Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

8 7 6 5 4

110 PACK KEOFITT SPIKE SAMPLING BAG 1L F


ART. NO. 171000

GENERAL 8 7
The KEOFITT Spike Sampling Bag is a cost-effective single-use sampling bag to be used where sterile
sampling is not required. Samples are to be analyzed within hours orA days
( 1:4 )after sampling.
E
It features a unique septum allowing 3,5 mm needles for fast and convenient sampling of most liquids

69,2 mm

51,2 mm
Primary Port
Secondary Port

including viscous products. Septum area protected by a polypropylene cap to be removed before use.
O. D. n8,0 mm

F
I. D. n6,1 mm

398,2 mm
Auto-sealing septum to prevent contamination of the sample. KEOFITT SPIKE SAMPLING BAGTM

328 mm
800 ml

B ( 1:4 )
The KEOFITT Spike Sampling Bag is a multi-layer sampling bag Dmade from polypropylene and manufac- Remove Protective Cover
600 ml

tured under clean room conditions Class C (equivalent to ISO class 8). 400 ml

130 mm Art. No. 171000

Secondary port equipped with septum allowing partly or fully exstraction of the sample by using a
Size 1000 ml
Lot Id. xxxxxxx
M-Date xxxxxx 200 ml

needle. Alternatively the hose on the secondary port can be cut open.
C

FEATURES
Secondary port: suitable for needles alternative-
Primary port: to be used with spike (800017).
A ( 1:4 ) ly the hoze can be cut open.
B

CERTIFICATION* E

69,2 mm
Declaration of Conformity

51,2 mm
Primary Port
Secondary Port
TECHNICAL DATA A
O. D. n8,0 mm 8 7
Material I. D. n6,1 mm
Bag: PP 8 7 6 5 4

Septum primary port: Chlorobutyl rubber


Membrane housing: Polycarbonat
Septum secondary port: Synthetic polyisoprene

398,2 mm
F KEOFITT SPIKE SAMPLING BAGTM

STERILITY
800 ml

328 mm
Manufacturing: Clean room conditions Class C (equivalent to ISO class 8)
Packaging: Under usual clean conditions 600 ml

Sterilizing: None

D
B ( 1:4 ) 400 ml

Temperature Art. No.


Size
Lot Id.
M-Date
171000
1000 ml
xxxxxxx
xxxxxx 200 ml

Up to 121°C / 249° F. Remove Protective Cover

Permeability
The permeability of gasses is given by the approximate values below:
Water Vapour: 0,7 g/m2/day
Carbon Dioxide:
Oxygen:
3900 cm3/m2/day
860 cm3/m2/day
A ( 1:4 ) 130 mm

Spare parts E
69,2 mm

Shelf life: 2 years Primary Port


Storage temparature: 0-40° C (32-104° F), protected from direct sunlight (UV) Secondary Port
Storage humidity: Less than 80%
O. D. n8,0 mm
Packaging: Keep stored in original closed containers.
I. D. n6,1 mm
C

*For further information and downloads please visit www.keofitt.dk


B ( 1:4 )
KEOFITT A/S reserves the right to change technical data without notice! Valid version of the data sheet is available on www.keofitt.dk

D
Updated 23-08-2022