 80.0 25.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
k8 y g,Np

1.023 8.18 7.700 10.96 2.000 1.000

y g,Np ec1,V [mm] y ec1,Np ec2,V [mm] y ec2,Np y s,Np


1.000 0.0 1.000 0.0 1.000 0.900
0
y re,Np y sus asus y sus
1.000 0.890 0.000 1.000
0
NRk,p [kN] NRk,p [kN] gM,c,p VRd,cp [kN] VEd [kN]
20.560 15.420 1.500 20.560 1.100

Group anchor ID
1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 5
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

4.4 Concrete edge failure in direction x+

lf [mm] dnom [mm] k9 a b 2


fc,cyl [N/mm ]
80.0 10.00 1.700 0.100 0.066 25.00
1
C[ ]
y b,g mm
4
d [mm] tg [mm]
0.867 0.043 10.0 20.0
2 0 2
c1 [mm] Ac,V [mm ] Ac,V [mm ]
80.0 28,800 28,800

y s,V y h,V aV [°] y a,V ec,V [mm] y ec,V y re,V


1.000 1.000 0.00 1.000 0.0 1.000 1.000
0
VRk,c [kN] kT gM,c VRd,c [kN] VEd [kN]
10.224 1.0 1.500 5.912 1.100

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 6
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

5 Combined tension and shear loads (EN 1992-4, Section 7.2.3)


Steel failure

bN bV a Utilization bN,V [%] Status


0.047 0.059 2.000 1 OK

a a
bN + bV £ 1.0

Concrete failure

bN bV a Utilization bN,V [%] Status


0.141 0.186 1.500 14 OK

a a
bN + bV £ 1.0

6 Displacements (highest loaded anchor)


Short term loading:

NSk = 1.071 [kN] dN = 0.0426 [mm]


VSk = 0.815 [kN] dV = 0.0489 [mm]
dNV = 0.0649 [mm]
Long term loading:

NSk = 1.071 [kN] dN = 0.0938 [mm]


VSk = 0.815 [kN] dV = 0.0652 [mm]
dNV = 0.1142 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are
valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not included in this
calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 7
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

7 Warnings
• The anchor design methods in PROFIS Engineering require rigid baseplates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA
TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the baseplate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum
required baseplate thickness with CBFEM to limit the stress of the baseplate based on the assumptions explained above. The proof if the rigid
baseplate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing
conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters of the
clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Drilled hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice, blow
twice with oil-free compressed air (min. 6 bar)).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 8
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

8 Installation data
2
Baseplate, steel: S 275; E = 210,000.00 N/mm ; fyk = 275.00 N/mm
2 Anchor type and size: HIT-HY 200-R V3 + HAS-U 8.8 HDG
M10
Profile: no profile Item number: 2223948 HAS-U 8.8 HDG M10x190 (insert) /
2262131 HIT-HY 200-R V3 (mortar)
Hole diameter in the fixture: df = 12.0 mm Maximum installation torque: 20 Nm
Plate thickness (input): 5.0 mm Hole diameter in the base material: 12.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 80.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 110.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Hilti HAS-U threaded rod with HIT-HY 200-R V3 injection mortar with 80 mm embedment h_ef, M10, Hot dip galvanized, Hammer drilling
installation per ETA 19/0601

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required accessories • Dispenser including cassette and mixer
• Properly sized drill bit to blow from the bottom of the hole • For deep installations, a piston plug is
• Proper diameter wire brush necessary
• Torque wrench

y
55.0 55.0
200.0

200.0

1
x
200.0

200.0

30.0 80.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -25.0 0.0 - 80.0 250.0 250.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.87

www.hilti.com.qa
Company: QATAR TECHNICAL ALUMINIUM Page: 9
Address: New Industrial Area P. O. Box 24442, Doha, Qatar Specifier:
Phone I Fax: 44580499 | E-Mail: alum@qta.info
Design: Anchor Date: 16‫‏‏‬/8‫‏‏‬/2023
Fastening Point:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each
case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data
or programs, arising from a culpable breach of duty by you.