INTERNAL

1. Barrier Gate
2. Vehicle Loop detector - Power 220 V, 80 W
- Power 220 V, - Length arm 3 m, speed open/close 3s
- Adjustable sensitivity - Controll by loop detector (in) and
- Reaction time 10 ms communication module via RS485 (out)
in out interface
- With LED sop and go sign

Tare

Operator 3. CCTV
4. Scoreboard display
- IP 65, Outdoor type
Room - Outdoor type
- IP communication
- RS232 interface
interface
- 6 digit number
out in

Front
Gross

Rear

INTERNAL Do Not Distribute


INTERNAL

* Supplier scope

interlocking Flow Process Barrier gate in truck scale,


Barrier gate-in Barrier gate-out
1. Barrier Gate-in and -out normaly in
close postion (if no activity weighing).
2. Vehicle Loop Detector detected truck
RS485
VLD and Barrier gate-in open while truck
come to truck scale for tare/gross
weighing.
Barcode PC 3. Truck has in ready to tare/gross
Printer
scanner (CDAS system)
weighing position, Barrier Gate-in close
* Supplier scope
interlocking.
RJ45 4. Truck has finished for weighging
CCTV
tare/gross, then send signal to Barrier
Gate-out to open. Then back to normal
Mettler Toledo
Loadcell position (close).
IND246
* Supplier scope
RS232

Score Board

INTERNAL Do Not Distribute